ETC AIF28515Q/ES

LAMBDA ADVANCED ANALOG INC.
λ
PRELIMINARY
AIF28515Q
Quad Output, Hybrid - High Reliability
DC/DC Converter
DESCRIPTION
FEATURES
The AIF28515 DC/DC converter features an internal
EMI filter and four high performance outputs to
obtain a moderate power density without derating
over the full military temperature range. This device
also offers input conditioning for operation from
nominal +28 volt, MIL-STD 704A input power. This
series incorporates Lambda Advanced Analog's
proprietary magnetic pulse feedback technology
providing optimum dynamic line and load regulation
response. This feedback system samples the output
voltage at the pulse width modulator fixed clock
frequency, nominally 600 KHz.
Undervoltage
lockout, soft-start and load fault protection are
provided on this device.
n
18 To 50 Volt Continuous Input Range
n
Internal MIL-STD-461 Input EMI
n
Compatible with MIL-STD-704A Power Bus
n
45 Watts Output Power
n
Moderate Power Density ≈ 15 W / in3
n
Low Profile Seam Welded Package
n
Ceramic Feedthru Copper Core Pins
n
Operation Over Full Military Temperature
Range
n
Continuous Short Circuit and Overload
Protection
n
MIL-HDBK-217F, N2 MTBF of 50K hours at
71ºC, AUF
n
Device Weight < 100 gms
n
100 MΩ
Ω Isolation, Input to Output and Case
These converters are hermetically packaged in an
enclosure of modest dimension, utilizing copper
core pins to minimize resistive DC losses. These
pin leads are each fabricated with Lambda
Advanced Analog's rugged ceramic lead-to-package
seal assuring long term hermeticity in the most
harsh environments.
Manufactured in a facility fully qualified to MIL-PRF38534, these converters are available in several
screening grades to satisfy a range of requirements.
The HB grade is fully processed and screened to the
class H requirement of MIL-PRF-38534, but does
not have material element evaluated to the class H
requirement. This grade is tested to meet the
complete group "A" test specification over the full
military temperature range without output power
deration. Two additional grades with more modest
screening are also available for use in less
demanding applications. Variations in electrical,
mechanical and screening can be accommodated.
Contact Lambda Advanced Analog for special
requirements.
1
SPECIFICATIONS
AIF28515Q
ABSOLUTE MAXIMUM RATINGS
Input Voltage
-0.5 V to 50 V Continuous
+80 V for 100mSec
300°C for 10 seconds
Operating
-55°C to +125°C
Storage
-65°C to +135°C
Soldering Temperature
Case Temperature
Static Characteristics
-55°C ≤ TCASE ≤ +125°C, 18 ≤ VIN ≤ 50 unless otherwise specified.
Group A
Subgroups
Parameter
INPUT VOLTAGE
Test Conditions
Note 6
OUTPUT VOLTAGE
Min
Nom
Max
Unit
18
28
50
V
VIN = 28 Volts, 100% Load
1
1
Positive Output 1
Negative Output 1
4.95
-5.05
5.00
-5.00
5.05
-4.95
V
V
1
1
Positive Output 2
Negative Output 2
14.55
-15.45
15.00
-15.00
15.45
-14.55
V
V
2, 3
2, 3
Positive Output 1
Negative Output 1
4.90
-5.10
5.10
-4.90
V
V
2, 3
2, 3
Positive Output 2
Negative Output 2
14.70
-15.30
15.30
-14.70
V
V
OUTPUT CURRENT
VIN = 18, 28, 50 Volts - Notes 6, 11
Positive Output 1
A
Negative Output 1
A
Either Output 2
A
OUTPUT POWER
Total of All Outputs. Notes 6, 11
OUTPUT VOLTAGE
TEMPERATURE COEFFICIENT
VIN = 28 Volts, 100% Load - Notes 1, 6
OUTPUT VOLTAGE REGULATION
Line
Load
Cross
Positive Output 1
All other Outputs
1, 2, 3
1, 2, 3
1, 2, 3
OUTPUT RIPPLE VOLTAGE
1, 2, 3
INPUT CURRENT
Note 10
No Load, 50% Load, 100% Load
VIN = 18, 28, 50 Volts
45
W
-0.025
–0.075
+0.025
+0.075
%/°C
-10.0
-1.0
-1.0
+10.0
+1.0
+1.0
mV
%
%
30
50
100
mVpp
mVpp
mVpp
100
120
MA
mA
60
mApp
32
W
VIN = 18, 28, 50 Volts, 100% Load,
BW = 10MHz
Positive Output 1
Negative Output 1
Eother Output 2
VIN = 28 Volts, IOUT = 0
No Load
1
2, 3
INPUT RIPPLE CURRENT
1, 2, 3
LOAD FAULT
POWER DISSIPATION
1, 2, 3
EFFICIENCY
1, 2, 3
SWITCHING FREQUENCY
1, 2, 3
CURRENT LIMIT POINT
VIN = 28 Volts, 100% Load, BW = 10MHz
VIN = 28 Volts
100% Load
63
%
560
600
640
KHz
6.8
0.45
0.57
0.57
7.2
0.48
0.60
0.60
7.6
0.51
0.63
0.63
A
A
A
A
VOUT = 90% VNOM , VIN = 28 Volts, Note 5
Positive Output 1
Negative Output 1
Positive Output 2
Negative Otput 2
2
Dynamic Characteristics
Parameter
-55°C ≤ TCASE ≤ +125°C, VIN = 28 Volts unless otherwise specified.
