FUNCTIONAL BLOCK DIAGRAMS isoPower integrated, isolated dc-to-dc converter Qualified for automotive applications Regulated 5 V or 3.3 V output Up to 500 mW output power Quad dc-to-25 Mbps (NRZ) signal isolation channels 16-lead SOIC package with 7.6 mm creepage High temperature operation: 105°C High common-mode transient immunity: >25 kV/µs Safety and regulatory approvals UL recognition: 2500 V rms for 1 minute per UL 1577 CSA Component Acceptance Notice #5A VDE certificate of conformity DIN EN 69747-5-2 (VDE 0884 Teil 2):2003-1 VIORM = 565 V peak OSC VDD1 1 RECT REG VIA 3 VIB/VOB 4 VIC/VOC 5 16 VISO 15 GNDISO GND1 2 14 VOA 4 CHANNEL iCOUPLER CORE ADuM5401W/ADuM5402W/ ADuM5403W 13 VOB/VIB 12 VOC/VIC 11 VID VOD 6 10 VSEL RCOUT 7 GND1 8 9 GNDISO 08758-001 FEATURES Figure 1. ADuM5401W/ADuM5402W/ADuM5403W Block Diagram VIA VIB APPLICATIONS VIC VOD Hybrid electric battery management 3 14 ADuM5401W 4 13 5 12 6 11 VOA VOB VOC VID 08758-002 Data Sheet Quad-Channel Isolators with Integrated DC-to-DC Converter ADuM5401W/ADuM5402W/ADuM5403W Figure 2. ADuM5401W GENERAL DESCRIPTION isoPower uses high frequency switching elements to transfer power through its transformer. Special care must be taken during printed circuit board (PCB) layout to meet emissions standards. See the AN-0971 Application Note for board layout recommendations. 1 VOC VOD 3 14 ADuM5402W 4 13 5 12 6 11 VOA VOB VIC VID Figure 3. ADuM5402W VIA VOB VOC VOD 3 14 ADuM5403W 4 13 5 12 6 11 VOA VIB VIC VID 08758-004 The ADuM5401W-1/ADuM5402W-1/ADuM5403W-1 versions of the isolators provide an upgraded voltage reference to ensure proper startup under all load conditions (see the Ordering Guide for more information). VIA VIB 08758-003 The ADuM5401W/ADuM5402W/ADuM5403W1 devices are quad-channel digital isolators with isoPower®, an integrated, isolated dc-to-dc converter. Based on the Analog Devices, Inc., iCoupler® technology, the dc-to-dc converter provides up to 500 mW of regulated, isolated power at 5.0 V (see Table 1). These devices eliminate the need for a separate, isolated dc-todc converter in low power, isolated designs. The iCoupler chip scale transformer technology is used to isolate the logic signals and for the magnetic components of the dc-to-dc converter. The result is a small form factor, total isolation solution. Figure 4. ADuM5403W Table 1. Power Levels Input Voltage (V) 5.0 5.0 3.3 Output Voltage (V) 5.0 3.3 3.3 Output Power (mW) 500 330 200 Protected by U.S. Patents 5,952,849; 6,873,065; 6,903,578; and 7,075,329. Other patents are pending. Rev. D Document Feedback Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 ©2010–2013 Analog Devices, Inc. All rights reserved. Technical Support www.analog.com ADuM5401W/ADuM5402W/ADuM5403W Data Sheet TABLE OF CONTENTS Features .............................................................................................. 1 Truth Table .................................................................................. 14 Applications ....................................................................................... 1 Typical Performance Characteristics ........................................... 15 General Description ......................................................................... 1 Terminology .................................................................................... 18 Functional Block Diagrams ............................................................. 1 Applications Information .............................................................. 19 Revision History ............................................................................... 2 Theory of Operation .................................................................. 19 Specifications..................................................................................... 3 PCB Layout ................................................................................. 19 Electrical Characteristics—5 V Primary Input Supply/5 V Secondary Isolated Supply .......................................................... 3 Thermal Analysis ....................................................................... 19 Electrical Characteristics—3.3 V Primary Input Supply/3.3 V Secondary Isolated Supply .......................................................... 5 Start-Up Behavior....................................................................... 20 Electrical Characteristics—5 V Primary Input Supply/3.3 V Secondary Isolated Supply .......................................................... 7 DC Correctness and Magnetic Field Immunity ..................... 20 Propagation Delay Related Parameters ................................... 20 EMI Considerations ................................................................... 20 Package Characteristics ............................................................... 9 Power Consumption .................................................................. 21 Regulatory Approvals................................................................... 9 Power Considerations ................................................................ 22 Insulation and Safety-Related Specifications ............................ 9 Insulation Lifetime ..................................................................... 22 VISO Start-Up Issues .................................................................... 23 DIN EN 69747-5-2 (VDE 0884 Teil 2) Insulation Characteristics ............................................................................ 10 Outline Dimensions ....................................................................... 24 Recommended Operating Conditions .................................... 10 Ordering Guide .......................................................................... 24 Absolute Maximum Ratings.......................................................... 11 Automotive Products ................................................................. 24 ESD Caution ................................................................................ 11 Pin Configurations and Function Descriptions ......................... 12 REVISION HISTORY 4/13—Rev. C to Rev. D Added Figure 17 and Figure 18; Renumbered Sequentially ..... 16 Added Start-Up Behavior Section ................................................ 20 Change to DC Correctness and Magnetic Field Immunity Section .............................................................................................. 20 Changes to Ordering Guide .......................................................... 24 11/12—Rev. B to Rev. C Changes to Ordering Guide .......................................................... 23 6/12—Rev. A to Rev. B Created Hyperlink for Safety and Regulatory Approvals Entry in Features Section................................................................. 1 Added Table 1; Renumbered Sequentially .................................... 1 Changes to Table 2, Table 3, and Table 4 ....................................... 3 Changes to Endnote 3 in Table 5 .................................................... 4 Change to Table 6 ............................................................................. 5 Changes to Table 9 ............................................................................ 6 Change to Table 10 ........................................................................... 7 Changes to Table 13 .......................................................................... 8 Change to Table 16 ........................................................................... 9 Change to Table 18 ......................................................................... 10 Changes to Table 21 ........................................................................ 12 Changes to Table 22 ........................................................................ 13 Changes to Table 23 and Table 24 ................................................ 14 Changes to Theory of Operation Section.................................... 18 Changes to EMI Considerations Section .................................... 19 4/12—Rev. 0 to Rev. A Changes to General Description and Features Sections ..............1 Changed DIN V VDE 0884-10 (VDE V 0884-10):2006-12 to DIN EN 69747-5-2 (VDE 0884 Teil 2):2003-1 Throughout ........1 Added Electrical Characteristics—3.3 V Primary Input Supply/3.3 V Secondary Isolated Supply Section ..........................5 Added Table 5, Table 6, and Table 7; Renumbered Sequentially ........................................................................................5 Added Table 8 ....................................................................................6 Added Electrical Characteristics—5 V Primary Input Supply/ 3.3 V Secondary Isolated Supply Section .......................................7 Added Table 9, Table 10, and Table 11............................................7 Added Table 12 ..................................................................................8 Changes to Table 14 and Table 15 ...................................................9 Changes to Table 16 ....................................................................... 10 Changes to Typical Performance Characteristics Section ........ 16 Changes to VISO Start-Up Issues Section ..................................... 23 Changes to Ordering Guide .......................................................... 24 Added Automotive Products Section .......................................... 24 1/10—Revision 0: Initial Version Rev. D | Page 2 of 24 Data Sheet ADuM5401W/ADuM5402W/ADuM5403W SPECIFICATIONS ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/5 V SECONDARY ISOLATED SUPPLY Typical specifications are at TA = 25°C, VDD1 = VSEL = VISO = 5 V. Minimum/maximum specifications apply over the entire recommended operation range, which is 4.5 V ≤ VDD1, VSEL, VISO ≤ 5.5 V, and −40°C ≤ TA ≤ +105°C, unless otherwise noted. Switching specifications are tested with CL = 15 pF and CMOS signal levels, unless otherwise noted. Table 2. DC-to-DC Converter Static Specifications Parameter DC-TO-DC CONVERTER SUPPLY Setpoint Line Regulation Load Regulation Output Ripple Output Noise Switching Frequency PWM Frequency Output Supply Current Efficiency at IISO (MAX) IDD1, No VISO Load IDD1, Full VISO Load Symbol Min Typ Max Unit Test Conditions/Comments VISO VISO (LINE) VISO (LOAD) VISO (RIP) VISO (NOISE) fOSC fPWM IISO (MAX) 4.7 5.0 1 1 75 200 180 625 5.4 V mV/V % mV p-p mV p-p MHz kHz mA % mA mA IISO = 0 mA IISO = 50 mA, VDD1 = 4.5 V to 5.5 V IISO = 10 mA to 90 mA 20 MHz bandwidth, CBO = 0.1 µF||10 µF, IISO = 90 mA CBO = 0.1 µF||10 µF, IISO = 90 mA Unit Test Conditions/Comments 68 71 75 mA mA mA No VISO load No VISO load No VISO load 87 85 83 mA mA mA 5 100 34 20 290 IDD1 (Q) IDD1 (MAX) 35 VISO > 4.5 V IISO = 100 mA Table 3. DC-to-DC Converter Dynamic Specifications Parameter SUPPLY CURRENT Input ADuM5401W ADuM5402W ADuM5403W Available to Load ADuM5401W ADuM5402W ADuM5403W Symbol 25 Mbps—C Grade Min Typ Max IDD1 IISO (LOAD) Table 4. Switching Specifications Parameter SWITCHING SPECIFICATIONS Data Rate Propagation Delay Pulse Width Distortion Change vs. Temperature Pulse Width Propagation Delay Skew Channel Matching Codirectional 1 Opposing Directional 2 Symbol Min tPHL, tPLH PWD Typ Max Unit Test Conditions/Comments 45 25 60 6 Within PWD limit 50% input to 50% output |tPLH − tPHL| 15 Mbps ns ns ps/°C ns ns 6 15 ns ns 5 PW tPSK tPSKCD tPSKOD 40 Within PWD limit Between any two units Codirectional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of the isolation barrier. 2 Opposing directional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on opposing sides of the isolation barrier. 1 Rev. D | Page 3 of 24 ADuM5401W/ADuM5402W/ADuM5403W Data Sheet Table 5. Input and Output Characteristics Parameter DC SPECIFICATIONS Logic High Input Threshold 1 Logic Low Input Threshold1 Symbol Min VIH VIL 0.7 × VISO or 0.7 × VDD1 Logic High Output Voltages 2 VOH VDD1 − 0.3 or VISO − 0.3 VDD1 − 0.5 or VISO − 0.5 Logic Low Output Voltages2 VOL Undervoltage Lockout Positive Going Threshold Negative Going Threshold Hysteresis Input Currents Per Channel AC SPECIFICATIONS Output Rise/Fall Time Common-Mode Transient Immunity 3 Refresh Rate Typ Max 0.3 × VISO or 0.3 × VDD1 5.0 4.8 0.0 0.2 Unit V V 0.1 0.4 V V V V +20 V V V µA UVLO VUV+ VUV− VUVH II −20 2.7 2.4 0.3 +0.01 tR/tF |CM| 25 2.5 35 ns kV/µs 1.0 Mbps fr Test Conditions/Comments IOx = −20 µA, VIx = VIxH IOx = −4 mA, VIx = VIxH IOx = 20 µA, VIx = VIxL IOx = 4 mA, VIx = VIxL VDD1, VISO supplies 0 V ≤ VIx ≤ VDD1 or VISO 10% to 90% VIx = VDD1 or VISO, VCM = 1000 V, transient magnitude = 800 V VSEL is a nonstandard input that has a logic threshold of approximately 0.9 V. RCOUT is a nonstandard output intended to interface with other isoPower parts. It is not recommended for standard digital loads. 3 |CM| is the maximum common-mode voltage slew rate that can be sustained while maintaining VO > 0.7 × VDD1 or 0.7 × VISO for a high output or VO < 0.3 × VDD1 or 0.3 × VISO for a low output. The common-mode voltage slew rates apply to both rising and falling common-mode voltage edges. 1 2 Rev. D | Page 4 of 24 Data Sheet ADuM5401W/ADuM5402W/ADuM5403W ELECTRICAL CHARACTERISTICS—3.3 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY Typical specifications are at TA = 25°C, VDD1 = VISO = 3.3 V, VSEL = GNDISO. Minimum/maximum specifications apply over the entire recommended operation range, which is 3.0 V ≤ VDD1, VSEL, VISO ≤ 3.6 V, and −40°C ≤ TA ≤ +105°C, unless otherwise noted. Switching specifications are tested with CL = 15 pF and CMOS signal levels, unless otherwise noted. Table 6. DC-to-DC Converter Static Specifications Parameter DC-TO-DC CONVERTER SUPPLY Setpoint Line Regulation Load Regulation Output Ripple Output Noise Switching Frequency PWM Frequency Output Supply Current Efficiency at IISO (MAX) IDD1, No VISO Load IDD1, Full VISO Load Symbol Min Typ Max Unit Test Conditions/Comments VISO VISO (LINE) VISO (LOAD) VISO (RIP) VISO (NOISE) fOSC fPWM IISO (MAX) 3.0 3.3 1 1 50 130 180 625 3.6 V mV/V % mV p-p mV p-p MHz kHz mA % mA mA IISO = 0 mA IISO = 30 mA, VDD1 = 3.0 V to 3.6 V IISO = 6 mA to 54 mA 20 MHz bandwidth, CBO = 0.1 µF||10 µF, IISO = 54 mA CBO = 0.1 µF||10 µF, IISO = 54 mA Unit Test Conditions/Comments 44 46 47 mA mA mA No VISO load No VISO load No VISO load 52 51 49 mA mA mA 5 60 33 14 175 IDD1 (Q) IDD1 (MAX) 22 VISO > 3 V IISO = 60 mA Table 7. DC-to-DC Converter Dynamic Specifications Parameter SUPPLY CURRENT Input ADuM5401W ADuM5402W ADuM5403W Available to Load ADuM5401W ADuM5402W ADuM5403W Symbol 25 Mbps—C Grade Min Typ Max IDD1 IISO (LOAD) Table 8. Switching Specifications Parameter SWITCHING SPECIFICATIONS Data Rate Propagation Delay Pulse Width Distortion Change vs. Temperature Pulse Width Propagation Delay Skew Channel Matching Codirectional 1 Opposing Directional 2 Symbol Min tPHL, tPLH PWD Typ Max Unit Test Conditions/Comments 45 25 60 6 Within PWD limit 50% input to 50% output |tPLH − tPHL| 45 Mbps ns ns ps/°C ns ns 6 15 ns ns 5 PW tPSK tPSKCD tPSKOD 40 Within PWD limit Between any two units Codirectional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of the isolation barrier. 2 Opposing directional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on opposing sides of the isolation barrier. 