ETC 18RA-6

Terminals
Why Sta-Kon Terminals Are Better
Like any other value added manufacturing process, using the best
material is only a start. Our StaKon terminals are all manufactured with the customer in mind,
not a price tag! The following
product features are usually
absent in competitive products.
Chamfered/Funneled
Terminal Barrel Entry
This feature makes wire insertion
faster and easier. Chamfering
eliminates wire strand “hang up”
and departure upon insertion into
the terminal’s barrel. The loss of
even a couple of wire strands can
have negative results on electrical
efficiency and resistance to
mechanical strain.
Sta-Kon’s Long Barrel Design
If lowering electrical resistance,
preventing wire pullout, eliminating a “missed” crimp and an insulator that stays on the barrel during installation are your goals,
then, you must design a terminal
with a long barrel. The fact is that
most competitive barrel lengths
range from 20%-50% shorter
than the Sta-Kon. The results are
usually a stream of electrical failure, rework and added expense.
This also provides the insulator
with additional surface area, holding tight to the barrel. Many competitive insulators come off during
crimping due to a limited barrel
length.
able on most 1-piece Sta-Kon terminals:
Platings/Finish
Deep Internal Serrations
After the insertion of a wire into
the terminal’s barrel, a deep serrated interior insures a large area
of contact which lowers the resistance of a connection. Upon the
mechanical force of tool applied
pressure, the wire strands cold
flow into the serrated interior.
This guarantees electrical resistance lower than the wire to
which it is applied. This feature
also prevents pullout from vibration and mechanical strain. Deep
internal serrations can be compared to the effective holding
power of a well treaded tire on a
wet highway.
Electroplated-Tin is standard. All
others require minimum order
quantities and are generally not
stocked. Alternative platings as
follows: Gold, Silver, Tin-alloys,
Finish
Suffix
Spec.
Gold Plate
GP
Nickel Plate
Plain Finish
Silver Plate
Tin Plate
NP
PF
SP
TP
MIL-G-45204 Type II, Grade B, C, D, Class
O
QQ-N-290 Class 2, Grade G
None
MIL-T-16366 Type I or II, 400°F, 204°C
MIL-T-10727 Type I
To order add the indicated suffix to the regular catalog number.
Nickel, etc.
The following finishes are avail-
Telecom 1-800-685-9452
75
Terminals
Why Sta-Kon Terminals Are Better—continued
Anti-Rotational Tongues
er electrical flow, void free.
This is a unique feature to the
Thomas & Betts ring tongue terminal. This design prevents terminal shorting by keeping the terminal secure in the terminal block.
The installer can place a greater
number of terminals, closer
together without worry.
Selective Annealing
Because of the mechanical
strength of copper, an installer
can experience fatigue associated
with repeated installations. For
this reason Thomas & Betts puts
our terminals through one more
step called selective annealing.
This process leaves the barrel
soft enough to crimp and form
around the wire. However, we
“cold form” the tongue during the
manufacturing process so it
remains strong. This is done so
the tongue can withstand repeated
bends and bolt tightening strain
common in most electrical installations. Many competitors attempt
to accomplish similar goals by
removing valuable material or
using a softer copper which has
lower conductivity. This increases
electrical resistance as well as
the odds for shorting and downtime.
Brazed or Overlapped Seam
A long barrel design is of little
value unless it is one solid piece.
That is why Thomas & Betts
brazes the seam on our vinyl insulated Sta-Kon and overlaps the
seam on nylon insulated terminals.
Many competitive terminals have
butted seams. This means
increased chances for wirestrand
loss, poor resistance, wire pullout
and electrical failure. If the
installer doesn’t position the tool
exactly on the correct spot on the
barrel, there’s likely going to be
an improper termination. The
butted seam can also fold due to
tool-applied pressure piercing the
terminals insulation from the
inside out. With a brazed or overlapped seam the installer can
crimp anywhere along the barrel’s
surface providing up to 21⁄2 times
the tensile strength of a butted
seam terminal, guaranteeing prop-
76
Telecom 1-800-685-9452
Terminals
Thomas & Betts developed the first tool-applied solderless terminals
and connectors nearly 50 years ago in response to industry awareness
of the need for better performance of electrical systems.
Today, sophisticated electrical and electronic equipment requires an
even higher degree of reliability.
Here are key factors built into the Sta-Kon terminal and connector
line that deliver this reliability:
•
Broad product selection
•
Job suited tooling
•
Testing and approvals
•
Field proven performance
•
New product development
•
Service and availability
Sta-Kon® Technical Data
center reinforced spring
detent for minimum
insertion force
Terminals & Splices
Insulation Rating
flat bottom box
funneled
wire entrance
extra-length
insulation
sleeve
brazed
seam
Nylon
Vinyl
TEFZEL*
**1000V fixture or sign
Disconnects
U.L. 94
Flammability
Voltage
Temperature
V-2
V-0
V-0
600V**
600V**
600V**
1 0 5°C
1 0 5°C
1 5 0°C
300V
1 0 5°C
electro
tin plate
complete
identification
compound spring rails provide positive
contact after repeated insertions &
crimp produces
even compression
forces on insulation
and stranding
Sta-Kon® Disconnects
•
Internal barrel serrations and long barrel provide for maximum
tensile strength
•
Complete line of installing tools, engineered to match tool with
terminal
•
Funnel entry insulators allow for easier inserting of wire into
barrel
•
Color-coded for easy installation
selectively annealed
long barrel
color-coded TEFZEL*,
Nylon, or Vinyl
complete wire & stud
size identification
anti-rotational
tongue
vinyl brazed seam, or
NYLON/TEFZEL*
insulated grip sleeve
strands enter as a
homogeneous group and
compact tightly under
compression due to fully
brazed seam
serrated inner barrel
for maximum contact &
tensile strength
hardened tongue
Sta-Kon® Ring, fork & locking fork
•
Complete line of installing tools engineered to match tool with
terminal
•
First to gain military approval for pressure connections … many
styles available for military applications
•
Sta-Kon products exceed test specification requirements of military, U.L. and CSA
•
TEFZEL* & Nylon Terminals provided with extra metal sleeve to
grip insulation
•
Vinyl insulated and bare Sta-Kons feature brazed seam wire
barrels which can be crimped at any place on the barrel circumference
The Shure Stake® tools are matched to terminals
ERG-2001
Telecom 1-800-685-9452
The Shure Stake mechanism prevents the dies from releasing the terminal until the proper compression has been completed.
With this method, an operator achieves a reliable crimp everytime.
77
Terminals
Performance Data
CODE
Typical test
value
of T&B
Terminals
30
28
The proper installation of terminals, splices and connectors is
very important to the efficient
performance of an electrical system. The properly installed connector will allow good conductivity through the termination. A
poor termination results in a high
resistance connection. A poor
connector installation may cause
damage or failure of an entire
system. Certain basic requirements must be met to make a good
termination.
1.
Before the connector or
terminal is installed on the conductor, follow these recommended practices:
•
Strip the insulation carefully so as to avoid nicking or
cutting conductor strands
•
Strip the insulation to the
proper length so that the conductors can be inserted fully
into the connector barrel; the
wire/cable should be visible in
the inspection hole of the lug;
the proper strip length can be
found on page 49D.
2.
Thomas & Betts wire
strippers will help eliminate
these
problems
stripping
by
length
NEMA
requirement
24
Voltage Drop (mv)
The Proper Installation
Procedure for the Quality
Assured Connection
20
16
12
8
4
0
8
22
16
20 18
24
16
32
14
40
12
48
10
AMPS
AWG
Voltage Drop Test 500 Cycles
Thomas & Betts terminals show consistently lower millivolt drops than those allowed by NEMA specification.
CODE
Typical test
value of
T&B Terminals
120
100
NEMA requirement
Wire Pullout Force (lbs.)
80
60
stripped wire
40
rest
20
18
16
14
Wire Size (AWG)
12
properly
gaging
terminal
and
meaorient tongue
as shown suring
the depth and
length requirements for the
conductor. See page 44D for
wire strippers.
0
22
indentor
10
Wire Pullout Tension Test
Thomas & Betts terminals show consistently higher wire retention forces than those required by NEMA
specification.
78
Telecom 1-800-685-9452
Terminals
The Sta-Kon® Terminal Numbering System
Distributor Package 100/50
Bulk “O.E.M.” Packaged 1000/500
Common to Both Packages
• Letter A denotes 22-18 AWG wire
range
• Letter B denotes 16-14 AWG wire
range
• Letter C denotes 12-10 AWG wire
range
• Letter R preceding the above letters indicates the terminal is insulated
• No letter R… no insulation … no
exception!
Distributor Packaged
Part numbers are very descriptive
indicating insulation and type, stud
size, tongue style and the largest
maximum wire that can be put
inside.
• If the letter R precedes the number
the part is nylon insulated—RA18-6
• If the letter R follows the number
the part is vinyl insulated—14RB-8
stripping
length
stripped wire
indentor
terminal
rest
Telecom 1-800-685-9452
orient tongue
as shown
79
Installation Procedure
1.
