Emergency Stop Devices Push Buttons 800 E-Stops ! Specifications—22.5mm Back of Panel Components Front of Panel (Operators) Electrical Ratings Mechanical Ratings Description Vibration (assembled to panel) Shock Degree of protection Mechanical design life (typical) Environmental Temperature range (operating): per IEC 947-1 Temperature range (short term storage): per IEC 947-1 Materials Bushings, mounting rings Bezels Seals: diaphragm style Seals: lip and flat gasket styles Illuminated lenses Plastic (800EP/ES) Metal (800EM/EB) 10 to 2000Hz, 1.52mm displacement (peak-to-peak) max./10g max. 1/2 cycle sine wave for 11ms and no damage at 100g IP66 (NEMA Type 3, IP66 (NEMA Type 3, 3R, 4, 4X, 12, 13) 3R, 4, 12, 13) 500,000 cycles: mushroom 100,000 cycles: operators mushroom key operators (plastic), push-pull/twist 50,000 cycles: operators mushroom key operators (metal) -25°C to +55°C (-13°F to +131°F) ➋ Description Standard contact block ratings➋ Thermal current Terminal marking Wire capacity (screw terminal) Dielectric strength (min) Electrical design life cycles Electrical shock protection: Per IEC 529 Mechanical Ratings Vibration -40°C to +70°C (85°C max. for 24 hours) -40°F to +158°F (185°F max. for 24 hours) Shock Glass-filled thermoplastic polyester, rated UL94 V-O Glass-filled thermoplastic polyester, rated UL94 V-O Silicone rubber Nitrile rubber Die-cast zinc; dark olive chromate finish Anodized aluminum (EB, EM, ES line) Transparent nylon Type 12 Contact block mechanical design Contact operation Operating forces (typical) Environmental Temperature range Operating ➋➌ Short term storage ➌ Materials Springs Electrical contacts: Standard Low voltage ! See Performance Data: refer to page Important-2 of the A113 Industrial Controls catalogue. ➋ Operating temperature below 0°C (32°F) are based on the absence of freezing moisture and liquids. ➌ Per IEC 947-1. ➍ UL File & Guide Number E14840. 6-14 2-Across Style 3-Across Style NEMA, EEMAC NEMA, A600, A600, Q600, VDE Q600, 600V AC; 0660; AC15, DC 13 AC15, DC 13 to to IEC 947 IEC 947 10A max. 10A max. without continuous current enclosure (40°C to UL508, CSA22.2 (104°F) ambient) 6A #14, IEC 947, VDE with enclosure 0660, part 200 (60°C (140°F)) Conforming to CENELEC EN50013 Min of (1) #20AWG #18 to #12AWG Max of (2) (0.75 to 2.5mm 2) #14AWG or (1) Max (2) #14AWG #12AWG or (1) #12 AWG 2,200V for one minute 1,000,000 at 2A Finger-safe conforming to IP2X 10 to 2000Hz 1.52mm displacement (peakto-peak) max./10g max. 6hr 1/2 cycle sine wave for 11ms and no damage at 100g min 5,000,000 cycles 10 to 150Hz 0.15mm displacement (peakto-peak) max./2g max. 6hr 1/2 cycle sine wave for 11ms and no damage at 50g max N.C. slow make, double break (positive opening); N.C.L.B. late break, double break (positive opening) 2.78N: all contact 2.6N: each N.C. blocks contact block -25°C to +55°C (-13°F to +131°F) -25°C to +55°C (70°C max for 24 hrs) (-13°F to +131°F (158°F max for 24 hrs)) Stainless steel and zinc coated music wire Silver nickel alloy Fine silver Palladium silver