MEANWELL APC-12-350

APC-12 series
12W Single Output Switching Power Supply
MODEL:APC-12-350
OUTPUT FUNCTION TEST
NO
1
TEST ITEM
SPECICATION
RIPPLE & NOISE
V1: 300
mVp-p (Max )
TEST CONDITION
RESULT
I/P: 230 VAC
V1: 45
VERDICT
mVp-p (Max )
O/P:FULL LOAD
Ta:25℃
2
OUTPUT VOLTAGE
V1: -5 %~ +5 % (Max)
TOLERANCE
3
LINE REGULATION
PASS
I/P: 100VAC / 264 VAC
V1: -0.05%~ 0.3
%
O/P:FULL/ 0% LOAD
Ta:25℃
V1: -1 %~ +1 % (Max)
PASS
I/P: 100 VAC ~ 264VAC
V1: -0.01 %~ 0.03 %
O/P:FULL LOAD
Ta:25℃
4
LOAD REGULATION
V1: -3 %~ +3 % (Max)
PASS
I/P: 230 VAC
V1: -0.1 %~ 0.3 %
O/P:FULL ~MIN LOAD
Ta:25℃
5
SET UP TIME
PASS
230VAC/ 3000
ms (Max)
I/P: 230 VAC
230 VAC/ 868.557 ms
115VAC/ 3000
ms (Max)
I/P: 115 VAC
115 VAC/ 572.812ms
O/P:FULL LOAD
Ta:25℃
6
RISE TIME
230VAC/ 180 ms (Max)
I/P: 230 VAC
230 VAC/ 137.648 ms
115VAC/ 150 ms (Max)
I/P: 115 VAC
115 VAC/ 121.365 ms
O/P:FULL LOAD
Ta:25℃
7
HOLD TIME
230VAC/ 20 ms (Typ)
I/P: 230 VAC
230 VAC/ 82.954 ms
115VAC/ 15 ms (Typ)
I/P: 115 VAC
115 VAC/ 18.886 ms
O/P:FULL LOAD
Ta:25℃
8
OVER/UNDERSHOOT TEST
< ±5 %
TEST:
I/P: 230 VAC
PASS
PASS
PASS
±1.66%
O/P:FULL LOAD
Ta:25℃
PASS
INPUT FUNCTION TEST
NO
1
TEST ITEM
SPECICATION
TEST CONDITION
INPUT VOLTAGE RANGE
90 VAC~ 264 VAC
I/P:TESTING
RESULT
90
VERDICT
V~ 264 V
O/P:FULL LOAD
Ta:25℃
(1)I/P: LOW-LINE-3V= 87 V
TEST:
HIGH-LINE+15%= 300 V
O/P:FULL/MIN LOAD
ON: 30 Sec . OFF: 30 Sec
(1) OK
(2) OK
PASS
10MIN
(2) I/P:230VAC
ON: 0.5 Sec . OFF: 0.5 Sec 20MIN
( AC POWER ON/OFF NO DAMAGE )
Model: APC-12-350
Test Report
1/5
APC-12 series
12W Single Output Switching Power Supply
2
3
INPUT FREQUENCY RANGE
EFFICIENCY
47HZ ~63 HZ
I/P: 90 VAC ~264 VAC
NO DAMAGE OSC
O/P:FULL~MIN LOAD
Ta:25℃
82 % (Typ)
I/P: 230 VAC
TEST:
OK
PASS
83.14 %
O/P:FULL LOAD
Ta:25℃
4
INPUT CURRENT
230 V/ 0.2
115 V/ 0.35
A (Typ)
A (Typ)
PASS
I/P: 230 VAC
I =0.1474A/ 230VAC
I/P: 115 VAC
I =0.2463A/ 115VAC
O/P:FULL LOAD
Ta:25℃
5
INRUSH CURRENT
230 V/
70
A
I/P: 230 VAC
I =53.945 A/ 230VAC
115 V/
35
A
I/P: 115 VAC
I =17.351 A/ 115VAC
COLD START
O/P:FULL LOAD
Ta:25℃
PASS
PASS
PROTECTION FUNCTION TEST
NO
1
2
TEST ITEM
SPECICATION
OVER VOLTAGE PROTECTION
CH1: 39.6
SHORT PROTECTION
V~
TEST CONDITION
46.8
V
RESULT
VERDICT
I/P: 264 VAC
42.864
V/264VAC
I/P: 230 VAC
42.864
V/ 230VAC
I/P: 90 VAC
42.864 V/ 90VAC
O/P:MIN LOAD
Ta:25℃
Shut off O/P voltage, clamping by
SHORT EVERY OUTPUT
I/P:
NO DAMAGE
1 HOUR NO DAMAGE
O/P: FULL LOAD
Ta:25℃
264 VAC
PASS
zener diode
Constant Current Limiting
PASS
ENVIRONMENT TEST
NO
TEST ITEM
TEMPERATURE RISE TEST
SPECICATION
TEST CONDITION
RESULT
VERDICT
MODEL: APC-12-350
1. ROOM AMBIENT BURN-IN:
2
HRS
I/P: 230 VAC O/P: 100% LOAD Ta= 32.3 ℃
2. HIGH AMBIENT BURN-IN:
2 HRS
I/P: 230 VAC O/P: 100% LOAD
NO
1
1
2
3
4
5
6
7
8
9
10
11
12
13
Ta= 45.1
Position
BD1
L1
C5
C6
D1
U1
C9
T1
C2
D10
C15
C16
C17
P/N
KBP208G
DRGZ001D
12uF/400V KM
12uF/400V KM
1N4007
SD4843
10uF/50V YXF
TF6318
22uF/50V KY
HER306
100uF/50V GL
47uF/50V GL
47uF/50V GL
℃
ROOM AMBIENT HIGH AMBIENT
Ta= 32.3 ℃
Ta= 45.1 ℃
56.5℃
70.5℃
59.1℃
73.0℃
53.6℃
67.4℃
71.9℃
85.3℃
81.5℃
94.5℃
84.4℃
97.8℃
73.4℃
86.3℃
72.2℃
84.8℃
80.8℃
93.7℃
83.8℃
95.5℃
62.8℃
75.3℃
56.3℃
68.9℃
71.1℃
83.6℃
Model: APC-12-350
PASS
Test Report
2/5
APC-12 series
12W Single Output Switching Power Supply
2
LOW TEMPERATURE
TURN ON AFTER
2 HOUR
3
4
I/P: 272 VAC
HIGH VOLTAGE
IN CHAMBER ON
CONTROL 45 ℃
O/P:FULL LOAD
Ta= 45 ℃
TURN ON TEST
NO DAMAGE
HUMIDITY=
± 0.2 %(0~50℃)
STORAGE TEMPERATURE TEST
PASS
TEST:
AFTER 12 HOURS
HIGH TEMPERATURE
OK
PASS
95 %R.H
± 0.075
I/P: 230 VAC
COEFFICIENT
5
OK
O/P: 100% LOAD
Ta= -30 ℃
HIGH HUMIDITY
TEMPERATURE
TEST:
I/P: 264 VAC/100 VAC
TURN ON TEST
%(0~50℃)
O/P:FULL LOAD
TEST:
1. Thermal shock Temperature: -45℃~ +85℃
PASS
OK
2. Temperature change rate :25℃ / MIN
3. Dwell time low and high temperature : 30 MIN/EACH
PASS
4. Total test cycle:5 CYCLE
5. Input/Output condition: STATIC
6.
THERMAL SHOCK TEST
TEST:
1. Thermal shock Temperature: - 35 ℃~ + 50 ℃
OK
2. Temperature change rate :25℃ / MIN
3. Dwell time low and high temperature : 30 MIN/EACH
PASS
4. Total test cycle:10 CYCLE
5. Input/Output condition: 230VAC/Full Load 58SEC ON/2SEC OFF
7
VIBRATION TEST
TEST:
1 Carton & 1 Set
OK
(1) Waveform: Sine Wave
(2) Frequency:10~500Hz
(3) Sweep Time:10min/sweep cycle
PASS
(4) Acceleration:2G
(5) Test Time:1 hour in each axis (X.Y.Z)
(6) Ta:25℃
8
CAPACITOR
LIFE CYCLE
9
MTBF
APC-12-350: SUPPOSE C15
IS THE MOST CRITICAL COMPONENT
(1) I/P: 230 VAC
O/P:FULL LOAD Ta= 25 ℃ LIFE TIME= 187624
HRS
(2) I/P: 230 VAC
HRS
O/P:FULL LOAD
DMTBF/Accelerated Life Test
LIFE TIME=
47892
PASS
MIL-HDBK-217F NOTICES2 PARTS COUNT
TOTAL FAILURE RATE:
10
Ta= 45 ℃
1145.7K
PASS
HRS
Demonstration Mean Time Between Failure(Expected Life) :
20,000 hours @ Tcase 70℃,50,000 hours @ Tcase 55℃
PASS
SAFETY TEST
1
WITHSTAND VOLTAGE
I/P-O/P: 3.75
KVAC/min
EN 60950
2
3
ISOLATION RESISTANCE
LEAKAGE CURRENT
I/P-O/P:500VDC>100MΩ
<
0.25
mA / 240VAC
I/P-O/P: 4.2
Ta:25℃
I/P-O/P: 500
Ta:25℃
KVAC/min
I/P-O/P: 1.883
mA
NO DAMAGE
VDC
I/P-O/P:
>9999 MΩ
NO DAMAGE
I/P: 264 VAC
L-FG:
2.2
uA
EN 60950
O/P:NO LOAD
Ta:25℃
N-FG:
2.2
uA
TEST ITEM
SPECICATION
TEST CONDITION
RESULT
HARMONIC
EN61000-3-2
I/P: 220V/230V/240V AC 50HZ
PASS
