NED-50 series 50W Dual Output Switching Power Supply MODEL:NED-50A OUTPUT FUNCTION TEST NO 1 2 TEST ITEM SPECICATION TEST CONDITION RIPPLE & NOISE V1:80 mVp-p (Max ) I/P: 230VAC V1: 10 mVp-p (Max ) V2:120 mVp-p (Max ) O/P:FULL LOAD Ta:25℃ V2: 10 mVp-p (Max ) OUTPUT VOLTAGE CH1: 4.75 V~ 5.5 V ADJUST RANGE RESULT VERDICT I/P: 230 VAC 4.55 V~ 5.89 V/ 230 VAC I/P: 115 VAC 4.55 V~ 5.89 V/ 115 VAC P O/P:MIN LOAD Ta:25℃ 3 4 5 6 OUTPUT VOLTAGE V1: 2 %~ -2 % (Max) I/P: 115 VAC / 264 VAC V1: 0.5 %~ -0.5 % TOLERANCE V2: 6 %~ -6 % (Max) O/P:FULL/ 40% LOAD Ta:25℃ V2: 1.8 %~ -1.8 % V1: 0.5 %~ -0.5 % (Max) I/P: 115 VAC ~ 264 VAC V1: 0.12 %~ -0.12 % V2: 1 %~ -1 % (Max) O/P:FULL LOAD Ta:25℃ V2: 0.3 %~ -0.3 % V1: 1.5 %~ -1.5 % (Max) I/P: 230 VAC V1: 0.5 %~ -0.5 % V2: 3 %~ -3 % (Max) O/P:FULL ~MIN LOAD Ta:25℃ V2: 0.3 %~ -0.3 % V1: 1.5 %~ -1.5 % (Max) I/P: 230 VAC V1: 0.15 %~ -0.15 % V2: 3 %~ -3 % (Max) O/P: Testing O/P 60%LOAD V2: 1.4 %~ -1.4 % LINE REGULATION LOAD REGULATION CROSS REGULATION P P P P Other O/P 40%LOAD P Change Ta:25℃ 7 SET UP TIME 230VAC: 115 VAC: 500 1200 ms (Max) I/P: 230 VAC 230VAC/ 173 ms ms (Max) I/P: 115 VAC 115VAC/ 501 ms O/P:FULL LOAD Ta:25℃ 8 RISE TIME 230VAC: 30 ms (Max) I/P: 230 VAC 230VAC/ 5 ms 115VAC: 30 ms (Max) I/P: 115 VAC 115VAC/ 7 ms O/P:FULL LOAD Ta:25℃ 9 HOLD UP TIME 230VAC: 50 ms (TYP) I/P: 230 VAC 230VAC/ 76 ms 115VAC: 10 ms (TYP) I/P: 115 VAC 115VAC/ 14 ms TEST: <5 % O/P:FULL LOAD Ta:25℃ 10 OVER/UNDERSHOOT TEST I/P: 230 VAC < +5% O/P:FULL LOAD Ta:25℃ 11 DYNAMIC LOAD V1: 1000 mVp-p I/P: 230 VAC P P P P 59 mVp-p O/P:FULL /Min LOAD P 90%DUTY/1KHZ Ta:25℃ Model: NED-50A Test Report 1 / 5 NED-50 series 50W Dual Output Switching Power Supply INPUT FUNCTION TEST N O TEST ITEM SPECICATION TEST CONDITION RESULT 1 INPUT VOLTAGE RANGE 85VAC~264 VAC I/P:TESTING 71 V~264V VERDICT O/P:FULL LOAD Ta:25℃ I/P: TEST: OK LOW-LINE-3V=82 V P HIGH-LINE+15%=300 V O/P:FULL/MIN LOAD ON: 30 Sec . OFF: 30 Sec 10MIN ( AC POWER ON/OFF NO DAMAGE ) 2 3 INPUT FREQUENCY RANGE 47HZ ~63 HZ I/P: 85 VAC ~ 264 VAC NO DAMAGE OSC O/P:FULL~MIN LOAD Ta:25℃ 79 % (TYP) EFFICIENCY I/P: 230 VAC TEST: OK P 79.5 % O/P:FULL LOAD Ta:25℃ 4 INPUT CURRENT P 230V/ 0.65 A (TYP) I/P: 230 VAC I= 0.62 A/ 230 VAC 115V/ 1.1 A (TYP) I/P: 115 VAC I= 1 A/ 115 VAC I= 43 A/ 230 VAC P O/P:FULL LOAD Ta:25℃ 5 INRUSH CURRENT 230V/ 45 A (TYP) I/P: 230 VAC I/P: 115 VAC 6 LEAKAGE CURRENT < 2 P O/P:FULL LOAD Ta:25℃ COLD START mA / 240 VAC I/P: 254 VAC L-FG: 0.2 mA O/P:Min LOAD Ta:25℃ N-FG: 0.2 mA P PROTECTION FUNCTION TEST NO 1 TEST ITEM