Gold-plated over alloy: spanner; gold- silver plated silver nickel: stationary contacts Terminals: Screw type Plated steel Push-on type Agency approvals Approvals UL listed ➍/CSA certified Standard conformity UL508, UL486E NEMA ICS-1 and CSA22.2 #14, ICS-2 IEC 204-1, NEMA ICS-1 and 947; SEV 1005, ICS-2 (1983), IEC 1093; VDE 0113, 144, IEC 947-1, IEC 0660 Part 201; BS 947-5, VDE 0550, 4794; CEE 24; UL VDE 0660, Part 200 486E, UL 508, CSA22.2 #14 Emergency Stop Devices Push Buttons 800 E-Stops Product Selection—22.5mm 2-Position Push-Pull Operators, Non Illuminated—Twist-to-Release, Push-Pull 40mm Trigger Action Twist-to-Release Mushroom Colour 40mm Twist-to-Release Mushroom Operator Material Plastic Metal 40mm Mushroom Operator Twist-to-Release — Round (Trigger Action) ! Plastic Red 40mm Push-Pull Mushroom Push-Pull Twist-to-Release — Round ➋ Metal Plastic Push-Pull — Round ➋ Metal 800E-15YE112 Legend Plate for 40mm Ca Catalogue Number 800EP-MTS44 800EM-MTS44 800EP-MT4 800EM-MT4 800ES-MP24 800EM-MP24 2-Position Trigger Action Operators, Non Illuminated—Key Release ➌ 40mm Key Release Mushroom 60mm Key Release Mushroom 2 Position Trigger Action ! Mushroom Operator Colour Ronis Key Lock Red Zadi Key Lock 800E-16YE112 Legend Plate for 60mm Cap Size Catalogue Number 40mm—Round 800EP-MKR44 60mm—Round 800EP-MKR64 40mm—Round 800EP-MKZ44 60mm—Round 800EP-MKZ64 Back-of-Panel Components, Non Illuminated Operators Mounting Latch and Contact Block Combination 2-Across 3-Across Mounting 2-Across 3-Across Contact ➊➋ 1 N.C. Late break Catalogue Number 800E-2LX01L 1 N.O. - 1 N.C. Late break 800E-2LX11L 1 N.C. Late break 800E-3LX01L 1 N.O. - 1 N.C. Late break 800E-3LX11L 800E-2LX01LS 2-Across 1 N.C. Self-monitoring 3-Across 800E-3LX01S ! Trigger action operators are compliant with EN418 standards using standard N.C., N.C. Late Break, or N.C. Self-Monitoring contact blocks. Key Release operators are IP66, Type 4/13. ➋ Emergency stop push buttons are compliant with EN 418 standard when using N.C. Late break (N.C.L.B.) contact blocks. ➌ Key release operators are IP66, Type 4 and 13. 6-15 Emergency Stop Devices Push Buttons 800 E-Stops Product Selection—22.5mm 2-Position Red Push-Pull Operators, Illuminated —Mushroom ➊ 40mm Mushroom Push-Pull 800E-15YE112 Legend Plate for 40mm Cap 60mm Jumbo Mushroom Push-Pull Operator Material Size Catalogue Number 40mm 800ES-LMP24 60mm 800ES-LMJP24 40mm 800EM-LMP24 60mm 800EM-LMJP24 Plastic Metal Back-of-Panel Components, Illuminated Operators 2-Across (5 ckts. max.) Mounting 3-Across (4 ckts. max.) Type Volts Catalogue Number 24 AC/DC 800E-2DL3 120 AC/DC 800E-2DL5 24 AC/DC 800E-2DL3R 120 AC 800E-2DL5R 24 AC/DC 800E-3DL3 120 AC/DC 800E-3DL5 24 AC/DC 800E-3DL3R 120 AC 800E-3DL5R 800E-2TL5 Incandescent 2-Across LED (red) Incandescent Full Voltage Power Module with Latch 3-Across LED (red) 2-Across (3 ckts. max.) 3-Across (2 ckts. max.) Incandescent 2-Across LED (red) Incandescent 3-Across LED (red) Transformer Power Module with Latch 2-Across 24 AC/DC 120 AC/DC 800E-2TL7 24 AC/DC 800E-2TL5R 120 AC 800E-2TL7R 24 AC/DC 800E-3TL5 120 AC/DC 800E-3TL7 24 AC/DC 800E-3TL5R 120 AC 800E-3TL7R 3-Across 800E-2X01L 2-Across Late Break ! 