Agilent 8560 EC Series Spectrum Analyzers Data Sheet Agilent 8560EC 30 Hz to 2.9 GHz Agilent 8561EC 30 Hz to 6.5 GHz 1 Agilent 8562EC 30 Hz to 13.2 GHz Agilent 8563EC 30 Hz to 26.5 GHz Agilent 8564EC 30 Hz to 40 GHz Agilent 8565EC 30 Hz to 50 GHz 1. The 8561EC has been discontinued and replaced with 8562EC. The Agilent 8560 EC Series spectrum analyzers have a color display, offer standard digitized fast time domain sweeps (Option 856xE-007 on the 8560 E Series), and are Class 3 MIL-rugged. The 8560 EC Series is identical to the 8560E Series in all other respects. Frequency Specifications, Agilent 8560 EC Series Unless noted, all specifications describe the instrument’s warranted performance under the following conditions: 5-minute warm-up from ambient conditions, autocoupled controls, digital display, IF ADJ ON, REF LVL CAL adjusted, SECOND IF OUTPUT and 1ST LO OUTPUT terminated in 50 Ω. After a 30-minute warm-up, and over a temperature range of 20 °C to 30 °C, the preselector does not have to be peaked at each signal of interest; under these conditions factory preselector peak values are sufficient to meet all specifications. Typical performance is non-warranted. Supplemental characteristics are denoted by “nominal” and “approximately”; these constitute non-warranted functional performance information derived during the design process and are not tested on a continuing basis. Frequency range Internal mixing External mixing 8560EC 30 Hz 2 to 2.9 GHz 18 GHz to 325 GHz 8561EC 30 Hz 2 to 6.5 GHz 18 GHz to 325 GHz Frequency band 30 Hz to 2.9 GHz 2.75 GHz to 6.46 GHz 5.86 GHz to 13.2 GHz 12.4 GHz to 26.8 GHz 26.4 GHz to 31.15 GHz 31.0 GHz to 50 GHz 8562EC 30 Hz 2 to 13.2 GHz 18 GHz to 325 GHz 8563EC 30 Hz 1 to 26.5 GHz 18 GHz to 325 GHz 8564EC 30 Hz 1 to 40 GHz 18 GHz to 325 GHz 8565EC 30 Hz 1 to 50 GHz 18 GHz to 325 GHz Harmonic mixing mode (N) 1 1 2 4 4 8 Frequency reference Temperature stability 3 Aging (per year) (per day nom.) Initial achievable accuracy Short-term warmup accuracy factors (nominal) 5 minute 15 minute ±1 x 10 –8 ±1 x 10 –7 ±5 x 10 –10 (4) ±2.2 x 10 –8 Option 856xEC-103 ±1x10 –6 ±2x10 –6 ±1 x 10 –6 ±1 x 10 –7 ±1 x 10 –8 Frequency readout accuracy (Start, stop, center and marker frequency functions) Span > 2 MHz x N 5 ±(freq readout x freq ref accuracy 6 +5% x span +15% x RBW +10 Hz) Span ≤ 2 MHz x N5 ±(freq readout x freq ref accuracy 6 +1% x span +15% x RBW +10 Hz) Frequency counter accuracy Marker count accuracy (S/N ≥ 25 dB) Accuracy at 1 GHz (25 °C, 1 yr aging, marker resolution = 1 Hz) Delta count accuracy (S/N ≥ 25 dB) Counter resolution ±(marker freq x freq ref accuracy 7 +2 Hz x N 5 +1 LSD of counter) ±225 Hz (5-minute warm-up) 7 ±135 Hz (15-minute warm-up) 7 ±3003 Hz (Option 856xEC-103) ±(delta freq x freq ref accuracy 6 + 4 Hz x N 5 +2 LSD) Selectable from 1 Hz to 1 MHz Frequency span Range Accuracy Span > 2 MHz x N 5 Span ≤ 2 MHz x N 5 1. 2. 3. 