OVER LOAD PROTECTION SPECICATION 110 %~ 150 % TEST CONDITION I/P: 230 VAC I/P: 115 VAC O/P:TESTING Ta:25℃ 2 OVER VOLTAGE PROTECTION CH1: 5.75V~6.75 V I/P: 230 VAC I/P: 115 VAC 3 SHORT PROTECTION RESULT VERDICT 131 %/ 230 VAC 122 %/ 115 VAC Hiccup Mode P 6.3 V/ 230 VAC 6.3 V/ 115 VAC O/P:MIN LOAD Ta:25℃ Shunt down Re- power ON SHORT EVERY OUTPUT I/P: 264 VAC NO DAMAGE 1 HOUR NO DAMAGE O/P:FULL LOAD Ta:25℃ Hiccup Mode P P Model: NED-50A Test Report 2 / 5 NED-50 series 50W Dual Output Switching Power Supply ENVIRONMENT TEST NO 1 TEST ITEM SPECICATION TEMPERATURE RISE TEST MODEL:NED-50A TEST CONDITION RESULT VERDICT 1. ROOM AMBIENT BURN-IN:1.5 HRS I/P: 230VAC O/P: FULL LOAD Ta= 32.1℃ 2. HIGH AMBIENT BURN-IN:1.5 HRS I/P: 230VAC O/P: FULL LOAD Ta= 50.8℃ Position 1 R5 68K/2W R/MO 2 C5 100U/400V CAPX 85℃ 63.0℃ 77.1℃ 3 BD1 D3SB60 4A/600V SHI 71.4℃ 84.1℃ 4 LF1 LF-133 59.4℃ 73.4℃ 5 C205 470U/25V CAPX 105℃ GL 67.8℃ 82.5℃ 6 D1 HER306 3A/600V REC 85.1℃ 99.3℃ 7 U1 1203P 72.0℃ 87.6℃ 8 Q1 K2628 6A/600V 72.6℃ 91.2℃ 9 D200 SF10SC6 10A/60V SHI 65.9℃ 81.5℃ 10 T1 COIL TF-1015 86.4℃ 100.3℃ 11 D100 MBR1545CT 15A/45V 68.7℃ 84.8℃ 12 C105 2200U/10V CAPX 105℃ 72.6℃ 87.7℃ R105 33Ω/2W R/MO 100.3℃ 117.2℃ 14 ℃ ℃ 15 ℃ ℃ 13 2 OVER LOAD BURN-IN TEST P/N ROOM AMBIENT HIGH AMBIENT Ta= 32.1 ℃ Ta= 50.8 ℃ 91.5℃ 102.1℃ NO NO DAMAGE I/P: 230 VAC O/P: 131﹪LOAD 1 HOUR ( MIN ) P TEST:OK P Ta:25℃ 3 LOW TEMPERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/P: 230 VAC O/P: 100 ﹪LOAD TEST:OK P Ta= -20℃ 4 AFTER 12 HOURS I/P: 272 VAC HIGH TEMPERATURE IN CHAMBER ON CONTROL 45 ℃ O/P:FULL LOAD Ta= 45 ℃ NO DAMAGE + 0.03 %(0~50℃) HUMIDITY= HIGH VOLTAGE TURN ON TEST 5 TEMPERATURE VIBRATION TEST P 95 %R.H I/P: 230 VAC + 0.01%(0~50℃) P O/P:FULL LOAD COEFFICIENT 6 TEST:OK HIGH HUMIDITY 1 Carton & 1 Set TEST:OK (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle P (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) Ta:25℃ Model: NED-50A Test Report 3 / 5 NED-50 series 50W Dual Output Switching Power Supply SAFETY TEST NO 1 2 3 4 TEST ITEM SPECICATION TEST CONDITION RESULT WITHSTAND VOLTAGE I/P-O/P: 3 KVAC/min I/P-O/P: 3.6 KVAC/min I/P-O/P: 3 mA I/P-FG: 1.5 KVAC/min I/P-FG: 1.8 KVAC/min I/P-FG: 2.11 mA O/P-FG: 0.5 KVAC/min O/P-FG: 0.6 KVAC/min Ta:25℃ O/P-FG: 1.62 mA I/P-O/P:500VDC>100MΩ I/P-O/P: 500 VDC I/P-O/P: 3 GΩ I/P-FG: 500VDC>100MΩ I/P-FG: 500 VDC O/P-FG:500VDC>100MΩ O/P-FG: 500 Ta:25℃ VDC I/P-FG: 4 GΩ O/P-FG: 5 GΩ ISOLATION RESISTANCE GROUNDING CONTINUITY FG(PE) TO CHASSIS APPROVAL OR TRACE < 100 mΩ TUV: Certificate NO : VERDICT P NO DAMAGE P NO DAMAGE 40 A / 2min Ta:25℃ 5 mΩ P P UL: File NO :E183223 E.M.C TEST NO 1 2 3 4 5 TEST ITEM SPECICATION TEST CONDITION RESULT HARMONIC EN61000-3-2 I/P: 230 VAC/50HZ PASS CLASS A O/P:FULL LOAD Ta:25℃ EN55022 I/P: 230 VAC (50HZ) PASS CLASS B O/P:FULL/50% LOAD Ta:25℃ Test by certified Lab CONDUCTION RADIATION E.S.D E.F.T 6 SURGE P EN55022 I/P: 230 VAC (50HZ) PASS CLASS B O/P:FULL LOAD Ta:25℃ Test by certified Lab EN61000-4-2 I/P: 230 VAC/50HZ CRITERIA A LIGHT INDUSTRY AIR:8KV / Contact:4KV O/P:FULL LOAD Ta:25℃ EN61000-4-4 I/P: 230 VAC/50HZ LIGHT INDUSTRY O/P:FULL LOAD Ta:25℃ INPUT: 1KV IEC61000-4-5 I/P: 230 VAC/50HZ LIGHT INDUSTRY O/P:FULL LOAD Ta:25℃ L-N :1KV VERDICT P P P CRITERIA A P CRITERIA A P L,N-PE:2KV 7 Test by certified Lab & Test Report Prepare M.T.B.F & LIFE CYCLE CALCULATION NO 1 TEST ITEM SPECICATION CAPACITOR SUPPOSE C 105 IS THE MOST CRITICAL COMPONENT I/P: 230VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME= 82425 HRS LIFE CYCLE I/P: 230VAC 2 MTBF TEST CONDITION O/P:FULL LOAD Ta= 45 ℃ RESULT VERDICT P LIFE TIME= 26461 HRS MIL-HDBK-217F NOTICES2 PARTS COUNT P TOTAL FAILURE RATE: 402.7K HRS Model: NED-50A Test Report 4 / 5 NED-50 series 50W Dual Output Switching Power Supply COMPONENT STRESS TEST NO 1 TEST ITEM SPECICATION TEST CONDITION RESULT Power Transistor Q1 I/P:High-Line +3V = 267 V (1) 550 V ( D to S) or (C to E) Peak Voltage K3562 : 600V O/P: (1)Full Load Turn on (2) 548 V (3) 554 V Rated 6A (2) Full Load VERDICT P (3)Output Short Ta:25℃ 2 Diode Peak Voltage D100 Rated I/P:High-Line +3V = 267 V (1) 34.4 V MBR1545CT : 45V 15A O/P: (1)Full Load Turn on (2) 39.6 V (3) 34.4 V (1) 45.8 V (2) 51 V (3) 46 V (2) Full Load (3)Output Short Ta:25℃ D200 Rated SF10SC6 : 60V 10A 3 Clamp Diode Peak Voltage D1 Rated STTA406 : 600 V 3A I/P:High-Line +3V = 267 V (1) 516 V O/P: (1)Full Load (2) 518 V P P (2) Dynamic Load 90%Duty/1KHz Ta:25℃ 4 Input Capacitor Voltage C5 Rated : 100 u / 400 V/ 85℃ I/P:High-Line +3V = 267 V (1) 386 V O/P: (1)Full Load Turn on /Off (2) 386 V (2) Min load Turn on /Off (3) 382 V (3)Full Load /Min load Change (4) 378 V P (4)Burn in 1hour Ta:25℃ 5 Control IC Voltage Test U 1 Rated I/P:High-Line +3V = 267 V (1) 13.2 V 1203 : 18V O/P: (1)Full Load Turn on /Off (2) 13.2 V (2) Min load Turn on /Off (3) 10.8 V P (3)Full Load /Min load Change Ta:25℃ DATE SAMPLE TEST RESULT TESTER APPROVAL 2005/3/21 RD SAMPLE PASS VINCENT TSENG MAX LIN 2005/7/8 PRODUCT SAMPLE PASS VINCENT TSENG MAX LIN 2003/12/12 Model: NED-50A A50-F023 Test Report 5 / 5