VISHAY 90MT80KPBF

90-110MT.KPbF Series
Vishay High Power Products
Three Phase Bridge
(Power Modules), 90/110 A
FEATURES
• Package fully compatible with the industry
standard INT-A-PAK power modules series
• High thermal conductivity package, electrically
insulated case
RoHS
COMPLIANT
• Excellent power volume ratio, outline for easy connections
to power transistor and IGBT modules
• 4000 VRMS isolating voltage
• UL E78996 approved
• Totally lead (Pb)-free
MTK
• Designed and qualified for industrial level
DESCRIPTION
A range of extremely compact, encapsulated three phase
bridge rectifiers offering efficient and reliable operation. They
are intended for use in general purpose and heavy duty
applications.
PRODUCT SUMMARY
IO
90/110 A
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL
IO
IFSM
I2 t
CHARACTERISTICS
TC
TStg
TJ
110MT.K
UNITS
110 (150)
A
°C
90 (61)
90 (57)
50 Hz
770
950
60 Hz
810
1000
50 Hz
3000
4500
60 Hz
2700
4100
30 000
45 000
I2√t
VRRM
90MT.K
90 (120)
A
A2 s
A2√s
Range
800 to 1600
V
Range
- 40 to 150
°C
ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
TYPE NUMBER
90-110MT..K
Document Number: 94352
Revision: 29-Apr-08
VOLTAGE
CODE
VRRM, MAXIMUM
REPETITIVE PEAK
REVERSE VOLTAGE
V
VRSM, MAXIMUM
NON-REPETITIVE PEAK
REVERSE VOLTAGE
V
80
800
900
100
1000
1100
120
1200
1300
140
1400
1500
160
1600
1700
For technical questions, contact: [email protected]
IRRM MAXIMUM
AT TJ = MAXIMUM
mA
10
www.vishay.com
1
90-110MT.KPbF Series
Vishay High Power Products
Three Phase Bridge
(Power Modules), 90/110 A
FORWARD CONDUCTION
PARAMETER
SYMBOL
Maximum DC output current at case
temperature
IO
TEST CONDITIONS
120° rect. conduction angle
t = 10 ms
Maximum peak, one-cycle
forward, non-repetitive surge current
IFSM
t = 8.3 ms
t = 10 ms
t = 8.3 ms
t = 10 ms
Maximum I2t for fusing
I2t
t = 8.3 ms
t = 10 ms
t = 8.3 ms
Maximum
I2√t
I2√t
for fusing
No voltage
reapplied
100 % VRRM
reapplied
No voltage
reapplied
Initial
TJ = TJ maximum
100 % VRRM
reapplied
t = 0.1 to 10 ms, no voltage reapplied
90MT.K
110MT.K
UNITS
90 (120)
110 (150)
A
90 (61)
90 (57)
°C
770
950
810
1000
650
800
680
840
3000
4500
2700
4100
2100
3200
1900
2900
30 000
45 000
Low level value of
threshold voltage
VF(TO)1
(16.7 % x π x IF(AV) < I < π x IF(AV)), TJ maximum
0.89
0.81
High level value of threshold voltage
VF(TO)2
(I > π x IF(AV)), TJ maximum
1.05
0.99
5.11
4.37
Low level value of forward
slope resistance
rf1
(16.7 % x π x IF(AV) < I < π x IF(AV)), TJ maximum
High level value of forward
slope resistance
rf2
(I > π x IF(AV)), TJ maximum
A
A2 s
A2√s
V
mΩ
Maximum forward voltage drop
RMS isolation voltage
VFM
VISOL
Ipk = 150 A, TJ = 25 °C
tp = 400 µs single junction
4.64
1.6
1.4
V
TJ = 25 °C, all terminal shorted
f = 50 Hz, t = 1 s
4000
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER
SYMBOL
Maximum junction operating and
storage temperature range
TEST CONDITIONS
TJ, TStg
Maximum thermal resistance,
case to heatsink per module
Mounting
torque ± 10 %
Approximate weight
www.vishay.com
2
to heatsink
to terminal
RthJC
RthCS
110MT.K
- 40 to 150
DC operation per module
Maximum thermal resistance,
junction to case
90MT.K
0.21
°C
0.18
DC operation per junction
1.26
1.07
120° rect. conduction angle per module
0.25
0.21
120° rect. conduction angle per junction
1.47
1.25
Mounting surface smooth, flat and greased
0.03
A mounting compound is recommended and
the torque should be rechecked after a period
of 3 hours to allow for the spread of the
compound. Lubricated threads.
4 to 6
For technical questions, contact: [email protected]
UNITS
3 to 4
176
°C/W
Nm
g
Document Number: 94352
Revision: 29-Apr-08
90-110MT.KPbF Series
150
Instantaneous Forward Current (A)
Three Phase Bridge
Vishay High Power Products
(Power Modules), 90/110 A
90MT..K Series
Maximum Allowable Case
Temperature (°C)
140
130
120
120°
(Rect)
110
100
90
+
80
~
70
-
60
50
0
25
50
75
100
1000
100
TJ = 25 °C
TJ = 150 °C
10
90MT..K Series
Per junction
1
0
125
Total Output Current (A)
Fig. 1 - Current Ratings Characteristics
2
3
4
5
Instantaneous Forward Voltage (V)
Fig. 2 - Forward Voltage Drop Characteristics
400
350
Maximum Total Power Loss (W)
400
Maximum Total Power Loss (W)
1
90MT..K Series
TJ = 150 °C
300
250
120°
(Rect)
200
150
100
50
R
0.