Twist the wires to
eliminate fanning of strands.
2.
Open tool handles fully.
3.
Insert terminal in proper die nest and locate it as
shown above. When crimping a
butt splice, position in proper
die nest with window facing
indentor.
4.
Close handles slightly to
secure terminal. Do not
deform terminal.
5.
Insert properly stripped
wire into terminal.
6.
Complete crimp by closing handles.
Nylon Terminals
®
Nylon Insulated Ring—Insulation Grip
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
100
100
100
100
100
26-22
26-22
26-22
26-22
26-22
.083
.083
.083
.083
.083
#2
#4
#6
#8
#10
1
1
1
1
1
.57
.65
.65
.75
.75
.14
.21
.21
.25
.25
.13
.20
.20
.23
.23
.49
.54
.54
.62
.62
RAX23*
RAX43*
RAX63*
RAX83*
RAX103*
1000
1000
1000
1000
1000
26-24
26-24
26-24
26-24
26-24
.125
.125
.125
.125
.125
#2
#4
#6
#8
#10
3
3
3
3
3
.66
.74
.84
.84
.84
.14
.20
.25
.25
.25
.14
.19
.22
.22
.24
.59
.64
.72
.72
.72
RA18-4
RA323
RA333
RA18-6
RA853
RA18-8
RA833
RA863
RA18-10
RA873
RA18-14
RA713
RA18-516
RA723
RA18-38
RA733
RA18-12
RA753
100
1000
1000
100
1000
100
1000
1000
100
1000
100
1000
100
1000
100
1000
100
1000
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
.136
.136
.136
.136
.136
.136
.136
.136
.136
.136
.136
.136
.136
.136
.136
.136
.136
.136
#4
#4
#6
#6
#6
#8
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
1
⁄
2"
2
2
2
2
2
3
3
3
2
2
3
3
3
3
3
3
3
3
.70
.70
.70
.83
.83
.83
.83
.83
.86
.86
1.07
1.07
1.07
1.07
1.17
1.17
1.27
1.27
.23
.23
.23
.26
.26
.26
.26
.26
.31
.31
.46
.46
.46
.46
.53
.53
.72
.72
.14
.14
.14
.25
.25
.25
.25
.25
.25
.25
.31
.31
.31
.31
.35
.35
.50
.50
.59
.59
.59
.71
.71
.71
.71
.71
.71
.71
.84
.84
.84
.84
.87
.87
.92
.92
RB14-4
RB1323
RB14-6
RB853
RB1333
RB14-8
RB863
RB14-10
RB873
RB14-14
RB713
RB14-516
RB723
RB14-38
RB733
RB14-12
RB753
100
1000
100
1000
1000
100
1000
100
1000
100
1000
100
1000
100
1000
100
1000
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
.162
.162
.162
.162
.162
.162
.162
.162
.162
.162
.162
.162
.162
.162
.162
.162
.162
#4
#4
#6
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
1
⁄
2"
2 1⁄
2
2 1⁄
2
3
3
3
3
3
3 1⁄
2
3 1⁄
2
1
3⁄
2
1
3⁄
2
1
3⁄
2
1
3⁄
2
1
3⁄
2
1
3⁄
2
4
4
.72
.72
.89
.89
.74
.89
.89
.89
.89
1.08
1.08
1.08
1.08
1.17
1.17
1.25
1.25
.26
.26
.31
.31
.26
.31
.31
.31
.31
.47
.47
.47
.47
.53
.53
.72
.72
.14
.14
.25
.25
.14
.25
.25
.25
.25
.31
.31
.31
.31
.35
.35
.50
.50
.59
.59
.71
.71
.59
.71
.71
.71
.71
.81
.81
.84
.84
.87
.87
.90
.90
RC10-6
RC333
RC10-8
RC863
RC10-10
RC363
RC10-14
RC713
RC10-516
RC703
RC10-38
RC733
RC10-12
RC753
50
500
50
500
50
500
50
500
50
500
50
500
50
500
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
.210
.210
.210
.210
.210
.210
.210
.210
.210
.210
.210
.210
.210
.210
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
1
⁄
2"
3
3
5
5
5
5
6
6
6
6
6
6
6
6
1.00
1.00
1.00
1.00
1.00
1.00
1.12
1.12
1.21
1.21
1.27
1.27
1.37
1.37
.37
.37
.37
.37
.37
.37
.53
.53
.53
.53
.59
.59
.72
.72
.27
.27
.27
.27
.27
.27
.32
.32
.31
.31
.35
.35
.52
.52
.81
.81
.81
.81
.81
.81
.86
.86
.94
.94
.98
.98
1.02
1.02
Cat.
No.
RZ22-2**
RZ22-4**
RZ22-6**
RZ22-8**
RZ22-10**
Self-insulated with high dieletric-strength nylon
sleeves, these ring terminals are recommended
for temperatures up to 105°C. An inner bronze
insulation grip sleeve lengthens the flexing
radius of the conductor and eliminates conductor creep. The nylon jacket is color-coded:
Color Code
Wire Range
yellow
26-22
red
22-16
blue
18-14
yellow
12-10
Most standard bulk catalog numbers can
be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies).
Please consult tech service.
Please put the suffix M for Mylar Tape
RA2573M.
(Bulk number 1000 and 500 packages.)
RZ & RAX stock thickness: .02
RA & RB stock thickness: .03
RC stock thickness: .04
®
Dimensions
* Not Listed By U.L. CSA
** CSA Listed only
U.L. Listed E9809
Installing tools: WT2000, WT112M, WT145C, WT1455, ERG-2001, ERG-2003,
WT145A, WT2130A (RC,RBC)
Installing tool: WT1452 (RZ series only)
80
Telecom 1-800-685-9452
Nylon Terminals
Nylon Insulated Ring—Expanded Insulation Grip
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
RB14-4X
100
RB1324
1000
RB14-6X
100
RB854
1000
RB14-8X
100
RB864
1000
RB14-10X 100
RB874
1000
RB14-14X 100
RB714
1000
RB14-516X 100
RB724
1000
RB14-38X 100
RB734
1000
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
.190
.190
.190
.190
.190
.190
.190
.190
.190
.190
.190
.190
.190
.190
#4
#4
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
4
4
4
4
5
5
5
5
6
6
6
6
6
6
.80
.80
.95
.95
.95
.95
.95
.95
1.16
1.16
1.16
1.16
1.25
1.25
.26
.26
.31
.31
.31
.31
.31
.31
.47
.47
.47
.47
.53
.53
.14
.14
.25
.25
.25
.25
.25
.25
.31
.31
.31
.31
.42
.42
.67
.67
.79
.79
.79
.79
.79
.79
.92
.92
.92
.92
.95
.95
RC10-6X
RC334
RC10-8X
RC864
RC10-10X
RC364
RC10-14X
RC714
RC10-516X
RC704
RC10-38X
RC734
RC10-12X
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
.250
.250
.250
.250
.250
.250
.250
.250
.250
.250
.250
.250
.250
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
5
5
5
5
5
5
6
6
6
6
6
6
6
1.10
1.10
1.10
1.10
1.10
1.10
1.22
1.22
1.32
1.32
1.38
1.38
1.48
.37
.37
.37
.37
.37
.37
.53
.53
.53
.53
.59
.59
.72
.27
.27
.27
.27
.27
.27
.32
.32
.31
.31
.35
.35
.52
.91
.91
.91
.91
.91
.91
.96
.96
1.05
1.05
1.09
1.09
1.13
Cat.
No.
Catalog numbers with the suffix X indicate an
expanded insulation grip. This means a wider
wire entry to accommodate heavy wall insulation. Ring terminals won’t fall free even if the
mounting screw loosens.