4. 5. 6. 7. 2 0, 100 Hz to full span (100 Hz x N 5 when using external mixers) ±5% ±1% Agilent 8563EC, 8564EC, 8565EC require Option 856xEC-006 for operation below 9 kHz. Agilent 8560EC, 8561EC, 8562EC minimum frequency in AC coupled mode is 100 kHz . In DC coupled mode minimum frequency is 30 Hz. –10 °C to +55 °C, referenced to 25 °C After 7 day warm-up N = harmonic mixing mode number Frequency reference accuracy = aging x time since last adjustment + initial achievable accuracy + temperature stability Short term warmup accuracy factors have been included in this calculation. Frequency Specifications, continued Sweep time Range Span = 0 Hz Span ±100 Hz RBW ≥ 300 Hz RBW ≤ 100 Hz Accuracy (Span = 0 Hz) Sweep time ≥ 30 ms Sweep time < 30 ms Sweep trigger 50 µs to 6000 s 50 ms to 2000 s 50 ms to 100 ks ±1% (digitized trace data) ±0.1% (digitized trace data) Delayed, free run, single, line, video, external Resolution bandwidth Range (–3 dB) Option 856xEC-1031 Accuracy 1 Hz to 1 MHz in a 1, 3, 10 sequence and 2 MHz (3 MHz at –6 dB) 10 Hz to 1 MHz in a 1, 3, 10 sequence and 2 MHz (3 MHz at –6 dB) 1 Hz to 300 kHz ±10% 1 MHz ±25% 2 MHz +50%, –25% Selectivity (–60 dB/–3 dB BW ratio) RBW ≥ 300 Hz RBW ≤ 100 Hz Video bandwidth range < 15:1 < 5:1 1 Hz to 3 MHz in a 1, 3, 10 sequence Noise sidebands (see Figure 1) Center frequency ≤ 1 GHz Offset 100 Hz 1 kHz 10 kHz 6 30 kHz 6, 8 100 kHz 7 ≤ –88 dBc/Hz 2 ≤ –97 dBc/Hz 2 ≤ –113 dBc/Hz 3 ≤ –113 dBc/Hz 4 ≤ –117 dBc/Hz 5 Option 856xEC-1031 ≤ –70 dBc/Hz 2 ≤ –90 dBc/Hz 2 ≤ –113 dBc/Hz 3 ≤ –113 dBc/Hz 4 ≤ –117 dBc/Hz 5 Residual FM (zero span, 10 Hz RBW) Option 856xEC-103 1. 2. 3. 4. 5. 6. 7. 8. 9. < 1 Hz pk-pk x N 9 in 20 ms < 0.25 Hz pk-pk x N 9 in 20 ms (typical) < 10 Hz pk-pk x N 9 in 20 ms Option 856xEC-103 is no longer offered. Add 5.2 x ((f/1 GHz)–1) for f > 1 GHz and f ≤ 2.9 GHz Add 2.5 x ((f/1 GHz)–1) for f > 1 GHz and f ≤ 2.9 GHz Add 3.0 dB x ((f/1 GHz)–1) for f > 1 GHz and f ≤ 2.9 GHz Add 2 dB for f > 1 GHz and f ≤ 2.9 GHz RBW ≤ 1 kHz or span ≤ 745 kHz RBW ≥ 3 kHz or span > 745 kHz Not specified at 30 kHz offset for Agilent 8564EC and Agilent 8565EC N = harmonic mixing mode number 3 Amplitude Specifications, Agilent 8560 EC Series Range Maximum safe input level Displayed average noise level (DANL) to +30 dBm Average continuous power +30 dBm (1 W, input attn ≥ 10 dB) Peak pulse power +50 dBm (100 W, input attn ≥ 30 dB) (≤ 10 ms pulse width, < 1% duty cycle) Maximum DC input voltage DC coupled ±0.2 Vdc AC coupled ±50 Vdc1 Displayed average noise level (DANL) (see Figure 2) (0 dB attenuation, 1 Hz resolution bandwidth2) 8560EC ≤ –90 dBm ≤ –105 dBm ≤ –120 dBm ≤ –120 dBm ≤ –140 dBm ≤ –151 dBm 30 Hz 3 1 kHz 3 10 kHz 100 kHz 1 MHz to 10 MHz 10 MHz to 2.9 GHz 2.9 GHz to 6.46 GHz 6.46 GHz to 13.2 GHz 13.2 GHz to 22.0 GHz 22.0 GHz to 26.8 4 GHz 26.8 GHz to 31.15 GHz 31.15 GHz to 40 GHz 40 GHz to 50 GHz 8561EC ≤ –90 dBm ≤ –105 dBm ≤ –120 dBm ≤ –120 dBm ≤ –140 dBm ≤ –145 dBm ≤ –145 dBm 8562EC ≤ –90 dBm ≤ –105 dBm ≤ –120 dBm ≤ –120 dBm ≤ –140 dBm ≤ –151 dBm ≤ –148 dBm ≤ –145 dBm 8563EC ≤ –90 dBm ≤ –105 dBm ≤ –120 dBm ≤ –120 dBm ≤ –140 dBm ≤ –149 dBm ≤ –148 dBm ≤ –145 dBm ≤ –140 dBm ≤ –139 dBm 8564EC, 8565EC ≤ –90 dBm ≤ –105 dBm ≤ –120 dBm ≤ –120 dBm ≤ –140 dBm ≤ –145 dBm ≤ –147dBm ≤ –143 dBm ≤ –140 dBm ≤ –136 dBm ≤ –139 dBm ≤ –130 dBm ≤ –127 dBm 1 dB gain compression Maximum power at mixer = input power (dBm) – input attenuation (dB) 10 MHz to 2.9 GHz –5 dBm 2.9 GHz to 6.46 GHz +0 dBm 5 6.46 GHz to 26.8 GHz –3 dBm 26.8 GHz to 50 GHz +0 dBm (nominal) CF=40 GHz –40 CF=25 GHz RBW = 100Hz –60 dBc/Hz CF=5 GHz –80 –100 Typical performance Spec @ CF = 1 GHz RBW selectivity RBW = 1 kHz RBW = 10 kHz CF=1 GHz RBW = 100 kHz CF=200 MHz 1k 10 k 100 k 1 MHz Offset Figure 1. Noise sidebands normalized to 1 Hz BW versus offset from carrier. 1. 2. 3. 4. 5. 4 1 Hz 10 10 Hz 2 MHz 100 Hz 1 MHz 100 kHz 10 kHz 1 kHz 1 Hz –120 1 Hz 0 –10 –20 –30 –40 –50 –60 –70 –80 –90 –100 10 Hz 100 1 kHz 10 k Offset 100 k 1M 10 MHz 100 Figure 2. Typical on-screen dynamic range versus offset from 1 GHz center frequency for all RBWs (mixer level = –10 dBm). Not applicable to 8564EC and 8565EC. For Option 856xEC-103, degrade DANL by 10 dB Agilent 8563EC, 8564EC, 8565EC require Option 856xEC-006 for operation below 9 kHz For Agilent 8563EC: 26.5 GHz Agilent 8561EC: –3 dBm Amplitude Specifications, continued Dynamic range (see Figure 3) Compression to noise 1 10 MHz to 2.9 GHz 2.9 GHz to 6.46 GHz 6.46 GHz to 13.2 GHz 13.2 GHz to 22.0 GHz 22.0 GHz to 26.8 GHz 26.8 GHz to 31.15 GHz 31.15 GHz to 40 GHz 40 GHz to 50 GHz 8560EC > 146 dB 8561EC > 140 dB > 142 dB 8562EC > 146 dB > 148 dB > 142 dB 8563EC > 144 dB > 148 dB > 142 dB > 137 dB > 136 dB 8564EC, 8565EC > 145 dB > 147 dB > 140 dB > 137 dB > 133 dB > 139 dB > 130 dB > 127 dB 8560EC > 95 dB 8561EC > 88.5 dB > 98.5 dB > 119 dB 8562EC > 95 dB > 111.5 dB > 119 dB > 117.5 dB 8563EC > 94dB > 111.5 dB > 119 dB > 117.5 dB > 115 dB > 114.5 dB 8564EC, 8565EC > 92 dB > 111 dB > 113.5 dB > 111.5 dB > 110 dB > 108 dB > 109.5 dB > 105 dB > 103.5 dB 8560EC > 108 dB 8561EC > 103 dB > 107 dB 8562EC > 108 dB > 108.5 dB > 101.5 dB 8563EC > 107 dB > 108.5 dB > 101.5 dB > 98 dB > 97.5 dB 8564E, 8565EC > 104 dB > 108 dB > 100 dB > 98 dB > 95.5 dB > 101 dB (nominal) > 95 dB (nominal) > 93 dB (nominal) Signal to distortion Harmonic 2 20 MHz to 1.45 GHz 1.45 GHz to 2 GHz 2 GHz to 3.25 GHz 3.25 GHz to 6.6 GHz 6.6 GHz to 11 GHz 11 GHz to 13.4 GHz 13.4 GHz to 15.6 GHz 15.6 GHz to 20 GHz 20 GHz to 25 GHz Intermodulation 3 –40 DANL (1 Hz BW) Third order distortion Second harmonic distortion –50 –60 –90 –100 –110 –70 –60 –50 45 . z-1 0H 3 GH z .8 31 .15 6.5 -50 -13 13.2 .2 -26 GHz GH .8 2.9 z, GH -6. 26. z 5 G 8-3 1M Hz 1.1 Hz 5G -2. Hz 9G Hz -26 –80 GH z –70 26 .8 1 M -50 G Hz Hz -2. 2.9 9G -6. H 5G z, 6.5 Hz DANL and distortion relative to mixer level (dB) 10 MHz to 2.9 GHz 2.9 GHz to 6.46 GHz 6.46 GHz to 13.2 GHz 13.2 GHz to 22.0 GHz 22.0 GHz to 26.8 GHz 26.8 GHz to 31.15 GHz 31.15 GHz to 40 GHz 40 GHz to 50 GHz –40 –30 Mixer Level (dBm) 1.4 –20 5-2 5G –10 Hz 0 Figure 3. Agilent 8560 EC Series nominal dynamic range 1. (1dB compression - DANL) for Option 856xEC-103, degrade compression to noise dynamic range by 10 dB 2. 0.5 x (SHI - DANL at 2 x input frequency) for Option 856xEC-103, degrade harmonic (SHI) dynamic range by 5 dB 3. 0.67 x (TOI - DANL) for Option 856xEC-103, degrade intermodulation (TOI) dynamic range by 6.67 dB 5 Amplitude Specifications, continued Spurious responses General spurious responses (Mixer level –40 dBm) Second harmonic distortion Input signal 20 MHz to 1.45 GHz 1.45 GHz to 2 GHz 2 GHz to 13.25 GHz 8562E, 8563E 8564E, 8565E 13.25 GHz to 25 GHz < (–75 + 20 x logN)1 dBc Mixer level –40 dBm –10 dBm 3 Distortion ≤ –79 dBc 2 ≤ –85 dBc 3 SHI +39 dBm 2 +75 dBm 3 –10 dBm –10 dBm –10 dBm ≤ –100 dBc ≤ –90 dBc ≤ –90 dBc +90 dBm +80 dBm +80 dBm 20 MHz to 2.9 GHz 2.9 GHz to 6.46 GHz 6.46 GHz to 26.8 GHz 26.8 GHz to 50 GHz Mixer level –30 dBm each –30 dBm each –30 dBm each –30 dBm each Distortion ≤ –82 dBc 4 ≤ –90 dBc ≤ –75 dBc ≤ –85 dBc (nominal) TOI +11 dBm +15 dBm +7.5 dBm +12.5 dBm (nominal) Image responses 10 MHz to 26.8 GHz 26.8 GHz to 50 GHz Mixer level –10 dBm –30 dBm –80 dBc –60 dBc Mixer level –10 dBm –30 dBm –80 dBc –55 dBc Third order intermodulation distortion (Two –30 dBm signals, ≥ 1 kHz apart) Multiple and out-of-band responses 10 MHz to 26.8 GHz 26.8 GHz to 50 GHz Residual responses ≤ –90 dBm, for the range from 200 kHz to 6.46 GHz, no input signal, 0 dB input attenuation Display range Viewing area Scale calibration Log scale Linear scale Color display, approximately 9.6 cm (v) x 13 cm (h) 10 x 10 divisions 10, 5, 2, 1 dB per division 10% of reference level per division Scale fidelity Log range RBW ≥ 300 Hz RBW ≤ 100 Hz Linear range Incremental 0 to –90 dB ±0.1 dB/dB ±0.2 dB/2 dB ±3% of reference level Reference level range Log, adjustable in 0.1 dB steps 30 Hz to 31.15 GHz 31.15 GHz to 50 GHz –120 to +30 dBm –115 to +30 dBm Linear, adjustable in 1% steps 30 Hz to 31.15 GHz 31.15 GHz to 50 GHz 2.2 mV to 7.07 V 3.98 mV to 7.07 V 1. 2. 3. 4. 5. 6 Excluding display-related sidebands at multiples of 60 Hz Agilent 8561EC: distortion –72 dBc, SHI +32dBm Agilent 8561EC: mixer level –20 dBm, distortion –72 dBc, SHI +52 dBm Agilent 8561EC –78 dB distortion with two –30 dBm signals, 9 dBm TOI Maximum for 0 to –100 dB is ±1.5 dB Maximum 0 to –90 dB ±0.85 dB ±0.85 dB5 Amplitude Specifications, continued Frequency response in dB, 10 dB input attenuation, dc coupled relative / typical relative / absolute 2 / typical absolute 3 8560EC 8561EC 100 MHz to 2 GHz 0.7/0.7/–/– 30 Hz 1 to 2.9 GHz 1/0.8/1.5/1.0 1.0/0.7/1.75/1.0 2.9 GHz to 6.46.GHz 1.5/1.1/2.5/1.5 6.46 to 13.2 GHz 13.2 to 