ETC 6P27C

Product Data Sheet
5V TO 3.3V,
AND PROGRAMMABLE DC/DC CONVERTER
WITH PARALLELABLE BOOST MODULES
6-PAK
DESCRIPTION
The 6-PAK™ is a modular system of control and boost
SIPs. Each 6A control SIP can also drive up to 8 additional
6A boost SIPs in parallel, for a total of 54A. Each SIP
accepts a regulated 5V input (+10%) and provides 1.8V to
3.6Vdc output. The circuit is optimized for high efficiency
and fast load transient response needed by telecom, DSP
and microprocessor applications.
FEATURES
!
!
!
!
!
!
!
Small SIP Design
Parallelable Boost SIP
One stocking part meets a variety of loads
Programmable Control SIP
Control/Boost Pair extremely configurable
Fast Transient Response
No need for large external capacitors
Extremely small footprint
Low Component Count
Low cost, high reliability
Staked Pins
Wave solderable
Integrated Input Filter
Low input ripple
Advanced thermal design, monolithic power circuitry and
synchronous rectification result in outstanding performance
and value. With integrated input filter and output capacitors,
the 6-PAK system makes a complete power supply which
requires no external components over the specified
operating range. Pins are staked for wave solderability.
APPLICATION NOTE
!
DCAN-34 - 6-PAK Demo Board
Downloadable from our website cdpowerelectronics.com
More product information and application notes are available
on our website at www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 520.295.4100
Fax: 520.770.9369
6-PAK 11/99 REV D
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133
Fax:+353.61.474.141
Page 1
Electrical Specifications
Unless otherwise specified, operating conditions are as follows: Vin=5V, Vo=3.3V, Io=6A, TA=25°C, Cin=100µF, Co=µF.
Parameter
Input
Input Voltage
Conditions
Vin
Min
Typ
Max
4.5
5.0
5.5
Input Current Ripple
Required Capacitance
Units
VDC
200
mARMS
0
100
µF
3.3
C in
Note 1
Vo
Nominal
3.25
Note 2
Output
Output Voltage
Output Program Range
Output Current
Io
Output Ripple
Output Rise Time
TA=25°C
3.35
VDC
1.8
3.6
VDC
0
6
Amps
50
mVp-p
20Mhz BW
Tr
Output Capacitance Range Co
0
Line Regulation
Io min - Io max
Load Regulation
Temperature Coefficient
Tc
Combined Variation
5000
µF
+0.5
%
+0.5
%
0.01
%/°C
Vin min-max &/or Io min-max
TA=25°C- 85°C
Protection
µS
12
-2
+2
%
Note 3
General
Switching Frequency
Dynamic Response
∆I O / ∆ t = 1A/1 0! sec, Vi = 5.0V, TA = 25°C
Load Change from I O = 0% to IO = 100%
Peak Deviation
Settling time (VO<10% Peak Deviation)
Load change from I O = 100% to I O = 0%
Peak Deviation
Settling time (VO<10% Peak Deviation)
800
kHz
60
150
mV
µsec
90
100
mV
µsec
Temperature
Operating Temperature
Storage Temperature
Note 4
+60
°C
-40
+125
°C
Notes
1. Input source<3” from 6-PAK™, load transient <3A per SIP. 100µF low ESR capacitor for load transients >3A per
SIP.
2. Optional programming 1.8 - 3.6 or +10% available. See Table.
3. Short circuit and thermal protection.
4. 100 lfm air, Vo=3.3V, Io=6A. See Thermal Design Guide for other conditions.
Page 2
6-PAK 11/99 REV D
Programming
Thermal Design Guide
The 6-PAK™ is programmed through the Control SIP. All
connected Power Boosters follow the Control SIP
programming. To program the 6-PAK™ for Vout<3.3,
connect a resistor across the TRIM and Vo pins. For
Vout>3.3, resistor is connected across TRIM and GND.
Table 2
Locate your operating current, read the junction temp rise
from the graph and add to your maximum ambient. 135°C
is the maximum allowable operating junction temperature.
Test conditions: Device soldered into 4” X 4: PCB, 2-sided
with power and ground planes for heat conduction. Due to
the difficulty in predicting the thermal effects of airflow
velocity and direction, and thermal conduction through
ground planes, it is important that the 6-PAK™ be evaluated
thermally in each application. For high ambient temperature/
high current application, please request our Application
Note, “Accurate Measurements of 6-PAK™ Junction
Temperature.”
Vout
Resistor Value
Vout
Resistor Value
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.7
0Ω
15.6Ω
34Ω
55.6Ω
80.6Ω
110Ω
147Ω
196Ω
255Ω
332Ω
2.8
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.6
442Ω
604Ω
866Ω
1.37k
2.80k
Open
2.32k
1.00k
649Ω
Tj Rise vs. Io
(Junction Temp Rise vs. Output Current)
Operating conditions are as follows: Vin=5V, Vo=3.3V, Load
change from Io=0% to Io=100%, TA=25°C, Cin=0F, Co=µF.
Temp Rise C°
Transient Response
Output Current - Amps
Efficiency %
Efficiency
Operating conditions are as follows: Vin=5V, Vo=3.3V, Load
change from Io=100% to Io=0%, TA=25°C, Cin=0F, Co=µF.
Output Current - Amps
Ordering Information
Typical examples:
6-PAK 11/99 REV D
6P
25 -
C
6A Control SIP
6P
25 -
P
6A Power Booster SIP
Page 3
Mechanical Outline
TOLERANCES
+.008” for 3 place decimals
+ .02” for 2 place decimals
+ .002” for pin diameter
Pin Out
Pin
1
2
3
4
5
6
7
8
9
System Interconnection Guidelines
Function
Vo
Vo
TRIM
GND
INTI
Gnd
INT2
Vi
Vi
Description
Output Voltage
Output Voltage
Output Adjust*
Ground
InterModule 1
Ground
InterModule 2
5V Input Voltage
5V Input Voltage
1. Each SIP must have input, ground and output pins
sunk into common input ground and output planes in
the host PC board.
2. Two additional common signal traces are required to
interconnect INT1 and INT2 pins. These traces must
be a least 0.06” wide and make a straight connection
among the modules.
3. Power Booster SIP must be adjacent to the Control
SIP located in the center of the layout, as shown in
the Typical Example figure. Recommended distance
between SIP pin centers is 0.5”.
* not connected on Boosters
Standard Options are shown, consult factory for other available options.
The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No
patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES
product for use in life support devices/systems or in aircraft control applications.
Page 4
6-PAK 11/99 REV D