12
350
W
0.2
300
0.3
250
K/
th
SA
=
W
0.0
150
0.7
K/
W
K/W
200
0.
05
K/
-Δ
R
5K
/W
K/W
100
1.0 K
50
1.5 K/W
/W
0
0
0
20
40
60
80
100
0
120
25
50
75
100
125
150
Maximum Allowable Ambient
Temperature (°C)
Total Output Current (A)
Fig. 3 - Total Power Loss Characteristics
700
Peak Half Sine Wave
Forward Current (A)
600
550
Peal Half Sine Wave
Forward Current (A)
At any rated load condition and with
rated VRRM applied following surge.
Initial TJ = 150 °C
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
650
500
450
400
350
300
90MT..K Series
250
200
1
10
100
800
Maximum non-repetitive surge current
750
versus pulse train duration.
700
Initial TJ = 150 °C
No voltage reapplied
650
Rated VRRM reapplied
600
550
500
450
400
350
300
250
90MT..K Series
200
150
0.01
0.1
1.0
Number of Equal Amplitude Half
Cycle Current Pulses (N)
Pulse Train Duration (s)
Fig. 4 - Maximum Non-Repetitive Surge Current
Fig. 5 - Maximum Non-Repetitive Surge Current
Document Number: 94352
Revision: 29-Apr-08
For technical questions, contact: [email protected]
www.vishay.com
3
90-110MT.KPbF Series
150
Three Phase Bridge
(Power Modules), 90/110 A
Instantaneous Forward Current (A)
Vishay High Power Products
110MT..K Series
Maximum Allowable Case
Temperature (°C)
140
130
120
120°
(Rect)
110
100
90
80
+
70
~
60
-
50
0
20
40
60
80
100
120
140
1000
100
TJ = 25 °C
TJ = 150 °C
10
110MT..K Series
Per junction
1
0
160
2
3
4
5
Instantaneous Forward Voltage (V)
Fig. 7 - Forward Voltage Drop Characteristics
Total Output Current (A)
Fig. 6 - Current Ratings Characteristics
450
450
110MT..K Series
TJ = 150 °C
400
Maximum Total Power Loss (W)
Maximum Total Power Loss (W)
1
350
120°
(Rect)
300
250
200
150
100
50
400
R
0.
12
350
0.2
300
0.3
250
0.4
200
0.5
th
K/
SA
=
W
0.
05
K/W
K/
W
K/W
-Δ
R
K/W
K/W
0.7
K/W
1.0 K
/W
150
100
1.5 K
50
/W
0
0
0
25
50
75
100
125
0
150
25
50
75
100
125
150
Maximum Allowable Ambient
Temperature (°C)
Total Output Current (A)
Fig. 8 - Total Power Loss Characteristics
900
700
Peak Half Sine Wave
Forward Current (A)
800
Peak Half Sine Wave
Forward Current (A)
1000
At any rated load condition and with
rated VRRM applied following surge.
Initial TJ = 150 °C
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
600
500
400
300
Maximum non-repetitive surge current
versus pulse train duration.
Initial TJ = 150 °C
No voltage reapplied
Rated VRRM reapplied
100
10
110MT..K Series
110MT..K Series
1
200
1
10
100
0
0.2
0.4
0.6
0.8
1.0
1.2
Number of Equal Amplitude Half
Cycle Current Pulses (N)
Pulse Train Duration (s)
Fig. 9 - Maximum Non-Repetitive Surge Current
Fig. 10 - Maximum Non-Repetitive Surge Current
www.vishay.com
4
For technical questions, contact: [email protected]
Document Number: 94352
Revision: 29-Apr-08
90-110MT.KPbF Series
Three Phase Bridge
Vishay High Power Products
(Power Modules), 90/110 A
10
ZthJC - Transient Thermal
Impedance (°C/W)
Steady state value
RthJC = 1.26 K/W
90MT..K Series
RthJC = 1.07 K/W
1
(DC operation)
110MT..K Series
0.1
Per junction
0.01
0.001
0.01
0.1
1
10
Square Wave Pulse Duration (s)
Fig. 11 - Thermal Impedance ZthJC Characteristic
ORDERING INFORMATION TABLE
Device code
11
0
1
2
MT 160
3
K
PbF
4
5
1
-
Current rating code: 9 = 90 A (average)
11 = 110 A (average)
2
-
Three phase diodes bridge
3
4
-
Essential part number
Voltage code x 10 = VRRM (see Voltage Ratings table)
5
-
PbF = Lead (Pb)-free
Note
• To order the optional hardware go to www.vishay.com/doc?95172
CIRCUIT CONFIGURATION
+ D
A
B
~
C
-
E
F
LINKS TO RELATED DOCUMENTS
Dimensions and pin out positions
Document Number: 94352
Revision: 29-Apr-08
http://www.vishay.com/doc?95004
For technical questions, contact: [email protected]
www.vishay.com
5
Legal Disclaimer Notice
Vishay
Disclaimer
All product specifications and data are subject to change without notice.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein
or in any other disclosure relating to any product.
Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any
information provided herein to the maximum extent permitted by law. The product specifications do not expand or
otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed
therein, which apply to these products.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Vishay.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless
otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such
applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting
from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding
products designed for such applications.
Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 18-Jul-08
www.vishay.com
1