22 GHz 22 to 26.8 GHz 26.8 to 31.15 GHz 31.15 GHz to 40 GHz (Agilent 8564EC) 31.15 GHz to 50 GHz (Agilent 8565EC) 8562EC 0.9/0.8/–/– 1.25/0.8/1.8/1.0 1.5/1.1/2.5/1.5 2.2/1.5/2.9/2.0 8563EC 1.0/0.8/–/– 1.25/0.8/1.8/1.0 1.5/1.0/2.4/1.5 2.2/1.5/2.9/2.0 2.5/1.5/4.0/2.5 3.3/2.2/4.0/2.5 8564EC, 8565EC 0.9/0.8/–/– 1.0/0.8/1.5/1.0 1.7/1.4/2.6/1.8 2.6/2.2/3.0/2.8 2.5/2.5/4.0/3.5 3.3/2.2/4.5/4.0 3.1/2.9/4.0/3.0 2.6/2.4/4.0/3.2 3.2/3.0/4.0/4.0 Band switching uncertainty ±1 dB (added to relative frequency response for between-band measurements) Calibrator output 300 MHz x (1 ± frequency reference accuracy 4) at –10 dBm ±0.3 dB Input attenuator Switching uncertainty (referenced to 10 dB attenuation) 30 Hz to 2.9 GHz for 20 to 70 dB settings of input attenuator: ±0.6 dB/10 dB step, 1.8 dB maximum Repeatability ±0.1 dB (nominal) IF gain uncertainty ±1 dB (0 to –80 dBm reference levels with 10 dB input attenuation) IF alignment uncertainty ±0.5 dB (additional uncertainty only when using 300 Hz RBW) Resolution bandwidth switching uncertainty ±0.5 dB (relative to 300 kHz RBW) Pulse digitization uncertainty (pulse response mode, PRF > 720/sweep time) Log RBW ≤ 1 MHz < 1.25 dB pk-pk RBW = 2 MHz < 3 dB pk-pk Standard Deviation (RBW < 1 MHz) Linear < 4% of ref level < 12% of ref level < 0.2 dB (nominal) Time-gated spectrum analysis Gate delay 5 Edge mode Range 3 µs to 65.535 ms Resolution 1 µs Accuracy ±1 µs (From GATE TRIGGER INPUT to positive edge of GATE OUTPUT) Gate length Range 1 µs to 65.535 ms Resolution 1 µs Accuracy ±1 µs (From positive edge to negative edge of GATE OUTPUT) 1. 2. 3. 4. 5. Level mode ≤ 0.5 µs Operation below 9 kHz requires Option 856xEC-006 Absolute flatness values referenced to 300 MHz CAL OUT Typical values at 25 °C Frequency reference accuracy = aging x time since last adjustment + initial achievable accuracy + temperature stability Up to 1 µs jitter due to 1 µs resolution of gate delay clock 7 Amplitude Specifications, continued Delayed sweep Trigger modes Range Sweep time < 30 ms Sweep time ≥ 30 ms Resolution Accuracy Free run, line, external, video –9.9 ms to +65.535 ms +2 µs to +65.535 ms 1 µs ±1 µs Demodulation Spectrum demodulation Modulation type Audio output Marker pause time AM and FM Speaker and phone jack with volume control 100 ms to 60 s (nominal) Inputs/Outputs, Agilent 8560 EC Series (All values are nominal) Front panel connectors RF input Agilent 8560EC, 8561EC, 8562EC, 8563EC (Option 856xEC-026, Agilent 8563EC only) Agilent 8564EC, 8565EC VSWR (≥ 10 dB atten) 30 Hz to 2.9 GHz 2.9 GHz to 50 GHz LO emission level (average with 10 dB atten) IF input Frequency Full screen level Gain compression First LO output Frequency Amplitude Cal output Probe power Type N female, 50 Ω APC 3.5 mm male, 50 Ω APC 2.4 mm male, 50 Ω < 1.5:1 dB < 2.3:1 dB ≤ –80 dBm SMA female, 50 Ω 310.7 MHz –30 dBm –23 dB SMA female, 50 Ω 3.000 - 6.8107 GHz +16.5 dBm ±2.0 dB BNC female, 