TI 74AC11034

54AC11034, 74AC11034
HEX NONINVERTERS
SCAS034A – FEBRUARY 1988 – REVISED APRIL 1993
•
•
•
•
•
54AC11034 . . . J PACKAGE
74AC11034 . . . DW OR N PACKAGE
(TOP VIEW)
Flow-Through Architecture Optimizes
PCB Layout
Center-Pin VCC and GND Configurations
Minimize High-Speed Switching Noise
EPIC  (Enhanced-Performance Implanted
CMOS) 1-µm Process
500-mA Typical Latch-Up Immunity
at 125°C
Package Options Include Plastic
Small-Outline Packages, Ceramic Chip
Carriers, and Standard Plastic and Ceramic
300-mil DIPs
1Y
2Y
3Y
GND
GND
GND
GND
4Y
5Y
6Y
1
20
2
19
3
18
4
17
5
16
6
15
7
14
8
13
9
12
10
11
1A
2A
3A
NC
VCC
VCC
NC
4A
5A
6A
description
These devices contain six independent
noninverters. They perform the Boolean function
Y = A.
3A
NC
VCC
VCC
NC
54AC11034 . . . FK PACKAGE
(TOP VIEW)
The 54AC11034 is characterized for operation
over the full military temperature range of – 55°C
to 125°C. The 74AC11034 is characterized for
operation from – 40°C to 85°C.
2A
1A
1Y
2Y
3Y
INPUT
A
OUTPUT
Y
H
H
L
L
2A
20
19
17
6
16
7
15
8
14
9 10 11 12 13
4A
5A
6A
6Y
5Y
logic diagram (positive logic)
1
1
2
1Y
1A
20
1
19
2
18
3
13
8
12
9
11
10
2Y
18
3
4A
13
8
4Y
5A
12
9
5Y
6A
11
10
6Y
3A
5
NC – No internal connection
logic symbol†
1A
3 2 1 20 19
18
GND
GND
GND
GND
4Y
FUNCTION TABLE
(each inverter)
4
3Y
† This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
Pin numbers shown are for the DW, J, and N packages.
2A
3A
4A
5A
6A
1Y
2Y
3Y
4Y
5Y
6Y
EPIC is a trademark of Texas Instruments Incorporated.
Copyright  1993, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2–1
54AC11034, 74AC11034
HEX NONINVERTERS
SCAS034A – FEBRUARY 1988 – REVISED APRIL 1993
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 100 mA
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
recommended operating conditions
54AC11034
VCC
Supply voltage
VIH
High-level input voltage
VCC = 3 V
VCC = 4.5 V
VCC = 5.5 V
VCC = 3 V
NOM
MAX
MIN
NOM
MAX
3
5
5.5
3
5
5.5
2.1
2.1
3.15
3.15
3.85
3.85
VIL
Low-level input voltage
VI
VO
Input voltage
0
Output voltage
0
IOH
High-level output current
IOL
Low-level output current
∆t /∆v
Input transition rise or fall rate
TA
Operating free-air temperature
2–2
74AC11034
MIN
VCC = 4.5 V
VCC = 5.5 V
0.9
0.9
1.35
1.65
VCC = 3 V
VCC = 4.5 V
V
1.65
0
0
VCC
VCC
–4
–4
– 24
– 24
VCC = 5.5 V
VCC = 3 V
– 24
– 24
12
12
VCC = 4.5 V
VCC = 5.5 V
24
24
POST OFFICE BOX 655303
V
V
1.35
VCC
VCC
UNIT
24
V
V
mA
mA
24
0
10
0
10
ns/ V
– 55
125
– 40
85
°C
• DALLAS, TEXAS 75265
54AC11034, 74AC11034
HEX NONINVERTERS
SCAS034A – FEBRUARY 1988 – REVISED APRIL 1993
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
IOH = – 50 µA
IOH = – 24 mA
A
IOH = – 50 mA†
IOH = – 75 mA†
MIN
MAX
MIN
2.9
4.5 V
4.4
4.4
4.4
5.5 V
5.4
5.4
5.4
3V
2.58
2.4
2.48
4.5 V
3.94
3.7
3.8
5.5 V
4.94
4.7
4.8
MAX
V
3.85
3V
0.1
0.1
0.1
4.5 V
0.1
0.1
0.1
5.5 V
0.1
0.1
0.1
3V
0.36
0.5
0.44
4.5 V
0.36
0.5
0.44
5.5 V
0.36
0.5
0.44
IOL = 50 mA†
IOL = 75 mA†
5.5 V
VI = VCC or GND
VI = VCC or GND,
5.5 V
UNIT
3.85
5.5 V
IOL = 24 mA
74AC11034
2.9
IOL = 12 mA
II
ICC
54AC11034
2.9
5.5 V
IOL = 50 µA
VOL
TA = 25°C
TYP
MAX
3V
IOH = – 4 mA
VOH
MIN
V
1.65
5.5 V
1.65
± 0.1
IO = 0
5.5 V
4
VI = VCC or GND
5V
3.5
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
±1
±1
µA
80
40
µA
Ci
pF
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A
Y
TA = 25°C
MIN
TYP
MAX
54AC11034
74AC11034
MIN
MAX
MIN
MAX
1.5
5.7
9.1
1.5
10.7
1.5
10.1
1.5
5.5
8.3
1.5
9.9
1.5
9.2
UNIT
ns
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A
Y
TA = 25°C
MIN
TYP
MAX
54AC11034
74AC11034
MIN
MAX
MIN
MAX
1.5
4
6.3
1.5
7.4
1.5
6.9
1.5
4
6.2
1.5
7.3
1.5
6.8
UNIT
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
TEST CONDITIONS
Power dissipation capacitance per gate
POST OFFICE BOX 655303
CL = 50 pF,
• DALLAS, TEXAS 75265
f = 1 MHz
TYP
UNIT
27
pF
2–3
54AC11034, 74AC11034
HEX NONINVERTERS
SCAS034A – FEBRUARY 1988 – REVISED APRIL 1993
PARAMETER MEASUREMENT INFORMATION
Input
(see Note B)
From Output
Under Test
CL = 50 pF
(see Note A)
VCC
50%
50%
0V
tPLH
tPHL
500 Ω
50% VCC
Output
VOH
50% VCC
VOL
VOLTAGE WAVEFORMS
LOAD CIRCUIT
NOTES: A. CL includes probe and jig capacitance.
B. Input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns.
C. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
2–4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated