Terminals Why Sta-Kon Terminals Are Better Like any other value added manufacturing process, using the best material is only a start. Our StaKon terminals are all manufactured with the customer in mind, not a price tag! The following product features are usually absent in competitive products. Chamfered/Funneled Terminal Barrel Entry This feature makes wire insertion faster and easier. Chamfering eliminates wire strand “hang up” and departure upon insertion into the terminal’s barrel. The loss of even a couple of wire strands can have negative results on electrical efficiency and resistance to mechanical strain. Sta-Kon’s Long Barrel Design If lowering electrical resistance, preventing wire pullout, eliminating a “missed” crimp and an insulator that stays on the barrel during installation are your goals, then, you must design a terminal with a long barrel. The fact is that most competitive barrel lengths range from 20%-50% shorter than the Sta-Kon. The results are usually a stream of electrical failure, rework and added expense. This also provides the insulator with additional surface area, holding tight to the barrel. Many competitive insulators come off during crimping due to a limited barrel length. able on most 1-piece Sta-Kon terminals: Platings/Finish Deep Internal Serrations After the insertion of a wire into the terminal’s barrel, a deep serrated interior insures a large area of contact which lowers the resistance of a connection. Upon the mechanical force of tool applied pressure, the wire strands cold flow into the serrated interior. This guarantees electrical resistance lower than the wire to which it is applied. This feature also prevents pullout from vibration and mechanical strain. Deep internal serrations can be compared to the effective holding power of a well treaded tire on a wet highway. Electroplated-Tin is standard. All others require minimum order quantities and are generally not stocked. Alternative platings as follows: Gold, Silver, Tin-alloys, Finish Suffix Spec. Gold Plate GP Nickel Plate Plain Finish Silver Plate Tin Plate NP PF SP TP MIL-G-45204 Type II, Grade B, C, D, Class O QQ-N-290 Class 2, Grade G None MIL-T-16366 Type I or II, 400°F, 204°C MIL-T-10727 Type I To order add the indicated suffix to the regular catalog number. Nickel, etc. The following finishes are avail- Telecom 1-800-685-9452 75 Terminals Why Sta-Kon Terminals Are Better—continued Anti-Rotational Tongues er electrical flow, void free. This is a unique feature to the Thomas & Betts ring tongue terminal. This design prevents terminal shorting by keeping the terminal secure in the terminal block. The installer can place a greater number of terminals, closer together without worry. Selective Annealing Because of the mechanical strength of copper, an installer can experience fatigue associated with repeated installations. For this reason Thomas & Betts puts our terminals through one more step called selective annealing. This process leaves the barrel soft enough to crimp and form around the wire. However, we “cold form” the tongue during the manufacturing process so it remains strong. This is done so the tongue can withstand repeated bends and bolt tightening strain common in most electrical installations. Many competitors attempt to accomplish similar goals by removing valuable material or using a softer copper which has lower conductivity. This increases electrical resistance as well as the odds for shorting and downtime. Brazed or Overlapped Seam A long barrel design is of little value unless it is one solid piece. That is why Thomas & Betts brazes the seam on our vinyl insulated Sta-Kon and overlaps the seam on nylon insulated terminals. Many competitive terminals have butted seams. This means increased chances for wirestrand loss, poor resistance, wire pullout and electrical failure. If the installer doesn’t position the tool exactly on the correct spot on the barrel, there’s likely going to be an improper termination. The butted seam can also fold due to tool-applied pressure piercing the terminals insulation from the inside out. With a brazed or overlapped seam the installer can crimp anywhere along the barrel’s surface providing up to 21⁄2 times the tensile strength of a butted seam terminal, guaranteeing prop- 76 Telecom 1-800-685-9452 Terminals Thomas & Betts developed the first tool-applied solderless terminals and connectors nearly 50 years ago in response to industry awareness of the need for better performance of electrical systems. Today, sophisticated electrical and electronic equipment requires an even higher degree of reliability. Here are key factors built into the Sta-Kon terminal and connector line that deliver this reliability: • Broad product selection • Job suited tooling • Testing and approvals • Field proven performance • New product development • Service and availability Sta-Kon® Technical Data center reinforced spring detent for minimum insertion force Terminals & Splices Insulation Rating flat bottom box funneled wire entrance extra-length insulation sleeve brazed seam Nylon Vinyl TEFZEL* **1000V fixture or sign Disconnects U.L. 94 Flammability Voltage Temperature V-2 V-0 V-0 600V** 600V** 600V** 1 0 5°C 1 0 5°C 1 5 0°C 300V 1 0 5°C electro tin plate complete identification compound spring rails provide positive contact after repeated insertions & crimp produces even compression forces on insulation and stranding Sta-Kon® Disconnects • Internal barrel serrations and long barrel provide for maximum tensile strength • Complete line of installing tools, engineered to match tool with terminal • Funnel entry insulators allow for easier inserting of wire into barrel • Color-coded for easy installation selectively annealed long barrel color-coded TEFZEL*, Nylon, or Vinyl complete wire & stud size identification anti-rotational tongue vinyl brazed seam, or NYLON/TEFZEL* insulated grip sleeve strands enter as a homogeneous group and compact tightly under compression due to fully brazed seam serrated inner barrel for maximum contact & tensile strength hardened tongue Sta-Kon® Ring, fork & locking fork • Complete line of installing tools engineered to match tool with terminal • First to gain military approval for pressure connections … many styles available for military applications • Sta-Kon products exceed test specification requirements of military, U.L. and CSA • TEFZEL* & Nylon Terminals provided with extra metal sleeve to grip insulation • Vinyl insulated and bare Sta-Kons feature brazed seam wire barrels which can be crimped at any place on the barrel circumference The Shure Stake® tools are matched to terminals ERG-2001 Telecom 1-800-685-9452 The Shure Stake mechanism prevents the dies from releasing the terminal until the proper compression has been completed. With this method, an operator achieves a reliable crimp everytime. 