1 Rev. D | Page 5 of 24 ADuM5401W/ADuM5402W/ADuM5403W Data Sheet Table 9. Input and Output Characteristics Parameter DC SPECIFICATIONS Logic High Input Threshold 1 Logic Low Input Threshold1 Symbol Min VIH VIL 0.7 × VISO or 0.7 × VDD1 Logic High Output Voltages 2 VOH VDD1 − 0.3 or VISO − 0.3 VDD1 − 0.5 or VISO − 0.5 Logic Low Output Voltages2 VOL Undervoltage Lockout Positive Going Threshold Negative Going Threshold Hysteresis Input Currents per Channel AC SPECIFICATIONS Output Rise/Fall Time Common-Mode Transient Immunity 3 Refresh Rate Typ Max 0.3 × VISO or 0.3 × VDD1 3.3 3.1 0.0 0.0 Unit V V 0.1 0.4 V V V V +10 V V V µA UVLO VUV+ VUV− VUVH II −10 2.7 2.4 0.3 +0.01 tR/tF |CM| 25 2.5 35 ns kV/µs 1.0 Mbps fr Test Conditions/Comments IOx = −20 µA, VIx = VIxH IOx = −4 mA, VIx = VIxH IOx = 20 µA, VIx = VIxL IOx = 4 mA, VIx = VIxL VDD1, VISO supplies 0 V ≤ VIx ≤ VDD1 or VISO 10% to 90% VIx = VDD1 or VISO, VCM = 1000 V, transient magnitude = 800 V VSEL is a nonstandard input that has a logic threshold of approximately 0.9 V. RCOUT is a nonstandard output intended to interface with other isoPower parts. It is not recommended for standard digital loads. 3 |CM| is the maximum common-mode voltage slew rate that can be sustained while maintaining VO > 0.7 × VDD1 or 0.7 × VISO for a high output or VO < 0.3 × VDD1 or 0.3 × VISO for a low output. The common-mode voltage slew rates apply to both rising and falling common-mode voltage edges. 1 2 Rev. D | Page 6 of 24 Data Sheet ADuM5401W/ADuM5402W/ADuM5403W ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY Typical specifications are at TA = 25°C, VDD1 = 5.0 V, VISO = 3.3 V, VSEL = GNDISO. Minimum/maximum specifications apply over the entire recommended operation range, which is 4.5 V ≤ VDD1 ≤ 5.5 V, 3.0 V ≤ VISO ≤ 3.6 V, and −40°C ≤ TA ≤ +105°C, unless otherwise noted. Switching specifications are tested with CL = 15 pF and CMOS signal levels, unless otherwise noted. Table 10. DC-to-DC Converter Static Specifications Parameter DC-TO-DC CONVERTER SUPPLY Setpoint Line Regulation Load Regulation Output Ripple Output Noise Switching Frequency PWM Frequency Output Supply Current Efficiency at IISO (MAX) IDD1, No VISO Load IDD1, Full VISO Load Symbol Min Typ Max Unit Test Conditions/Comments VISO VISO (LINE) VISO (LOAD) VISO (RIP) 3.0 3.3 1 1 50 3.6 V mV/V % mV p-p IISO = 0 mA IISO = 50 mA, VDD1 = 3.0 V to 3.6 V IISO = 6 mA to 54 mA 20 MHz bandwidth, CBO = 0.1 µF||10 µF, IISO = 90 mA CBO = 0.1 µF||10 µF, IISO = 90 mA VISO (NOISE) fOSC fPWM IISO (MAX) 5 130 180 625 100 30 14 230 IDD1 (Q) IDD1 (MAX) 22 mV p-p MHz kHz mA % mA mA VISO > 3 V IISO = 90 mA Table 11. DC-to-DC Converter Dynamic Specifications Parameter SUPPLY CURRENT Input ADuM5401W ADuM5402W ADuM5403W Available to Load ADuM5401W ADuM5402W ADuM5403W Symbol Min 25 Mbps—C Grade Typ Max Unit Test Conditions/Comments 44 45 46 mA mA mA No VISO load No VISO load No VISO load 92 91 89 mA mA mA IDD1 IISO (LOAD) Table 12. Switching Specifications Parameter SWITCHING SPECIFICATIONS Data Rate Propagation Delay Pulse Width Distortion Change vs. Temperature Pulse Width Propagation Delay Skew Channel Matching Codirectional 1 Opposing Directional 2 Symbol Min tPHL, tPLH PWD Typ Max Unit Test Conditions/Comments 45 25 60 6 Within PWD limit 50% input to 50% output |tPLH − tPHL| 15 Mbps ns ns ps/°C ns ns 6 15 ns ns 5 PW tPSK tPSKCD tPSKOD 40 Within PWD limit Between any two units Codirectional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of the isolation barrier. 2 Opposing directional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on opposing sides of the isolation barrier. 1 Rev. D | Page 7 of 24 ADuM5401W/ADuM5402W/ADuM5403W Data Sheet Table 13. Input and Output Characteristics Parameter DC SPECIFICATIONS Logic High Input Threshold 1 Symbol Min VIH 0.7 × VISO or 0.7 × VDD1 Logic Low Input Threshold1 VIL Logic High Output Voltages 2 VOH Logic Low Output Voltages2 Undervoltage Lockout Positive Going Threshold Negative Going Threshold Hysteresis Input Currents per Channel AC SPECIFICATIONS Output Rise/Fall Time Common-Mode Transient Immunity 3 Refresh Rate Typ Max VOL V VDD1 or VISO V IOx = −20 µA, VIx = VIxH VDD1 − 0.2 or VISO − 0.2 0.0 0.0 V IOx = −4 mA, VIx = VIxH 0.1 0.4 V V IOx = 20 µA, VIx = VIxL IOx = 4 mA, VIx = VIxL VDD1, VISO supplies +10 V V V µA UVLO VUV+ VUV− VUVH II −10 2.7 2.4 0.3 +0.01 tR/tF |CM| 25 2.5 35 ns kV/µs 1.0 Mbps fr Test Conditions/Comments V 0.3 × VISO or 0.3 × VDD1 VDD1 − 0.2 or VISO − 0.2 VDD1 − 0.5 or VISO − 0.5 Unit 0 V ≤ VIx ≤ VDD1 or VISO 10% to 90% VIx = VDD1 or VISO, VCM = 1000 V, transient magnitude = 800 V VSEL is a nonstandard input that has a logic threshold of approximately 0.9 V. RCOUT is a nonstandard output intended to interface with other isoPower parts. It is not recommended for standard digital loads. 3 |CM| is the maximum common-mode voltage slew rate that can be sustained while maintaining VO > 0.7 × VDD1 or 0.7 × VISO for a high output or VO < 0.3 × VDD1 or 0.3 × VISO for a low output. The common-mode voltage slew rates apply to both rising and falling common-mode voltage edges. 1 2 Rev. D | Page 8 of 24 Data Sheet ADuM5401W/ADuM5402W/ADuM5403W PACKAGE CHARACTERISTICS Table 14. Thermal and Isolation Characteristics Parameter Resistance (Input to Output) 1 Capacitance (Input to Output)1 Input Capacitance 2 IC Junction to Ambient Thermal Resistance Symbol RI-O CI-O CI θJA Min Typ 1012 2.2 4.0 45 Max Unit Ω pF pF °C/W Test Conditions/Comments f = 1 MHz Thermocouple located at center of package underside, test conducted on 4-layer board with thin traces 3 The device is considered a 2-terminal device; Pin 1 to Pin 8 are shorted together, and Pin 9 to Pin 16 are shorted together. Input capacitance is from any input data pin to ground. 3 See the Thermal Analysis section for thermal model definitions. 1 2 REGULATORY APPROVALS Table 15. UL 1 Recognized under 1577 component recognition program1 Single protection, 2500 V rms isolation voltage File E214100 CSA Approved under CSA Component Acceptance Notice #5A Basic insulation per CSA 60950-1-03 and IEC 60950-1, 400 V rms (566 V peak) maximum working voltage File 205078 VDE 2 Certified according to DIN EN 69747-5-2 (VDE 0884 Teil 2):2003-1 Reinforced insulation, 565 V peak File 2471900-4880-0001 In accordance with UL 1577, each ADuM5401W/ADuM5402W/ADuM5403W is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 10 µA). 2 In accordance with DIN EN 69747-5-2 (VDE 0884 Teil 2):2003-1, each ADuM5401W/ADuM5402W/ADuM5403W is proof tested by applying an insulation test voltage ≥ 1590 V peak for 1 second (partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates DIN EN 69747-5-2 (VDE 0884 Teil 2):2003-1 approval. 1 INSULATION AND SAFETY-RELATED SPECIFICATIONS Table 16. Critical Safety-Related Dimensions and Material Properties Parameter Rated Dielectric Insulation Voltage Minimum External Air Gap (Clearance) Symbol L(I01) Value 2500 >8.0 Unit V rms mm Minimum External Tracking (Creepage) L(I02) 7.6 mm Minimum Internal Gap (Internal Clearance) Tracking Resistance (Comparative Tracking Index) Isolation Group CTI 0.017 min >175 IIIa mm V Rev. D | Page 9 of 24 Test Conditions/Comments 1-minute duration Measured from input terminals to output terminals in the seating plane of the PCB, shortest distance through air Measured from input terminals to output terminals, shortest distance path along body Distance through insulation DIN IEC 112/VDE 0303, Part 1 Material group (DIN VDE 0110, 1/89, Table 1) ADuM5401W/ADuM5402W/ADuM5403W Data Sheet DIN EN 69747-5-2 (VDE 0884 TEIL 2) INSULATION CHARACTERISTICS These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by the protective circuits. The asterisk (*) marking on packages denotes DIN EN 69747-5-2 (VDE 0884 Teil 2):2003-1 approval. Table 17. VDE Characteristics Description Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 150 V rms For Rated Mains Voltage ≤ 300 V rms For Rated Mains Voltage ≤ 400 V rms Climatic Classification Pollution Degree per DIN VDE 0110, Table 1 Maximum Working