CLASS A
O/P:100%/75%/50%/25% LOAD
Ta:25℃
EN55015
I/P:230 VAC (50HZ) /115V(60HZ)
PASS
O/P:FULL/50% LOAD
Ta:25℃
Test by certified Lab
PASS
PASS
PASS
E.M.C TEST
NO
1
2
CONDUCTION
VERDICT
PASS
PASS
Model: APC-12-350
Test Report
3/5
APC-12 series
12W Single Output Switching Power Supply
3
4
5
6
RADIATION
E.S.D
E.F.T
SURGE
EN55015
I/P: 230 VAC (50HZ)/115V(60HZ)
PASS
O/P:FULL LOAD
Ta:25℃
Test by certified Lab
EN61000-4-2
I/P: 230 VAC/50HZ
CRITERIA A
LIGHT INDUSTRY
AIR:8KV / Contact:4KV
O/P:FULL LOAD
Ta:25℃
EN61000-4-4
I/P: 230 VAC/50HZ
LIGHT INDUSTRY
INPUT: 1KV
O/P:FULL LOAD
Ta:25℃
EN61000-4-5
I/P: 230 VAC/50HZ
LIGHT INDUSTRY
O/P:FULL LOAD
Ta:25℃
L-N :2KV
7
PASS
PASS
CRITERIA A
PASS
CRITERIA A
PASS
Test by certified Lab & Test Report Prepare
COMPONENT STRESS TEST
NO
1
TEST ITEM
SPECICATION
Power Transistor
U1
( D to S) or (C to E) Peak Voltage
TEST CONDITION
Rated
SD4843
RESULT
VERDICT
I/P:High-Line +3V =267 V
: 650 V
11 A
O/P: (1)Full Load input on/off
(1)512V/1.42A
(2)Output Short
(2)460V/1.29A
(3)Dynamic Load Full Load/
(3)516V/520mA
Min. Load 90%Duty/3KHz
(4)540V/810mA
(4)Dynamic Load 50% Load/
Min. Load 50%Duty/120Hz
I/P:Low-Line -3V = 87 V
PASS
O/P: (1)Full Load input on/off
(1)274V/660mA
(2)Output Short
(2)158V/590mA
(3)Dynamic Load Full Load/
(3)242V/430mA
Min. Load 90%Duty/3KHz
(4)286V/880mA
(4)Dynamic Load 50% Load/
Min. Load 50%Duty/120Hz
Ta:25℃
2
Diode Peak Voltage
D10
HER306
Rated
:
I/P:High-Line +3V = 267
600 V
3A
V
O/P: (1)Full Load input on/off
(1)237 V
(2)Output Short
(2) 203V
(3)Dynamic Load Full Load/
(3) 234V
Min. Load 90%Duty/3KHz
(4) 238V
(4)Dynamic Load 50% Load/
Min. Load 50%Duty/120Hz
I/P:Low-Line -3V = 87
V
O/P: (1)Full Load input on/off
PASS
(1) 39.6V
(2)Output Short
(2) 41.6V
(3)Dynamic Load Full Load/
(3) 36.0V
Min. Load 90%Duty/3KHz
(4)36.4 V
(4)Dynamic Load 50% Load/
Min. Load 50%Duty/120Hz
Ta:25℃
Model: APC-12-350
Test Report
4/5
APC-12 series
12W Single Output Switching Power Supply
3
Input Capacitor Voltage
C5
Rated
I/P:High-Line +3V =267
CAPXON : 12 u / 400 V
105℃/
KM Series
V
O/P: (1)Full Load input on/off
(1) 398
(2)Min load input on /off
(2) 390
(3)Burn-IN
(3) 388
1Hour
V
V
PASS
V
Ta:25℃
4
Control IC Voltage Test
U1
Rated
SD4843
I/P:High-Line +3V = 267
:
21 V
V
O/P:(1).Output Short
(1) 16.2V
(2).O.L.P
(2) 16.2V
(3).O.V.P.
(3) 16.2V
(4).NO LOAD LOW LINE
(4) 12.3V
PASS
Ta:25℃
2007/11/26 A50-G058
DATE
SAMPLE
TEST RESULT
TESTER
APPROVAL
2010/11/1
RD SAMPLE
PASS
SKY
HOWAY
2011/6/10
PRODUCT SAMPLE
(W1106A171)
PASS
SKY
HOWAY
2011/7/28
PRODUCT SAMPLE
(W1107G151)
PASS
SKY
HOWAY
Model: APC-12-350
Test Report
5/5