RB stock thickness: .03
RC stock thickness: .04
®
®
50
500
50
500
50
500
50
500
50
500
50
500
50
Dimensions
U.L. Listed E9809
Installing tools: WT2000, WT112M, WT145C, ERG-2001, ERG-2003, WT145A,
WT2130A(RC)
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications
(i.e. 12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
Telecom 1-800-685-9452
81
Nylon Terminals
®
Nylon Insulated Ring
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
RD8-10
RD367
RD8-14
RD717
RD8-516
RD727
RD8-38
RD737
RD8-12
RD757*
25
200
25
200
25
200
25
200
25
200
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
.340
.340
.340
.340
.340
.340
.340
.340
.310
.310
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
1
⁄
2"
12
12
12
12
12
12
12
12
12
12
1.48
1.48
1.54
1.54
1.63
1.63
1.63
1.63
1.79
1.79
.42
.42
.46
.46
.57
.57
.57
.57
.82
.82
.28
.28
.36
.36
.36
.36
.36
.36
.55
.55
1.29
1.29
1.32
1.32
1.35
1.35
1.35
1.35
1.39
1.39
RD10161
RD10361
RD10711
RD10721
RD10731
200
200
200
200
200
9-8-7AN
9-8-7AN
9-8-7AN
9-8-7AN
9-8-7AN
.270
.270
.270
.270
.270
#8
#10
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
12
12
12
12
12
1.40
1.40
1.45
1.53
1.53
.41
.41
.45
.56
.56
.24
.24
.27
.34
.34
1.20
1.20
1.22
1.25
1.25
RE6-10
RE267
RE6-14
RE717
RE6-516
RE727
RE6-38
RE737
RE6-12
RE757*
20
200
20
200
20
200
20
200
20
200
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
.420
.420
.420
.420
.420
.420
.420
.420
.395
.395
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
1
⁄
2"
16
16
16
16
16
16
16
16
16
16
1.65
1.65
1.65
1.65
1.76
1.76
1.76
1.76
1.83
1.83
.49
.49
.49
.49
.61
.61
.61
.61
.82
.82
.28
.28
.28
.28
.34
.34
.34
.34
.55
.55
1.40
1.40
1.40
1.40
1.47
1.47
1.47
1.47
1.43
1.43
RE10261
RE10711
RE10721
RE10731
200
200
200
200
6-5AN
6-5AN
6-5AN
6-5AN
.315
.315
.315
.315
#10
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
16
16
16
16
1.55
1.55
1.70
1.70
.49
.49
.60
.60
.24
.27
.34
.34
1.31
1.31
1.40
1.40
RF4-10
RF267
RF4-14
RF717
RF4-516
RF727
RF4-38
RF737
RF757*
15
200
15
200
15
200
15
200
200
4-3
4-3
4-3
4-3
4-3
4-3
4-3
4-3
4-3
.510
.510
.510
.510
.510
.510
.510
.510
.500
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
21
21
21
21
21
21
23
23
23
1.76
1.76
1.76
1.76
1.84
1.84
1.84
1.84
1.90
.56
.56
.56
.56
.62
.62
.62
.62
.82
.36
.36
.36
.36
.35
.35
.35
.35
.55
1.49
1.49
1.49
1.49
1.53
1.53
1.53
1.53
1.49
RF10261
RF10711
RF10721
RF10731
200
200
200
200
4-3AN
4-3AN
4-3AN
4-3AN
.380
.380
.380
.380
#10
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
26
26
26
26
1.78
1.78
1.80
1.80
.55
.55
.62
.82
.30
.30
.34
.34
1.51
1.51
1.49
1.49
RG2-10
RG267
RG2-14
RG717
RG2-516
RG727
RG2-38
RG737
RG2-12
RG757
10
100
10
100
10
100
10
100
10
100
2-1
2-1
2-1
2-1
2-1
2-1
2-1
2-1
2-1
2-1
.588
.588
.588
.588
.588
.588
.588
.588
.588
.588
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
1
⁄
2"
42
42
42
42
42
42
42
42
42
42
2.15
2.15
2.15
2.15
2.15
2.15
2.15
2.15
2.35
2.35
.69
.69
.69
.69
.69
.69
.69
.69
.80
.80
.40
.40
.40
.40
.40
.40
.40
.40
.49
.49
1.83
1.83
1.83
1.83
1.83
1.83
1.83
1.83
1.93
1.93
RG9711
RG9731
RG9751
100
100
100
2AN
2AN
2AN
453
.453
.453
48
48
48
2.07
2.07
2.26
.69
.69
.80
.40
.40
.49
1.74
1.74
1.84
Cat.
No.
C
RD, RE, RF stock thickness: .04
RG stock thickness: .05
* Brazed Seam, Lolly-Pop Style Tongue
®
1
4
3
8
1
2
⁄"
⁄"
⁄"
Dimensions
AN—Aircraft Wire
U.L. Listed E9809
Installing tools: TBM6/TBM6S, WT2130A (RD Series only)
Note: Not available on Mylar Tape.
82
Telecom 1-800-685-9452
Nylon Terminals
®
Nylon Insulated Ring—continued
Stock Thickness:
RH = .05
RJ = .06
RK = .06
RL = .07
RM = .07
®
Wt./Lbs.
Per
1000
A
B
C
M
1
4
3
8
1
2
54
54
54
2.14
2.14
2.34
.77
.77
.77
.44
.44
.54
1.81
1.81
1.90
.550
.550
.550
1
4
3
8
1
2
80
80
80
2.35
2.35
2.49
.83
.83
.89
.46
.46
.55
1.97
1.97
2.04
1/0
1/0
1/0
1/0
.629
.629
.629
.629
1
4
5
16
3
8
1
2
⁄"
⁄"
⁄"
⁄"
80
80
80
80
2.14
2.14
2.14
2.34
.77
.77
.77
.77
.43
.43
.43
.54
1.81
1.81
1.81
1.90
100
100
2/0AN
2/0AN
.610
.610
3
8
1
2
70
70
2.52
2.60
.93
.93
.55
.55
2.14
2.15
RJ717
RJ727
RJ737
RJ757
100
100
100
100
2/0
2/0
2/0
2/0
.675
.675
.675
.675
1
4
5
16
3
8
1
2
80
80
80
80
2.34
2.34
2.34
2.48
.83
.83
.83
.89
.46
.46
.46
.54
1.96
1.96
1.96
2.03
RL9731
RL9751
100
100
3/0AN
3/0AN
.680
.680
3
8
1
2
120
120
2.83
2.83
1.04
1.04
.57
.57
2.36
2.36
RK717
RK727
RK737
100
100
100
3/0
3/0
3/0
.765
.765
.765
1
4
5
16
3
8
84
84
84
2.60
2.60
2.60
.93
.93
.93
.54
.54
.54
2.21
2.21
2.21
RM9731
RM9751
100
100
4/0AN
4/0AN
.750
.750
3
8
1
2
160
160
3.00
3.00
1.13
1.13
.66
.66
2.51
2.51
RL737
RL757
100
100
4/0
4/0
.785
.785
3
8
1
2
130
130
2.83
2.83
1.04
1.04
.57
.57
2.35
2.35
RM737
RM747
RM757
100
100
100
250MCM
250MCM
250MCM
.868
.868
.868
3
8
7
16
1
2
130
130
130
3.00
3.00
3.00
1.13
1.13
1.13
.65
.65
.65
2.51
2.51
2.51
Cat.
No.
Pkg.
Qty.
Wire
Range
Max.
Ins.
RH9711
RH9731
RH9751
100
100
100
1AN
1AN
1AN
.500
.500
.500
RJ9711
RJ9731
RJ9751
100
100
100
1/0AN
1/0AN
1/0AN
RH717
RH727
RH737
RH757
100
100
100
100
RK9731
RK9751
Bolt
Hole
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
Dimensions
A N—Aircraft Wire
U.L. Listed E9809
Installing tools: TBM6/TBM6S, WT2130A (RD Series only)
Note: Not available on Mylar Tape.
Telecom 1-800-685-9452
83
Terminals
®
®
Heat Shrinkable Ring Terminals—Expanded Insulation Support
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
RAS18-6X 100
RAS18-8X 100
RAS18-10X 100
22-18
22-18
22-18
.170
.170
.170
#6
#8
#10
2
3
2
1.23
1.26
1.26
.25
.31
.31
.27
.27
.27
1.10
1.10
1.10
RBS14-6X 100
RBS14-8X 100
RBS14-10X 100
16-14
16-14
16-14
.200
.200
.200
#6
#8
#10
3
3
3 1⁄
2
1.23
1.23
1.26
.25
.25
.31
.27
.27
.27
1.10
1.10
1.10
RCS10-6X
RCS10-8X
RCS10-10X
RCS10-14X
12-10
12-10
12-10
12-10
.250
.250
.250
.250
#6
#8
#10
1
⁄
4"
3
5
5
6
1.34
1.34
1.34
1.34
.31
.37
.37
.49
.27
.27
.27
.32
1.15
1.15
1.15
1.15
Cat.
No.
These ring terminals are self-insulated with
heat shrinkable nylon and internally coated
sealant. Upon completed installation, a fully
sealed connection is achieved to protect the
joint against the degrading effects of galvanic
action, corrosion, and environmental exposure.
RAS & RBS stock thickness: .03
RCS stock thickness: .04
50
50
50
50
Dimensions
U.L. Listed E9809
Installing tool: WT1255
Note: Not available on Mylar Tape.
