AD ADISEVAL

iSensor™ PC Evaluation System
ADISEVAL
Preliminary Technical Data
GENERAL DESCRIPTION
2.
Using Figure 2 as a guide, install the appropriate
ADIS16XXX/PCBZ evaluation board on the Parallel
Interface Board. Four 2mm mounting holes are provided
for secure mechanical attachment and the 2 12-pin ribbon
cables are for the necessary electrical connections. These
cables are already installed on J3 and J4 of the Parallel
Interface Board and need to be connected to J1 and J2 of
the ADIS16XXX/PCBZ. Make sure that these cables are
seated correctly on each header. Misalignment can result
in damage to the sensor.
3.
Hook up the system to a PC using the parallel cable
provided.
4.
Place the iSensor™ CD into the PC’s CD drive and review
the ReadMeFirst.PDF file. Then install the software per
the instructions in this file.
The ADIS/EVAL is a PC-based evaluation system for all of the
SPI-output iSensor™ products. It is designed to work with
each product’s evaluation board and comes with a Parallel
Interface Board, parallel interface cable, 2 12-pin ribbon cables
for evaluation board (ADIS16XXX/PCBZ) attachment, and the
iSensor™ CD. The iSensor™ CD contains the iSensor
Evaluation Software, along with all of the documentation for
each iSensor product.
GETTING STARTED
Getting started with this system requires four simple steps.
1.
Connect J2 of the Parallel Interface Board (see Figure 1) to
the appropriate power supply, using Table 1. For simplicity,
Pins 1 and 4 can be tied together and Pins 2 and 3 can be
tied together. Set the voltage on the power supply per
Table 2.
The iSensor™ Evaluation Software installation will provide
options for evaluating a number of products. Using the
Windows Start button, select Programs, then select Analog
Devices iSensor™, then select the product that is being
evaluated. The first time the software is started, the interface
will need to be set up per the ReadMeFirst.PDF file.
Table 1 – Power Supply Hook-up – J2
Pin Number
Function
1
Digital I/O Power Supply
2
Common
3
Common
4
Sensor Power Supply
The software contains help files that describe each function of
the software. The right button on the mouse has the ability to
speed up changes when the Pointer is placed over titles, graph
axes and waveform data.
NOTE: No reverse polarity protection provided.
Table 2- Power Supply Voltages
Evaluation Board
SOFTWARE OPERATION
Power Supply Voltage
See Figure 4 (ADIS16003, ADIS16006), Figure 5 (ADIS16080,
ADIS16100), Figure 6 (ADIS16201), Figure 7 (ADIS16203), and
Figure 8 (ADIS16250) for basic software assistance.
ADIS16003/PCBZ
+3.0 to +5.25V
ADIS16006/PCBZ
+3.0 to +5.25V
ADIS16080/PCBZ
+4.75 to +5.25V
ADIS16100/PCB
+4.75 to +5.25V
ORDERING GUIDE
ADIS16201/PCBZ
+3.0 to +3.6V
Model
Package Description
ADIS16203/PCBZ
+3.0 to +3.6V
ADISEVAL
iSensor™ PC Evaluation System
ADIS16250/PCBZ
+4.75 to +5.25V
Rev. Pr.A,
8/10/06
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.326.8703
© 2006 Analog Devices, Inc. All rights reserved.
ADISEVAL
Preliminary Technical Data
Pin 1
Figure 1 – iSensor™ PC Interface Board Layout
Rev. PrA | Page 2 of 9
Preliminary Technical Data
ADISEVAL
12-pin
ribbon
cables
are
installed
here
Figure 2 – iSensor™ PC Interface Board with ADIS16201/PCBZ installed
Rev. PrA | Page 3 of 9
ADISEVAL
Preliminary Technical Data
VCC
VDD
J2
1725672
DNI
DNI
DNI
DNI
DNI
DNI
E10
E9
J1
E12
E11
E1
E2
E3
E4
E5
E6
E7
E8
E13
Figure 3 – iSensor™PC Evaluation Board Schematic
Rev. PrA | Page 4 of 9
Preliminary Technical Data
ADISEVAL
3
4
2
1
5
FIGURE FLAG NOTES:
1.
Set the Device type to ADIS16003 or ADIS16006. Set the Interface to parallel and set the port address per ReadMeFirst.PDF
2.
Set the axis being tested. Test function exercises a self-test during a single sweep on the screen.
3.
Plot and log data to files.
4.
Set up data logging parameters.
5.
Right click over Y-Axis to adjust scale and offset of the plot.
Figure 4. ADIS16003 and ADIS16006 Evaluation Software
Rev. PrA | Page 5 of 9
ADISEVAL
Preliminary Technical Data
3
4
2
1
5
FIGURE FLAG NOTES:
1.
Set the Device type to ADIS16080 or ADIS16100. Set the Interface to parallel and set the port address per ReadMeFirst.PDF
2.
Set the output channel being tested. Test function exercises a self-test during a single sweep on the screen.
3.
Plot and log data to files.
4.
Set up data logging parameters.
5.
Right click over Y-Axis to adjust scale and offset of the plot.
Figure 5. ADIS16080 and ADIS16100 Evaluation Software
Rev. PrA | Page 6 of 9
Preliminary Technical Data
ADISEVAL
1
4
2
3
FIGURE FLAG NOTES:
1.
Perform a single read of the ADIS16201’s output data
2.
Start and stop continuous reading of the ADIS16201’s output data. Set the acquisition loop delay time. This provides rough
control over sample times. Please note that this data will not have a high degree of coherence.
3.
Select the file data logging option.
4.
Configure the ADIS16201’s internal sample rate and filter response.
Figure 6. ADIS16201 Evaluation Software
Rev. PrA | Page 7 of 9
ADISEVAL
Preliminary Technical Data
1
5
4
2
6
3
FIGURE FLAG NOTES:
1.
Perform a single read of the ADIS16203’s output data
2.
Start and stop continuous reading of the ADIS16203’s output data. Set the acquisition loop delay time. This provides rough
control over sample times. Please note that this data will not have a high degree of coherence.
3.
Select the file data logging option.
4.
Configure the ADIS16203’s internal sample rate and filter response.
5.
Graphical orientation. Note that for incline angle - 0°, the corner dot would be in the lower, left hand corner.
6.
Alarm monitoring. Note that these turn red on alarm condition. They maintain their status until the Reset button is pressed,
even if the error condition has cleared.
Figure 7. ADIS16203 Evaluation Software
Rev. PrA | Page 8 of 9
Preliminary Technical Data
ADISEVAL
6
PR06335-0-8/06(PrA)
5
2
4
1
3
FIGURE FLAG NOTES:
1.
Perform a single read of the ADIS16250’s output data
2.
Start and stop continuous reading of the ADIS16250’s output data. Set the acquisition loop delay time. This provides rough
control over sample times. Please note that this data will not have a high degree of coherence.
3.
Select the file data logging option.
4.
Configure the ADIS16201’s internal sample rate and filter response.
5.
Set the measurement range from the three options available in the ADIS16250.
6.
Exercise the user calibration functions.
Figure 8. ADIS16250 Evaluation Software
Rev. PrA | Page 9 of 9