Technical Specification 400 W Triple Vout Series Industrial Grade AC/DC Power Supply With PFC 85-264 Vrms 12/24/36/48 V 400 W 500 W Up to 91 % Input Voltage Semi-Regulated Output Output Continuous Output Transient Full Load Efficiency Includes 5 V (10 W) and 12 V (50 W) “Always On” Standby Power Outputs 400 W Open Frame Configurations •400 W Encased or Open Frame •800 W Encased Flat or Stacked •1200 W Encased Flat or Stacked 400 W Encased 1200 W Encased Stacked 800 W Encased Flat 400 W Triple Vout Series Features • • • • • • • • High efficiency (91% for 48 VOUT Model at 400 W) Universal input voltage range Semi-regulated output for bus stability Parallel operation supported Integral fan cooling with speed control Active PFC; EN61000-3-2 compliant Low leakage; EN60601-1 compliant Low noise; EN55011 / EN55022 Class B compliant Product # AQ0400IUxT Series Phone 1-888-567-9596 • Over–current, over–voltage, and over–temp protection • DC Power Good / AC Power Good signals • Remote enable input • Fan status output / Fan enable input • Small size: 3" x 5" x 1.45" (open frame) • RoHS 6/6 compliant • 5 V (250 mW) standby output www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 1 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification ACuQor 400W Triple Vout Series ELECTRICAL CHARACTERISTICS All specifications typical with TA = 25 °C, unless otherwise specified. MAIN OUTPUT SPECIFICATIONS Output power (continuous) 85-132/170-264 Vrms (5 s transient) 85-132/170-264 Vrms 132-170 Vrms 400 W (Note 1) 500 W (Note 1) See Figure 10 Nominal DC output voltage (at 250W) (Semi-regulated) 12 Vout (model 1T) 24 Vout (model 2T) 36 Vout (model 3T) 48 Vout (model 4T) Efficiency 12 Vout, 115 Vrms, 400 W (see figs. 1, 3, 5, 7) 48 Vout, 115 Vrms, 400 W (see Note 1) 12 Vout, 230 Vrms, 400 W 48 Vout, 230 Vrms, 400 W Hold-up time (to -20%) 12 Vout (see Note 1) 24 / 36 / 48 Vout Maximum load capacitance 12 Vout 24 Vout 36 Vout 48 Vout Output ripple voltage Switching frequency (20 MHz BW) Twice line frequency (at 300W) Turn-on delay Transient response Iout steps from 50-75% At 0.2 A/µs Overvoltage protection Short circuit protection Total regulation 12V_STANDBY cross-reg. 5V_STANDBY cross-reg. Thermal protection REMOTE_ENABLE Cyclic restart Cyclic operation Over line, load and temperature ΔVout caused by 50 W step ΔVout caused by 10 W step Automatic recovery Input Low Voltage Input High Voltage 12V_STANDBY OUTPUT SPECIFICATIONS Output power 85-264 Vrms Nominal DC output voltage Semi-regulated Total regulation Over line, load and temperature Main output cross-reg. Δ12V_STANDBY caused by Δ350W on main output Output ripple Switching frequency (20 MHz BW) Twice line frequency Output current Continuous Short circuit protection Cyclic operation Maximum load capacitance 12.4 V 25 V 37.5 V 50 V 88% typ. 90% typ. 89% typ. 91% typ. 16 ms @ 400 W 20 ms @ 400 W 16,000 µF 8,000 µF 4,000 µF 2,000 µF 0.5% p-p 5.0% p-p 2 s max. 3% typ / 6% max. dev. 100 ms recovery 110-120% 115% rated Iout ±6.0% 0.5% 0.1% +125 ºC (PCB Temp) 0.45 V (max) 4.15 V (min) 5V_STANDBY OUTPUT SPECIFICATIONS Output power 85-264 Vrms Nominal DC output voltage Fully regulated Total regulation Over line, load and temperature Output current Continuous Short circuit protection Cyclic operation Maximum load capacitance INPUT SPECIFICATIONS AC input voltage Universal range Input frequency Input current (see Note 1) Power factor 115 Vrms @ 400 W 230 Vrms @ 400 W Input surge current Internal input fuses 264 Vrms (cold start) Both AC lines Product # AQ0400IUxT Series Phone 1-888-567-9596 50 W 12.4 V ±6.0% 400 mV 10 mV 0.45 Vrms 4.2 A 5.0 A 2,000 uF 10 W 5.0 V ±5.0% 2.0 A 2.5 A 1,000 uF 85-264 Vrms 47-63 Hz 4 Arms 2 Arms >0.98 40 A max. 6.3 A GENERAL SPECIFICATIONS Fundamental ripple freq. Input 500 kHz Output 250 kHz Audible noise Fan speed varies with temp. 39 dBA @ 1 m max. Weight (EA \ EC) 343 g (12.1 oz) \ 446 g (15.7 oz) (SC \ RC) 846 g (29.8 oz) \ 879 g (31 oz) (UC \ TC) 1224 g (43.2 oz) \ 1298 g (45.8 oz) MTBF MIL-217 343.6 kHours Demonstrated TBD kHours ISOLATION SPECIFICATIONS Isolation voltage Input to output 3000 Vrms Input to ground 1500 Vrms Output to ground 500 Vrms Insulation resistance Output to ground 10 MΩ min. Leakage currents See Note 2 ENVIRONMENTAL CHARACTERISTICS Thermal performance Operating ambient (see Figure 9) Non-operating ambient Relative humidity Non-condensing Altitude Operating Non-operating Random vibration 5-500 Hz Shock Half-sine, 10 ms, 3 axes EMC CHARACTERISTICS Conducted emissions EN55011 and EN55022, FCC part15 Line frequency harmonics EN61000-3-2 Voltage fluctuations EN61000-3-3 ESD air EN61000-4-2 ESD contact EN61000-4-2 Radiated immunity EN61000-4-3 Fast transients EN61000-4-4 Line surge immunity EN61000-4-5 Conducted immunity EN61000-4-6 Power freq. mag. field EN61000-4-8 Voltage dip immunity EN61000-4-11 0 ºC to +70 ºC -40 ºC to +85 ºC 5-95% RH 10,000 ft max. 30,000 ft max. 0.03 g2/Hz 20 g peak Level B Class A Clause 5b Level 3 Level 3 Level 3 Level 3 Level 3 Level 3 3 A/m Perf Criteria A, A, B <5% UT 10 ms, 70% UT 500 ms, 40% UT 100 ms SAFETY AGENCY CERTIFICATIONS (pending) All certification marks appear on individual unit labels. UL60950 IEC/EN 60950 CE Marked cUL CSA Standards NOTES: 1. Main output power rating always includes 5 V and 12 V standby outputs. 2. Leakage currents: AC Leakage Current from Input to Earth Normal Open Neutral Condition Fault AC Line Connection 240 V L-N, 1 phase ACuQor Typical at 110% nominal input 208 V L-L, 120 V L-N, 1 of 3 phases voltage 60 Hz 240 V L-N-L, 120 V L-N, split phase www.synqor.com Doc.# 005-005053 Rev. A 400 µA 800 µA 200 µA 400 µA 200 µA 400 µA 09/08/08 Page 2 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification EFFICIENCY, DERATING, AND VOUT DROOP CURVES 100 14.0 95 13.5 13.0 Output Voltage (V) Efficiency (%) 90 85 80 75 12.5 12.0 11.5 11.0 115 Vrms 70 10.5 230 Vrms 65 10.0 0 100 200 300 400 500 0 4 8 12 Figure 1: 12 VOUT efficiency curves. 20 24 28 32 36 12 14 16 18 Figure 2: 12 VOUT droop characteristic. 100 28 95 27 26 Output Voltage (V) 90 Efficiency (%) 16 Output Load (A) Output Power (W) 85 80 75 25 24 23 22 115 Vrms 70 21 230 Vrms 65 20 0 100 200 300 400 500 0 2 4 6 Figure 3: 24 VOUT efficiency curves. 10 Figure 4: 24 VOUT droop characteristic. 42 100 95 40 Output Voltage (V) 90 Efficiency (%) 8 Output Load (A) Output Power (W) 85 80 75 115 Vrms 70 38 36 34 32 230 Vrms 65 30 0 100 200 300 400 500 0 Figure 5: 36 VOUT efficiency curves. Product # AQ0400IUxT Series Phone 1-888-567-9596 2 4 6 8 10 12 Output Load (A) Output Power (W) Figure 6: 36 VOUT droop characteristic. www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 3 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification EFFICIENCY, DERATING, AND VOUT DROOP CURVES 100 54 95 52 Output Voltage (V) Efficiency (%) 90 85 80 75 115 Vrms 70 50 48 46 44 230 Vrms 65 42 0 100 200 300 400 500 0 1 2 3 Output Power (W) 4 5 6 7 8 9 Output Load (A) Figure 8: 48 VOUT droop characteristic. Figure 7: 48 VOUT efficiency curves. 600 500 500 400 Power (W) Power (W) 400 300 200 300 200 24 / 36 / 48 V with Fan Enabled Transient 12 V with Fan Enabled 100 100 24 / 36 / 48 V with Fan Disabled Continuous 12 V with Fan Disabled 0 0 85 0 10 20 30 40 50 60 70 Product # AQ0400IUxT Series Phone 1-888-567-9596 170 264 Input AC Voltage (VRMS) Ambient Temperature (ºC) Figure 9: Continuous power derating curve in natural convection. 