84
Telecom 1-800-685-9452
Vinyl Terminals
®
Vinyl Insulated Ring—Insulation Support
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
18RA-4
100
RA77
1000
18RA-6
100
RA857
1000
18RA-8
100
RA867
1000
18RA-10 100
RA877
1000
18RA-14 100
RA717
1000
18RA-516 100
RA727
1000
18RA-38 100
RA737
1000
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
.150
.150
.150
.150
.150
.150
.150
.150
.150
.150
.150
.150
.150
.150
#4
#4
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
3
3
3
3
3
3
3
3
4
4
4
4
4
4
.97
.97
.94
.94
.97
.97
.97
.97
1.13
1.13
1.13
1.13
1.24
1.24
.31
.31
.25
.25
.31
.31
.31
.31
.50
.50
.50
.50
.54
.54
.27
.27
.27
.27
.27
.27
.27
.27
.37
.37
.37
.37
.37
.37
.81
.81
.81
.81
.81
.81
.81
.81
.88
.88
.88
.88
.91
.91
14RB-4
100
RB1327 1000
14RB-6
100
RB857
1000
14RB-8
100
RB867
1000
14RB-10 100
RB877
1000
14RB-14 100
RB717
1000
14RB-516 100
RB727
1000
14RB-38 100
RB-737 1000
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
.170
.170
.170
.170
.170
.170
.170
.170
.170
.170
.170
.170
.170
.170
#4
#4
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
3
3
3
3
3
3
3
3
4
4
4
4
4
4
.94
.94
.97
.97
.97
.97
.97
.97
1.14
1.14
1.15
1.15
1.16
1.16
.25
.25
.31
.31
.31
.31
.31
.31
.50
.50
.50
.50
.54
.54
.27
.27
.27
.27
.27
.27
.27
.27
.38
.38
.38
.38
.38
.38
.81
.81
.81
.81
.81
.81
.81
.81
.89
.89
.89
.89
.91
.91
10RC-6
RC337
10RC-8
RC777
10RC-10
RC367
10RC-14
RC717
10RC-516
RC707
10RC-38
RC737
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
.210
.210
.210
.210
.210
.210
.210
.210
.210
.210
.210
.210
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
5
5
5
5
5
5
6
6
6
6
6
6
1.06
1.06
1.06
1.06
1.06
1.06
1.16
1.16
1.17
1.17
1.29
1.29
.31
.31
.31
.31
.31
.31
.50
.50
.50
.50
.59
.59
.27
.27
.27
.27
.27
.27
.27
.27
.37
.37
.44
.44
.90
.90
.90
.90
.90
.90
.90
.90
.92
.92
.99
.99
Cat.
No.
These ring terminals are self-insulated with a
PVC insulation sleeve of extra length to give
protection and relieve bending stress at wire’s
flex point. Brazed seam barrel is serrated to
obtain high pull-out value. Terminal is made of
high conductivity electrolytic copper, electro-tin
plated. Insulation material is color-coded:
Color Code
Wire Range
red
22-16
blue
18-14
yellow
12-10
Stock Thickness:
RA & RB = .03
RC
= .04
®
Pkg.
Qty.
50
500
50
500
50
500
50
500
50
500
50
500
Dimensions
U.L. Listed E9809
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT2130A (RC,
RBC)
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.
12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
Telecom 1-800-685-9452
85
Vinyl Terminals
Vinyl Insulated Ring—Expanded Insulation Support
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
18RA-6X
18RA-8X
RA867-170
18RA-10X
RA877-170
18RA-14X
RA727-170
18RA-38X
100
100
1000
100
1000
100
1000
100
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
.170
.170
.170
.170
.170
.170
.170
.170
#6
#8
#8
#10
#10
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
3
3
3
3
3
4
4
4
.97
.97
.97
.97
.97
1.13
1.13
1.24
.31
.31
.31
.31
.31
.50
.50
.54
.27
.27
.27
.27
.27
.37
.37
.35
.81
.81
.81
.81
.81
.88
.88
.91
14RB-4X
14RB-6X
RB857-200
14RB-8X
RB867-200
14RB-10X
RB877-200
14RB-14X
RB717-200
14RB-516X
14RB-38X
100
100
1000
100
1000
100
1000
100
1000
100
100
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
.200
.200
.200
.200
.200
.200
.200
.200
.200
.200
.200
#4
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
3
3
3
3
3
3
3
4
4
4
4
.94
.97
.97
.97
.97
.97
.97
1.14
1.14
1.15
1.16
.25
.31
.31
.31
.31
.31
.31
.50
.50
.50
.54
.27
.27
.27
.27
.27
.27
.27
.38
.38
.38
.35
.81
.81
.81
.81
.81
.81
.81
.89
.89
.89
.91
10RC-6X
RC337-250
10RC-8X
RC777-250
10RC-10X
RC367-250
10RC-14X
RC717-250
10RC-516X
10RC-38X
RC737-250
50
500
50
500
50
500
50
500
50
50
500
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
.250
.250
.250
.250
.250
.250
.250
.250
.250
.250
.250
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
5
5
5
5
5
5
6
6
6
6
6
1.06
1.06
1.06
1.06
1.06
1.06
1.16
1.16
1.17
1.29
1.29
.31
.31
.31
.31
.31
.31
.50
.50
.50
.59
.59
.27
.27
.27
.27
.27
.27
.27
.27
.37
.44
.44
.90
.90
.90
.90
.90
.90
.90
.90
.92
.99
.99
Cat.
No.
Catalog numbers with the suffix X indicate an
expanded insulation support. This means a
wider wire entry to accommodate heavy wall
insulation. Ring terminals won’t fall free even if
the mounting screw loosens.
Stock Thickness:
RA & RB
=
RC
=
.03
.04
®
®
Dimensions
U.L. Listed E9809
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT2130A (RC,
RBC)
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications
(i.e. 12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
86
Telecom 1-800-685-9452
U.L. 94V-0 Rated Ring Terminals
®
Vinyl Insulated Ring
®
Max.
Ins.
Dia.
Wire
Range
A
Series RDV—Aircraft Wire AN
RDV10161
#8
.270
RDV10361
#10
.270
1
RDV10711
⁄
4"
.270
9,8,7
9,8,7
9,8,7
1.40
1.40
1.45
Cat.
No.
Stud
Size
Dimensions
B
C
.41
.41
.45
.24
.24
.27
C
Note: Not available on Mylar Tape.
Stock Thickness: .04
* Brazed Seam, Lolly-Pop Style Tongue
NEW
RD and RE sizes now available with a U.L. 94V-O Vinyl Insulator
Telecom 1-800-685-9452
87
M
1.20
1.20
1.22
Tefzel® Insulated Terminals
®
Tefzel Insulated Ring—Insulation Grip
Cat.
No.
Max.
Ins.
Dia.
Stud
Size
Wire
Range
A
®
Dimensions
B
C
M
Series RAT—For U.L. 94V-O Flamability Rating/High Temperature and Chemical
Resistance.
RAT853
#6
.140
22-18
.81
.25
.25
.69
RAT863
#8
.140
22-18
.84
.31
.25
.69
RAT873
#10
.140
22-18
.84
.31
.25
.69
1
RAT713
⁄
4"
.140
22-18
1.07
.46
.31
.84
Stock Thickness:
RAT & RBT = .03
RCT = .04
Package Quantities:
RAT & RBT = 1000 pcs.
RCT = 500 pcs.
Series RBT
RBT853
RBT863
RBT873
RBT713
#6
#8
#10
1
⁄
4"
.170
.170
.170
.170
16-14
16-14
16-14
16-14
.84
.84
.84
1.08
.31
.31
.31
.46
.25
.25
.25
.31
.69
.69
.69
.81
Series RCT
RCT333
RCT863
RCT363
RCT713
RCT703
RCT733**
#6
#8
#10
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
.210
.210
.210
.210
.210
.210
12-10
12-10
12-10
12-10
12-10
12-10
1.00
1.00
1.00
1.11
1.23
1.29
.37
.37
.37
.52
.52
.58
.27
.27
.27
.32
.31
.35
.81
.81
.81
.85
.96
1.00
** Not available on tape.
U.L. Listed E9809
Installing Tools: ERG2001, WT112M, WT145C.
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.
12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
88
Telecom 1-800-685-9452
Non-Insulated Terminals
®
Non-Insulated Ring
Cat.
No.
These non-insulated ring terminals are made of
electrolytic copper for high conductivity. They
can be installed with crimping tools having a
single indentor or double indentor (recommended for solid wire). Serrated barrel increases grip on wire. Wire range identification is
stamped on the tongue of each terminal.
Most standard bulk catalog numbers can
be put on Mylar Tape for reel fed applications (i.e. 12050 tool and applicaton dies).
Consult tech service.
Please put the suffix M for Mylar Tape
RA2573M.
(Bulk number 1000 and 500 packages.)
Stock Thickness:
A & B = .03
BC = .05
C = .04
Pkg.
Qty.
