AC 200 Series New Product 200 Watt Single Output U Frame AC-DC Modules with PFC BAUART .. GEPRUFT .. TYPE APPROVED FEATURES SPECIFICATIONS 1.5” Low Profile, 4”X6” Footprint Universal Input : 90 ~ 264Vac Active PFC Meets EN61000-3-2 EMI Meets CISPR/FCC Class B High Efficiency at 80% Typical Current Share Remote Voltage Sense AC OK Signal (Logic High) DC OK Signal (Logic High) PS ON/OFF Remote Control (Inhibit PSU by adding Logic High) NOTE 1: Optional function can be added when ordering: Top Cover with Fan (when forced air is needed) 2: Add a 0.1uF ceramic capacitor and a 47uF E.L. capacitor to output for Ripple & Noise measuring @20MHz BW. 3: Voltage accuracy is set at 60% rated load and 25℃ Ta. 4: Line regulation is measured from High Line to Low Line with rated load. 5: Load regulation is measured at 60%±40% rated load. 6: Dimensions tolerance : +/- 1mm. 7: Connectors: CN1(AC Input) : Molex 5273-05A or equivalent CN2(DC Output) : Molex 38700-7504 or equivalent CN6(Signals) : Molex 70247-10 or equivalent CN3,CN4,CN5(FAN) : Molex 5045-02A or equivalent Input Characteristics AC Input Voltage Frequency Inrush Current EMI Isolation Leakage Current Output Characteristics Total Rated Output Power Current Share Remote Voltage Sense Hold-up Time Over Voltage Protection Over Temperature Protection Short Circuit Protection Environmental Characteristics Operating Temperature Output Storage Temperature Mechanical Outline 90 ~ 264Vac 47 to 63Hz 60A Max. CISPR/FCC Class B Input to output = 4,242Vdc 3.5mA max. 200W (with 30CFM air flow or optional fan) Single wire current sharing Compensates for wire voltage drop 16mS typ. Recycle AC input to restart Auto Recovery Auto Recovery 0 ~ 70 degrees C 50~70 C with 2.5%/ degrees C derating PSU will be in thermal protection for exceeding the rated power output or the operating temperature -20 ~ 85 C Standard U Frame 150mmx100mmx38.1mm ( 5.91”*3.94”*1.5”) With Optional Fan 150mmx101.6mmx58.5mm ( 5.91”*4”*2.3”) Output Current (A) Ripple Voltage Line Load Model Voltage Rated Min. & Noise Accuracy Reg. Reg. AC200-033 +3.3V 40.0 0 1% ±1% ±1% ±1% AC200-050 +5.0V 40.0 0 1% ±1% ±1% ±1% AC200-120 +12V 16.7 0 1% ±1% ±1% ±1% AC200-150 +15V 13.4 0 1% ±1% ±1% ±1% AC200-180 +18V 11.2 0 1% ±1% ±1% ±1% AC200-240 +24V 8.4 0 1% ±1% ±1% ±1% AC200-280 +28V 7.2 0 1% ±1% ±1% ±1% AC200-300 +30V 6.7 0 1% ±1% ±1% ±1% AC200-360 +36V 5.6 0 1% ±1% ±1% ±1% AC200-480 +48V 4.2 0 1% ±1% ±1% ±1% Typical @25℃, 230Vac and 60% rated load, unless otherwise specified. AC 200 Series New Product 200 Watt Single Output U Frame AC-DC Modules with PFC DRAWINGS: (Preliminary) CN1 Fig.1. Mechanical Outline of AC200 Unit: inch (mm) Fig.2. Mechanical Outline of AC200-F (With Optiona1 Fan) Unit: inch (mm) PIN CONNECTION: CN6(Signals) CN1 (AC Input) PIN NO. ASSIGNMENT 1 Earth Ground 2 PIN10: NC PIN9: NC PIN8: NC PIN7: +V CSW PIN6: +V GS PIN5: +V VS PIN4: PS ON/OFF PIN3: AC OK PIN2: DC OK PIN1: GND NC 3 Neutral 4 NC 5 Line Note: VS means Remote Sense ”+” GS means Remote Sense “Return” (DC Output, T.B.) PIN NO. ASSIGNMENT 1 +V 2 +V 3 PWR GND 4 PWR GND CN3,CN4,CN5 (FAN Output) PIN NO. ASSIGNMENT 1 +12V(FAN) 2 GND(FAN) Rated Load (W CN2 200 175 150 125 100 75 50 25 0 With 30CFM Forced Air Convection Cool 0 10 20 30 40 50 60 70 80 Ambient Temperature (Deg.C) Fig.3. Output Derating Curve 2006/11/06 Ver. 19.0