Bussmann® Fast-Acting Glass Fuses AGC AGC-V For ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (6.3mm ≈ 32mm) 1.250 (±0.031) 31.85mm Dimensional Data .250 6.35mm .2660 6.76mm ⁄Ω™º–15 AMP: .0320 (REF) .81mm 20–30 AMP: .0400 (REF) 1.02mm Rated Current ⁄Ω™º ⁄Ω¡§ ⁄Ω¡º ⁄Ω• ‹Ω¡§ ¤Ω¡º ⁄Ω¢ ‹Ω¡º ‹Ω• 4fiΩ¡ºº ⁄Ω™ ‹Ω¢ 1 1⁄Ω¢ 1⁄Ω™ 2 2⁄Ω¢ 2⁄Ω™ 3 4 5 6 7 8 9 10 15 20 25 30 AC (Max.) 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 32V 32V 32V 32V DC6 (Max.) 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 32V 32V 32V 32V Interrupting Rating1 AC 35A 35A 35A 35A 35A 35A 35A 35A 35A 35A 35A 35A 35A 100A 100A 100A 100A 100A 100A 200A 200A 200A 200A 200A 200A 200A 1000A 1000A 1000A 1000A DC6 35A 35A 35A 35A 35A 35A 35A 35A 35A 35A 35A 35A 35A 100A 100A 100A 100A 100A 100A 200A 200A 200A 200A 200A 200A 200A 1000A 1000A 1000A 1000A AC -4 2.60 ≈ 10 -4 2.40 ≈ 10 -4 5.50 ≈ 10 .003 .008 .011 .015 .044 .091 .12 .28 .82 1.50 1.95 3.44 5.4 6.0 5.3 12.19 25.08 7.08 10.52 13.27 24.56 211.00 240.30 577.00 1241.00 2276.00 3812.00 *Approvals: U.L. Listed, Std. 248-14, Guide JDYX, File E19180; CSA Certification, Class 1422-01, File 53787; AGC & AGC-V U.L. Recognized, Guide JDYX2, File E19180. 1. Interrupting ratings were measured at 70%-80% power factor on AC, and at a time constant described in U.L. 198L. 2. Voltage drop was measured at 25°C ± 3°C ambient temperature at rated current. 3. I2t was measured at listed interrupting rating and rated voltage. 4. Interrupting rating for AGC ⁄Ω∞ºº-10A @ 125V is 10,000A. Interrupting rating listed corresponds to maximum rated voltage. 5. The AGC-10A fuse is self-certified for 32 Vdc at 1000 AIC. 6. Other available sizes include: ⁄Ω∞ºº, ⁄Ω™ºº, ⁄Ω¡ºº, ⁄Ω∞º, ⁄Ω£™, ⁄fi/¡ºº, ⁄‡fi/¡ººº, ⁄Ω£, ›/¡º, fl/¡º, °/¡º, 1¤/¡º, 1‹/¡º, 1fl/¡º, 1‹/¢, 1°/¡º, 3¤/¡º, 3⁄Ω™, 4⁄Ω™, 6⁄Ω¢, 7⁄Ω™, 12 and 14. 7. 1-10A, U.L. Recognized for 125 Vdc and 500 AIC. Other DC ratings are self-certified. CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 1-18-00 SB99210 Rev. A DC6 4.09 -5 7.60 ≈ 10 -4 4.77 ≈ 10 .002 .007 .008 .014 .040 .072 .09 .24 .80 1.44 2.14 3.80 — 5.93 7.36 13.25 27.57 7.19 11.60 14.20 25.59 205.33 268.00 AC -4 6.50 ≈ 10 -4 3.40 ≈ 10 -3 1.01 ≈ 10 .69 .84 .74 .38 1.57 2.59 2.78 2.75 3.69 5.21 10.69 16.41 22.14 19.04 19.70 27.29 74.91 39.80 59.49 67.68 104.90 238.40 315.70 691.00 1450.00 2588.00 4098.00 Agency* Approvals Typical Voltage Drop2 Volts at 100% Rated Current .67 10.41 6.00 4.67 4.12 4.51 .89 2.88 4.59 2.67 .59 .37 .31 .35 .27 .28 .26 .31 .25 .22 .23 .23 .23 .19 .18 .20 .14 .12 .11 .12 Typical Total Clearing3 I2t (A2Sec) Pre-arcing I2t (A2Sec) 1.5000 38.10mm (REF) DC6 7.94 -4 2.12 ≈ 10 -3 1.27 ≈ 10 .003 .011 .013 .049 .051 .118 2.67 1.41 1.49 2.87 9.66 19.08 — 15.70 14.67 24.07 51.20 22.70 30.60 42.30 55.81 274.00 322.00 U.L. Electrical Characteristics Rated Voltage 1.2920±.031 32.82mm±.79 CSA Catalog Symbol: AGC (3AG) Fast-Acting *Agency Approvals: U.L./CSA 248-14 Construction: Glass Tube Nickel-Plated Brass Endcaps U.R. 1.5000 38.10mm (REF) .250 (±0.003) 6.35mm • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Time-Current Characteristics Rated Current ⁄Ω™º-30 Percent of Rating 135% 60 min. (max) 110% 4 hrs. (min) 200% 120 sec. (max) Packaging & Ordering Information: AGC Package Code Blank 5 in BK/ 100 in Product Symbol – V – Lead Blank -no lead V-Axial lead (See Table) Rated Current Form No. AGC Page 1 of 2 BIF Doc #2001 Bussmann® Fast-Acting Glass Fuses AGC AGC-V For ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (6.3mm ≈ 32mm) 1.0 Typical Voltage Drop (At 25°C Ambient Temperture) .6 8 ⁄Ω¡§ 6 ⁄Ω¡§ 4 ⁄Ω• ¤Ω¡º ‹Ω¡º VOLTAGE DROP VOLTAGE DROP 10 2 ⁄Ω™ .5 .4 ‹Ω¢ 1-14 1 1⁄Ω™ .3 .2 .1 ⁄Ω¢ 0 5% 50% 75% 25% PERCENT OF RATED CURRENT 0 100% .3 50% 75% 25% PERCENT OF RATED CURRENT 100% .2 .2 VOLTAGE DROP 2 3 .25 VOLTAGE DROP 5% .15 7 5 4 .15 10 8 9 .1 15 20 25 30 .1 .05 .05 0 5% 50% 75% 25% PERCENT OF RATED CURRENT TIME IN SECONDS 10 1 .1 110 105 100 95 90 85 -30 0 25 50 AMBIENT TEMPERATURE °C 80 100 1,000 100 10 1 .1 CURRENT IN AMPERES 100% 115 80 -60 .01 50% 75% 25% PERCENT OF RATED CURRENT 120 PERCENTAGE OF RATED CURRENT 100 5% 2.0 Ambient Temperature Effect Chart (Derating Curve) AMPERE RATING 30 4 5 7 10 15 1⁄Ω™ 2⁄Ω™ 2 ⁄Ω™ 1 flΩ¡º Time-Current Characteristic Curves–Average Melt (Full Size Curves Available) ⁄Ω¡§ ⁄Ω¡º 0 100% The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 1-18-00 SB99210 Rev. A Form No. AGC Page 2 of 2 BIF Doc #2001