Wire
Range
®
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
Dimensions
A18-4
A18-6
A85
A18-8
A86
A18-10
A87
A18-14
A71
A72
A73
A18-12
A75
100
100
1000
100
1000
100
1000
100
1000
1000
1000
100
1000
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
#4
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
1
⁄
2"
1
⁄
2"
2
2
2
2
2
2
2
3
3
3
3
3
3
.75
.72
.72
.75
.75
.75
.75
.92
.92
.92
.99
1.06
1.06
.31
.25
.25
.31
.31
.31
.31
.50
.50
.50
.54
.72
.72
.27
.27
.27
.27
.27
.27
.27
.37
.37
.37
.35
.38
.38
.59
.59
.59
.59
.59
.59
.59
.67
.67
.67
.67
.70
.70
B14-4
B132
B14-6
B133
B14-8
B86
B14-10
B87
B14-14
B71
B14-516
B72
B14-38
B73
B14-12
B75
B85
B134
100
1000
100
1000
100
1000
100
1000
100
1000
100
1000
100
1000
100
1000
1000
1000
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
#4
#4
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
1
⁄
2"
#6
#8
2
2
2
2
3
3
3
3
6
6
6
6
6
6
6
6
6
6
.72
.72
.75
.75
.75
.75
.75
.75
.93
.93
.93
.93
.96
.96
1.06
1.06
.75
.72
.25
.25
.31
.31
.31
.31
.31
.31
.50
.50
.50
.50
.54
.54
.72
.72
.31
.25
.27
.27
.27
.27
.27
.27
.27
.27
.38
.38
.38
.38
.35
.35
.38
.38
.27
.27
.59
.59
.59
.59
.59
.59
.59
.59
.68
.68
.68
.68
.68
.68
.70
.70
.59
.59
4
4
4
4
5
5
5
5
6
6
6
6
6
6
.81
.81
.87
.87
.87
.87
.93
.93
1.04
1.04
1.09
1.09
1.32
1.32
.25
.25
.39
.39
.39
.39
.51
.51
.54
.54
.63
.63
.76
.76
.29
.29
.29
.29
.29
.29
.29
.29
.38
.38
.38
.38
.54
.54
.68
.68
.68
.68
.68
.68
.68
.68
.77
.77
.77
.77
.94
.94
4
4
5
5
5
5
7
7
7
8
8
7
7
7
7
7
.82
.82
.82
.82
.85
.85
.82
.91
.91
.98
.98
1.10
1.10
1.10
1.21
1.21
.31
.31
.31
.31
.38
.38
.31
.50
.50
.50
.50
.59
.59
.59
.72
.72
.27
.27
.27
.27
.27
.27
.27
.27
.27
.38
.38
.45
.45
.45
.38
.38
.66
.66
.66
.66
.66
.66
.66
.66
.66
.73
.73
.80
.80
.80
.84
.84
BC14-6
BC85
BC14-8
BC86
BC14-10
BC87
BC14-14
BC71
BC14-516
BC72
BC14-38
BC79
BC14-12
BC75
5 0 heavy duty 16-14 # 6
500
use C tooling # 6
5 0 heavy duty 16-14 # 8
500
use C tooling # 8
5 0 heavy duty 16-14 #10
500use C tooling
#10
5 0 heavy duty 16-14 1⁄
4"
1
500
use C tooling
⁄
4"
5 0 heavy duty 16-14 5⁄
1 6"
500
use C tooling 5⁄
1 6"
5 0 heavy duty 16-14 3⁄
8"
3
500
use C tooling
⁄
8"
5 0 heavy duty 16-14 1⁄
2"
1
500
use C tooling
⁄
2"
C10-6
50
C33
500
C10-8
50
C77
500
C10-10
50
C26
500
C36
1000
C10-14
50
C71
500
C10-516
50
C70
500
C72
1000
C10-38
50
C73
500
C10-12
50
C75
500
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
#6
#6
#8
#8
#10
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
1
⁄
2"
U.L. Listed E9809
Installing tools: WT111M, WT112M, WT110M,
ERG-2002, WT1300, WT2000, WT3155A
Telecom 1-800-685-9452
89
Non-Insulated Terminals
®
Non-Insulated Ring
Pkg.
Qty.
Wire
Range
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
D8-10
D26*
D8-14
D71*
D8-516
D72*
D8-38
D73*
D8-12
D75*
25
200
25
200
25
200
25
200
25
200
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
1
⁄
2"
16
16
14
14
16
16
14
14
14
14
1.13
1.13
1.13
1.13
1.32
1.32
1.32
1.32
1.49
1.49
.48
.48
.48
.48
.59
.59
.59
.59
.82
.82
.36
.36
.36
.36
.49
.49
.49
.49
.55
.55
.90
.90
.90
.90
1.03
1.03
1.03
1.03
1.09
1.09
D10161
D10361
D10711
D10721
D10731
D975*
200
200
200
200
200
200
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
9-8-7
#8
#10
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
1
⁄
2"
12
12
12
12
12
12
1.15
1.15
1.20
1.28
1.28
1.46
.41
.41
.45
.56
.56
.83
.28
.28
.36
.36
.36
.49
.95
.95
.97
1.00
1.00
1.06
E6-10
E26*
E6-14
E71*
E6-516
E72*
E6-38
E73*
E6-12
E75*
20
200
20
200
20
200
20
200
20
200
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
1
⁄
2"
17
17
20
20
20
20
20
20
20
20
1.13
1.13
1.13
1.13
1.32
1.32
1.32
1.32
1.49
1.49
.48
.48
.48
.48
.60
.60
.60
.60
.82
.82
.36
.36
.36
.36
.49
.49
.49
.49
.55
.55
.90
.90
.90
.90
1.03
1.03
1.03
1.03
1.08
1.08
E10261
E10711
E10721
E10731
200
200
200
200
6-5
6-5
6-5
6-5
#10
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
14
14
14
14
1.26
1.26
1.38
1.38
.49
.49
.60
.60
.24
.27
.34
.34
1.02
.99
1.04
1.04
F4-10
F26*
F4-14
F71*
F4-516
F72*
F4-38
F73*
F4-12
F75*
20
200
20
200
20
200
20
200
20
200
4-3
4-3
4-3
4-3
4-3
4-3
4-3
4-3
4-3
4-3
#10
#10
1
⁄
4"
1
⁄
4"
5
⁄
1 6"
5
⁄
1 6"
3
⁄
8"
3
⁄
8"
1
⁄
2"
1
⁄
2"
24
24
25
25
25
25
25
25
25
25
1.16
1.16
1.16
1.16
1.35
1.35
1.35
1.35
1.52
1.52
.48
.48
.48
.48
.60
.60
.60
.60
.82
.82
.36
.36
.36
.36
.49
.49
.49
.49
.55
.55
.93
.93
.93
.93
1.06
1.06
1.06
1.06
1.11
1.11
F10261
F10711
F10721
F10731
F975*
100
100
100
100
200
4-3
4-3
4-3
4-3
4-3
#10
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
1
⁄
2"
20
20
20
20
20
1.37
1.37
1.42
1.42
1.49
.55
.55
.62
.62
.83
.30
.30
.34
.34
.45
1.07
1.07
1.08
1.08
1.10
Cat.
No.
C
These non-insulated ring terminals are made of
electrolytic copper for high conductivity. They
can be installed with crimping tools having a
single indentor or double indentor (recommended for solid wire). Serrated barrel increases grip
on wire. Wire range identification is stamped on
the tongue of each terminal.
Stock Thickness:
D & E = .06
F = .07
D10, E10, F10 = .04
D975 & F975 = .04
* Brazed Seam, Lolly-Pop Style Tongue
®
Dimensions
Installing tools: WT115A D, E, F and G, WT3155A, (D-Series only), TBM6/TBM6S,
WT3175
Installing dies: 11802 INDENTOR (D-E-F-G), D-11803-NEST, E-11805-NEST, F-11806NEST (all ordered separately)
Note: Not available on Mylar Tape.
90
Telecom 1-800-685-9452
Non-Insulated Terminals
®
Non-Insulated Ring
Cat.
No.
These non-insulated ring terminals are made of
electrolytic copper for high conductivity. They
can be installed with crimping tools having a
single indentor or double indentor (recommended for solid wire). Serrated barrel increases grip on wire. Wire range identification is
stamped on the tongue of each terminal.
Stock Thickness:
G & H = .05
J & K = .06
L & M = .07
®
Pkg.
Qty.
Wire
Range
Bolt
Hole
G2-14
G2-516
G2-38
G2-12
10
10
10
10
2-1
2-1
2-1
2-1
1
4
5
16
3
8
1
2
H10-14
J20-38
K30-38
L40-38
M250-38
10
10
5
5
5
1/0
2/0
3/0
4/0
250MCM
1
4
3
8
3
8
3
8
3
8
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
Wt./Lbs.