Insulation Voltage Input-to-Output Test Voltage, Method b1 Conditions VIORM × 1.875 = VPR, 100% production test, tm = 1 sec, partial discharge < 5 pC Input-to-Output Test Voltage, Method a After Environmental Tests Subgroup 1 After Input and/or Safety Test Subgroup 2 and Subgroup 3 Highest Allowable Overvoltage Safety Limiting Values Symbol Characteristic Unit VIORM VPR I to IV I to III I to II 40/105/21 2 565 1059 V peak V peak 904 678 V peak V peak VTR 4000 V peak TS IS1 RS 150 555 >109 °C mA Ω VPR VIORM × 1.6 = VPR, tm = 60 sec, partial discharge < 5 pC VIORM × 1.2 = VPR, tm = 60 sec, partial discharge < 5 pC Transient overvoltage, tTR = 10 sec Maximum value allowed in the event of a failure (see Figure 5) Case Temperature Side 1 IDD1 Current Insulation Resistance at TS VIO = 500 V 500 400 300 200 100 0 08758-005 SAFE OPERATING VDD1 CURRENT (mA) 600 0 50 100 150 AMBIENT TEMPERATURE (°C) 200 Figure 5. Thermal Derating Curve, Dependence of Safety Limiting Values on Case Temperature, per DIN EN 60747-5-2 RECOMMENDED OPERATING CONDITIONS Table 18. Parameter Operating Temperature 1 Supply Voltages 2 1 2 Symbol TA VDD1 Min −40 3.0 Operation at 105°C requires reduction of the maximum load current, as specified in Table 19. Each voltage is relative to its respective ground. Rev. D | Page 10 of 24 Max +105 5.5 Unit °C V Data Sheet ADuM5401W/ADuM5402W/ADuM5403W ABSOLUTE MAXIMUM RATINGS Ambient temperature = 25°C, unless otherwise noted. Table 20. Maximum Continuous Working Voltage Supporting 50-Year Minimum Lifetime1 Table 19. Parameter Storage Temperature (TST) Ambient Operating Temperature Range (TA) Supply Voltages (VDD1, VISO)1 VISO Supply Current2 TA = −40°C to +85°C TA = −40°C to +105°C Input Voltage (VIA, VIB, VIC, VID)1, 3 Output Voltage (RCOUT, VOA, VOB, VOC, VOD)1, 3 Average Output Current Per Data Output Pin4 Maximum Cumulative AC HiPot Maximum Cumulative DC HiPot Common-Mode Transients5 Rating −55°C to +150°C −40°C to +105°C Parameter AC Voltage Bipolar Waveform Unit 424 V peak Basic Insulation 560 V peak Unipolar Waveform Basic Insulation 560 V peak Working voltage per IEC 60950-1 560 V peak Working voltage per IEC 60950-1 −0.5 V to +7.0 V 100 mA 60 mA −0.5 V to VDDI + 0.5 V −0.5 V to VDDO + 0.5 V DC Voltage Basic Insulation −10 mA to +10 mA 5 min at 2500 V rms 5 min at 3500 VDC −100 kV/µs to +100 kV/µs All voltages are relative to their respective grounds. VISO provides current for dc and dynamic loads on the VISO I/O channels. This current must be included when determining the total VISO supply current. For ambient temperatures from 85°C to 105°C, the maximum allowed current is reduced. 3 VDDI and VDDO refer to the supply voltages on the input and output sides of a given channel, respectively. See the PCB Layout section. 4 See Figure 5 for the maximum rated current values for various temperatures. 5 Refers to common-mode transients across the insulation barrier. Commonmode transients exceeding the absolute maximum ratings may cause latch-up or permanent damage. 1 1 Applicable Certification Max All certifications, 50-year operation Working voltage per IEC 60950-1 Refers to the continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more information. ESD CAUTION 2 Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Rev. D | Page 11 of 24 ADuM5401W/ADuM5402W/ADuM5403W Data Sheet PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS VDD1 1 16 VISO GND1 2 15 GNDISO VIA 3 14 VOA VIC 5 ADuM5401W 13 VOB TOP VIEW (Not to Scale) 12 VOC VOD 6 11 VID RCOUT 7 10 VSEL GND1 8 9 GNDISO 08758-006 VIB 4 Figure 6. ADuM5401W Pin Configuration Table 21. ADuM5401W Pin Function Descriptions Pin No. 1 2, 8 Mnemonic VDD1 GND1 3 4 5 6 7 VIA VIB VIC VOD RCOUT 9, 15 GNDISO 10 11 12 13 14 16 VSEL VID VOC VOB VOA VISO Description Primary Supply Voltage, 3.0 V to 5.5 V. Ground Reference for the Primary Side of the Isolator. Pin 2 and Pin 8 are internally connected to each other, and it is recommended that both pins be connected to a common ground. Logic Input A. Logic Input B. Logic Input C. Logic Output D. Regulation Control Output. This pin is connected to the RCIN pin of a slave isoPower device to allow the ADuM5401W to control the regulation of the slave device. Ground Reference for the Secondary Side of the Isolator. Pin 9 and Pin 15 are internally connected to each other, and it is recommended that both pins be connected to a common ground. Output Voltage Selection. When VSEL = VISO, the VISO setpoint is 5.0 V. When VSEL = GNDISO, the VISO setpoint is 3.3 V. Logic Input D. Logic Output C. Logic Output B. Logic Output A. Secondary Supply Voltage Output for External Loads: 3.3 V (VSEL = GNDISO) or 5.0 V (VSEL = VISO). Rev. D | Page 12 of 24 Data Sheet ADuM5401W/ADuM5402W/ADuM5403W VDD1 1 16 VISO GND1 2 15 GNDISO VIA 3 14 VOA VOC 5 ADuM5402W 13 VOB TOP VIEW (Not to Scale) 12 VIC VOD 6 11 VID RCOUT 7 10 VSEL GND1 8 9 GNDISO 08758-007 VIB 4 Figure 7. ADuM5402W Pin Configuration Table 22. ADuM5402W Pin Function Descriptions Pin No. 1 2, 8 Mnemonic VDD1 GND1 3 4 5 6 7 VIA VIB VOC VOD RCOUT 9, 15 GNDISO 10 11 12 13 14 16 VSEL VID VIC VOB VOA VISO Description Primary Supply Voltage, 3.0 V to 5.5 V. Ground Reference for the Primary Side of the Isolator. Pin 2 and Pin 8 are internally connected to each other, and it is recommended that both pins be connected to a common ground. Logic Input A. Logic Input B. Logic Output C. Logic Output D. Regulation Control Output. This pin is connected to the RCIN pin of a slave isoPower device to allow the ADuM5402W to control the regulation of the slave device. Ground Reference for the Secondary Side of the Isolator. Pin 9 and Pin 15 are internally connected to each other, and it is recommended that both pins be connected to a common ground. Output Voltage Selection. When VSEL = VISO, the VISO setpoint is 5.0 V. When VSEL = GNDISO, the VISO setpoint is 3.3 V. Logic Input D. Logic Input C. Logic Output B. Logic Output A. Secondary Supply Voltage Output for External Loads: 3.3 V (VSEL = GNDISO) or 5.0 V (VSEL = VISO). Rev. D | Page 13 of 24 ADuM5401W/ADuM5402W/ADuM5403W Data Sheet VDD1 1 16 VISO GND1 2 15 GNDISO VIA 3 14 VOA VOC 5 ADuM5403W 13 VIB TOP VIEW (Not to Scale) 12 VIC VOD 6 11 VID RCOUT 7 10 VSEL GND1 8 9 GNDISO 08758-008 VOB 4 Figure 8. ADuM5403W Pin Configuration Table 23. ADuM5403W Pin Function Descriptions Pin No. 1 2, 8 Mnemonic VDD1 GND1 3 4 5 6 7 VIA VOB VOC VOD RCOUT 9, 15 GNDISO 10 11 12 13 14 16 VSEL VID VIC VIB VOA VISO Description Primary Supply Voltage, 3.0 V to 5.5 V. Ground Reference for the Primary Side of the Isolator. Pin 2 and Pin 8 are internally connected to each other, and it is recommended that both pins be connected to a common ground. Logic Input A. Logic Output B. Logic Output C. Logic Output D. Regulation Control Output. This pin is connected to the RCIN pin of a slave isoPower device to allow the ADuM5403W to control the regulation of the slave device. Ground Reference for the Secondary Side of the Isolator. Pin 9 and Pin 15 are internally connected to each other, and it is recommended that both pins be connected to a common ground. Output Voltage Selection. When VSEL = VISO, the VISO setpoint is 5.0 V. When VSEL = GNDISO, the VISO setpoint is 3.3 V. Logic Input D. Logic Input C. Logic Input B. Logic Output A. Secondary Supply Voltage Output for External Loads: 3.3 V (VSEL = GNDISO) or 5.0 V (VSEL = VISO). TRUTH TABLE Table 24. Truth Table (Positive Logic) VSEL High Low Low High 1 RCOUT 1 PWM PWM PWM PWM VDD1 (V) 5 5 3.3 3.3 VISO (V) 5 3.3 3.3 5 Notes Master mode, normal operation Master mode, normal operation Master mode, normal operation This supply configuration is not recommended due to extremely poor efficiency PWM refers to the regulation control signal. This signal is derived from the secondary side regulator and