50 Ω +15 Vdc, –12.6 Vdc, and Gnd (150 mA max each) Rear panel connectors Earphone Sub-miniature mono jack, 0.2 W into 4 Ω 10 MHz REF in/out Shared BNC female, 50 Ω Output freq accuracy ±(10 MHz x freq ref accuracy) Output amplitude 0 dBm Input amplitude –2 to +10 dBm Video output BNC, 50 Ω Amplitude (RBW ≥ 300 Hz) 0 to +1 V full scale LO sweep frequency analog voltage output (LO sweep or V/GHz function selectable from the front panel, BNC female, 120 Ω) LO sweep output 0 to 10 V (no load) Frequency analog voltage output (internal mixer mode) Output ramp voltage proportional to start and stop frequencies. Transfer function: 0.5 V/GHz. 0.5 V/GHz output (external mixer mode) Output ramp voltage proportional to LO frequency: (LO = 3 to 6.8107 GHz). Transfer function: (1.5 V/GHz x LO frequency (GHz) –0.2054) ±50 mV (typ). 8 Inputs/Outputs, Agilent 8560 EC Series, continued Blanking/gate Output Blanking mode During sweep During retrace Gate mode Gate on Gate off External/gate Trigger input Shared BNC female, 50 Ω Low TTL level High TTL level High TTL level Low TTL level Shared BNC female, > 10 kΩ Settable to high TTL or low TTL IEEE-488 bus connector SH1, AH1, T6, L4, LE0, RL1, PP1, DC1, DT1, C1, C28, TE0, SR1 Supports HP 3630A PaintJet printer, HP 2225A ThinkJet printer Supports HP 7225A/7440A/7470A/7475A/7550A GPIB Interface functions Direct printer output Direct plotter output Options Option 856xEC-001 second IF output, Agilent 8560 EC Series (all values are nominal) 3 dB bandwidth NF conversion gain 30 Hz to 2.9 GHz 1 2.9 GHz to 6.5 GHz 8560EC 8561EC 8562EC 8563EC 8564EC, 8565EC > 25 MHz 24 dB 1.2 dB > 25 MHz 25 dB –6.5 dB > 30 MHz 26 dB –1 dB > 25 dB 20 dB –1.2 dB > 30 MHz 22 dB –3 dB > 37 MHz 26 dB –5.7 dB > 25 MHz 25 dB –1.2 dB > 30 MHz 22 dB –1 dB > 37 MHz 26 dB –5.7 dB > 45 MHz 30 dB –8 dB > 45 MHz 32 dB –8 dB > 25 MHz 28 dB –1.2 dB > 30 MHz 23 dB –1 dB > 37 MHz 28 dB –5.7 dB > 45 MHz 32 dB –8 dB > 45 MHz 35 dB –8 dB > 25 MHz 28 dB –9 dB > 25 MHz 38 dB –19 dB > 25 MHz 42 dB –23 dB 6.5 GHz to 13.2 GHz 13.2 GHz to 22 GHz 22 GHz to 26.8 GHz 26.8 GHz to31.15 GHz 31.15 GHz to 40 GHz 40 GHz to 50 GHz Option 8560EC-002 Built-in tracking generator 2 Frequency specifications Frequency range Accuracy After peaking Tracking drift (nominal) Minimum RBW 300 kHz to 2.9 GHz ±(frequency reference accuracy x tuned frequency + 5% x span + 295 Hz) Usable in 1 kHz RBW after 5 minutes warm-up. Usable in 300 Hz RBW after 30-minute warm-up. 300 Hz 3 1. DC coupled for frequencies below 100 kHz. Option 856xEC-006 required for operation below 9 kHz in Agilent 8563EC, 8564EC, 8565EC. 2. Option 8560EC-002 is no longer offered. 