Per
1000
A
B
C
M
50
50
50
50
1.59
1.59
1.59
1.79
.69
.69
.69
.80
.40
.40
.40
.49
1.26
1.26
1.26
1.36
50
70
82
100
135
1.65
1.84
2.08
2.25
2.40
.77
.83
.93
1.04
1.12
.43
.46
.54
.57
.65
1.32
1.46
1.69
1.77
1.91
40
40
40
40
40
40
1.59
1.59
1.59
1.59
1.79
1.79
.69
.69
.69
.69
.80
.80
.40
.40
.40
.40
.49
.49
1.26
1.26
1.26
1.26
1.36
1.36
Dimensions
G926
G971
G972
G973
G975
G976
100
100
100
100
100
100
1-2
1-2
1-2
1-2
1-2
1-2
H971
H972
H973
H975
H976
100
100
100
100
100
1AN-1/0
1AN-1/0
1AN-1/0
1AN-1/0
1AN-1/0
1
4
5
16
3
8
1
2
5
8
50
50
50
50
50
1.65
1.65
1.65
1.85
1.85
.77
.77
.77
.77
.77
.43
.43
.43
.54
.54
1.32
1.32
1.32
1.41
1.41
J971
J972
J973
J974
J975
J976
100
100
100
100
100
100
1/0AN-2/0
1/0AN-2/0
1/0AN-2/0
1/0AN-2/0
1/0AN-2/0
1/0AN-2/0
1
4
5
16
3
8
7
16
1
2
5
8
60
60
60
60
60
60
1.94
1.94
1.99
1.99
1.99
1.99
.84
.84
.84
.89
.89
.89
.48
.48
.53
.51
.51
.51
1.53
1.53
1.58
1.56
1.56
1.56
K971
K972
K973
K974
K975
K976
100
100
100
100
100
100
2/0AN-3/0
2/0AN-3/0
2/0AN-3/0
2/0AN-3/0
2/0AN-3/0
2/0AN-3/0
1
4
5
16
3
8
7
16
1
2
5
8
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
76
76
76
76
76
76
2.08
2.08
2.08
2.08
2.08
2.08
.93
.93
.93
.93
.93
.93
.54
.54
.54
.54
.54
.54
1.69
1.69
1.69
1.70
1.70
1.70
L973
L974
L975
L976
100
100
100
100
3/0AN-4/0
3/0AN-4/0
3/0AN-4/0
3/0AN-4/0
3
8
⁄"
⁄"
⁄"
⁄"
92
92
92
92
2.25
2.25
2.25
2.25
1.04
1.04
1.04
1.04
.57
.57
.57
.57
1.77
1.77
1.77
1.77
M972
M973
M974
M975
100
100
100
100
4/0AN-250MCM 5⁄
1 6"
4/0AN-250MCM 3⁄
8"
7
4/0AN-250MCM ⁄
1 6"
1
4/0AN-250MCM ⁄
2"
112
112
112
112
2.28
2.40
2.40
2.40
1.12
1.12
1.12
1.12
.62
.65
.65
.65
1.90
1.91
1.91
1.91
#10
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
1
⁄
2"
5
⁄
8"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
⁄"
7
16
1
2
5
8
AN—Aircraft Wire
Installing tools: TBM6/TBM6S, WT3175 (G, H, J Series only)
Note: Not available on Mylar Tape.
Telecom 1-800-685-9452
91
Flag Terminals
®
Non-Insulated Flag
®
Wire
Range
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
AB14-6A
100
AB51
1000
AB14-8A
100
AB52
1000
AB14-10A 100
AB53
1000
22-14
22-14
22-14
22-14
22-14
22-14
#6
#6
#8
#8
#10
#10
2 1⁄
2
2 1⁄
2
1
2⁄
2
1
2⁄
2
1
2⁄
2
1
2⁄
2
.55
.55
.55
.55
.55
.55
.31
.31
.31
.31
.31
.31
.22
.22
.22
.22
.22
.22
.39
.39
.39
.39
.39
.39
C51
C10-8A
C52
C10-10A
C53
500
50
500
50
500
12-10
12-10
12-10
12-10
12-10
#6
#8
#8
#10
#10
5
5
5
5
5
.66
.66
.66
.66
.66
.31
.31
.31
.31
.31
.25
.25
.25
.25
.25
.48
.48
.48
.48
.48
Flag terminals allow a 90° connection to the
terminal block without bending the wire.
D236
D226
D271
200
200
200
9,8,7
9,8,7
9,8,7
#10
#10
1
⁄
4"
—
—
—
.83
.88
.92
.50
.50
.50
.25
.29
.33
.59
.64
.68
Stock Thickness:
AB = .03
C = .04
D = .06
E = .06
F = .07
G = .08
E226
E271
E272
200
200
200
6,5
6,5
6,5
#10
1
⁄
4"
5
⁄
1 6"
—
—
—
.93
.97
1.05
.50
.50
.50
.29
.33
.41
.69
.73
.81
F226
F271
F272
F273
200
200
200
200
4,3
4,3
4,3
4,3
#10
1
⁄
4"
5
⁄
1 6"
3
⁄
8"
—
—
—
—
1.07
1.10
1.18
1.20
.56
.63
.63
.63
.33
.33
.41
.43
.80
.80
.88
.90
G671
G672
G673
100
100
100
2
2
2
—
—
—
1.20
1.28
1.32
.63
.63
.63
.33
.41
.46
.89
.97
1.02
Cat.
No.
Pkg.
Qty.
1
4
5
16
3
8
⁄"
⁄"
⁄"
Dimensions
U.L. Listed E9809
Installing tools: WT119, ERG-2004, WT129 = D, E, F, G
Note: Not available on Mylar Tape.
92
Telecom 1-800-685-9452
Fork Terminals
®
Nylon Insulated Fork—Insulation Grip
Cat.
No.
Fork terminals with nylon insulation sleeves,
recommended for temperatures up to 105°C.
Inner bronze insulation grip sleeve lengthens
flex radius of conductor and eliminates conductor creep. Nylon jacket is color-coded.
Stock thickness same as ring terminal of same
size.
®
Wt./Lbs.
Per
1000
A
B
C
M
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
3
3
3
3
3
3
4
4
.83
.83
.86
.86
.86
.86
.95
.95
.25
.25
.31
.31
.31
.31
.44
.44
.25
.25
.25
.25
.25
.25
.31
.31
.71
.71
.71
.71
.71
.71
.70
.70
.162
.162
.162
.162
.162
.162
.162
.162
.162
.190
.190
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
#6
#8
#10
3 1⁄
2
3 1⁄
2
3 1⁄
2
3 1⁄
2
4
4
4
4
6
6
6
.87
.87
.87
.87
.87
.87
.95
.95
.74
.95
.95
.31
.31
.31
.31
.38
.38
.44
.44
.28
.31
.31
.25
.25
.25
.25
.25
.25
.28
.28
.16
.25
.25
.71
.71
.71
.71
.71
.71
.74
.74
.60
.79
.79
.210
.210
.210
.210
.210
.210
.210
.210
.250
.250
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
#8
#10
6
6
6
6
6
6
6
6
6
6
.97
.97
1.00
1.00
1.00
1.00
1.12
1.12
1.10
1.10
.31
.31
.37
.37
.37
.37
.50
.50
.37
.37
.27
.27
.27
.27
.27
.27
.27
.27
.27
.27
.81
.81
.81
.81
.81
.81
.86
.86
.91
.91
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
RA18-6F
RA1103
RA18-8F
RA1123
RA18-10F
RA1153
RA18-14F
RA1163
100
1000
100
1000
100
1000
100
1000
22-16
22-16
22-16
22-16
22-16
22-16
22-16
22-16
.136
.136
.136
.136
.136
.136
.136
.136
RB14-6F
RB1113
RB14-8F
RB1123
RB14-10F
RB1153
RB14-14F
RB1163
RB1103
RB1124
RB1154
100
1000
100
1000
100
1000
100
1000
1000
1000
1000
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
RC10-6F
50
RC1113
500
RC10-8F
50
RC1123
500
RC10-10F
50
RC1153
500
RC10-14F
50
RC1163
500
RC1124
1000
RC1154
1000
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
Dimensions
U.L. Listed E9809
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT145A,
WT2130A (RC)
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications
(i.e. 12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
Telecom 1-800-685-9452
93
Fork Terminals
®
®
Nylon Insulated Fork Flanged Tongue—Insulation Grip
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
RA18-6FS 100
RA1203
1000
RA18-8FS 100
RA1223
1000
RA18-10FS 100
RA1253
1000
22-16
22-16
22-16
22-16
22-16
22-16
.136
.136
.136
.136
.136
.136
#6
#6
#8
#8
#10
#10
3
3
3
3
3
3
.75
.75
.89
.89
.93
.93
.28
.28
.31
.31
.38
.38
.16
.16
.23
.23
.26
.26
.62
.62
.65
.65
.68
.68
RB14-6FS 100
RB1203
1000
RB14-8FS 100
RB1223
1000
RB14-10FS 100
RB1253
1000
18-14
18-14
18-14
18-14
18-14
18-14
.162
.162
.162
.162
.162
.162
#6
#6
#8
#8
#10
#10
4
4
4
4
4
4
.74
.74
.89
.89
.94
.94
.28
.28
.31
.31
.38
.38
.16
.16
.23
.23
.27
.27
.60
.60
.66
.66
.69
.69
RC10-8FS
50
RC1223
500
RC10-10FS
50
RC1253
500
RC1254
1000
12-10
12-10
12-10
12-10
12-10
.210
.210
.210
.210
.250
#8
#8
#10
#10
#10
5
5
5
5
5
.97
.97
1.00
1.00
1.12
.34
.34
.38
.38
.38
.23
.23
.26
.26
.26
.73
.73
.74
.74
.86
Cat.
No.
C
B
M
A
Fork terminals allow easy installation because
screw needs only to be loosened. Suffix S indicates a flanged-tongue fork with turned up tips
for extra holding protection.
Stock thickness same as ring terminal of same
size.
Dimensions
U.L. Listed E9809
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT145A,
WT2130A (RC)
turned up toes
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.