can be used to control other isoPower devices. Rev. D | Page 14 of 24 Data Sheet ADuM5401W/ADuM5402W/ADuM5403W 4.0 40 4.0 35 3.5 30 3.0 3.0 2.5 2.5 2.0 2.0 1.5 1.5 25 20 15 1.0 1.0 10 0.02 0.04 0.06 0.08 OUTPUT CURRENT (A) 0.10 0.12 0.5 0.5 0 3.0 3.5 4.0 4.5 5.0 5.5 6.0 0 6.5 08758-012 0 IDD1 08758-009 3.3V INPUT/3.3V OUTPUT 5V INPUT/3.3V OUTPUT 5V INPUT/5V OUTPUT 5 0 3.5 POWER INPUT SUPPLY VOLTAGE (V) Figure 9. Typical Power Supply Efficiency at 5 V Input/5 V Output and 3.3 V Input/3.3 V Output Figure 12. Typical Short-Circuit Input Current and Power vs. VDD1 Supply Voltage OUTPUT VOLTAGE (500mV/DIV) 1.0 0.9 0.7 0.6 0.5 90% LOAD 10% LOAD 0.4 0.3 0.2 0 0 0.02 0.04 0.06 IISO (A) 0.08 0.10 0.12 (100µs/DIV) 08758-010 VDD1 = 5V, V ISO = 5V VDD1 = 5V, V ISO = 3.3V VDD1 = 3.3V, V ISO = 3.3V 08758-013 DYNAMIC LOAD POWER DISSIPATION (W) 0.8 0.1 Figure 10. Typical Total Power Dissipation vs. Isolated Output Supply Current in All Supported Power Configurations Figure 13. Typical VISO Transient Load Response, 5 V Output, 10% to 90% Load Step OUTPUT VOLTAGE (500mV/DIV) 0.12 0.08 0.04 0 3.3V INPUT/3.3V OUTPUT 5V INPUT/3.3V OUTPUT 5V INPUT/5V OUTPUT 0 0.05 0.10 0.15 0.20 INPUT CURRENT (A) 0.25 0.30 0.35 10% LOAD 90% LOAD 08758-014 DYNAMIC LOAD 0.06 08758-011 OUTPUT CURRENT (A) 0.10 0.02 POWER (W) INPUT CURRENT (A) EFFICIENCY (%) TYPICAL PERFORMANCE CHARACTERISTICS (100µs/DIV) Figure 14. Typical VISO Transient Load Response, 3.3 V Output, 10% to 90% Load Step Figure 11. Typical Isolated Output Supply Current vs. Input Current in All Supported Power Configurations Rev. D | Page 15 of 24 ADuM5401W/ADuM5402W/ADuM5403W Data Sheet 5V OUTPUT RIPPLE (10mV/DIV) 5 VISO (V) 4 10% LOAD 3 90% LOAD 2 0 –1.0 BW = 20MHz (400ns/DIV) –0.5 0 0.5 1.0 1.5 TIME (ms) 2.0 2.5 3.0 08758-031 08758-015 1 Figure 18. Typical Output Voltage Start-Up Transient at 10% and 90% Load, VISO = 3.3 V Figure 15. Typical VISO = 5 V Output Voltage Ripple at 90% Load 20 DATA RATE (Mbps) 5V INPUT/5V OUTPUT 3.3V INPUT/3.3V OUTPUT 5V INPUT/3.3V OUTPUT SUPPLY CURRENT (mA) 3.3V OUTPUT RIPPLE (10mV/DIV) 16 12 8 BW = 20MHz (400ns/DIV) 0 Figure 16. Typical VISO = 3.3 V Output Voltage Ripple at 90% Load 0 5 10 15 DATA RATE (Mbps) 20 25 08758-017 08758-016 4 Figure 19. Typical ICH Supply Current per Forward Data Channel (15 pF Output Load) 7 20 10% LOAD 5V INPUT/5V OUTPUT 3.3V INPUT/3.3V OUTPUT 5V INPUT/3.3V OUTPUT 6 SUPPLY CURRENT (mA) 16 4 90% LOAD 3 2 12 8 4 0 –1 0 1 TIME (ms) 2 3 0 0 5 10 15 DATA RATE (Mbps) 20 25 Figure 20. Typical ICH Supply Current per Reverse Data Channel (15 pF Output Load) Figure 17. Typical Output Voltage Start-Up Transient at 10% and 90% Load, VISO = 5 V Rev. D | Page 16 of 24 08758-120 1 08758-030 VISO (V) 5 Data Sheet ADuM5401W/ADuM5402W/ADuM5403W 3.0 5 2.5 SUPPLY CURRENT (mA) 3 5V 2 2.0 1.5 5V 1.0 3.3V 3.3V 1 0 0 0 5 10 15 20 DATA RATE (Mbps) 25 Figure 21. Typical IISO (D) Dynamic Supply Current per Input 0 5 10 15 DATA RATE (Mbps) 20 25 Figure 22. Typical IISO (D) Dynamic Supply Current per Output (15 pF Output Load) Rev. D | Page 17 of 24 08758-122 0.5 08758-121 SUPPLY CURRENT (mA) 4 ADuM5401W/ADuM5402W/ADuM5403W Data Sheet TERMINOLOGY IDD1 (Q) IDD1 (Q) is the minimum operating current drawn at the VDD1 pin when there is no external load at VISO and the I/O pins are operating below 2 Mbps, requiring no additional dynamic supply current. IDD1 (Q) reflects the minimum current operating condition. IDD1 (D) IDD1 (D) is the typical input supply current with all channels simultaneously driven at a maximum data rate of 25 Mbps with full capacitive load representing the maximum dynamic load conditions. Resistive loads on the outputs should be treated separately from the dynamic load. IDD1 (MAX) IDD1 (MAX) is the input current under full dynamic and VISO load conditions. IISO (LOAD) IISO (LOAD) is the current available to an external VISO load. tPHL Propagation Delay tPHL propagation delay is measured from the 50% level of the falling edge of the VIx signal to the 50% level of the falling edge of the VOx signal. tPLH Propagation Delay tPLH propagation delay is measured from the 50% level of the rising edge of the VIx signal to the 50% level of the rising edge of the VOx signal. Propagation Delay Skew (tPSK) tPSK is the magnitude of the worst-case difference in tPHL and/or tPLH that is measured between units at the same operating temperature, supply voltages, and output load within the recommended operating conditions. Channel-to-Channel Matching (tPSKCD/tPSKOD) Channel-to-channel matching is the absolute value of the difference in propagation delays between the two channels when operated with identical loads. Minimum Pulse Width The minimum pulse width is the shortest pulse width at which the specified pulse width distortion is guaranteed. Maximum Data Rate The maximum data rate is the fastest data rate at which the specified pulse width distortion is guaranteed. Rev. D | Page 18 of 24 Data Sheet ADuM5401W/ADuM5402W/ADuM5403W APPLICATIONS INFORMATION The dc-to-dc converter section of the ADuM5401W/ ADuM5402W/ADuM5403W works on principles that are common to most modern power supplies. It is a secondary side controller architecture with isolated pulse-width modulation (PWM) feedback. VDD1 power is supplied to an oscillating circuit that switches current into a chip scale air core transformer. Power transferred to the secondary side is rectified and regulated to either 3.3 V or 5 V. The secondary (VISO) side controller regulates the output by creating a PWM control signal that is sent to the primary (VDD1) side by a dedicated iCoupler data channel. The PWM modulates the oscillator circuit to control the power being sent to the secondary side. Feedback allows for significantly higher power and efficiency. The ADuM5401W/ADuM5402W/ADuM5403W implement undervoltage lockout (UVLO) with hysteresis on the VDD1 power input. This feature ensures that the converter does not enter oscillation due to noisy input power or slow power-on ramp rates. In the original ADuM540xW devices, a minimum load current of 10 mA is recommended to ensure optimum load regulation. Smaller loads can generate excess noise on chip due to short or erratic PWM pulses. Excess noise generated in this way can cause data corruption in some circumstances. This requirement has been removed in the newer ADuM540xW-1 devices, which are recommended for new designs. PCB LAYOUT The ADuM5401W/ADuM5402W/ADuM5403W digital isolators with 0.5 W isoPower integrated dc-to-dc converters require no external interface circuitry for the logic interfaces. Power supply bypassing is required at the input and output supply pins (see Figure 23). Note that a low ESR bypass capacitor is required between Pin 1 and Pin 2 as well as between Pin 15 and Pin 16, as close to the chip pads as possible. The power supply section of the ADuM5401W/ADuM5402W/ ADuM5403W uses a 180 MHz oscillator frequency to efficiently pass power through its chip scale transformers. In addition, normal operation of the data section of the iCoupler introduces switching transients on the power supply pins. Bypass capacitors are required for several operating frequencies. Noise suppression requires a low inductance, high frequency capacitor; ripple suppression and proper regulation require a large value capacitor. These are most conveniently connected between Pin 1 and Pin 2 for VDD1 and between Pin 15 and Pin 16 for VISO. To suppress noise and reduce ripple, a parallel combination of at least two capacitors is required. The recommended capacitor values are 0.1 µF and 10 µF for VDD1 and VISO. A 10 nF capacitor should be used for optimum EMI emissions performance. The smaller capacitors must have a low ESR; for example, use of an NPO ceramic capacitor is advised. Note that the total lead length between the ends