77 Terminals Performance Data CODE Typical test value of T&B Terminals 30 28 The proper installation of terminals, splices and connectors is very important to the efficient performance of an electrical system. The properly installed connector will allow good conductivity through the termination. A poor termination results in a high resistance connection. A poor connector installation may cause damage or failure of an entire system. Certain basic requirements must be met to make a good termination. 1. Before the connector or terminal is installed on the conductor, follow these recommended practices: • Strip the insulation carefully so as to avoid nicking or cutting conductor strands • Strip the insulation to the proper length so that the conductors can be inserted fully into the connector barrel; the wire/cable should be visible in the inspection hole of the lug; the proper strip length can be found on page 49D. 2. Thomas & Betts wire strippers will help eliminate these problems stripping by length NEMA requirement 24 Voltage Drop (mv) The Proper Installation Procedure for the Quality Assured Connection 20 16 12 8 4 0 8 22 16 20 18 24 16 32 14 40 12 48 10 AMPS AWG Voltage Drop Test 500 Cycles Thomas & Betts terminals show consistently lower millivolt drops than those allowed by NEMA specification. CODE Typical test value of T&B Terminals 120 100 NEMA requirement Wire Pullout Force (lbs.) 80 60 stripped wire 40 rest 20 18 16 14 Wire Size (AWG) 12 properly gaging terminal and meaorient tongue as shown suring the depth and length requirements for the conductor. See page 44D for wire strippers. 0 22 indentor 10 Wire Pullout Tension Test Thomas & Betts terminals show consistently higher wire retention forces than those required by NEMA specification. 78 Telecom 1-800-685-9452 Terminals The Sta-Kon® Terminal Numbering System Distributor Package 100/50 Bulk “O.E.M.” Packaged 1000/500 Common to Both Packages • Letter A denotes 22-18 AWG wire range • Letter B denotes 16-14 AWG wire range • Letter C denotes 12-10 AWG wire range • Letter R preceding the above letters indicates the terminal is insulated • No letter R… no insulation … no exception! Distributor Packaged Part numbers are very descriptive indicating insulation and type, stud size, tongue style and the largest maximum wire that can be put inside. • If the letter R precedes the number the part is nylon insulated—RA18-6 • If the letter R follows the number the part is vinyl insulated—14RB-8 stripping length stripped wire indentor terminal rest Telecom 1-800-685-9452 orient tongue as shown 79 Installation Procedure 1. Twist the wires to eliminate fanning of strands. 2. Open tool handles fully. 3. Insert terminal in proper die nest and locate it as shown above. When crimping a butt splice, position in proper die nest with window facing indentor. 4. Close handles slightly to secure terminal. Do not deform terminal. 5. Insert properly stripped wire into terminal. 6. Complete crimp by closing handles. Nylon Terminals ® Nylon Insulated Ring—Insulation Grip Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M 100 100 100 100 100 26-22 26-22 26-22 26-22 26-22 .083 .083 .083 .083 .083 #2 #4 #6 #8 #10 1 1 1 1 1 .57 .65 .65 .75 .75 .14 .21 .21 .25 .25 .13 .20 .20 .23 .23 .49 .54 .54 .62 .62 RAX23* RAX43* RAX63* RAX83* RAX103* 1000 1000 1000 1000 1000 26-24 26-24 26-24 26-24 26-24 .125 .125 .125 .125 .125 #2 #4 #6 #8 #10 3 3 3 3 3 .66 .74 .84 .84 .84 .14 .20 .25 .25 .25 .14 .19 .22 .22 .24 .59 .64 .72 .72 .72 RA18-4 RA323 RA333 RA18-6 RA853 RA18-8 RA833 RA863 RA18-10 RA873 RA18-14 RA713 RA18-516 RA723 RA18-38 RA733 RA18-12 RA753 100 1000 1000 100 1000 100 1000 1000 100 1000 100 1000 100 1000 100 1000 100 1000 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 .136 .136 .136 .136 .136 .136 .136 .136 .136 .136 .136 .136 .136 .136 .136 .136 .136 .136 #4 #4 #6 #6 #6 #8 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" 2 2 2 2 2 3 3 3 2 2 3 3 3 3 3 3 3 3 .70 .70 .70 .83 .83 .83 .83 .83 .86 .86 1.07 1.07 1.07 1.07 1.17 1.17 1.27 1.27 .23 .23 .23 .26 .26 .26 .26 .26 .31 .31 .46 .46 .46 .46 .53 .53 .72 .72 .14 .14 .14 .25 .25 .25 .25 .25 .25 .25 .31 .31 .31 .31 .35 .35 .50 .50 .59 .59 .59 .71 .71 .71 .71 .71 .71 .71 .84 .84 .84 .84 .87 .87 .92 .92 RB14-4 RB1323 RB14-6 RB853 RB1333 RB14-8 RB863 RB14-10 RB873 RB14-14 RB713 RB14-516 RB723 RB14-38 RB733 RB14-12 RB753 100 1000 100 1000 1000 100 1000 100 1000 100 1000 100 1000 100 1000 100 1000 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 .162 .162 .162 .162 .162 .162 .162 .162 .162 .162 .162 .162 .162 .162 .162 .162 .162 #4 #4 #6 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" 2 1⁄ 2 2 1⁄ 2 3 3 3 3 3 3 1⁄ 2 3 1⁄ 2 1 3⁄ 2 1 3⁄ 2 1 3⁄ 2 1 3⁄ 2 1 3⁄ 2 1 3⁄ 2 4 4 .72 .72 .89 .89 .74 .89 .89 .89 .89 1.08 1.08 1.08 1.08 1.17 1.17 1.25 1.25 .26 .26 .31 .31 .26 .31 .31 .31 .31 .47 .47 .47 .47 .53 .53 .72 .72 .14 .14 .25 .25 .14 .25 .25 .25 .25 .31 .31 .31 .31 .35 .35 .50 .50 .59 .59 .71 .71 .59 .71 .71 .71 .71 .81 .81 .84 .84 .87 .87 .90 .90 RC10-6 RC333 RC10-8 RC863 RC10-10 RC363 RC10-14 RC713 RC10-516 RC703 RC10-38 RC733 RC10-12 RC753 50 500 50 500 50 500 50 500 50 500 50 500 50 500 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 .210 .210 .210 .210 .210 .210 .210 .210 .210 .210 .210 .210 .210 .210 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" 3 3 5 5 5 5 6 6 6 6 6 6 6 6 1.00 1.00 1.00 1.00 1.00 1.00 1.12 1.12 1.21 1.21 1.27 1.27 1.37 1.37 .37 .37 .37 .37 .37 .37 .53 .53 .53 .53 .59 .59 .72 .72 .27 .27 .27 .27 .27 .27 .32 .32 .31 .31 .35 .35 .52 .52 .81 .81 .81 .81 .81 .81 .86 .86 .94 .94 .98 .98 1.02 1.02 Cat. No. RZ22-2** RZ22-4** RZ22-6** RZ22-8** RZ22-10** Self-insulated with high dieletric-strength nylon sleeves, these ring terminals are recommended for temperatures up to 105°C. An inner bronze insulation grip sleeve lengthens the flexing radius of the conductor and eliminates conductor creep. The nylon jacket is color-coded: Color Code Wire Range yellow 26-22 red 22-16 blue 18-14 yellow 12-10 Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please consult tech service. Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) RZ & RAX stock thickness: .02 RA & RB stock thickness: .03 RC stock thickness: .04 ® Dimensions * Not Listed By U.L. CSA ** CSA Listed only U.L. Listed E9809 Installing tools: WT2000, WT112M, WT145C, WT1455, ERG-2001, ERG-2003, WT145A, WT2130A (RC,RBC) Installing tool: WT1452 (RZ series only) 80 Telecom 1-800-685-9452 Nylon Terminals Nylon Insulated Ring—Expanded Insulation Grip Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M RB14-4X 100 RB1324 1000 RB14-6X 100 RB854 1000 RB14-8X 100 RB864 1000 RB14-10X 100 RB874 1000 RB14-14X 100 RB714 1000 RB14-516X 100 RB724 1000 RB14-38X 100 RB734 1000 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 .190 .190 .190 .190 .190 .190 .190 .190 .190 .190 .190 .190 .190 .190 #4 #4 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 4 4 4 4 5 5 5 5 6 6 6 6 6 6 .80 .80 .95 .95 .95 .95 .95 .95 1.16 1.16 1.16 1.16 1.25 1.25 .26 .26 .31 .31 .31 .31 .31 .31 .47 .47 .47 .47 .53 .53 .14 .14 .25 .25 .25 .25 .25 .25 .31 .31 .31 .31 .42 .42 .67 .67 .79 .79 .79 .79 .79 .79 .92 .92 .92 .92 .95 .95 RC10-6X RC334 RC10-8X RC864 RC10-10X RC364 RC10-14X RC714 RC10-516X RC704 RC10-38X RC734 RC10-12X 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 .250 .250 .250 .250 .250 .250 .250 .250 .250 .250 .250 .250 .250 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 5 5 5 5 5 5 6 6 6 6 6 6 6 1.10 1.10 1.10 1.10 1.10 1.10 1.22 1.22 1.32 1.32 1.38 1.38 1.48 .37 .37 .37 .37 .37 .37 .53 .53 .53 .53 .59 .59 .72 .27 .27 .27 .27 .27 .27 .32 .32 .31 .31 .35 .35 .52 .91 .91 .91 .91 .91 .91 .96 .96 1.05 1.05 1.09 1.09 1.13 Cat. No. Catalog numbers with the suffix X indicate an expanded insulation grip. This means a wider wire entry to accommodate heavy wall insulation. Ring terminals won’t fall free even if the mounting screw loosens. RB stock thickness: .03 RC stock thickness: .04 ® ® 50 500 50 500 50 500 50 500 50 500 50 500 50 Dimensions U.L. Listed E9809 Installing tools: WT2000, WT112M, WT145C, ERG-2001, ERG-2003, WT145A, WT2130A(RC) Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) Telecom 1-800-685-9452 81 Nylon Terminals ® Nylon Insulated Ring Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M RD8-10 RD367 RD8-14 RD717 RD8-516 RD727 RD8-38 RD737 RD8-12 RD757* 25 200 25 200 25 200 25 200 25 200 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 .340 .340 .340 .340 .340 .340 .340 .340 .310 .310 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" 12 12 12 12 12 12 12 12 12 12 1.48 1.48 1.54 1.54 1.63 1.63 1.63 1.63 1.79 1.79 .42 .42 .46 .46 .57 .57 .57 .57 .82 .82 .28 .28 .36 .36 .36 .36 .36 .36 .55 .55 1.29 1.29 1.32 1.32 1.35 1.35 1.35 1.35 1.39 1.39 RD10161 RD10361 RD10711 RD10721 RD10731 200 200 200 200 200 9-8-7AN 9-8-7AN 9-8-7AN 9-8-7AN 9-8-7AN .270 .270 .270 .270 .270 #8 #10 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" 12 12 12 12 12 1.40 1.40 1.45 1.53 1.53 .41 .41 .45 .56 .56 .24 .24 .27 .34 .34 1.20 1.20 1.22 1.25 1.25 RE6-10 RE267 RE6-14 RE717 RE6-516 RE727 RE6-38 RE737 RE6-12 RE757* 20 200 20 200 20 200 20 200 20 200 6-5 6-5 6-5 6-5 6-5 6-5 6-5 6-5 6-5 6-5 .420 .420 .420 .420 .420 .420 .420 .420 .395 .395 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" 16 16 16 16 16 16 16 16 16 16 1.65 1.65 1.65 1.65 1.76 1.76 1.76 1.76 1.83 1.83 .49 .49 .49 .49 .61 .61 .61 .61 .82 .82 .28 .28 .28 .28 .34 .34 .34 .34 .55 .55 1.40 1.40 1.40 1.40 1.47 1.47 1.47 1.47 1.43 1.43 RE10261 RE10711 RE10721 RE10731 200 200 200 200 6-5AN 6-5AN 6-5AN 6-5AN .315 .315 .315 .315 #10 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" 16 16 16 16 1.55 1.55 1.70 1.70 .49 .49 .60 .60 .24 .27 .34 .34 1.31 1.31 1.40 1.40 RF4-10 RF267 RF4-14 RF717 RF4-516 RF727 RF4-38 RF737 RF757* 15 200 15 200 15 200 15 200 200 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 .510 .510 .510 .510 .510 .510 .510 .510 .500 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 21 21 21 21 21 21 23 23 23 1.76 1.76 1.76 1.76 1.84 1.84 1.84 1.84 1.90 .56 .56 .56 .56 .62 .62 .62 .62 .82 .36 .36 .36 .36 .35 .35 .35 .35 .55 1.49 1.49 1.49 1.49 1.53 1.53 1.53 1.53 1.49 RF10261 RF10711 RF10721 RF10731 200 200 200 200 4-3AN 4-3AN 4-3AN 4-3AN .380 .380 .380 .380 #10 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" 26 26 26 26 1.78 1.78 1.80 1.80 .55 .55 .62 .82 .30 .30 .34 .34 1.51 1.51 1.49 1.49 RG2-10 RG267 RG2-14 RG717 RG2-516 RG727 RG2-38 RG737 RG2-12 RG757 10 100 10 100 10 100 10 100 10 100 2-1 2-1 2-1 2-1 2-1 2-1 2-1 2-1 2-1 2-1 .588 .588 .588 .588 .588 .588 .588 .588 .588 .588 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" 42 42 42 42 42 42 42 42 42 42 2.15 2.15 2.15 2.15 2.15 2.15 2.15 2.15 2.35 2.35 .69 .69 .69 .69 .69 .69 .69 .69 .80 .80 .40 .40 .40 .40 .40 .40 .40 .40 .49 .49 1.83 1.83 1.83 1.83 1.83 1.83 1.83 1.83 1.93 1.93 RG9711 RG9731 RG9751 100 100 100 2AN 2AN 2AN 453 .453 .453 48 48 48 2.07 2.07 2.26 .69 .69 .80 .40 .40 .49 1.74 1.74 1.84 Cat. No. C RD, RE, RF stock thickness: .04 RG stock thickness: .05 * Brazed Seam, Lolly-Pop Style Tongue ® 1 4 3 8 1 2 ⁄" ⁄" ⁄" Dimensions AN—Aircraft Wire U.L. Listed E9809 Installing tools: TBM6/TBM6S, WT2130A (RD Series only) Note: Not available on Mylar Tape. 82 Telecom 1-800-685-9452 Nylon Terminals ® Nylon Insulated Ring—continued Stock Thickness: RH = .05 RJ = .06 RK = .06 RL = .07 RM = .07 ® Wt./Lbs. Per 1000 A B C M 1 4 3 8 1 2 54 54 54 2.14 2.14 2.34 .77 .77 .77 .44 .44 .54 1.81 1.81 1.90 .550 .550 .550 1 4 3 8 1 2 80 80 80 2.35 2.35 2.49 .83 .83 .89 .46 .46 .55 1.97 1.97 2.04 1/0 1/0 1/0 1/0 .629 .629 .629 .629 1 4 5 16 3 8 1 2 ⁄" ⁄" ⁄" ⁄" 80 80 80 80 2.14 2.14 2.14 2.34 .77 .77 .77 .77 .43 .43 .43 .54 1.81 1.81 1.81 1.90 100 100 2/0AN 2/0AN .610 .610 3 8 1 2 70 70 2.52 2.60 .93 .93 .55 .55 2.14 2.15 RJ717 RJ727 RJ737 RJ757 100 100 100 100 2/0 2/0 2/0 2/0 .675 .675 .675 .675 1 4 5 16 3 8 1 2 80 80 80 80 2.34 2.34 2.34 2.48 .83 .83 .83 .89 .46 .46 .46 .54 1.96 1.96 1.96 2.03 RL9731 RL9751 100 100 3/0AN 3/0AN .680 .680 3 8 1 2 120 120 2.83 2.83 1.04 1.04 .57 .57 2.36 2.36 RK717 RK727 RK737 100 100 100 3/0 3/0 3/0 .765 .765 .765 1 4 5 16 3 8 84 84 84 2.60 2.60 2.60 .93 .93 .93 .54 .54 .54 2.21 2.21 2.21 RM9731 RM9751 100 100 4/0AN 4/0AN .750 .750 3 8 1 2 160 160 3.00 3.00 1.13 1.13 .66 .66 2.51 2.51 RL737 RL757 100 100 4/0 4/0 .785 .785 3 8 1 2 130 130 2.83 2.83 1.04 1.04 .57 .57 2.35 2.35 RM737 RM747 RM757 100 100 100 250MCM 250MCM 250MCM .868 .868 .868 3 8 7 16 1 2 130 130 130 3.00 3.00 3.00 1.13 1.13 1.13 .65 .65 .65 2.51 2.51 2.51 Cat. No. Pkg. Qty. Wire Range Max. Ins. RH9711 RH9731 RH9751 100 100 100 1AN 1AN 1AN .500 .500 .500 RJ9711 RJ9731 RJ9751 100 100 100 1/0AN 1/0AN 1/0AN RH717 RH727 RH737 RH757 100 100 100 