APC-12 series 12W Single Output Switching Power Supply MODEL:APC-12-350 OUTPUT FUNCTION TEST NO 1 TEST ITEM SPECICATION RIPPLE & NOISE V1: 300 mVp-p (Max ) TEST CONDITION RESULT I/P: 230 VAC V1: 45 VERDICT mVp-p (Max ) O/P:FULL LOAD Ta:25℃ 2 OUTPUT VOLTAGE V1: -5 %~ +5 % (Max) TOLERANCE 3 LINE REGULATION PASS I/P: 100VAC / 264 VAC V1: -0.05%~ 0.3 % O/P:FULL/ 0% LOAD Ta:25℃ V1: -1 %~ +1 % (Max) PASS I/P: 100 VAC ~ 264VAC V1: -0.01 %~ 0.03 % O/P:FULL LOAD Ta:25℃ 4 LOAD REGULATION V1: -3 %~ +3 % (Max) PASS I/P: 230 VAC V1: -0.1 %~ 0.3 % O/P:FULL ~MIN LOAD Ta:25℃ 5 SET UP TIME PASS 230VAC/ 3000 ms (Max) I/P: 230 VAC 230 VAC/ 868.557 ms 115VAC/ 3000 ms (Max) I/P: 115 VAC 115 VAC/ 572.812ms O/P:FULL LOAD Ta:25℃ 6 RISE TIME 230VAC/ 180 ms (Max) I/P: 230 VAC 230 VAC/ 137.648 ms 115VAC/ 150 ms (Max) I/P: 115 VAC 115 VAC/ 121.365 ms O/P:FULL LOAD Ta:25℃ 7 HOLD TIME 230VAC/ 20 ms (Typ) I/P: 230 VAC 230 VAC/ 82.954 ms 115VAC/ 15 ms (Typ) I/P: 115 VAC 115 VAC/ 18.886 ms O/P:FULL LOAD Ta:25℃ 8 OVER/UNDERSHOOT TEST < ±5 % TEST: I/P: 230 VAC PASS PASS PASS ±1.66% O/P:FULL LOAD Ta:25℃ PASS INPUT FUNCTION TEST NO 1 TEST ITEM SPECICATION TEST CONDITION INPUT VOLTAGE RANGE 90 VAC~ 264 VAC I/P:TESTING RESULT 90 VERDICT V~ 264 V O/P:FULL LOAD Ta:25℃ (1)I/P: LOW-LINE-3V= 87 V TEST: HIGH-LINE+15%= 300 V O/P:FULL/MIN LOAD ON: 30 Sec . OFF: 30 Sec (1) OK (2) OK PASS 10MIN (2) I/P:230VAC ON: 0.5 Sec . OFF: 0.5 Sec 20MIN ( AC POWER ON/OFF NO DAMAGE ) Model: APC-12-350 Test Report 1/5 APC-12 series 12W Single Output Switching Power Supply 2 3 INPUT FREQUENCY RANGE EFFICIENCY 47HZ ~63 HZ I/P: 90 VAC ~264 VAC NO DAMAGE OSC O/P:FULL~MIN LOAD Ta:25℃ 82 % (Typ) I/P: 230 VAC TEST: OK PASS 83.14 % O/P:FULL LOAD Ta:25℃ 4 INPUT CURRENT 230 V/ 0.2 115 V/ 0.35 A (Typ) A (Typ) PASS I/P: 230 VAC I =0.1474A/ 230VAC I/P: 115 VAC I =0.2463A/ 115VAC O/P:FULL LOAD Ta:25℃ 5 INRUSH CURRENT 230 V/ 70 A I/P: 230 VAC I =53.945 A/ 230VAC 115 V/ 35 A I/P: 115 VAC I =17.351 A/ 115VAC COLD START O/P:FULL LOAD Ta:25℃ PASS PASS PROTECTION FUNCTION TEST NO 1 2 TEST ITEM SPECICATION OVER VOLTAGE PROTECTION CH1: 39.6 SHORT PROTECTION V~ TEST CONDITION 46.8 V RESULT VERDICT I/P: 264 VAC 42.864 V/264VAC I/P: 230 VAC 42.864 V/ 230VAC I/P: 90 VAC 42.864 V/ 90VAC O/P:MIN LOAD Ta:25℃ Shut off O/P voltage, clamping by SHORT EVERY OUTPUT I/P: NO DAMAGE 1 HOUR NO DAMAGE O/P: FULL LOAD Ta:25℃ 264 VAC PASS zener diode Constant Current Limiting PASS ENVIRONMENT TEST NO TEST ITEM TEMPERATURE RISE TEST SPECICATION TEST CONDITION RESULT VERDICT MODEL: APC-12-350 1. ROOM AMBIENT BURN-IN: 2 HRS