3-Across Contact Blocks ! Emergency stop push buttons are compliant with EN 418 standard when using N.C.L.B. contact blocks. 6-16 1 N.C. Late break 800E-3X01L Emergency Stop Devices Push Buttons 800 E-Stops ! Specifications—30.5mm Electrical Ratings Dielectric strength Electrical design life cycles Mechanical Ratings Vibration Shock Degree of protection 2200V for one minute 1,000,000 at max. rated load 10 to 2000Hz 1.52mm displacement (peak-to-peak) max./10g max. (except Logic Reed) 1/2 cycle sine wave for 11ms ≥25g (contact fragility) and no damage at 100g Type 1, 4, 4X, 12, 13; watertight/oiltight IEC 529 IP66/65 Mechanical design life cycles 250,000 min. (Push-pull/twist-to-release) Contact operation Shallow, mini, and low voltage contact blocks: Slow, double make and break. Typical operating forces 7.5lbs max. push or pull 2-position push-pull Environment Temperature range Operating➋ -40°C to +55°C (-40°F to +131°F) Storage -40°C to +85°C (-40°F to +185°F) Standard Contact Ratings Maximum thermal continuous current Ith 10A AC/2.5A DC. Bulletin 800T units with 800T-XA contacts have ratings as follows: Max. Opertnl. Volts Ue Utilization Category IEC NEMA AC 600 AC-15 A600 DC 600 DC-13 Q600 Rated Operational Currents Volts Ue 120 to 600 72 to 120 24 to 72 28 to 600 24 to 28 ➌ Make Break 7200VA 720VA 60A 720VA 60A 10A 69VA 2.5A ! Performance Data: see publication A113, page Important-2. ➋ Operating temperatures below freezing are based on the absence of moisture and liquids. ➌ For applications below 24V/24mA, PenTUFF contacts are recommended. 6-17 Emergency Stop Devices Push Buttons 800 E-Stops Product Selection—30.5mm Emergency Stop Operators — 2-Position Red Non Illuminated 2-Position Push-Pull/Twist 2-Position Push-Pull Operator Position Contacts Maintained Out Maintained In N.C.L.B. ! Closed Open Enclosure Protection Release Catalogue Number Push-Pull 800T-FX6D4 Type 4 & 13 800T-FXT6D4 Push-Pull/Twist 800H-FRXT6D4 Type 4, 4X & 13 Push-Pull N.O. Open Closed N.C.L.B. ! Closed Open 800T-FXT6A1 Push-Pull/Twist 800H-FRXT6A1 Type 4, 4X & 13 N.C.L.B.! Closed Open N.C.L.B.! Closed Open Push-Pull 800T-FX6A5 Type 4 & 13 800T-FXT6A5 Push-Pull/Twist 800H-FRXT6A5 Type 4, 4X & 13 Push-Pull S.M.C.B. ➊➋ Closed Open 800T-FX6A1 Type 4 & 13 800TC-FX6D4S Type 4 & 13 800TC-FXT6D4S Push-Pull/Twist 800HC-FRXT6D4S Type 4, 4X & 13 Push-Pull N.O. Open Closed S.M.C.B. ➊➋ Closed Open 800TC-FXT6A1S Push-Pull/Twist 800HC-FRXT6A1S Type 4, 4X & 13 Push-Pull S.M.C.B. Closed Open S.M.C.B.