100 RK9731 RK9751 Bolt Hole ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" Dimensions A N—Aircraft Wire U.L. Listed E9809 Installing tools: TBM6/TBM6S, WT2130A (RD Series only) Note: Not available on Mylar Tape. Telecom 1-800-685-9452 83 Terminals ® ® Heat Shrinkable Ring Terminals—Expanded Insulation Support Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M RAS18-6X 100 RAS18-8X 100 RAS18-10X 100 22-18 22-18 22-18 .170 .170 .170 #6 #8 #10 2 3 2 1.23 1.26 1.26 .25 .31 .31 .27 .27 .27 1.10 1.10 1.10 RBS14-6X 100 RBS14-8X 100 RBS14-10X 100 16-14 16-14 16-14 .200 .200 .200 #6 #8 #10 3 3 3 1⁄ 2 1.23 1.23 1.26 .25 .25 .31 .27 .27 .27 1.10 1.10 1.10 RCS10-6X RCS10-8X RCS10-10X RCS10-14X 12-10 12-10 12-10 12-10 .250 .250 .250 .250 #6 #8 #10 1 ⁄ 4" 3 5 5 6 1.34 1.34 1.34 1.34 .31 .37 .37 .49 .27 .27 .27 .32 1.15 1.15 1.15 1.15 Cat. No. These ring terminals are self-insulated with heat shrinkable nylon and internally coated sealant. Upon completed installation, a fully sealed connection is achieved to protect the joint against the degrading effects of galvanic action, corrosion, and environmental exposure. RAS & RBS stock thickness: .03 RCS stock thickness: .04 50 50 50 50 Dimensions U.L. Listed E9809 Installing tool: WT1255 Note: Not available on Mylar Tape. 84 Telecom 1-800-685-9452 Vinyl Terminals ® Vinyl Insulated Ring—Insulation Support Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M 18RA-4 100 RA77 1000 18RA-6 100 RA857 1000 18RA-8 100 RA867 1000 18RA-10 100 RA877 1000 18RA-14 100 RA717 1000 18RA-516 100 RA727 1000 18RA-38 100 RA737 1000 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 .150 .150 .150 .150 .150 .150 .150 .150 .150 .150 .150 .150 .150 .150 #4 #4 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 3 3 3 3 3 3 3 3 4 4 4 4 4 4 .97 .97 .94 .94 .97 .97 .97 .97 1.13 1.13 1.13 1.13 1.24 1.24 .31 .31 .25 .25 .31 .31 .31 .31 .50 .50 .50 .50 .54 .54 .27 .27 .27 .27 .27 .27 .27 .27 .37 .37 .37 .37 .37 .37 .81 .81 .81 .81 .81 .81 .81 .81 .88 .88 .88 .88 .91 .91 14RB-4 100 RB1327 1000 14RB-6 100 RB857 1000 14RB-8 100 RB867 1000 14RB-10 100 RB877 1000 14RB-14 100 RB717 1000 14RB-516 100 RB727 1000 14RB-38 100 RB-737 1000 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 .170 .170 .170 .170 .170 .170 .170 .170 .170 .170 .170 .170 .170 .170 #4 #4 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 3 3 3 3 3 3 3 3 4 4 4 4 4 4 .94 .94 .97 .97 .97 .97 .97 .97 1.14 1.14 1.15 1.15 1.16 1.16 .25 .25 .31 .31 .31 .31 .31 .31 .50 .50 .50 .50 .54 .54 .27 .27 .27 .27 .27 .27 .27 .27 .38 .38 .38 .38 .38 .38 .81 .81 .81 .81 .81 .81 .81 .81 .89 .89 .89 .89 .91 .91 10RC-6 RC337 10RC-8 RC777 10RC-10 RC367 10RC-14 RC717 10RC-516 RC707 10RC-38 RC737 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 .210 .210 .210 .210 .210 .210 .210 .210 .210 .210 .210 .210 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 5 5 5 5 5 5 6 6 6 6 6 6 1.06 1.06 1.06 1.06 1.06 1.06 1.16 1.16 1.17 1.17 1.29 1.29 .31 .31 .31 .31 .31 .31 .50 .50 .50 .50 .59 .59 .27 .27 .27 .27 .27 .27 .27 .27 .37 .37 .44 .44 .90 .90 .90 .90 .90 .90 .90 .90 .92 .92 .99 .99 Cat. No. These ring terminals are self-insulated with a PVC insulation sleeve of extra length to give protection and relieve bending stress at wire’s flex point. Brazed seam barrel is serrated to obtain high pull-out value. Terminal is made of high conductivity electrolytic copper, electro-tin plated. Insulation material is color-coded: Color Code Wire Range red 22-16 blue 18-14 yellow 12-10 Stock Thickness: RA & RB = .03 RC = .04 ® Pkg. Qty. 50 500 50 500 50 500 50 500 50 500 50 500 Dimensions U.L. Listed E9809 Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT2130A (RC, RBC) Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) Telecom 1-800-685-9452 85 Vinyl Terminals Vinyl Insulated Ring—Expanded Insulation Support Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M 18RA-6X 18RA-8X RA867-170 18RA-10X RA877-170 18RA-14X RA727-170 18RA-38X 100 100 1000 100 1000 100 1000 100 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 .170 .170 .170 .170 .170 .170 .170 .170 #6 #8 #8 #10 #10 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" 3 3 3 3 3 4 4 4 .97 .97 .97 .97 .97 1.13 1.13 1.24 .31 .31 .31 .31 .31 .50 .50 .54 .27 .27 .27 .27 .27 .37 .37 .35 .81 .81 .81 .81 .81 .88 .88 .91 14RB-4X 14RB-6X RB857-200 14RB-8X RB867-200 14RB-10X RB877-200 14RB-14X RB717-200 14RB-516X 14RB-38X 100 100 1000 100 1000 100 1000 100 1000 100 100 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 .200 .200 .200 .200 .200 .200 .200 .200 .200 .200 .200 #4 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" 3 3 3 3 3 3 3 4 4 4 4 .94 .97 .97 .97 .97 .97 .97 1.14 1.14 1.15 1.16 .25 .31 .31 .31 .31 .31 .31 .50 .50 .50 .54 .27 .27 .27 .27 .27 .27 .27 .38 .38 .38 .35 .81 .81 .81 .81 .81 .81 .81 .89 .89 .89 .91 10RC-6X RC337-250 10RC-8X RC777-250 10RC-10X RC367-250 10RC-14X RC717-250 10RC-516X 10RC-38X RC737-250 50 500 50 500 50 500 50 500 50 50 500 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 .250 .250 .250 .250 .250 .250 .250 .250 .250 .250 .250 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 5 5 5 5 5 5 6 6 6 6 6 1.06 1.06 1.06 1.06 1.06 1.06 1.16 1.16 1.17 1.29 1.29 .31 .31 .31 .31 .31 .31 .50 .50 .50 .59 .59 .27 .27 .27 .27 .27 .27 .27 .27 .37 .44 .44 .90 .90 .90 .90 .90 .90 .90 .90 .92 .99 .99 Cat. No. Catalog numbers with the suffix X indicate an expanded insulation support. This means a wider wire entry to accommodate heavy wall insulation. Ring terminals won’t fall free even if the mounting screw loosens. Stock Thickness: RA & RB = RC = .03 .04 ® ® Dimensions U.L. Listed E9809 Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT2130A (RC, RBC) Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) 86 Telecom 1-800-685-9452 U.L. 94V-0 Rated Ring Terminals ® Vinyl Insulated Ring ® Max. Ins. Dia. Wire Range A Series RDV—Aircraft Wire AN RDV10161 #8 .270 RDV10361 #10 .270 1 RDV10711 ⁄ 4" .270 9,8,7 9,8,7 9,8,7 1.40 1.40 1.45 Cat. No. Stud Size Dimensions B C .41 .41 .45 .24 .24 .27 C Note: Not available on Mylar Tape. Stock Thickness: .04 * Brazed Seam, Lolly-Pop Style Tongue NEW RD and RE sizes now available with a U.L. 94V-O Vinyl Insulator Telecom 1-800-685-9452 87 M 1.20 1.20 1.22 Tefzel® Insulated Terminals ® Tefzel Insulated Ring—Insulation Grip Cat. No. Max. Ins. Dia. Stud Size Wire Range A ® Dimensions B C M Series RAT—For U.L. 94V-O Flamability Rating/High Temperature and Chemical Resistance. RAT853 #6 .140 22-18 .81 .25 .25 .69 RAT863 #8 .140 22-18 .84 .31 .25 .69 RAT873 #10 .140 22-18 .84 .31 .25 .69 1 RAT713 ⁄ 4" .140 22-18 1.07 .46 .31 .84 Stock Thickness: RAT & RBT = .03 RCT = .04 Package Quantities: RAT & RBT = 1000 pcs. RCT = 500 pcs. Series RBT RBT853 RBT863 RBT873 RBT713 #6 #8 #10 1 ⁄ 4" .170 .170 .170 .170 16-14 16-14 16-14 16-14 .84 .84 .84 1.08 .31 .31 .31 .46 .25 .25 .25 .31 .69 .69 .69 .81 Series RCT RCT333 RCT863 RCT363 RCT713 RCT703 RCT733** #6 #8 #10 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" .210 .210 .210 .210 .210 .210 12-10 12-10 12-10 12-10 12-10 12-10 1.00 1.00 1.00 1.11 1.23 1.29 .37 .37 .37 .52 .52 .58 .27 .27 .27 .32 .31 .35 .81 .81 .81 .85 .96 1.00 ** Not available on tape. U.L. Listed E9809 Installing Tools: ERG2001, WT112M, WT145C. Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) 88 Telecom 1-800-685-9452 Non-Insulated Terminals ® Non-Insulated Ring Cat. No. These non-insulated ring terminals are made of electrolytic copper for high conductivity. They can be installed with crimping tools having a single indentor or double indentor (recommended for solid wire). Serrated barrel increases grip on wire. Wire range identification is stamped on the tongue of each terminal. Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and applicaton dies). Consult tech service. Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) Stock Thickness: A & B = .03 BC = .05 C = .04 Pkg. Qty. Wire Range ® Bolt Hole Wt./Lbs. Per 1000 A B C M Dimensions A18-4 A18-6 A85 A18-8 A86 A18-10 A87 A18-14 A71 A72 A73 A18-12 A75 100 100 1000 100 1000 100 1000 100 1000 1000 1000 100 1000 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 #4 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" 2 2 2 2 2 2 2 3 3 3 3 3 3 .75 .72 .72 .75 .75 .75 .75 .92 .92 .92 .99 1.06 1.06 .31 .25 .25 .31 .31 .31 .31 .50 .50 .50 .54 .72 .72 .27 .27 .27 .27 .27 .27 .27 .37 .37 .37 .35 .38 .38 .59 .59 .59 .59 .59 .59 .59 .67 .67 .67 .67 .70 .70 B14-4 B132 B14-6 B133 B14-8 B86 B14-10 B87 B14-14 B71 B14-516 B72 B14-38 B73 B14-12 B75 B85 B134 100 1000 100 1000 100 1000 100 1000 100 1000 100 1000 100 1000 100 1000 1000 1000 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 #4 #4 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" #6 #8 2 2 2 2 3 3 3 3 6 6 6 6 6 6 6 6 6 6 .72 .72 .75 .75 .75 .75 .75 .75 .93 .93 .93 .93 .96 .96 1.06 1.06 .75 .72 .25 .25 .31 .31 .31 .31 .31 .31 .50 .50 .50 .50 .54 .54 .72 .72 .31 .25 .27 .27 .27 .27 .27 .27 .27 .27 .38 .38 .38 .38 .35 .35 .38 .38 .27 .27 .59 .59 .59 .59 .59 .59 .59 .59 .68 .68 .68 .68 .68 .68 .70 .70 .59 .59 4 4 4 4 5 5 5 5 6 6 6 6 6 6 .81 .81 .87 .87 .87 .87 .93 .93 1.04 1.04 1.09 1.09 1.32 1.32 .25 .25 .39 .39 .39 .39 .51 .51 .54 .54 .63 .63 .76 .76 .29 .29 .29 .29 .29 .29 .29 .29 .38 .38 .38 .38 .54 .54 .68 .68 .68 .68 .68 .68 .68 .68 .77 .77 .77 .77 .94 .94 4 4 5 5 5 5 7 7 7 8 8 7 7 7 7 7 .82 .82 .82 .82 .85 .85 .82 .91 .91 .98 .98 1.10 1.10 1.10 1.21 1.21 .31 .31 .31 .31 .38 .38 .31 .50 .50 .50 .50 .59 .59 .59 .72 .72 .27 .27 .27 .27 .27 .27 .27 .27 .27 .38 .38 .45 .45 .45 .38 .38 .66 .66 .66 .66 .66 .66 .66 .66 .66 .73 .73 .80 .80 .80 .84 .84 BC14-6 BC85 BC14-8 BC86 BC14-10 BC87 BC14-14 BC71 BC14-516 BC72 BC14-38 BC79 BC14-12 BC75 5 0 heavy duty 16-14 # 6 500 use C tooling # 6 5 0 heavy duty 16-14 # 8 500 use C tooling # 8 5 0 heavy duty 16-14 #10 500use C tooling #10 5 0 heavy duty 16-14 1⁄ 4" 1 500 use C tooling ⁄ 4" 5 0 heavy duty 16-14 5⁄ 1 6" 500 use C tooling 5⁄ 1 6" 5 0 heavy duty 16-14 3⁄ 8" 3 500 use C tooling ⁄ 8" 5 0 heavy duty 16-14 1⁄ 2" 1 500 use C tooling ⁄ 2" C10-6 50 C33 500 C10-8 50 C77 500 C10-10 50 C26 500 C36 1000 C10-14 50 C71 500 C10-516 50 C70 500 C72 1000 C10-38 50 C73 500 C10-12 50 C75 500 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 #6 #6 #8 #8 #10 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" U.L. Listed E9809 Installing tools: WT111M, WT112M, WT110M, ERG-2002, WT1300, WT2000, WT3155A Telecom 1-800-685-9452 89 Non-Insulated Terminals ® Non-Insulated Ring Pkg. Qty. Wire Range Bolt Hole Wt./Lbs. Per 1000 A B C M D8-10 D26* D8-14 D71* D8-516 D72* D8-38 D73* D8-12 D75* 25 200 25 200 25 200 25 200 25 200 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" 16 16 14 14 16 16 14 14 14 14 1.13 1.13 1.13 1.13 1.32 1.32 1.32 1.32 1.49 1.49 .48 .48 .48 .48 .59 .59 .59 .59 .82 .82 .36 .36 .36 .36 .49 .49 .49 .49 .55 .55 .90 .90 .90 .90 1.03 1.03 1.03 1.03 1.09 1.09 D10161 D10361 D10711 D10721 D10731 D975* 200 200 200 200 200 200 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 #8 #10 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" 1 ⁄ 2" 12 12 12 12 12 12 1.15 1.15 1.20 1.28 1.28 1.46 .41 .41 .45 .56 .56 .83 .28 .28 .36 .36 .36 .49 .95 .95 .97 1.00 1.00 1.06 E6-10 E26* E6-14 E71* E6-516 E72* E6-38 E73* E6-12 E75* 20 200 20 200 20 200 20 200 20 200 6-5 6-5 6-5 6-5 6-5 6-5 6-5 6-5 6-5 6-5 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" 17 17 20 20 20 20 20 20 20 20 1.13 1.13 1.13 1.13 1.32 1.32 1.32 1.32 1.49 1.49 .48 .48 .48 .48 .60 .60 .60 .60 .82 .82 .36 .36 .36 .36 .49 .49 .49 .49 .55 .55 .90 .90 .90 .90 1.03 1.03 1.03 1.03 1.08 1.08 E10261 E10711 E10721 E10731 200 200 200 200 6-5 6-5 6-5 6-5 #10 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" 14 14 14 14 1.26 1.26 1.38 1.38 .49 .49 .60 .60 .24 .27 .34 .34 1.02 .99 1.04 1.04 F4-10 F26* F4-14 F71* F4-516 F72* F4-38 F73* F4-12 F75* 20 200 20 200 20 200 20 200 20 200 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 #10 #10 1 ⁄ 4" 1 ⁄ 4" 5 ⁄ 1 6" 5 ⁄ 1 6" 3 ⁄ 8" 3 ⁄ 8" 1 ⁄ 2" 1 ⁄ 2" 24 24 25 25 25 25 25 25 25 25 1.16 1.16 1.16 1.16 1.35 1.35 1.35 1.35 1.52 1.52 .48 .48 .48 .48 .60 .60 .60 .60 .82 .82 .36 .36 .36 .36 .49 .49 .49 .49 .55 .55 .93 .93 .93 .93 1.06 1.06 1.06 1.06 1.11 1.11 F10261 F10711 F10721 F10731 F975* 100 100 100 100 200 4-3 4-3 4-3 4-3 4-3 #10 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" 1 ⁄ 2" 20 20 20 20 20 1.37 1.37 1.42 1.42 1.49 .55 .55 .62 .62 .83 .30 .30 .34 .34 .45 1.07 1.07 1.08 1.08 1.10 Cat. No. C These non-insulated ring terminals are made of electrolytic copper for high conductivity. They can be installed with crimping tools having a single indentor or double indentor (recommended for solid wire). Serrated barrel increases grip on wire. Wire range identification is stamped on the tongue of each terminal. Stock Thickness: D & E = .06 F = .07 D10, E10, F10 = .04 D975 & F975 = .04 * Brazed Seam, Lolly-Pop Style Tongue ® Dimensions Installing tools: WT115A D, E, F and G, WT3155A, (D-Series only), TBM6/TBM6S, WT3175 Installing dies: 11802 INDENTOR (D-E-F-G), D-11803-NEST, E-11805-NEST, F-11806NEST (all ordered separately) Note: Not available on Mylar Tape. 90 Telecom 1-800-685-9452 Non-Insulated Terminals ® Non-Insulated Ring Cat. No. These non-insulated ring terminals are made of electrolytic copper for high conductivity. They can be installed with crimping tools having a single indentor or double indentor (recommended for solid wire). Serrated barrel increases grip on wire. Wire range identification is stamped on the tongue of each terminal. Stock Thickness: G & H = .05 J & K = .06 L & M = .07 ® Pkg. Qty. Wire Range Bolt Hole G2-14 G2-516 G2-38 G2-12 10 10 10 10 2-1 2-1 2-1 2-1 1 4 5 16 3 8 1 2 H10-14 J20-38 K30-38 L40-38 M250-38 10 10 5 5 5 1/0 2/0 3/0 4/0 250MCM 1 4 3 8 3 8 3 8 3 8 ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" Wt./Lbs. Per 1000 A B C M 50 50 50 50 1.59 1.59 1.59 1.79 .69 .69 .69 .80 .40 .40 .40 .49 1.26 1.26 1.26 1.36 50 70 82 100 135 1.65 1.84 2.08 2.25 2.40 .77 .83 .93 1.04 1.12 .43 .46 .54 .57 .65 1.32 1.46 1.69 1.77 1.91 40 40 40 40 40 40 1.59 1.59 1.59 1.59 1.79 1.79 .69 .69 .69 .69 .80 .80 .40 .40 .40 .40 .49 .49 1.26 1.26 1.26 1.26 1.36 1.36 Dimensions G926 G971 G972 G973 G975 G976 100 100 100 100 100 100 1-2 1-2 1-2 1-2 1-2 1-2 H971 H972 H973 H975 H976 100 100 100 100 100 1AN-1/0 1AN-1/0 1AN-1/0 1AN-1/0 1AN-1/0 1 4 5 16 3 8 1 2 5 8 50 50 50 50 50 1.65 1.65 1.65 1.85 1.85 .77 .77 .77 .77 .77 .43 .43 .43 .54 .54 1.32 1.32 1.32 1.41 1.41 J971 J972 J973 J974 J975 J976 100 100 100 100 100 100 1/0AN-2/0 1/0AN-2/0 1/0AN-2/0 1/0AN-2/0 1/0AN-2/0 1/0AN-2/0 1 4 5 16 3 8 7 16 1 2 5 8 60 60 60 60 60 60 1.94 1.94 1.99 1.99 1.99 1.99 .84 .84 .84 .89 .89 .89 .48 .48 .53 .51 .51 .51 1.53 1.53 1.58 1.56 1.56 1.56 K971 K972 K973 K974 K975 K976 100 100 100 100 100 100 2/0AN-3/0 2/0AN-3/0 2/0AN-3/0 2/0AN-3/0 2/0AN-3/0 2/0AN-3/0 1 4 5 16 3 8 7 16 1 2 5 8 ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" 76 76 76 76 76 76 2.08 2.08 2.08 2.08 2.08 2.08 .93 .93 .93 .93 .93 .93 .54 .54 .54 .54 .54 .54 1.69 1.69 1.69 1.70 1.70 1.70 L973 L974 L975 L976 100 100 100 100 3/0AN-4/0 3/0AN-4/0 3/0AN-4/0 3/0AN-4/0 3 8 ⁄" ⁄" ⁄" ⁄" 92 92 92 92 2.25 2.25 2.25 2.25 1.04 1.04 1.04 1.04 .57 .57 .57 .57 1.77 1.77 1.77 1.77 M972 M973 M974 M975 100 100 100 100 4/0AN-250MCM 5⁄ 1 6" 4/0AN-250MCM 3⁄ 8" 7 4/0AN-250MCM ⁄ 1 6" 1 4/0AN-250MCM ⁄ 2" 112 112 112 112 2.28 2.40 2.40 2.40 1.12 1.12 1.12 1.12 .62 .65 .65 .65 1.90 1.91 1.91 1.91 #10 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" 1 ⁄ 2" 5 ⁄ 8" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" ⁄" 7 16 1 2 5 8 AN—Aircraft Wire Installing tools: TBM6/TBM6S, WT3175 (G, H, J Series only) Note: Not available on Mylar Tape. Telecom 1-800-685-9452 91 Flag Terminals ® Non-Insulated Flag ® Wire Range Bolt Hole Wt./Lbs. Per 1000 A B C M AB14-6A 100 AB51 1000 AB14-8A 100 AB52 1000 AB14-10A 100 AB53 1000 22-14 22-14 22-14 22-14 22-14 22-14 #6 #6 #8 #8 #10 #10 2 1⁄ 2 2 1⁄ 2 1 2⁄ 2 1 2⁄ 2 1 2⁄ 2 1 2⁄ 2 .55 .55 .55 .55 .55 .55 .31 .31 .31 .31 .31 .31 .22 .22 .22 .22 .22 .22 .39 .39 .39 .39 .39 .39 C51 C10-8A C52 C10-10A C53 500 50 500 50 500 12-10 12-10 12-10 12-10 12-10 #6 #8 #8 #10 #10 5 5 5 5 5 .66 .66 .66 .66 .66 .31 .31 .31 .31 .31 .25 .25 .25 .25 .25 .48 .48 .48 .48 .48 Flag terminals allow a 90° connection to the terminal block without bending the wire. D236 D226 D271 200 200 200 9,8,7 9,8,7 9,8,7 #10 #10 1 ⁄ 4" — — — .83 .88 .92 .50 .50 .50 .25 .29 .33 .59 .64 .68 Stock Thickness: AB = .03 C = .04 D = .06 E = .06 F = .07 G = .08 E226 E271 E272 200 200 200 6,5 6,5 6,5 #10 1 ⁄ 4" 5 ⁄ 1 6" — — — .93 .97 1.05 .50 .50 .50 .29 .33 .41 .69 .73 .81 F226 F271 F272 F273 200 200 200 200 4,3 4,3 4,3 4,3 #10 1 ⁄ 4" 5 ⁄ 1 6" 3 ⁄ 8" — — — — 1.07 1.10 1.18 1.20 .56 .63 .63 .63 .33 .33 .41 .43 .80 .80 .88 .90 G671 G672 G673 100 100 100 2 2 2 — — — 1.20 1.28 1.32 .63 .63 .63 .33 .41 .46 .89 .97 1.02 Cat. No. Pkg. Qty. 1 4 5 16 3 8 ⁄" ⁄" ⁄" Dimensions U.L. Listed E9809 Installing tools: WT119, ERG-2004, WT129 = D, E, F, G Note: Not available on Mylar Tape. 92 Telecom 1-800-685-9452 Fork Terminals ® Nylon Insulated Fork—Insulation Grip Cat. No. Fork terminals with nylon insulation sleeves, recommended for temperatures up to 105°C. Inner bronze insulation grip sleeve lengthens flex radius of conductor and eliminates conductor creep. Nylon jacket is color-coded. Stock thickness same as ring terminal of same size. ® Wt./Lbs. Per 1000 A B C M #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 3 3 3 3 3 3 4 4 .83 .83 .86 .86 .86 .86 .95 .95 .25 .25 .31 .31 .31 .31 .44 .44 .25 .25 .25 .25 .25 .25 .31 .31 .71 .71 .71 .71 .71 .71 .70 .70 .162 .162 .162 .162 .162 .162 .162 .162 .162 .190 .190 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" #6 #8 #10 3 1⁄ 2 3 1⁄ 2 3 1⁄ 2 3 1⁄ 2 4 4 4 4 6 6 6 .87 .87 .87 .87 .87 .87 .95 .95 .74 .95 .95 .31 .31 .31 .31 .38 .38 .44 .44 .28 .31 .31 .25 .25 .25 .25 .25 .25 .28 .28 .16 .25 .25 .71 .71 .71 .71 .71 .71 .74 .74 .60 .79 .79 .210 .210 .210 .210 .210 .210 .210 .210 .250 .250 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" #8 #10 6 6 6 6 6 6 6 6 6 6 .97 .97 1.00 1.00 1.00 1.00 1.12 1.12 1.10 1.10 .31 .31 .37 .37 .37 .37 .50 .50 .37 .37 .27 .27 .27 .27 .27 .27 .27 .27 .27 .27 .81 .81 .81 .81 .81 .81 .86 .86 .91 .91 Pkg. Qty. Wire Range Max. Ins. Bolt Hole RA18-6F RA1103 RA18-8F RA1123 RA18-10F RA1153 RA18-14F RA1163 100 1000 100 1000 100 1000 100 1000 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 .136 .136 .136 .136 .136 .136 .136 .136 RB14-6F RB1113 RB14-8F RB1123 RB14-10F RB1153 RB14-14F RB1163 RB1103 RB1124 RB1154 100 1000 100 1000 100 1000 100 1000 1000 1000 1000 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 RC10-6F 50 RC1113 500 RC10-8F 50 RC1123 500 RC10-10F 50 RC1153 500 RC10-14F 50 RC1163 500 RC1124 1000 RC1154 1000 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 Dimensions U.L. Listed E9809 Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT145A, WT2130A (RC) Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) Telecom 1-800-685-9452 93 Fork Terminals ® ® Nylon Insulated Fork Flanged Tongue—Insulation Grip Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M RA18-6FS 100 RA1203 1000 RA18-8FS 100 RA1223 1000 RA18-10FS 100 RA1253 1000 22-16 22-16 22-16 22-16 22-16 22-16 .136 .136 .136 .136 .136 .136 #6 #6 #8 #8 #10 #10 3 3 3 3 3 3 .75 .75 .89 .89 .93 .93 .28 .28 .31 .31 .38 .38 .16 .16 .23 .23 .26 .26 .62 .62 .65 .65 .68 .68 RB14-6FS 100 RB1203 1000 RB14-8FS 100 RB1223 1000 RB14-10FS 100 RB1253 1000 18-14 18-14 18-14 18-14 18-14 18-14 .162 .162 .162 .162 .162 .162 #6 #6 #8 #8 #10 #10 4 4 4 4 4 4 .74 .74 .89 .89 .94 .94 .28 .28 .31 .31 .38 .38 .16 .16 .23 .23 .27 .27 .60 .60 .66 .66 .69 .69 RC10-8FS 50 RC1223 500 RC10-10FS 50 RC1253 500 RC1254 1000 12-10 12-10 12-10 12-10 12-10 .210 .210 .210 .210 .250 #8 #8 #10 #10 #10 5 5 5 5 5 .97 .97 1.00 1.00 1.12 .34 .34 .38 .38 .38 .23 .23 .26 .26 .26 .73 .73 .74 .74 .86 Cat. No. C B M A Fork terminals allow easy installation because screw needs only to be loosened. Suffix S indicates a flanged-tongue fork with turned up tips for extra holding protection. Stock thickness same as ring terminal of same size. Dimensions U.L. Listed E9809 Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT145A, WT2130A (RC) turned up toes Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) 94 Telecom 1-800-685-9452 Fork Terminals ® Vinyl Insulated Fork—Insulation Support Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M 18RA-6F RA1167 18RA-8F RA1147 18RA-10F RA1157 100 1000 100 1000 100 1000 22-16 22-16 22-16 22-16 22-16 22-16 .150 .150 .150 .150 .150 .150 #6 #6 #8 #8 #10 #10 5 5 5 5 5 5 .94 .94 .97 .97 .97 .97 .25 .25 .31 .31 .31 .31 .27 .27 .27 .27 .27 .27 .81 .81 .81 .81 .81 .81 14RB-6F RB647 14RB-6FS† 14RB-8F RB657 14RB-10F RB1157 14RB-14F RB1717 100 1000 100 100 1000 100 1000 100 1000 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 .170 .170 .170 .170 .170 .170 .170 .170 .170 #6 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 6 6 6 6 6 6 6 6 6 .97 .97 .89 .97 .97 .97 .97 1.11 1.11 .31 .31 .30 .31 .31 .31 .31 .44 .44 .27 .27 .25 .27 .27 .27 .27 .38 .38 .81 .81 .75 .81 .81 .81 .81 .89 .89 50 500 50 500 50 500 50 500 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 .210 .210 .210 .210 .210 .210 .210 .210 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 7 7 7 7 7 7 7 7 1.09 1.09 1.09 1.09 1.09 1.09 1.15 1.15 .38 .38 .38 .38 .38 .38 .50 .50 .27 .27 .27 .27 .27 .27 .37 .37 .90 .90 .90 .90 .90 .90 .90 .90 Cat. No. These fork terminals have extra-long PVC insulation sleeve for protection and stress relief at wire’s flex point. Brazed seam barrel is serrated for high pull-out value. Terminal is high conductivity electrolytic copper, electro-tin plated. Insulation is color-coded. Stock thickness same as ring terminal of same size. ® 10RC-6F RC1337 10RC-8F RC1147 10RC-10F RC1157 10RC-14F RC1167 Dimensions U.L. Listed E9809 Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT2130A (RC) † Turned-up toes Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) Telecom 1-800-685-9452 95 Fork Terminals ® Vinyl Insulation Fork—Expanded Insulation Support Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M 18RA-6FX 100 RA1167-170 1000 18RA-8FX 100 RA1147-170 1000 18RA-10FX 100 RA1157-170 1000 22-16 22-16 22-16 22-16 22-16 22-16 .170 .170 .170 .170 .170 .170 #6 #6 #8 #8 #10 #10 5 5 5 5 5 5 .94 .94 .97 .97 .97 .97 .25 .25 .31 .31 .31 .31 .27 .27 .27 .27 .27 .27 .81 .81 .81 .81 .81 .81 14RB-6FX 100 RB647-200 1000 14RB-8FX 100 RB657-200 1000 14RB-10FX 100 RB1157-200 1000 18-14 18-14 18-14 18-14 18-14 18-14 .200 .200 .200 .200 .200 .200 #6 #6 #8 #8 #10 #10 6 6 6 6 6 6 .97 .97 .97 .97 .97 .97 .31 .31 .31 .31 .31 .31 .27 .27 .27 .27 .27 .27 .81 .81 .81 .81 .81 .81 10RC-8FX RC1147-250 10RC-10FX RC1157-250 10RC-14FX 12-10 12-10 12-10 12-10 12-10 .250 .250 .250 .250 .250 #8 #8 #10 #10 1 ⁄ 4" 7 7 7 7 7 1.09 1.09 1.09 1.09 1.15 .38 .38 .38 .38 .50 .27 .27 .27 .27 .37 .90 .90 .90 .90 .90 Cat. No. Fork terminals allow easy installation since the mounting screw does not have to be completely removed. Catalog numbers with the suffix X indicate an expanded insulation support. This means a wider wire entry to accommodate heavy wall insulation. Stock thickness same as ring terminal of same size. ® 50 500 50 500 50 Dimensions U.L. Listed E9809 Installing tools: WT145C, WT2000, WT112M, ERG2001, ERG2003, WT2130A (RC) Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) 96 Telecom 1-800-685-9452 Fork Terminals ® Non-Insulated Fork Cat. No. These non-insulated fork terminals are made of electrolytic copper for high conductivity. They can be installed with crimping tools having a single indentor or double indentor (recommended for solid wire). Serrated barrel increase grip on wire. Wire range identification is stamped on the tongue of each terminal. Catalog numbers with the suffix S indicate a flanged-tongue fork with turned-up tips for extra holding protection in the event the mounting screw loosens. Stock thickness same as ring terminal of same turned up toes size. Pkg. Qty. ® Wire Range Bolt Hole Wt./Lbs. Per 1000 A Dimensions B C M A18-6F A116 A18-8F A114 A18-10F A115 100 1000 100 1000 100 1000 22-16 22-16 22-16 22-16 22-16 22-16 #6 #6 #8 #8 #10 #10 4 4 4 4 4 4 .72 .72 .75 .75 .75 .75 .25 .25 .31 .31 .31 .31 .27 .27 .27 .27 .27 .27 .59 .59 .59 .59 .59 .59 B14-6F B64 B19† B14-8F B65 B14-10F B115 B14-14F 100 1000 1000 100 1000 100 1000 100 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 #6 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 6 6 6 6 6 6 6 6 .75 .75 .66 .75 .75 .75 .75 .90 .31 .31 .25 .31 .31 .31 .31 .44 .27 .27 .13 .27 .27 .27 .27 .38 .59 .59 .50 .59 .59 .59 .59 .68 C10-6F C133 C10-8F C114 C10-10F C115 C10-14F C116 50 500 50 500 50 500 50 50 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 #6 #6 #10 #10 #10 #10 1 ⁄ 4" 1 ⁄ 4" 7 7 7 7 7 7 7 7 .77 .77 .82 .82 .82 .82 .98 1.15 .31 .31 .38 .38 .38 .38 .50 .50 .27 .27 .27 .27 .27 .27 .37 .37 .63 .63 .63 .63 .63 .63 .73 .90 U.L. Listed E9809 Installing tools: WT111C, WT112M, WT110M, WT2000, ERG2002, ERG2003, WT1300, WT3155A † Turned-up toes Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) Telecom 1-800-685-9452 97 Locking Fork Terminals Locking fork terminals have a specially designed tongue that lets them go on like a fork and stay on like a ring. ® Nylon Insulated Locking Fork—Insulation Grip Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M RA18-6FL RA2213 RA18-8FL RA2243 RA18-10FL RA2253 100 1000 100 1000 100 1000 22-16 22-16 22-16 22-16 22-16 22-16 .136 .136 .136 .136 .136 .136 #6 #6 #8 #8 #10 #10 5 5 5 5 5 5 .86 .86 .86 .86 .86 .86 .25 .25 .29 .29 .29 .29 .25 .25 .25 .25 .25 .25 .71 .71 .71 .71 .71 .71 RB14-6FL RB2213 RB2214 RB14-8FL RB2233 RB14-10FL RB2253 RB2254 100 1000 1000 100 1000 100 1000 1000 18-14 18-14 18-14 18-14 18-14 18-14 18-14 .162 .162 .190 .162 .162 .162 .162 .190 #6 #6 #6 #8 #8 #10 #10 #10 6 6 6 6 6 6 6 6 .87 .87 .95 .87 .87 .87 .87 .95 .25 .25 .25 .29 .29 .29 .29 .29 .25 .25 .25 .25 .25 .25 .25 .25 .71 .71 .79 .71 .71 .71 .71 .71 RC10-6FL RC2203 RC2204 RC10-8FL RC2213 RC10-10FL RC2223 RC2224 RC10-14FL RC2233 