BEL 0RQB

ISOLATED DC/DC CONVERTERS
36 - 75 Vdc Input
1.2 Vdc /100 A Output
0RQB-C8TV2x
RoHS Compliant
Rev.C
•
Isolated
•
Low Cost
•
Fixed Frequency (310 kHz)
•
Output Over-Voltage Protection
•
High Efficiency
•
Over Temperature Protection
•
High Power Density
•
SCP/OCP
•
Input Under-Voltage Protection
•
Remote On/Off
Description
The 0RQB-C8TV2x is an isolated dc/dc converter that operates from a nominal 48 Vdc source. This converter
provides up to 120 W of output power. Features include remote on/off, short circuit protection, over current
protection, over-temperature protection, output over-voltage protection, input under-voltage protection. This
converter is provided in a compact, though-hole package that is easy to use and provides good thermal
performance.
Part Selection
Output
Voltage
Input Voltage
Max. Output
Current
Max. Output
Power
Typical
Efficiency
Model Number
Active High
Model Number
Active Low
1.2 Vdc
36 Vdc - 75 Vdc
100 A
120 W
87%
0RQB-C8TV20
0RQB-C8TV2L
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Input Voltage
Min
-0.3 V
Typ
-
Max
80 V
Remote On/Off
-0.3 V
-
15 V
Ambient Temperature
-40 °C
-
85 °C
Storage Temperature
-55 °C
-
125 °C
Notes
100 V for 100 mS Max
Note: All specifications are typical at 25 °C unless otherwise stated.
Input Specifications
Parameter
Input Voltage
Min
36 V
Typ
48 V
Max
75 V
Input Current (full load)
-
-
4.5 A
Input Current (no load)
-
-
100 mA
Remote Off Input Current
-
5 mA
10 mA
-
20 mA
40 mA
-
5 mA
10 mA
-
-
0.1 A s
Input Reflected Ripple Current
(pk-pk)
Input Reflected Ripple Current
(rms)
2
I t Inrush Current Transient
Notes
With simulated source impedance of 10
uH, 5 Hz to 20 MHz; use a 47 uF/100 V
electrolytic capacitor with ESR = 1 ohm
max at 200 kHz
2
Turn-on Voltage Threshold
32 V
34 V
35 V
Turn-off Voltage Threshold
30 V
32 V
34 V
Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
36 - 75 Vdc Input
1.2 Vdc /100 A Output
Output Specifications
Parameter
Output Voltage Set Point
Min
1.176 V
Typ
1.2 V
Max
1.224 V
Notes
Vin=48 V, half load
Load Regulation
-
5 mV
10 mV
Vin=36-75 V, full load
Line Regulation
Regulation Over Temperature
(-40deg.C-85deg.C)
Output Current Range
-
2 mV
5 mV
Vin=48 V, Iout=0-120 A
-
-
0.01%Vo/C
0A
-
100 A
Output DC Current Limit
110 A
120 A
130 A
Ripple and Noise (rms)
-
15 mV
30 mV
Ripple and Noise (pk-pk)
-
50 mV
100 mV
Rise time
4 mS
8 mS
Power up
4 mS
8 mS
Remote on/off
70 mS
100 mS
Power up
-
70 mS
100 mS
Remote on/off
-
-
3%
0 uF
-
400,000 uF
Start-up time
Overshoot at Turn on
Output Capacitance
0 - 20 MHz BW, with a 10 uF
ceramic cap and a 330 uF tantalum
cap at output
Transient Response
50% ~ 75%
Max Load
75% ~ 50%
Max Load
Overshoot
-
80 mV
150 mV
Settling Time
-
200 uS
300 uS
-
80 mV
150 mV
-
200 uS
300 uS
Overshoot
VO=1.2 V
Settling Time
di/dt=0.1A/us, Vin=48 Vdc,
Ta=25 °C.
Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
General Specifications
Parameter
Min
-
Typ
87%
Max
-
Switching Frequency
290 kHz
310 kHz
330 kHz
Input to Output Isolation Voltage
1500 V
-
-
-
1500 pF
-
10 Mohm
-
-
1.40 V
-
1.54 V
Hiccup Mode
-
-
10%Vo
80%Vo
-
110%Vo
The total voltage increased by trim and
remote sense should not exceed 10%Vo.
-
120 °C
-
Efficiency
Isolation Capacitance
Isolation Resistance
Output Voltage Protection
Remote Sense Compensation
Output Voltage Trim Range
Over Temperature Protection
MTBF
Notes
Vin=48 V, full load
No Latch; PCB Temperature
Calculated Per Bell Core SR-332 (Vin=48
V, Io=normal , Ta = 25 °C)
TBD
Dimensions
Inches
millimeters
Weight
-
2.30 x 1.45 x 0.500
58.42 x 36.83 x 12.70
60.7 g
-
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
36 - 75 Vdc Input
1.2 Vdc /100 A Output
Control Specifications
Parameter
Min
Typ
Max
-0.3 V
-
0.8 V
2.4 V
-
18 V
-0.3 V
-
0.8 V
2.4 V
-
18 V
Notes
Remote On/Off
Signal Low (Unit On)
Signal High (Unit Off)
Signal Low (Unit Off)
Signal High (Unit On)
Active Low
Active High
The remote on/off pin open, Unit
Off.
The remote on/off pin open, Unit
On.
Output Trim Equations
Equations for calculating the trim resistor are shown below. The Trim Down resistor should be connected
between the Trim pin, GND pin and -sense pin. The Trim Up resistor should be connected between the Trim pin,
Vout pin and the +sense pin. Only one of the resistors should be used for any given application.
Rtrim_up( Vadj) :=
6.25 − 0.1⋅ ( 1 + delta) ⋅ Vo
0.51⋅ (1 + delta )⋅ Vo − 0.6125
Vout
+sense
Rtrim_up
Trim
-sense
GND
Rtrim_down( Vadj) :=
8.13 + 20⋅ (1 + delta)⋅ Vo
10.2 − 7.86⋅ ( 1 + delta )⋅ Vo
Vout
+sense
Trim
Rtrim_down
Note:
d e lta =
(V a d j − V o ) × 10 0
Vo
[% ]
-sense
GND
Vadj is the desired output voltage
Vo = 1.201V @Iout=0
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
36 - 75 Vdc Input
1.2 Vdc /100 A Output
Efficiency
Efficiency Data
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
Vin=36V
Vin=48V
Vin=75V
0
10
25
50
Io (%Iomax)
75
100
Thermal Derating Curve
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
36 - 75 Vdc Input
1.2 Vdc /100 A Output
Ripple and Noise Waveforms
36 Vdc input
48 Vdc input
75 Vdc input
Note: Ripple and noise at full load, with a 10 uF ceramic cap and a 330 uF tantalum cap at the output, and Ta=25
deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
36 - 75 Vdc Input
1.2 Vdc /100 A Output
Transients Responses Waveforms
50%-75% Load Transients at Vin=48 V
75%-50% Load Transients at Vin=48 V
Note: Transients response at di/dt=0.1 A/us, Vin=48 Vdc, Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
36 - 75 Vdc Input
1.2 Vdc /100 A Output
Mechanical Outline
Pin Connections
Pin
1
2
3
4
5
6
7
8
9
10
Function
Vin(+)
On/Off
Vin(-)
Vo(-)
Vo(-)
Sense(-)
Trim
Sense(+)
Vo(+)
Vo(+)
Pin Size
0.040’’
0.040’’
0.040’’
0.062’’
0.062’’
0.040’’
0.040’’
0.040’’
0.062’’
0.062’’
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
©2008 Bel Fuse Inc. Specifications subject to change without notice. 082608
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com