12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
94
Telecom 1-800-685-9452
Fork Terminals
®
Vinyl Insulated Fork—Insulation Support
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
18RA-6F
RA1167
18RA-8F
RA1147
18RA-10F
RA1157
100
1000
100
1000
100
1000
22-16
22-16
22-16
22-16
22-16
22-16
.150
.150
.150
.150
.150
.150
#6
#6
#8
#8
#10
#10
5
5
5
5
5
5
.94
.94
.97
.97
.97
.97
.25
.25
.31
.31
.31
.31
.27
.27
.27
.27
.27
.27
.81
.81
.81
.81
.81
.81
14RB-6F
RB647
14RB-6FS†
14RB-8F
RB657
14RB-10F
RB1157
14RB-14F
RB1717
100
1000
100
100
1000
100
1000
100
1000
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
.170
.170
.170
.170
.170
.170
.170
.170
.170
#6
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
6
6
6
6
6
6
6
6
6
.97
.97
.89
.97
.97
.97
.97
1.11
1.11
.31
.31
.30
.31
.31
.31
.31
.44
.44
.27
.27
.25
.27
.27
.27
.27
.38
.38
.81
.81
.75
.81
.81
.81
.81
.89
.89
50
500
50
500
50
500
50
500
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
.210
.210
.210
.210
.210
.210
.210
.210
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
7
7
7
7
7
7
7
7
1.09
1.09
1.09
1.09
1.09
1.09
1.15
1.15
.38
.38
.38
.38
.38
.38
.50
.50
.27
.27
.27
.27
.27
.27
.37
.37
.90
.90
.90
.90
.90
.90
.90
.90
Cat.
No.
These fork terminals have extra-long PVC insulation sleeve for protection and stress relief at
wire’s flex point. Brazed seam barrel is serrated
for high pull-out value. Terminal is high conductivity electrolytic copper, electro-tin plated.
Insulation is color-coded.
Stock thickness same as ring terminal of same
size.
®
10RC-6F
RC1337
10RC-8F
RC1147
10RC-10F
RC1157
10RC-14F
RC1167
Dimensions
U.L. Listed E9809
Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT2130A (RC)
†
Turned-up toes
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.
12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
Telecom 1-800-685-9452
95
Fork Terminals
®
Vinyl Insulation Fork—Expanded Insulation Support
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
18RA-6FX
100
RA1167-170 1000
18RA-8FX
100
RA1147-170 1000
18RA-10FX
100
RA1157-170 1000
22-16
22-16
22-16
22-16
22-16
22-16
.170
.170
.170
.170
.170
.170
#6
#6
#8
#8
#10
#10
5
5
5
5
5
5
.94
.94
.97
.97
.97
.97
.25
.25
.31
.31
.31
.31
.27
.27
.27
.27
.27
.27
.81
.81
.81
.81
.81
.81
14RB-6FX
100
RB647-200 1000
14RB-8FX
100
RB657-200 1000
14RB-10FX
100
RB1157-200 1000
18-14
18-14
18-14
18-14
18-14
18-14
.200
.200
.200
.200
.200
.200
#6
#6
#8
#8
#10
#10
6
6
6
6
6
6
.97
.97
.97
.97
.97
.97
.31
.31
.31
.31
.31
.31
.27
.27
.27
.27
.27
.27
.81
.81
.81
.81
.81
.81
10RC-8FX
RC1147-250
10RC-10FX
RC1157-250
10RC-14FX
12-10
12-10
12-10
12-10
12-10
.250
.250
.250
.250
.250
#8
#8
#10
#10
1
⁄
4"
7
7
7
7
7
1.09
1.09
1.09
1.09
1.15
.38
.38
.38
.38
.50
.27
.27
.27
.27
.37
.90
.90
.90
.90
.90
Cat.
No.
Fork terminals allow easy installation since the
mounting screw does not have to be completely
removed. Catalog numbers with the suffix X
indicate an expanded insulation support. This
means a wider wire entry to accommodate
heavy wall insulation.
Stock thickness same as ring terminal of same
size.
®
50
500
50
500
50
Dimensions
U.L. Listed E9809
Installing tools: WT145C, WT2000, WT112M, ERG2001, ERG2003, WT2130A (RC)
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.
12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
96
Telecom 1-800-685-9452
Fork Terminals
®
Non-Insulated Fork
Cat.
No.
These non-insulated fork terminals are made of
electrolytic copper for high conductivity. They
can be installed with crimping tools having a
single indentor or double indentor (recommended for solid wire). Serrated barrel
increase grip on wire. Wire range identification
is stamped on the tongue of each terminal.
Catalog numbers with the suffix S indicate a
flanged-tongue fork with turned-up tips for
extra holding protection in the event the mounting screw loosens.
Stock thickness same as ring terminal of same
turned up toes
size.
Pkg.
Qty.
®
Wire
Range
Bolt
Hole
Wt./Lbs.
Per
1000
A
Dimensions
B
C
M
A18-6F
A116
A18-8F
A114
A18-10F
A115
100
1000
100
1000
100
1000
22-16
22-16
22-16
22-16
22-16
22-16
#6
#6
#8
#8
#10
#10
4
4
4
4
4
4
.72
.72
.75
.75
.75
.75
.25
.25
.31
.31
.31
.31
.27
.27
.27
.27
.27
.27
.59
.59
.59
.59
.59
.59
B14-6F
B64
B19†
B14-8F
B65
B14-10F
B115
B14-14F
100
1000
1000
100
1000
100
1000
100
18-14
18-14
18-14
18-14
18-14
18-14
18-14
18-14
#6
#6
#6
#8
#8
#10
#10
1
⁄
4"
6
6
6
6
6
6
6
6
.75
.75
.66
.75
.75
.75
.75
.90
.31
.31
.25
.31
.31
.31
.31
.44
.27
.27
.13
.27
.27
.27
.27
.38
.59
.59
.50
.59
.59
.59
.59
.68
C10-6F
C133
C10-8F
C114
C10-10F
C115
C10-14F
C116
50
500
50
500
50
500
50
50
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
#6
#6
#10
#10
#10
#10
1
⁄
4"
1
⁄
4"
7
7
7
7
7
7
7
7
.77
.77
.82
.82
.82
.82
.98
1.15
.31
.31
.38
.38
.38
.38
.50
.50
.27
.27
.27
.27
.27
.27
.37
.37
.63
.63
.63
.63
.63
.63
.73
.90
U.L. Listed E9809
Installing tools: WT111C, WT112M, WT110M, WT2000, ERG2002, ERG2003, WT1300,
WT3155A
†
Turned-up toes
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.
12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
Telecom 1-800-685-9452
97
Locking Fork Terminals
Locking fork terminals have a specially designed tongue that lets
them go on like a fork and stay on
like a ring.
®
Nylon Insulated Locking Fork—Insulation Grip
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
RA18-6FL
RA2213
RA18-8FL
RA2243
RA18-10FL
RA2253
100
1000
100
1000
100
1000
22-16
22-16
22-16
22-16
22-16
22-16
.136
.136
.136
.136
.136
.136
#6
#6
#8
#8
#10
#10
5
5
5
5
5
5
.86
.86
.86
.86
.86
.86
.25
.25
.29
.29
.29
.29
.25
.25
.25
.25
.25
.25
.71
.71
.71
.71
.71
.71
RB14-6FL
RB2213
RB2214
RB14-8FL
RB2233
RB14-10FL
RB2253
RB2254
100
1000
1000
100
1000
100
1000
1000
18-14
18-14
18-14
18-14
18-14
18-14
18-14
.162
.162
.190
.162
.162
.162
.162
.190
#6
#6
#6
#8
#8
#10
#10
#10
6
6
6
6
6
6
6
6
.87
.87
.95
.87
.87
.87
.87
.95
.25
.25
.25
.29
.29
.29
.29
.29
.25
.25
.25
.25
.25
.25
.25
.25
.71
.71
.79
.71
.71
.71
.71
.71
RC10-6FL
RC2203
RC2204
RC10-8FL
RC2213
RC10-10FL
RC2223
RC2224
RC10-14FL
RC2233
50
500
1000
50
500
50
500
1000
50
500
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
.210
.210
.250
.210
.210
.210
.210
.250
.210
.210
#6
#6
#6
#8
#8
#10
#10
#10
1
⁄
4"
1
⁄
4"
8
8
8
8
8
8
8
.97
.97
1.07
1.00
1.00
1.00
1.00
1.10
1.12
1.12
.31
.31
.31
.37
.37
.37
.37
.37
.50
.50
.27
.27
.27
.27
.27
.27
.27
.27
.32
.32
.81
.81
.91
.81
.81
.81
.81
.91
.86
.86
Cat.
No.
Stock thickness same as ring terminal of same
size.
®
8
8
Dimensions
U.L. Listed E9809
U.S. Pat. 3,590,387
Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M, WT145A,
WT2130A (RC)
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.