I/P: 230 VAC O/P: 100% LOAD Ta= 32.3 ℃ 2. HIGH AMBIENT BURN-IN: 2 HRS I/P: 230 VAC O/P: 100% LOAD NO 1 1 2 3 4 5 6 7 8 9 10 11 12 13 Ta= 45.1 Position BD1 L1 C5 C6 D1 U1 C9 T1 C2 D10 C15 C16 C17 P/N KBP208G DRGZ001D 12uF/400V KM 12uF/400V KM 1N4007 SD4843 10uF/50V YXF TF6318 22uF/50V KY HER306 100uF/50V GL 47uF/50V GL 47uF/50V GL ℃ ROOM AMBIENT HIGH AMBIENT Ta= 32.3 ℃ Ta= 45.1 ℃ 56.5℃ 70.5℃ 59.1℃ 73.0℃ 53.6℃ 67.4℃ 71.9℃ 85.3℃ 81.5℃ 94.5℃ 84.4℃ 97.8℃ 73.4℃ 86.3℃ 72.2℃ 84.8℃ 80.8℃ 93.7℃ 83.8℃ 95.5℃ 62.8℃ 75.3℃ 56.3℃ 68.9℃ 71.1℃ 83.6℃ Model: APC-12-350 PASS Test Report 2/5 APC-12 series 12W Single Output Switching Power Supply 2 LOW TEMPERATURE TURN ON AFTER 2 HOUR 3 4 I/P: 272 VAC HIGH VOLTAGE IN CHAMBER ON CONTROL 45 ℃ O/P:FULL LOAD Ta= 45 ℃ TURN ON TEST NO DAMAGE HUMIDITY= ± 0.2 %(0~50℃) STORAGE TEMPERATURE TEST PASS TEST: AFTER 12 HOURS HIGH TEMPERATURE OK PASS 95 %R.H ± 0.075 I/P: 230 VAC COEFFICIENT 5 OK O/P: 100% LOAD Ta= -30 ℃ HIGH HUMIDITY TEMPERATURE TEST: I/P: 264 VAC/100 VAC TURN ON TEST %(0~50℃) O/P:FULL LOAD TEST: 1. Thermal shock Temperature: -45℃~ +85℃ PASS OK 2. Temperature change rate :25℃ / MIN 3. Dwell time low and high temperature : 30 MIN/EACH PASS 4. Total test cycle:5 CYCLE 5. Input/Output condition: STATIC 6. THERMAL SHOCK TEST TEST: 1. Thermal shock Temperature: - 35 ℃~ + 50 ℃ OK 2. Temperature change rate :25℃ / MIN 3. Dwell time low and high temperature : 30 MIN/EACH PASS 4. Total test cycle:10 CYCLE 5. Input/Output condition: 230VAC/Full Load 58SEC ON/2SEC OFF 7 VIBRATION TEST TEST: 1 Carton & 1 Set OK (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle PASS (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) Ta:25℃ 8 CAPACITOR LIFE CYCLE 9 MTBF APC-12-350: SUPPOSE C15 IS THE MOST CRITICAL COMPONENT (1) I/P: 230 VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME= 187624 HRS (2) I/P: 230 VAC HRS O/P:FULL LOAD DMTBF/Accelerated Life Test LIFE TIME= 47892 PASS MIL-HDBK-217F NOTICES2 PARTS COUNT TOTAL FAILURE RATE: 10 Ta= 45 ℃ 1145.7K PASS HRS Demonstration Mean Time Between Failure(Expected Life) : 20,000 hours @ Tcase 70℃,50,000 hours @ Tcase 55℃ PASS SAFETY TEST 1 WITHSTAND VOLTAGE I/P-O/P: 3.75 KVAC/min EN 60950 2 3 ISOLATION RESISTANCE LEAKAGE CURRENT I/P-O/P:500VDC>100MΩ < 0.25 mA / 240VAC I/P-O/P: 4.2 Ta:25℃ I/P-O/P: 500 Ta:25℃ KVAC/min I/P-O/P: 1.883 mA NO DAMAGE VDC I/P-O/P: >9999 MΩ NO DAMAGE I/P: 264 VAC L-FG: 2.2 uA EN 60950 O/P:NO LOAD Ta:25℃ N-FG: 2.2 uA TEST ITEM SPECICATION TEST CONDITION RESULT HARMONIC EN61000-3-2 I/P: 220V/230V/240V AC 50HZ PASS CLASS A