ETC BK/AGCV3/8

Bussmann®
Fast-Acting Glass Fuses
AGC
AGC-V
For ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (6.3mm ≈ 32mm)
1.250
(±0.031)
31.85mm
Dimensional Data
.250
6.35mm
.2660
6.76mm
⁄Ω™º–15 AMP: .0320 (REF)
.81mm
20–30 AMP: .0400 (REF)
1.02mm
Rated
Current
⁄Ω™º
⁄Ω¡§
⁄Ω¡º
⁄Ω•
‹Ω¡§
¤Ω¡º
⁄Ω¢
‹Ω¡º
‹Ω•
4fiΩ¡ºº
⁄Ω™
‹Ω¢
1
1⁄Ω¢
1⁄Ω™
2
2⁄Ω¢
2⁄Ω™
3
4
5
6
7
8
9
10
15
20
25
30
AC (Max.)
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
32V
32V
32V
32V
DC6 (Max.)
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
32V
32V
32V
32V
Interrupting
Rating1
AC
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
100A
100A
100A
100A
100A
100A
200A
200A
200A
200A
200A
200A
200A
1000A
1000A
1000A
1000A
DC6
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
100A
100A
100A
100A
100A
100A
200A
200A
200A
200A
200A
200A
200A
1000A
1000A
1000A
1000A
AC
-4
2.60 ≈ 10
-4
2.40 ≈ 10
-4
5.50 ≈ 10
.003
.008
.011
.015
.044
.091
.12
.28
.82
1.50
1.95
3.44
5.4
6.0
5.3
12.19
25.08
7.08
10.52
13.27
24.56
211.00
240.30
577.00
1241.00
2276.00
3812.00
*Approvals: U.L. Listed, Std. 248-14, Guide JDYX, File E19180; CSA Certification,
Class 1422-01, File 53787; AGC & AGC-V U.L. Recognized, Guide JDYX2, File E19180.
1. Interrupting ratings were measured at 70%-80% power factor on AC, and at a time constant
described in U.L. 198L.
2. Voltage drop was measured at 25°C ± 3°C ambient temperature at rated current.
3. I2t was measured at listed interrupting rating and rated voltage.
4. Interrupting rating for AGC ⁄Ω∞ºº-10A @ 125V is 10,000A. Interrupting rating listed corresponds
to maximum rated voltage.
5. The AGC-10A fuse is self-certified for 32 Vdc at 1000 AIC.
6. Other available sizes include: ⁄Ω∞ºº, ⁄Ω™ºº, ⁄Ω¡ºº, ⁄Ω∞º, ⁄Ω£™, ⁄fi/¡ºº, ⁄‡fi/¡ººº, ⁄Ω£, ›/¡º, fl/¡º, °/¡º, 1¤/¡º,
1‹/¡º, 1fl/¡º, 1‹/¢, 1°/¡º, 3¤/¡º, 3⁄Ω™, 4⁄Ω™, 6⁄Ω¢, 7⁄Ω™, 12 and 14.
7. 1-10A, U.L. Recognized for 125 Vdc and 500 AIC. Other DC ratings are self-certified.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.
1-18-00
SB99210
Rev. A
DC6
4.09
-5
7.60 ≈ 10
-4
4.77 ≈ 10
.002
.007
.008
.014
.040
.072
.09
.24
.80
1.44
2.14
3.80
—
5.93
7.36
13.25
27.57
7.19
11.60
14.20
25.59
205.33
268.00
AC
-4
6.50 ≈ 10
-4
3.40 ≈ 10
-3
1.01 ≈ 10
.69
.84
.74
.38
1.57
2.59
2.78
2.75
3.69
5.21
10.69
16.41
22.14
19.04
19.70
27.29
74.91
39.80
59.49
67.68
104.90
238.40
315.70
691.00
1450.00
2588.00
4098.00
Agency*
Approvals
Typical Voltage
Drop2 Volts at
100% Rated
Current
.67
10.41
6.00
4.67
4.12
4.51
.89
2.88
4.59
2.67
.59
.37
.31
.35
.27
.28
.26
.31
.25
.22
.23
.23
.23
.19
.18
.20
.14
.12
.11
.12
Typical Total Clearing3
I2t (A2Sec)
Pre-arcing
I2t (A2Sec)
1.5000
38.10mm
(REF)
DC6
7.94
-4
2.12 ≈ 10
-3
1.27 ≈ 10
.003
.011
.013
.049
.051
.118
2.67
1.41
1.49
2.87
9.66
19.08
—
15.70
14.67
24.07
51.20
22.70
30.60
42.30
55.81
274.00
322.00
U.L.
Electrical Characteristics
Rated
Voltage
1.2920±.031
32.82mm±.79
CSA
Catalog Symbol: AGC (3AG)
Fast-Acting
*Agency Approvals: U.L./CSA 248-14
Construction: Glass Tube
Nickel-Plated Brass Endcaps
U.R.
1.5000
38.10mm
(REF)
.250
(±0.003)
6.35mm
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Time-Current Characteristics
Rated
Current
⁄Ω™º-30
Percent of Rating
135%
60 min. (max)
110%
4 hrs. (min)
200%
120 sec. (max)
Packaging & Ordering Information:
AGC
Package Code
Blank 5 in
BK/ 100 in
Product
Symbol
–
V
–
Lead
Blank -no lead
V-Axial lead
(See Table)
Rated Current
Form No. AGC
Page 1 of 2
BIF Doc #2001
Bussmann®
Fast-Acting Glass Fuses
AGC
AGC-V
For ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (6.3mm ≈ 32mm)
1.0 Typical Voltage Drop (At 25°C Ambient Temperture)
.6
8
⁄Ω¡§
6
⁄Ω¡§
4
⁄Ω•
¤Ω¡º
‹Ω¡º
VOLTAGE DROP
VOLTAGE DROP
10
2
⁄Ω™
.5
.4
‹Ω¢
1-14
1
1⁄Ω™
.3
.2
.1
⁄Ω¢
0
5%
50%
75%
25%
PERCENT OF RATED CURRENT
0
100%
.3
50%
75%
25%
PERCENT OF RATED CURRENT
100%
.2
.2
VOLTAGE DROP
2
3
.25
VOLTAGE DROP
5%
.15
7
5
4
.15
10
8
9
.1
15
20
25
30
.1
.05
.05
0
5%
50%
75%
25%
PERCENT OF RATED CURRENT
TIME IN SECONDS
10
1
.1
110
105
100
95
90
85
-30
0
25
50
AMBIENT TEMPERATURE °C
80
100
1,000
100
10
1
.1
CURRENT IN AMPERES
100%
115
80
-60
.01
50%
75%
25%
PERCENT OF RATED CURRENT
120
PERCENTAGE OF RATED CURRENT
100
5%
2.0 Ambient Temperature Effect Chart (Derating Curve)
AMPERE
RATING
30
4
5
7
10
15
1⁄Ω™
2⁄Ω™
2
⁄Ω™
1
flꭧ
Time-Current Characteristic Curves–Average Melt
(Full Size Curves Available)
⁄Ω¡§
⁄Ω¡º
0
100%
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin
is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
1-18-00
SB99210
Rev. A
Form No. AGC
Page 2 of 2
BIF Doc #2001