12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
98
Telecom 1-800-685-9452
Locking Fork Terminals
®
Vinyl Insulated Locking Fork—Insulation Support
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
18RA-6FL
RA2217
RA2227
18RA-8FL
RA2247
18RA-10FL
RA2257
100
1000
1000
100
1000
100
1000
22-16
22-16
22-16
22-16
22-16
22-16
22-16
.150
.150
.155
.150
.150
.150
.150
#6
#6
#6
#8
#8
#10
#10
5
5
5
5
5
5
5
.97
.97
.97
.97
.97
.97
.97
.25
.25
.29
.29
.29
.29
.29
.25
.25
—
.25
.25
.25
.25
.81
.81
.81
.81
.81
.81
.81
14RB-6FL
RB2207
RB2217
14RB-8FL
RB2237
14RB-10FL
RB2257
100
1000
1000
100
1000
100
1000
18-14
18-14
18-14
18-14
18-14
18-14
18-14
.170
.170
.170
.170
.170
.170
.170
#6
#6
#6
#8
#8
#10
#10
6
6
6
6
6
6
6
.97
.97
.97
.97
.97
.97
.97
.25
.25
.29
.29
.29
.29
.29
.27
.27
.27
.27
.27
.27
.27
.81
.81
.81
.81
.81
.81
.81
10RC-6FL
RC2207
10RC-8FL
RC2217
10RC-10FL
RC2227
10RC-14FL
RC2237
50
500
50
500
50
500
50
500
12-10
12-10
12-10
12-10
12-10
12-10
12-10
12-10
.220
.220
.220
.220
.220
.220
.220
.220
#6
#6
#8
#8
#10
#10
1
⁄
4"
1
⁄
4"
8
8
8
8
8
8
8
8
1.09
1.09
1.09
1.09
1.09
1.09
1.09
1.09
.31
.31
.37
.37
.37
.37
.49
.49
.27
.27
.27
.27
.27
.27
.27
.27
.90
.90
.90
.90
.90
.90
.90
.90
Cat.
No.
Stock thickness same as ring terminal of same
size.
®
Dimensions
U.L. Listed E9809
U.S. Pat. 3,590,387
Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.
12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
Telecom 1-800-685-9452
99
Locking Fork Terminals
®
®
Vinyl Insulated Locking Fork—Expanded Insulation Support
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
M
18RA-6FLX
100
18RA-8FLX
100
18RA-10FLX 100
RA2257-170 1000
22-16
22-16
22-16
22-16
.170
.170
.170
.170
#6
#8
#10
#10
5
5
5
5
.97
.97
.97
.97
.25
.29
.29
.29
.25
.25
.25
.25
.81
.81
.81
.81
14RB-6FLX
RB2207-200
RB2217-200
14RB-8FLX
RB2237-200
14RB-10FLX
RB2257-200
100
1000
1000
100
1000
100
1000
18-14
18-14
18-14
18-14
18-14
18-14
18-14
.200
.200
.200
.200
.200
.200
.200
#6
#6
#6
#8
#8
#10
#10
6
6
6
6
6
6
6
.97
.97
.97
.97
.97
.97
.97
.31
.31
.29
.31
.31
.31
.31
.27
.27
.27
.27
.27
.27
.27
.81
.81
.81
.81
.81
.81
.81
10RC-6FLX
RC2207-250
10RC-8FLX
10RC-10FLX
RC2227-250
10RC-14FLX
50
500
50
50
500
50
12-10
12-10
12-10
12-10
12-10
12-10
.250
.250
.250
.250
.250
.250
#6
#6
#8
#10
#10
1
⁄
4"
8
8
8
8
8
8
1.07
1.07
1.10
1.10
1.10
1.22
.31
.31
.37
.37
.37
.50
.27
.27
.27
.27
.27
.32
.91
.91
.91
.91
.91
.96
Cat.
No.
Stock thickness same as ring terminal of same
size.
Dimensions
U.L. Listed E9809
U.S. Pat. 3,590,387
Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e.
12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
Heat Shrinkable Locking Fork Terminals—
Expanded Insulation Support
Cat.
No.
Pkg.
Qty.
®
®
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
Dimensions
A
B
RAS18-6FLX
RAS18-8FLX
RAS18-10FLX
100
100
100
22-18
22-18
22-18
.170
.170
.170
#6
#8
#10
5
5
5
1.350
1.350
1.350
.25
.29
.29
RBS14-6FLX
RBS14-8FLX
RBS14-10FLX
100
100
100
16-14
16-14
16-14
.200
.200
.200
#6
#8
#10
6
6
6
1.350
1.350
1.350
.25
.29
.29
RCS10-6FLX
RCS10-8FLX
RCS10-10FLX
RCS10-14FLX
50
50
50
50
12-10
12-10
12-10
12-10
.250
.250
.250
.250
#6
#8
#10
1
⁄
4"
8
8
8
8
1.350
1.350
1.350
1.350
.31
.37
.37
.49
U.L. Listed E9809
Installing tool: WT1255
Note: Heat Shrinkable terminals not available on Mylar Tape.
100
Telecom 1-800-685-9452
Locking Fork Terminals
®
Non-Insulated Locking Fork
Pkg.
Qty.
Wire
Range
Bolt
Hole
Wt./Lbs.
Per
1000
A
B
C
A18-6FL
A221
A18-8FL
A224
A18-10FL
A225
100
1000
100
1000
100
1000
22-16
22-16
22-16
22-16
22-16
22-16
#6
#6
#8
#8
#10
#10
4 3⁄
4
4 3⁄
4
3
4⁄
4
3
4⁄
4
3
4⁄
4
3
4⁄
4
.75
.75
.75
.75
.75
.75
.25
.25
.29
.29
.29
.29
.27
.27
.27
.27
.27
.27
.59
.59
.59
.59
.59
.59
B14-6FL
B220
B14-8FL
B223
B14-10FL
B225
100
1000
100
1000
100
1000
18-14
18-14
18-14
18-14
18-14
18-14
#6
#6
#8
#8
#10
#10
4 3⁄
4
4 3⁄
4
3
4⁄
4
3
4⁄
4
3
4⁄
4
3
4⁄
4
.75
.75
.75
.75
.75
.75
.25
.25
.29
.29
.29
.29
.27
.27
.27
.27
.27
.27
.59
.59
.59
.59
.59
.59
C10-6FL
C220
C10-8FL
C221
C10-10FL
C222-TB
C10-14FL
50
500
50
500
50
500
50
12-10
12-10
12-10
12-10
12-10
12-10
12-10
#6
#6
#8
#8
#10
#10
1
⁄
4"
7 3⁄
4
7 3⁄
4
3
7⁄
4
3
7⁄
4
3
7⁄
4
3
7⁄
4
3
7⁄
4
.85
.85
.85
.85
.85
.85
.85
.31
.31
.37
.37
.37
.37
.49
.27
.27
.27
.27
.27
.27
.27
.66
.66
.66
.66
.66
.66
.66
Cat.
No.
Stock thickness same as ring terminal of same
size.
®
Dimensions
M
U.L. Listed E9809
U.S. Pat. 3,590,387
Installing tools: WT110M, WT111M, WT112M, WT2000, ERG-2002, WT1300,
WT3155A (B&C)
Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications
(i.e. 12050 tool and application dies).
Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.)
Telecom 1-800-685-9452
101
Heat Shrinkable Terminal, Splices, Disconnects
Heat Shrinkable
These ring terminals, butt splices
and disconnects are self-insulated
with heat shrinkable nylon and
internally coated sealant. Upon
completed installation, a fully
sealed connection is achieved to
protect the joint against the
degrading effects of galvanic
action, corrosion, and environmen®
®
Heat Shrinkable-Ring Terminals—Expanded Insulation Support
Cat.
No.
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
RAS18-6X
RAS18-8X
RAS18-10X
100
100
100
22-18
22-18
22-18
.170
.170
.170
#6
#8
#10
2
3
2
RBS14-6X
RBS14-8X
RBS14-10X
100
100
100
16-14
16-14
16-14
.200
.200
.200
#6
#8
#10
3
3
3
RCS10-6X
RCS10-8X
RCS10-10X
RCS10-14X
50
50
50
50
12-10
12-10
12-10
12-10
.250
.250
.250
.250
#6
#8
#10
1
4"
⁄
3
5
5
6
Installing tool: WT1255
See previous pages for dimensional information.
Heat Shrinkable-Locking Fork Terminals—
Expanded Insulation Support
®
®
Cat.
No.
Pkg.
Qty.
Wire
Range
Max.
Ins.
Bolt
Hole
Wt./Lbs.
Per
1000
RAS18-6FLX
RAS18-8FLX
RAS18-10FLX
100
100
100
22-18
22-18
22-18
.170
.170
.170
#6
#8
#10
5
5
5
RBS14-6FLX
RBS14-8FLX
RBS14-10FLX
100
100
100
16-14
16-14
16-14
.200
.200
.200
#6
#8
#10
6
6
6
RCS10-6FLX
RCS10-8FLX
RCS10-10FLX
RCS10-14FLX
50
50
50
50
12-10
12-10
12-10
12-10
.250
.250
.250
.250
#6
#8
#10
1
⁄
4"
8
8
8
8
Installing tool: WT1255
Note: Not available on Mylar Tape.
102
Telecom 1-800-685-9452