of the low ESR capacitor and the input power supply pin must not exceed 2 mm. Installing the bypass capacitor with traces more than 2 mm in length may result in data corruption. A bypass between Pin 1 and Pin 8 and between Pin 9 and Pin 16 should also be considered unless both common ground pins are connected together close to the package. BYPASS < 2mm VDD1 GND1 VIA VISO GNDISO VOA VIB/VOB VOB/VIB VIC/VOC VOC/VIC VOD RCOUT GND1 VID VSEL GNDISO 08758-020 THEORY OF OPERATION Figure 23. Recommended Printed Circuit Board Layout In applications involving high common-mode transients, ensure that board coupling across the isolation barrier is minimized. Furthermore, design the board layout such that any coupling that does occur affects all pins equally on a given component side. Failure to ensure this can cause voltage differentials between pins, exceeding the absolute maximum ratings specified in Table 19, thereby leading to latch-up and/or permanent damage. The ADuM5401W/ADuM5402W/ADuM5403W are power devices that dissipate about 1 W of power when fully loaded and running at maximum speed. Because it is not possible to apply a heat sink to an isolation device, the devices primarily depend on heat dissipation into the PCB through the ground pins. If the devices are used at high ambient temperatures, provide a thermal path from the ground pins to the PCB ground plane. The board layout in Figure 23 shows enlarged pads for Pin 8 and Pin 9. Large diameter vias should be implemented from the pad to the ground, and power planes should be used to reduce inductance. Multiple vias in the thermal pads can significantly reduce temperatures inside the chip. The dimensions of the expanded pads are left to the discretion of the designer and the available board space. THERMAL ANALYSIS The ADuM5401W/ADuM5402W/ADuM5403W parts consist of four internal die attached to a split lead frame with two die attach paddles. For the purposes of thermal analysis, the die is treated as a thermal unit, with the highest junction temperature reflected in the θJA value from Table 14. The value of θJA is based on measurements taken with the parts mounted on a JEDEC standard, 4-layer board with fine width traces and still air. Under normal operating conditions, the ADuM5401W/ADuM5402W/ ADuM5403W devices operate at full load across the full temperature range without derating the output current. However, following the recommendations in the PCB Layout section decreases thermal resistance to the PCB, allowing increased thermal margins in high ambient temperatures. Rev. D | Page 19 of 24 ADuM5401W/ADuM5402W/ADuM5403W PROPAGATION DELAY RELATED PARAMETERS Propagation delay is a parameter that describes the time it takes a logic signal to propagate through a component (see Figure 24). The propagation delay to a logic low output may differ from the propagation delay to a logic high. INPUT (VIx) 50% OUTPUT (VOx) tPHL 08758-021 tPLH 50% Figure 24. Propagation Delay Parameters Pulse width distortion is the maximum difference between these two propagation delay values and is an indication of how accurately the input signal timing is preserved. Channel-to-channel matching refers to the maximum amount the propagation delay differs between channels within a single ADuM5401W/ADuM5402W/ADuM5403W component. Propagation delay skew refers to the maximum amount the propagation delay differs between multiple ADuM5401W/ ADuM5402W/ADuM5403W components operating under the same conditions. Data Sheet As a result, the ADuM5401W/ADuM5402W/ADuM5403W devices can draw large amounts of current at low voltage for extended periods of time. The output voltage of the ADuM5401W/ADuM5402W/ ADuM5403W devices exhibits VISO overshoot during startup. If this overshoot could potentially damage components attached to VISO, a voltage-limiting device such as a Zener diode can be used to clamp the voltage. Typical behavior is shown in Figure 17 and Figure 18. EMI CONSIDERATIONS The dc-to-dc converter section of the ADuM5401W/ADuM5402W/ ADuM5403W components must, of necessity, operate at a very high frequency to allow efficient power transfer through the small transformers. This creates high frequency currents that can propagate in circuit board ground and power planes, causing edge and dipole radiation. Grounded enclosures are recommended for applications that use these devices. If grounded enclosures are not possible, follow good RF design practices in the layout of the PCB. See the AN-0971 Application Note for board layout recommendations. DC CORRECTNESS AND MAGNETIC FIELD IMMUNITY START-UP BEHAVIOR The ADuM5401W/ADuM5402W/ADuM5403W do not contain a soft start circuit. Therefore, the start-up current and voltage behavior must be taken into account when designing with these devices. When power is applied to VDD1, the input switching circuit begins to operate and draw current when the UVLO minimum voltage is reached. The switching circuit drives the maximum available power to the output until it reaches the regulation voltage where PWM control begins. The amount of current and the time required to reach regulation voltage depends on the load and the VDD1 slew rate. With a fast VDD1 slew rate (200 μs or less), the peak current draws up to 100 mA/V of VDD1. The input voltage goes high faster than the output can turn on; therefore, the peak current is proportional to the maximum input voltage. With a slow VDD1 slew rate (in the millisecond range), the input voltage is not changing quickly when VDD1 reaches the UVLO minimum voltage. The current surge is approximately 300 mA because VDD1 is nearly constant at the 2.7 V UVLO voltage. The behavior during startup is similar to when the device load is a short circuit; these values are consistent with the short-circuit current shown in Figure 12. When starting the device for VISO = 5 V operation, do not limit the current available to the VDD1 power pin to less than 300 mA. The ADuM5401W/ADuM5402W/ADuM5403W devices may not be able to drive the output to the regulation point if a current-limiting device clamps the VDD1 voltage during startup. Positive and negative logic transitions at the isolator input cause narrow (~1 ns) pulses to be sent to the decoder via the transformer. The decoder is bistable and is, therefore, either set or reset by the pulses, indicating input logic transitions. In the absence of logic transitions at the input for more than 1 μs, periodic sets of refresh pulses indicative of the correct input state are sent to ensure dc correctness at the output. If the decoder receives no internal pulses for more than approximately 5 μs, the input side is assumed to be unpowered or nonfunctional, in which case, the isolator output is forced to a default low state by the watchdog timer circuit. This situation should occur only during power-up and power-down operations. The limitation on the magnetic field immunity of the ADuM5401W/ADuM5402W/ADuM5403W is set by the condition in which induced voltage in the receiving coil of the transformer is sufficiently large to either falsely set or reset the decoder. The following analysis defines the conditions under which this can occur. The pulses at the transformer output have an amplitude of >1.0 V. The decoder has a sensing threshold of about 0.5 V, thus establishing a 0.5 V margin in which induced voltages can be tolerated. The voltage induced across the receiving coil is given by V = (−dβ/dt)∑πrn2; n = 1, 2, … , N where: β is the magnetic flux density (gauss). rn is the radius of the nth turn in the receiving coil (cm). N is the number of turns in the receiving coil. Given the geometry of the receiving coil in the ADuM5401W/ ADuM5402W/ADuM5403W, and an imposed requirement that Rev. D | Page 20 of 24 Data Sheet ADuM5401W/ADuM5402W/ADuM5403W the induced voltage be, at most, 50% of the 0.5 V margin at the decoder, a maximum allowable magnetic field is calculated as shown in Figure 25. MAXIMUM ALLOWABLE MAGNETIC FLUX DENSITY (kgauss) 100 POWER CONSUMPTION 10 1 0.1 08758-022 0.01 0.001 1k Note that, in combinations of strong magnetic field and high frequency, any loops formed by PCB traces can induce error voltages sufficiently large to trigger the thresholds of succeeding circuitry. Exercise care in the layout of such traces to avoid this possibility. 