3. Tracking generator not usable with resolution bandwidths ≤ 100 Hz. 9 Options, continued Amplitude specifications Output level Resolution Accuracy Vernier Absolute Level flatness Effective source match Total absolute accuracy –10 dBm to +1 dBm 10 dBm to +2.8 dBm (typical) 0.1 dB ±0.20 dB, ±0.5 dBm max (25 °C ±10 °C) ±0.75 dB ±2.0 dB 1.92:1 (nominal) ±3.25 dB Spurious output (at +1 dBm output power) Harmonic spurious Non-harmonic spurious 300 kHz to 2.0 GHz 2.0 GHz to 2.9 GHz LO feedthrough Residuals (RF-power-off) –27 dBc –23 dBc –16 dBm (3.9 GHz to 6.8 GHz) –78 dBm (300 kHz to 2.9 GHz Dynamic range TG feedthrough 1 300 kHz to 1 MHz 1 MHz to 2.7 GHz 2.7 GHz to 2.9 GHz –95 dBm –115 dBm –110 dBm Dynamic range 2 300 kHz to 1 MHz 1 MHz to 2.7 GHz 2.7 GHz to 2.9 GHz Power sweep 96 dB 116 dB 111 dB 10 dB range, 0.1 dB resolution Inputs/outputs RF output (front panel) Maximum safe reverse level Type-N female, 50 Ω (nominal) + 30 dBm, ±30 Vdc External ALC input (rear panel) BNC female use with negative detector –25 dBc 1. Leakage measured with maximum power into 50 Ω, with 50 Ω loads on the TG output and RF input. 2. Difference between maximum power output and tracking generator feedthrough. 10 Environmental Specifications, Agilent 8560 EC Series Per MIL- PRF-28800F, Class 3 Calibration interval Agilent 8560EC, 8561EC, 8562EC, 8563EC: Agilent 8564EC, 8565EC: Warm-up time Temperature Humidity Rain resistance Altitude Pulse shock (half sine) Transit drop Electromagnetic compatibility: Power requirements: Maximum power dissipation Agilent 8560EC, 8561EC, 8562EC, 8563EC Agilent 8564EC, 8565EC: Audible noise (nominal): Dimensions (w/o handle, cover): Weight (nominal) Agilent 8560EC, 8561EC, 8562EC, 8563EC: Agilent 8564EC, 8565EC: 2 years 1 year 5 minutes in ambient conditions 0 °C to +55 °C (operating); –40 °C to +75 °C (not operating) 95% @ 40 °C for 5 days Drip-proof at 16 liters/hour/sq. ft. 15,000 ft. (operating), 50,000 ft. (non-operating) 30 g for 11 ms duration 8-inch drop on six faces and eight corners Conducted and radiated interference in compliance with CISPR Pub. 11 (1990). Meets Mil-STD-461C, part 2, with certain exceptions. 115 VAC operation: 90 to 140 V rms, 3.2 A rms max, 47 to 440 Hz 230 VAC operation: 180 to 250 V rms, 1.8 A rms max, 47 to 66 Hz 180 W 260 W < 5.0 Bels power at room temp (ISO DP7779) 337 mm W x 187 mm H x 461 mm D 16.5 kg (36 lbs) 17.3 kg (38 lbs) 11 Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt www.agilent.com For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Latin America United States (877) 894-4414 305 269 7500 (800) 829-4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008 Europe & Middle East Austria Belgium Denmark Finland France 0820 87 44 11 32 (0) 2 404 93 40 45 70 13 15 15 358 (0) 10 855 2100 0825 010 700* *0.125 € fixed network rates Germany 01805 24 6333** **0.14€/minute Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland (French) 41 (21) 8113811(Opt 2) Switzerland (German) 0800 80 53 53 (Opt 1) United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: October 24, 2007 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2001-2008 Printed in USA, February 22, 2008 5968-8156E