➊➋ Closed Open 800TC-FX6A1S Type 4 & 13 800TC-FX6A5S Type 4 & 13 800TC-FXT6A5S Push-Pull/Twist Type 4, 4X & 13 800HC-FRXT6A5S Note: Emergency stop push buttons are compliant with EN-418 and IEC 60947-5-5 Standards when using N.C.L.B. contact blocks. ➊ Normally closed late break contact. When button is pushed from the OUT to IN position, the mechanical detent action of the operator occurs before electrical contacts change state. When the button is pulled from the IN to the OUT position, the electrical contacts change state before the mechanical detent occurs. ➋ The Self-Monitoring Contact Block (S.M.C.B.) is composed of a N.C.L.B. contact wired in series with a N.O. monitoring contact. The N.O. monitoring contact automatically closes when the S.M.C.B. is properly installed onto the E-Stop operator. If the S.M.C.B. is separated from the E-Stop operator, the N.O. monitoring contact will automatically open. 6-18 Emergency Stop Devices Push Buttons 800 E-Stops Product Selection—30.5mm 2-Position Red Illuminated, Push-Pull and Push-Pull/Twist Release Units Illuminated 2-Position Push-Pull/Twist Illuminated 2-Position Push-Pull Operator Position Contacts N.O. N.C.L.B.➊➋ Maintained Maintained Out In Type Lamp Volts Enclosure Protection Release Push-Pull 120 AC/DC Incan-descent 24 AC/DC Full Voltage Type 4 & 13 Type 4, 4X & 13 800H-FRXTQ10RA1 Push-Pull 800T-FXQ24RA1 Type 4, 4X & 13 LED 800H-FRXTQ24RA1 Push-Pull 800T-FXQH10RA1 Push-Pull/ Twist Push-Pull 24 AC/DC Open Closed Closed Open 120 AC Incan-descent Type 4 & 13 Type 4, 4X & 13 800T-FXTQH10RA1 800H-FRXTQH10RA1 800T-FXQH24RA1 800T-FXTQH24RA1 Push-Pull/ Twist 800H-FRXTQH24RA1 Push-Pull 800T-FXP16RA1 Type 4 & 13 Type 4, 4X & 13 800T-FXTQ24RA1 Push-Pull/ Twist Type 4 & 13 120 AC 800T-FXTQ10RA1 Push-Pull/ Twist Type 4 & 13 Type 4, 4X & 13 Catalogue Number 800T-FXQ10RA1 Push-Pull/ Twist 800T-FXTP16RA1 800H-FRXTP16RA1 800T-FXP26RA1 240 AC Transformer Type 4 & 13 Push-Pull Type 4, 4X & 13 Push-Pull/ Twist Type 4 & 13 Push-Pull Type 4, 4X & 13 Push-Pull/ Twist Type 4 & 13 Push-Pull Type 4, 4X & 13 Push-Pull/ Twist 800T-FXTP26RA1 800H-FRXTP26RA1 800T-FXPH16RA1 120 AC LED 800T-FXTPH16RA1 800H-FRXTPH16RA1 800T-FXPH26RA1 240 AC 800T-FXTPH26RA1 800H-FRXTPH26RA1 Note: A jumbo or large legend plate is recommended if space allows. Note: Emergency stop push buttons are compliant with EN-418 and IEC 60947-5-5 Standards when using N.C.L.B. contact blocks. ➊ Normally closed late break contact. When button is pushed from the OUT to IN position, the mechanical detent action of the operator occurs before electrical contacts change state. When the button is pulled from the IN to the OUT position, the electrical contacts change state before the mechanical detent occurs. ➋ Consult your local Allen-Bradley sales office for availability of illuminated E-Stops with Self Monitoring Contact Blocks (S.M.C.B.s). 6-19 Emergency Stop Devices Push Buttons 800 E-Stops Accessories Type Enclosure Plastic (IP66, NEMA 4/4X/13 Base Mount For use with 22.5mm Push Buttons Square Legend Plate Style Catalogue Number 800E-1PY 1 Hole 800E-2PY 2 Hole Yellow 3 Hole 800E-3PY 5 Hole 800E-5PY For 800E Buttons Aluminum Aluminum, Blank For 800 E Buttons Yellow, Emergency Stop 800E-19AE100 800E-15YE112 40mm Circular Legend Plate 60mm Circular Legend Plate For 800T Buttons Circular Legend Plate For 800H 6-20 Colour 800E-16YE112 Yellow, Blank 800T-X646 Yellow, Emergency Stop 800T-X646EM Yellow, Blank 800H-W690