1M 10k 100k 10M MAGNETIC FIELD FREQUENCY (Hz) 100M The VDD1 power supply input provides power to the iCoupler data channels, as well as to the power converter. For this reason, the quiescent currents drawn by the power converter and the primary and secondary I/O channels cannot be determined separately. All of these quiescent power demands have been combined into the IDD1 (Q) current, as shown in Figure 27. The total IDD1 supply current is equal to the sum of the quiescent operating current; the dynamic current, IDD1 (D), demanded by the I/O channels; and any external IISO load. IDD1(Q) Figure 25. Maximum Allowable External Magnetic Flux Density IDD1(D) For example, at a magnetic field frequency of 1 MHz, the maximum allowable magnetic field of 0.2 kgauss induces a voltage of 0.25 V at the receiving coil. This voltage is approximately 50% of the sensing threshold and does not cause a faulty output transition. Similarly, if such an event occurs during a transmitted pulse (and is of the worst-case polarity), it reduces the received pulse from >1.0 V to 0.75 V, which is still well above the 0.5 V sensing threshold of the decoder. The preceding magnetic flux density values correspond to specific current magnitudes at given distances from the ADuM5401W/ ADuM5402W/ADuM5403W transformers. Figure 26 expresses these allowable current magnitudes as a function of frequency for selected distances. As shown in Figure 26, the ADuM5401W/ ADuM5402W/ADuM5403W are extremely immune and can be affected only by extremely large currents operated at high frequency very close to the component. For the 1 MHz example, a 0.5 kA current placed 5 mm away from the ADuM5401W/ADuM5402W/ ADuM5403W is required to affect component operation. IDDP(D) DISTANCE = 100mm DISTANCE = 5mm 0.1 0.01 100k SECONDARY DATA INPUT/OUTPUT 4-CHANNEL Figure 27. Power Consumption Within the ADuM5401W/ADuM5402W/ADuM5403W Dynamic I/O current is consumed only when operating a channel at speeds higher than the refresh rate of fr. The dynamic current of each channel is determined by its data rate. Figure 19 shows the current for a channel in the forward direction, meaning that the input is on the VDD1 side of the part; Figure 20 shows the current for a channel in the reverse direction, meaning that the input is on the VISO side of the part. Both figures assume a typical 15 pF load. The following relationship allows the total IDD1 current to be calculated: (1) where: IDD1 is the total supply input current. ICHn is the current drawn by a single channel determined from Figure 19 or Figure 20, depending on channel direction. IISO is the current drawn by the secondary side external load. E is the power supply efficiency at 100 mA load from Figure 9 at the VISO and VDD1 condition of interest. 1 10k IISO(D) IDD1 = (IISO × VISO)/(E × VDD1) + Σ ICHn; n = 1 to 4 10 1k CONVERTER SECONDARY 08758-024 PRIMARY DATA INPUT/OUTPUT 4-CHANNEL DISTANCE = 1m 100 08758-023 MAXIMUM ALLOWABLE CURRENT (kA) 1k IISO CONVERTER PRIMARY 1M 10M The maximum external load can be calculated by subtracting the dynamic output load from the maximum allowable load. IISO (LOAD) = IISO (MAX) − Σ IISO (D)n; n = 1 to 4 100M MAGNETIC FIELD FREQUENCY (Hz) Figure 26. Maximum Allowable Current for Various Current-to-ADuM5401W/ADuM5402W/ADuM5403W Spacings (2) where: IISO (LOAD) is the current available to supply an external secondary side load. IISO (MAX) is the maximum external secondary side load current Rev. D | Page 21 of 24 ADuM5401W/ADuM5402W/ADuM5403W available at VISO. IISO (D)n is the dynamic load current drawn from VISO by an input or output channel, as shown in Figure 21 and Figure 22. The preceding analysis assumes a 15 pF capacitive load on each data output. If the capacitive load is larger than 15 pF, the additional current must be included in the analysis of IDD1 and IISO (LOAD). POWER CONSIDERATIONS The ADuM5401W/ADuM5402W/ADuM5403W power input, data input channels on the primary side, and data channels on the secondary side are all protected from premature operation by UVLO circuitry. Below the minimum operating voltage, the power converter holds its oscillator inactive and all input channel drivers and refresh circuits are idle. Outputs remain in a high impedance state to prevent transmission of undefined states during power-up and power-down operations. During application of power to VDD1, the primary side circuitry is held idle until the UVLO preset voltage is reached. At that time, the data channels initialize to their default low output state until they receive data pulses from the secondary side. When the primary side is above the UVLO threshold, the data input channels sample their inputs and begin sending encoded pulses to the inactive secondary output channels. The outputs on the primary side remain in their default low state because no data comes from the secondary side inputs until secondary power is established. The primary side oscillator also begins to operate, transferring power to the secondary power circuits. The secondary VISO voltage is below its UVLO limit at this point; the regulation control signal from the secondary is not being generated. The primary side power oscillator is allowed to free run in this circumstance, supplying the maximum amount of power to the secondary side, until the secondary voltage rises to its regulation setpoint. This creates a large inrush current transient at VDD1. When the regulation point is reached, the regulation control circuit produces the regulation control signal that modulates the oscillator on the primary side. The VDD1 current is reduced and is then proportional to the load current. The inrush current is less than the short-circuit current shown in Figure 12. The duration of the inrush current depends on the VISO loading conditions and the current available at the VDD1 pin. As the secondary side converter begins to accept power from the primary, the VISO voltage starts to rise. When the secondary side UVLO is reached, the secondary side outputs are initialized to their default low state until data is received from the corresponding primary side input. It can take up to 1 µs after the secondary side is initialized for the state of the output to correlate with the primary side input. Secondary side inputs sample their state and transmit it to the primary side. Outputs are valid about 1 µs after the secondary side becomes active. Data Sheet Because the rate of charge of the secondary side power supply is dependent on loading conditions, the input voltage, and the output voltage level selected, take care with the design to allow the converter sufficient time to stabilize before valid data is required. When power is removed from VDD1, the primary side converter and coupler shut down when the UVLO level is reached. The secondary side stops receiving power and starts to discharge. The outputs on the secondary side hold the last state that they received from the primary side. Either the UVLO level is reached and the outputs are placed in their high impedance state, or the outputs detect a lack of activity from the primary side inputs and the outputs are set to their default low value before the secondary power reaches UVLO. INSULATION LIFETIME All insulation structures eventually break down when subjected to voltage