132 80 Figure 10: Rated output power vs Input AC Voltage. www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 4 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification MECHANICAL DRAWINGS (1 Module Open Frame Version — E Package Type) Front Back Top Bottom Right MECHANICAL DRAWINGS (1 Module Encased Version — E Package Type) Top Right Bottom Front Back NOTES (applies to all mechanicals) 1)Recommendedscrewtighteningtorqueof6in.lbs 2)Undimensionedcomponentsareshownforvisualreferenceonly 3)Alldimensionsininches[mm] Tolerances: x.xxin±0.02 x.xxxin±0.010 Product # AQ0400IUxT Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 5 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification MECHANICAL DRAWINGS (2 Modules Flat Version — R Package Type) Product # AQ0400IUxT Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 6 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification MECHANICAL DRAWINGS (2 Modules Stacked Version — S Package Type) Product # AQ0400IUxT Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 7 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification MECHANICAL DRAWINGS (3 Modules Flat Version — T Package Type) Product # AQ0400IUxT Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 8 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification MECHANICAL DRAWINGS (3 Modules Stacked Version — U Package Type) Product # AQ0400IUxT Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 9 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification CONNECTOR DETAILS OUTPUT CONNECTOR PINOUT (top side) Pin 1 FAN_GOOD Open collector with internal 5V pullup. See Figure A. Pulsed low on fan failure, 100ms, 50% duty. Short to VOUT(-) to disable fan. Pin 2 AC_POWER_GOOD Open collector with internal 5V pullup. See Figure B. Pulled low on AC power dropout. Pin 3 DC_POWER_GOOD Open collector with internal 5V pullup. See Figure B. Pulled low during startup ramp and within 5 ºC of temperature shutdown threshold. Pin 4 5V_STANDBY 5 V @ 10 W available whenever AC power is applied. Pin 5 VOUT(+) Positive Output Voltage. Pin 6 VOUT(+) Positive Output Voltage. Pin 7 VOUT(+) Positive Output Voltage. Pin 8 VOUT(+) Positive Output Voltage. Pin 9 Reserved Reserved for future use. Pin 10 Reserved Reserved for future use. Pin 11 REMOTE_ENABLE Logic input. See Figure C. Pull high to enable main output. Figure A: Fan status output / Fan enable input interface circuitry. 5V_STANDBY 1N4148 5k 10 Ohms AC_POWER_GOOD or DC_POWER_GOOD Pin 12 12V_STANDBY 12 V @ 50 W available whenever AC power is applied. Pin 13 VOUT(–) Negative Output Voltage. Pin 14 VOUT(–) Negative Output Voltage. Pin 15 VOUT(–) Negative Output Voltage. Pin 16 VOUT(–) Negative Output Voltage. 2N3904 VOUT(-) Figure B: Power good interface circuitry. 12 V OUTPUT CONNECTOR PINOUT (bottom side) Pin 1 VOUT(+) Positive Output Voltage. Pin 2 VOUT(+) Positive Output Voltage. Pin 3 VOUT(+) Positive Output Voltage. Pin 4 VOUT(+) Positive Output Voltage. Pin 5 VOUT(–) Negative Output Voltage. Pin 6 VOUT(–) Negative Output Voltage. Pin 7 VOUT(–) Negative Output Voltage. Pin 8 VOUT(–) Negative Output Voltage From AC/DC Monitor Circuitry 0.1 µF 5V_STANDBY 5V_STANDBY REMOTE_ENABLE 10 Ohms 5k 0.1 µF To Enable Circuitry 10k VOUT(-) Figure C: Remote enable interface circuitry. MATING CONNECTORS Connector Type Contact OUTPUT (16 pins) Molex 430251600 Molex 430300008* INDIVIDUAL INPUT CONNECTOR PINOUT 12V_OUTPUT (8 pins) Molex 436450800 Molex 430300008* Pin 1 Ground INPUT JST VHR-5N JST SVH-41T-P1.1 Pin 3 AC Neutral Pin 5 AC Line Product # AQ0400IUxT Series * Each contact rated for a maximum of 5.5 A. Phone 1-888-567-9596 www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 10 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification PARALLEL OPERATION - MULTIPLE