EMERSON-NETWORKPOWER ALO20F36-L

Astec Industry Standard
66Watts
Total Power:
Input Voltages:
No. of Outputs:
66 Watts
19 - 60V
Single
ALO20F36
Wide Range Input
Electrical Specs
Input
Input Range
Input Surge
19 to 60 VDC
100V /100ms
Efficiency2
91% @ 3.3V (typical)
Output
Line / Load Regulation
< 0.1% VO (typical)
Load Current
Up to 20A
Noise/Ripple1
50mVPK-PK (typical)
Transient Response
Over Voltage Protection
3% typical deviation
(50% to 75% Step Load)
< 200µs settling time
125% VO Typ (autorecovery)
Over Current Protection
125% IO,max Typ (autorecovery)
Over Temperature
Protection
Switching Frequency
Isolation Voltage
115ºC average PCB temperature
(autorecovery)
400KHz
1500Vdc
Special Features
•
•
•
•
•
•
2.3” x 0.9” Industry Standard 8th brick outline
Wide Operating Input Voltage Range
Regulation to zero load
High Efficiency
Fixed Frequency Switching for EMI predictability
Industry Standard features: Input UVLO with
hysteresis, Enable, OVP, OCP, OTP, Output
VoltageTrim, Differential Remote Sense
• Meets Basic Insulation
• EU Directive 2002/95/EC compliant for RoHS
Control
Output Voltage Trim
±10% VO,NOM
Enable
TTL compatible
(Positive or Negative Logic)
Environmental
Operating Ambient Temperature
Openframe: -40°C to +85°C Ambient
Storage temperature: -55°C to +125°C
MTBF: > 1 Million Hrs
Safety
UL, cUL 60950 Recognized
TUV EN60950 Licensed
2
North America (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
03.09.07
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Kwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
ALO20F36
Ordering Information
Input Voltage
19V to 60V
Output Voltage
Output Current
Efficiency2
3.3V
20A
91%
Model Number
ALO20F36(N) - (6)(L)
OPTIONS:
(N) : "N" = designates Negative Logic Enable (default is Positive Enable with no suffix “N” required)
(6) : "6" = 3.7mm nominal pin length (default is 5mm nominal pin length with no suffix “-6” required)
(L) : "L" = RoHS compliant (RoHS 6) / “Blank” = RoHS compliant with Lead (Pb) in solder exemption
Pin Assignment
Single Output
1. +Vin
2. Enable (On/Off)
3. -Vin
4. -VOUT
5. -Sense
6. Trim
7. +Sense
8. +VOUT
ALO - OPENFRAME
PIN 3
0.15
[3.8]
Notes:
0.15
[3.8]
PIN 4
0.30
[7.6]
0.45
[11.4]
0.45
[11.4]
0.75
[19.0]
0.60
[15.2]
0.75
[19.0]
PIN 8
PIN 1
PIN SIDE UP
0.32
[8.2]
See A
PIN LENGTH
A
Std Pin Length: 0.189 [4.8] MIN
0.205 [5.2] MAX
“-6” Option:
This is a Preliminary Data Sheet. Astec reserves the right to
make changes to the information contained herein without notice
and assumes no liability as a result of its use and application.
(REV 03: MARCH 8, 2007)
www.astecpower.com
0.137 [3.5] MIN
0.152 [3.9] MAX
Astec Industry Standard
1. 20 MHz bandwidth. External 10 uF tant. capacitor in
parallel with 0.1 uF ceramic capacitor placed across
the output and secondary return ground.
2. Efficiency measurements are typical values taken at
full load, 24V or 48V input and TA = 25°C.
3. All specifications are typical at nominal line, full load
and TA = 25°C unless otherwise noted.
4. All specifications subject to change without notice.
5. Mechanical drawings are for reference only.
Dimensions are in inches [mm]. Pin placement
tolerance ± 0.005 [0.127]. Mechanical Tolerance ±
0.02 [0.5]. Through hole pin diameter (Pins 4 & 8)
∅ = 0.062 [1.57], others ∅ = 0.04 [1.0] (6X).
6. Technical Reference Notes should be consulted for
detailed information when available.
7. Warranty 1yr.
2.00
[50.8]
3