stress over a sufficiently long period. The rate of insulation degradation is dependent on the characteristics of the voltage waveform applied across the insulation. Analog Devices conducts an extensive set of evaluations to determine the lifetime of the insulation structure within the ADuM5401W/ADuM5402W/ ADuM5403W. Accelerated life testing is performed using voltage levels higher than the rated continuous working voltage. Acceleration factors for several operating conditions are determined, allowing calculation of the time to failure at the working voltage of interest. The values shown in Table 20 summarize the peak voltages for 50 years of service life in several operating conditions. In many cases, the working voltage approved by agency testing is higher than the 50-year service life voltage. Operation at working voltages higher than the service life voltage listed leads to premature insulation failure. The insulation lifetime of the ADuM5401W/ADuM5402W/ ADuM5403W depends on the voltage waveform type imposed across the isolation barrier. The iCoupler insulation structure degrades at different rates, depending on whether the waveform is bipolar ac, unipolar ac, or dc. Figure 28, Figure 29, and Figure 30 illustrate these different isolation voltage waveforms. Bipolar ac voltage is the most stringent environment. A 50-year operating lifetime under the bipolar ac condition determines the maximum working voltage recommended by Analog Devices. In the case of unipolar ac or dc voltage, the stress on the insulation is significantly lower. This allows operation at higher working voltages while still achieving a 50-year service life. The working voltages listed in Table 20 can be applied while maintaining the 50-year minimum lifetime, provided that the voltage conforms to either the unipolar ac or dc voltage cases. Any cross-insulation voltage waveform that does not conform to Figure 29 or Figure 30 should be treated as a bipolar ac waveform, and its peak voltage should be limited to the 50-year lifetime voltage value listed in Table 20. Rev. D | Page 22 of 24 Data Sheet ADuM5401W/ADuM5402W/ADuM5403W Symptom 08758-025 RATED PEAK VOLTAGE The VISO output voltage restarts to an incorrect voltage between 3.4 V and 4.7 V when power is removed at VDD1 and then reapplied between 250 ms and 3 sec later. The error occurs only on restart; it does not occur at initial power-up. If the part initializes incorrectly, power must be removed for an extended time to allow internal nodes to discharge and reset. The amount of time required can be several minutes at low temperature; therefore, it is critical to avoid allowing the device to initialize improperly. Figure 28. Bipolar AC Waveform 08758-026 RATED PEAK VOLTAGE Figure 29. DC Waveform Cause The secondary side band gap reference does not initialize to the proper voltage due to a slow slew rate on VISO after the internal nodes are precharged during the previous power cycle. The secondary side band gap sets the output voltage of the regulator. RATED PEAK VOLTAGE 0V Solution 08758-027 NOTES 1. THE VOLTAGE IS SHOWN AS SINUSOIDAL FOR ILLUSTRATION PURPOSES ONLY. IT IS MEANT TO REPRESENT ANY VOLTAGE WAVEFORM VARYING BETWEEN 0V AND SOME LIMITING VALUE. THE LIMITING VALUE CAN BE POSITIVE OR NEGATIVE, BUT THE VOLTAGE CANNOT CROSS 0V. Figure 30. Unipolar AC Waveform VISO START-UP ISSUES An issue with reliable startup was identified in the ADuM5401W/ ADuM5402W/ADuM5403W components. This issue has been addressed in the ADuM5401W-1/ADuM5402W-1/ADuM5403W1 for the current silicon. The ADuM5401W-1/ADuM5402W-1/ ADuM5403W-1 devices are recommended for all new designs. The following description applies only to the original released version of these devices. Production of the original release of the devices is being continued for existing customers, but it is not recommended for new designs. The slew rate of VISO is determined by the resistive and capacitive load present on the output. Designs that attempt to reduce ripple by adding capacitance to the VISO output can slow the slew rate enough to cause start-up errors. Choose values for bulk capacitance based on the effective dc load. Calculate the dc load as the resistive equivalent to the current drawn from the VISO line. Determine the range of allowable capacitance for the VISO output from Figure 31. Choose the bulk capacitance for VISO to achieve the application required ripple, unless the value is in the disallowed combinations area; then the value must be reduced to avoid restart issues. The start-up issue in the original release of the ADuM5401W/ ADuM5402W/ADuM5403W is related to initialization of the band gap voltage references on the primary (power input) and secondary (power output) sides of the isoPower device and are being addressed in future revisions of the silicon. For current versions of the silicon, the user must follow these design guidelines to guarantee proper operation of the device. The band gap voltage references are vulnerable to slow power-up slew rate. The susceptibility to power-up errors is process sensitive; therefore, not all devices display these behaviors. These recommendations should be implemented for all designs until the corrections are made to the silicon. The symptoms and corrective actions required for issues with the primary and secondary side startup are different. Rev. D | Page 23 of 24 100k 10k DISALLOWED COMBINATIONS 1k 100 10 08758-028 0V RVISO (Ω) 0V 1 1 10 100 CVISO (µF) Figure 31. Maximum Capacitive Load for Proper Restart 1k ADuM5401W/ADuM5402W/ADuM5403W Data Sheet OUTLINE DIMENSIONS 10.50 (0.4134) 10.10 (0.3976) 9 16 7.60 (0.2992) 7.40 (0.2913) 10.65 (0.4193) 10.00 (0.3937) 8 1.27 (0.0500) BSC 0.30 (0.0118) 0.10 (0.0039) COPLANARITY 0.10 0.75 (0.0295) 45° 0.25 (0.0098) 2.65 (0.1043) 2.35 (0.0925) SEATING PLANE 0.51 (0.0201) 0.31 (0.0122) 8° 0° 0.33 (0.0130) 0.20 (0.0079) COMPLIANT TO JEDEC STANDARDS MS-013-AA CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS (IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN. 1.27 (0.0500) 0.40 (0.0157) 03-27-2007-B 1 Figure 32. 16-Lead Standard Small Outline Package [SOIC_W] Wide Body (RW-16) Dimensions shown in millimeters and (inches) ORDERING GUIDE Model 1, 2, 3 ADuM5401WCRWZ-1 ADuM5402WCRWZ-1 ADuM5403WCRWZ-1 ADuM5401WCRWZ ADuM5402WCRWZ ADuM5403WCRWZ Notes 4 4 4 Number of Inputs, VDD1 Side 3 2 1 3 2 1 Number of Inputs, VISO Side 1 2 3 1 2 3 Maximum Data Rate (Mbps) 25 25 25 25 25 25 Maximum Propagation Delay, 5 V (ns) 60 60 60 60 60 60 Maximum Pulse Width Distortion (ns) 6 6 6 6 6 6 Temperature Range −40°C to +105°C −40°C to +105°C −40°C to +105°C −40°C to +105°C −40°C to +105°C −40°C to +105°C Package Description 16-Lead SOIC_W 16-Lead SOIC_W 16-Lead SOIC_W 16-Lead SOIC_W 16-Lead SOIC_W 16-Lead SOIC_W Package Option RW-16 RW-16 RW-16 RW-16 RW-16 RW-16 Z = RoHS Compliant Part. W = Qualified for Automotive Applications. Tape and reel are available. The addition of an RL suffix designates a 13” (1,000 units) tape and reel option. 4 This device is not recommended for new designs. 1 2 3 AUTOMOTIVE PRODUCTS The ADuM5401W/ADuM5402W/ADuM5403W models are available with controlled manufacturing to support the quality and reliability requirements of automotive applications. Note that these automotive models may have specifications that differ from the commercial models; therefore, designers should review the Specifications section of this data sheet carefully. Only the automotive grade products shown are available for use in automotive applications. Contact your local Analog Devices account representative for specific product ordering information and to obtain the specific Automotive Reliability reports for these models. ©2010–2013 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D08758-0-4/13(D) Rev. D | Page 24 of 24