O/P:100%/75%/50%/25% LOAD Ta:25℃ EN55015 I/P:230 VAC (50HZ) /115V(60HZ) PASS O/P:FULL/50% LOAD Ta:25℃ Test by certified Lab PASS PASS PASS E.M.C TEST NO 1 2 CONDUCTION VERDICT PASS PASS Model: APC-12-350 Test Report 3/5 APC-12 series 12W Single Output Switching Power Supply 3 4 5 6 RADIATION E.S.D E.F.T SURGE EN55015 I/P: 230 VAC (50HZ)/115V(60HZ) PASS O/P:FULL LOAD Ta:25℃ Test by certified Lab EN61000-4-2 I/P: 230 VAC/50HZ CRITERIA A LIGHT INDUSTRY AIR:8KV / Contact:4KV O/P:FULL LOAD Ta:25℃ EN61000-4-4 I/P: 230 VAC/50HZ LIGHT INDUSTRY INPUT: 1KV O/P:FULL LOAD Ta:25℃ EN61000-4-5 I/P: 230 VAC/50HZ LIGHT INDUSTRY O/P:FULL LOAD Ta:25℃ L-N :2KV 7 PASS PASS CRITERIA A PASS CRITERIA A PASS Test by certified Lab & Test Report Prepare COMPONENT STRESS TEST NO 1 TEST ITEM SPECICATION Power Transistor U1 ( D to S) or (C to E) Peak Voltage TEST CONDITION Rated SD4843 RESULT VERDICT I/P:High-Line +3V =267 V : 650 V 11 A O/P: (1)Full Load input on/off (1)512V/1.42A (2)Output Short (2)460V/1.29A (3)Dynamic Load Full Load/ (3)516V/520mA Min. Load 90%Duty/3KHz (4)540V/810mA (4)Dynamic Load 50% Load/ Min. Load 50%Duty/120Hz I/P:Low-Line -3V = 87 V PASS O/P: (1)Full Load input on/off (1)274V/660mA (2)Output Short (2)158V/590mA (3)Dynamic Load Full Load/ (3)242V/430mA Min. Load 90%Duty/3KHz (4)286V/880mA (4)Dynamic Load 50% Load/ Min. Load 50%Duty/120Hz Ta:25℃ 2 Diode Peak Voltage D10 HER306 Rated : I/P:High-Line +3V = 267 600 V 3A V O/P: (1)Full Load input on/off (1)237 V (2)Output Short (2) 203V (3)Dynamic Load Full Load/ (3) 234V Min. Load 90%Duty/3KHz (4) 238V (4)Dynamic Load 50% Load/ Min. Load 50%Duty/120Hz I/P:Low-Line -3V = 87 V O/P: (1)Full Load input on/off PASS (1) 39.6V (2)Output Short (2) 41.6V (3)Dynamic Load Full Load/ (3) 36.0V Min. Load 90%Duty/3KHz (4)36.4 V (4)Dynamic Load 50% Load/ Min. Load 50%Duty/120Hz Ta:25℃ Model: APC-12-350 Test Report 4/5 APC-12 series 12W Single Output Switching Power Supply 3 Input Capacitor Voltage C5 Rated I/P:High-Line +3V =267 CAPXON : 12 u / 400 V 105℃/ KM Series V O/P: (1)Full Load input on/off (1) 398 (2)Min load input on /off (2) 390 (3)Burn-IN (3) 388 1Hour V V PASS V Ta:25℃ 4 Control IC Voltage Test U1 Rated SD4843 I/P:High-Line +3V = 267 : 21 V V O/P:(1).Output Short (1) 16.2V (2).O.L.P (2) 16.2V (3).O.V.P. (3) 16.2V (4).NO LOAD LOW LINE (4) 12.3V PASS Ta:25℃ 2007/11/26 A50-G058 DATE SAMPLE TEST RESULT TESTER APPROVAL 2010/11/1 RD SAMPLE PASS SKY HOWAY 2011/6/10 PRODUCT SAMPLE (W1106A171) PASS SKY HOWAY 2011/7/28 PRODUCT SAMPLE (W1107G151) PASS SKY HOWAY Model: APC-12-350 Test Report 5/5