Group A
Subgroups
LOAD TRANSIENT RESPONSE
Test Conditions
Min
Nom
Max
Unit
Note 2, 8
Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 50% ⇔ 100%
-250
250
250
mV
µSec
Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 10% ⇔ 50%
-250
250
250
mV
µSec
Negative Output 1 Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 50% ⇔ 100%
-40
40
200
mV
µSec
Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 10% ⇔ 50%
-40
40
200
mV
µSec
Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 50% ⇔ 100%
-500
500
200
mV
µSec
Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 10% ⇔ 50%
-500
500
200
mV
µSec
Negative Output 2 Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 50% ⇔ 100%
-500
500
200
mV
µSec
Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 10% ⇔ 50%
-500
500
200
mV
µSec
-200
200
500
mV
µSec
250
15
mV
mSec
5
mSec
Positive Output 1
Positive Output 2
LINE TRANSIENT RESPONSE
Note 1, 2, 3
VIN Step = 18 ⇔ 50 Volts
Amplitude
Recovery
TURN-ON CHARACTERISTICS
Overshoot
Delay
VIN = 18, 28, 50 Volts. Note 4
4, 5, 6
4, 5, 6
2
LOAD FAULT RECOVERY
Same as Turn On Characteristics.
LINE REJECTION
MIL-STD-461D, CS101, 30Hz to 50KHz
Note 1
CONDUCTED EMISSIONS
MIL-STD-461C, N2, 10 KHz – 50 MHz
45
< 20
50
dB
DB
Over
Spec
Limit
Notes to Specifications:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Parameters not 100% tested but are guaranteed to the limits specified in the table.
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of VOUT at 50% load.
Line transient transition time ≥ 100 µSec.
Turn-on delay is measured with an input voltage rise time of between 100 and 500 volts per millisecond.
Current limit point is that condition of excess load causing output voltage to drop to 90% of nominal.
Parameter verified as part of another test.
All electrical tests are performed with the remote sense leads connected to the output leads at the load.
Load transient transition time ≥ 12 µSec.
Enable inputs internally pulled high. Nominal open circuit voltage ≈ 4.0VDC.
Load regulation is tested with 50%load on the outputs not being tested.
Output load must be distributed so that a miniimum of 20% of the total output power is being provided by one of the outputs.
Cross regulation measured with load on tested output at 50% of maximum load while changing the load on the other outputs from 10% to 50%.
3
AIF28515Q Case Outline
Insert Case Drawing Here
4
AIF28515Q Pin Designation
Pin No.
Designation
1
N/C
2
N/C
3
N/C
4
N/C
5
+28 V Input
6
Input Return
7
Positive Output 1
8
Output 1 Return
9
Negative Output 1
10
Positive Output 2
11
Output 2 Return
12
Negative Output 2
Available Screening Levels and Process Variations for AIF28515Q Converters
Requirement
MIL-STD-883
Method
Temperature Range
No
Suffix
ES
Suffix
HB
Suffix
-20°C to +85°C
-55°C to +125°C
-55°C to +125°C
¬
ü
ü
Element Evaluation
Internal Visual
2017
Temperature Cycle
1010
Cond B
Cond C
Constant Acceleration
2001,
500g
Cond A
Burn-in
1015
96hrs @ 125°C
160hrs @ 125°C
25°C
25°C
-55, +25, +125°C
Cond C
Cond A, C
Cond A, C
¬
ü
ü
Final Electrical (Group A)
MIL-PRF-38534
Specification
Seal, Fine & Gross
1014
External Visual
2009
¬ per Commercial Standards
Part Numbering
AIF 28 515 S / CH
Model
Input Voltage
Screening
– , ES, HB
28 = 28V
Output Voltage
Outputs
515 = ±5, ±15
Q = Quad
5
Lambda Advanced Analog
The information in this data sheet has been carefully checked and is believed to be accurate; however no
responsibility is assumed for possible errors. These specifications are subject to change without notice.
LAMBDA ADVANCED ANALOG INC.
λ
MIL-PRF-38534 Qualified
ISO 9001 Registered
6
9811
2270 Martin Avenue
Santa Clara CA 95050-2781
(408) 988-4930 FAX (408) 988-2702