50 500 1000 50 500 50 500 1000 50 500 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 .210 .210 .250 .210 .210 .210 .210 .250 .210 .210 #6 #6 #6 #8 #8 #10 #10 #10 1 ⁄ 4" 1 ⁄ 4" 8 8 8 8 8 8 8 .97 .97 1.07 1.00 1.00 1.00 1.00 1.10 1.12 1.12 .31 .31 .31 .37 .37 .37 .37 .37 .50 .50 .27 .27 .27 .27 .27 .27 .27 .27 .32 .32 .81 .81 .91 .81 .81 .81 .81 .91 .86 .86 Cat. No. Stock thickness same as ring terminal of same size. ® 8 8 Dimensions U.L. Listed E9809 U.S. Pat. 3,590,387 Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M, WT145A, WT2130A (RC) Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) 98 Telecom 1-800-685-9452 Locking Fork Terminals ® Vinyl Insulated Locking Fork—Insulation Support Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M 18RA-6FL RA2217 RA2227 18RA-8FL RA2247 18RA-10FL RA2257 100 1000 1000 100 1000 100 1000 22-16 22-16 22-16 22-16 22-16 22-16 22-16 .150 .150 .155 .150 .150 .150 .150 #6 #6 #6 #8 #8 #10 #10 5 5 5 5 5 5 5 .97 .97 .97 .97 .97 .97 .97 .25 .25 .29 .29 .29 .29 .29 .25 .25 — .25 .25 .25 .25 .81 .81 .81 .81 .81 .81 .81 14RB-6FL RB2207 RB2217 14RB-8FL RB2237 14RB-10FL RB2257 100 1000 1000 100 1000 100 1000 18-14 18-14 18-14 18-14 18-14 18-14 18-14 .170 .170 .170 .170 .170 .170 .170 #6 #6 #6 #8 #8 #10 #10 6 6 6 6 6 6 6 .97 .97 .97 .97 .97 .97 .97 .25 .25 .29 .29 .29 .29 .29 .27 .27 .27 .27 .27 .27 .27 .81 .81 .81 .81 .81 .81 .81 10RC-6FL RC2207 10RC-8FL RC2217 10RC-10FL RC2227 10RC-14FL RC2237 50 500 50 500 50 500 50 500 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 .220 .220 .220 .220 .220 .220 .220 .220 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 1 ⁄ 4" 8 8 8 8 8 8 8 8 1.09 1.09 1.09 1.09 1.09 1.09 1.09 1.09 .31 .31 .37 .37 .37 .37 .49 .49 .27 .27 .27 .27 .27 .27 .27 .27 .90 .90 .90 .90 .90 .90 .90 .90 Cat. No. Stock thickness same as ring terminal of same size. ® Dimensions U.L. Listed E9809 U.S. Pat. 3,590,387 Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) Telecom 1-800-685-9452 99 Locking Fork Terminals ® ® Vinyl Insulated Locking Fork—Expanded Insulation Support Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 A B C M 18RA-6FLX 100 18RA-8FLX 100 18RA-10FLX 100 RA2257-170 1000 22-16 22-16 22-16 22-16 .170 .170 .170 .170 #6 #8 #10 #10 5 5 5 5 .97 .97 .97 .97 .25 .29 .29 .29 .25 .25 .25 .25 .81 .81 .81 .81 14RB-6FLX RB2207-200 RB2217-200 14RB-8FLX RB2237-200 14RB-10FLX RB2257-200 100 1000 1000 100 1000 100 1000 18-14 18-14 18-14 18-14 18-14 18-14 18-14 .200 .200 .200 .200 .200 .200 .200 #6 #6 #6 #8 #8 #10 #10 6 6 6 6 6 6 6 .97 .97 .97 .97 .97 .97 .97 .31 .31 .29 .31 .31 .31 .31 .27 .27 .27 .27 .27 .27 .27 .81 .81 .81 .81 .81 .81 .81 10RC-6FLX RC2207-250 10RC-8FLX 10RC-10FLX RC2227-250 10RC-14FLX 50 500 50 50 500 50 12-10 12-10 12-10 12-10 12-10 12-10 .250 .250 .250 .250 .250 .250 #6 #6 #8 #10 #10 1 ⁄ 4" 8 8 8 8 8 8 1.07 1.07 1.10 1.10 1.10 1.22 .31 .31 .37 .37 .37 .50 .27 .27 .27 .27 .27 .32 .91 .91 .91 .91 .91 .96 Cat. No. Stock thickness same as ring terminal of same size. Dimensions U.L. Listed E9809 U.S. Pat. 3,590,387 Installing tools: ERG-2001, ERG-2003, WT145C, WT2000, WT112M Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) Heat Shrinkable Locking Fork Terminals— Expanded Insulation Support Cat. No. Pkg. Qty. ® ® Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 Dimensions A B RAS18-6FLX RAS18-8FLX RAS18-10FLX 100 100 100 22-18 22-18 22-18 .170 .170 .170 #6 #8 #10 5 5 5 1.350 1.350 1.350 .25 .29 .29 RBS14-6FLX RBS14-8FLX RBS14-10FLX 100 100 100 16-14 16-14 16-14 .200 .200 .200 #6 #8 #10 6 6 6 1.350 1.350 1.350 .25 .29 .29 RCS10-6FLX RCS10-8FLX RCS10-10FLX RCS10-14FLX 50 50 50 50 12-10 12-10 12-10 12-10 .250 .250 .250 .250 #6 #8 #10 1 ⁄ 4" 8 8 8 8 1.350 1.350 1.350 1.350 .31 .37 .37 .49 U.L. Listed E9809 Installing tool: WT1255 Note: Heat Shrinkable terminals not available on Mylar Tape. 100 Telecom 1-800-685-9452 Locking Fork Terminals ® Non-Insulated Locking Fork Pkg. Qty. Wire Range Bolt Hole Wt./Lbs. Per 1000 A B C A18-6FL A221 A18-8FL A224 A18-10FL A225 100 1000 100 1000 100 1000 22-16 22-16 22-16 22-16 22-16 22-16 #6 #6 #8 #8 #10 #10 4 3⁄ 4 4 3⁄ 4 3 4⁄ 4 3 4⁄ 4 3 4⁄ 4 3 4⁄ 4 .75 .75 .75 .75 .75 .75 .25 .25 .29 .29 .29 .29 .27 .27 .27 .27 .27 .27 .59 .59 .59 .59 .59 .59 B14-6FL B220 B14-8FL B223 B14-10FL B225 100 1000 100 1000 100 1000 18-14 18-14 18-14 18-14 18-14 18-14 #6 #6 #8 #8 #10 #10 4 3⁄ 4 4 3⁄ 4 3 4⁄ 4 3 4⁄ 4 3 4⁄ 4 3 4⁄ 4 .75 .75 .75 .75 .75 .75 .25 .25 .29 .29 .29 .29 .27 .27 .27 .27 .27 .27 .59 .59 .59 .59 .59 .59 C10-6FL C220 C10-8FL C221 C10-10FL C222-TB C10-14FL 50 500 50 500 50 500 50 12-10 12-10 12-10 12-10 12-10 12-10 12-10 #6 #6 #8 #8 #10 #10 1 ⁄ 4" 7 3⁄ 4 7 3⁄ 4 3 7⁄ 4 3 7⁄ 4 3 7⁄ 4 3 7⁄ 4 3 7⁄ 4 .85 .85 .85 .85 .85 .85 .85 .31 .31 .37 .37 .37 .37 .49 .27 .27 .27 .27 .27 .27 .27 .66 .66 .66 .66 .66 .66 .66 Cat. No. Stock thickness same as ring terminal of same size. ® Dimensions M U.L. Listed E9809 U.S. Pat. 3,590,387 Installing tools: WT110M, WT111M, WT112M, WT2000, ERG-2002, WT1300, WT3155A (B&C) Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and application dies). Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) Telecom 1-800-685-9452 101 Heat Shrinkable Terminal, Splices, Disconnects Heat Shrinkable These ring terminals, butt splices and disconnects are self-insulated with heat shrinkable nylon and internally coated sealant. Upon completed installation, a fully sealed connection is achieved to protect the joint against the degrading effects of galvanic action, corrosion, and environmen® ® Heat Shrinkable-Ring Terminals—Expanded Insulation Support Cat. No. Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 RAS18-6X RAS18-8X RAS18-10X 100 100 100 22-18 22-18 22-18 .170 .170 .170 #6 #8 #10 2 3 2 RBS14-6X RBS14-8X RBS14-10X 100 100 100 16-14 16-14 16-14 .200 .200 .200 #6 #8 #10 3 3 3 RCS10-6X RCS10-8X RCS10-10X RCS10-14X 50 50 50 50 12-10 12-10 12-10 12-10 .250 .250 .250 .250 #6 #8 #10 1 4" ⁄ 3 5 5 6 Installing tool: WT1255 See previous pages for dimensional information. Heat Shrinkable-Locking Fork Terminals— Expanded Insulation Support ® ® Cat. No. Pkg. Qty. Wire Range Max. Ins. Bolt Hole Wt./Lbs. Per 1000 RAS18-6FLX RAS18-8FLX RAS18-10FLX 100 100 100 22-18 22-18 22-18 .170 .170 .170 #6 #8 #10 5 5 5 RBS14-6FLX RBS14-8FLX RBS14-10FLX 100 100 100 16-14 16-14 16-14 .200 .200 .200 #6 #8 #10 6 6 6 RCS10-6FLX RCS10-8FLX RCS10-10FLX RCS10-14FLX 50 50 50 50 12-10 12-10 12-10 12-10 .250 .250 .250 .250 #6 #8 #10 1 ⁄ 4" 8 8 8 8 Installing tool: WT1255 Note: Not available on Mylar Tape. 102 Telecom 1-800-685-9452