UNITS Chassis configurations for Parallel Units ACuQor units are available either open-frame or pre-mounted at the factory. Up to 3 units can be mounted into a chassis, in either side-by-side or stacked configurations. For a complete list of options, see the “Part Numbering System” table on the last page, under “Package Type”, along with the Mechanical Drawings pages. Only side-by-side configurations can be populated with 500W units, since each includes a thermal pad underneath. Interconnection of Parallel Units ACuQor units mounted in 2 and 3 unit chassis are not connected together. This allows the physical routing and connectivity of the external wiring to be customized to each application. The following table summarizes the recommended wiring to operate multiple units in parallel: Specifications of Parallel Units As a rule, units wired in parallel behave the same as single units. Any specification will remain unchanged that is expressed in units of voltage, time, frequency, or efficiency. Specifications expressed in terms of power, current, or capacitance, should be scaled by the number of units wired in parallel. ACuQor units are individually calibrated at the factory, so that the output voltage vs. output current characteristic is always consistent (see Vout droop characteristic figures). As such, multiple units will share output current accurately. Full current is guaranteed from a bank of multiple units wired in parallel. Output Connector Signal Suggested Connection Behavior with Multiple Units REMOTE_ENABLE Wire in parallel Inputs activated simultaneously FAN_GOOD “ Wired-OR outputs – can be pulled low by any unit during an abnormal condition. AC_POWER_GOOD “ “ DC_POWER_GOOD “ “ VOUT(+), VOUT(-) “ Built-in droop characteristic ensures graceful current sharing. 12V_STANDBY* “ “ 5V_STANDBY Do not wire in parallel Fully regulated characteristic does not support current sharing. If placed in parallel, only the output with the highest set-point will drive current. *Note: Triple output models only. Product # AQ0400IUxT Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 11 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification INSTALLATION INSTRUCTIONS General:ACuQorAC/DCpowersuppliesareintendedforuse as components in industrial equipment. ACuQor units must be properly installed within end use equipment before they can be safely applied as described in this document. The suitability of theACuQor/equipmentcombinationmustbeverifiedthroughend productinvestigation. Mounting:RefertotheMechanicalDrawingssection.ACuQor unitsareprovidedwiththreadedstainless-steelstand-offsorinserts formounting.Thismountinghardwareisinternallyconnectedto the input connector protective-earth terminal for functional-earth EMCcontrol.Anyorientation(vertical,horizontal,etc.)maybe used.Adequateairspaceshouldbeprovidedoverthefanintake (top) and exhaust (sides) to allow for exchange of cooling air. ACuQorisdesignedforapollutiondegree2environment.The suitabilityoftheenclosedACuQormechanicalassembliesmustbe verifiedthroughendproductinvestigation. Encased models: A minimum of 5 mm electrical clearance shouldbeallowedfromtheconnectorendsofencasedmodels. Input: Refer to the Connector Details section for input connectorwiring.ACuQorproductsrequireasinglephaseACpower sourceof100-240V50/60Hznominal.Refertonameplatelabel for input current ratings. A protective-earth connection is also required. Minimum wire size of 18 AWG (0.8mm2) is recommended.BothsidesoftheAClineareinternallyfused(seetable forspecificmodels).Thesefusesarenotuserreplaceable. MODEL AQ0300 AQ0400 AQ0500 Input Fuses (in Both AC Lines) Littelfuse6.3A250V21606.3XEP Littelfuse6.3A250V21606.3XEP Littelfuse10.0A250V216010XEP Product # AQ0400IUxT Series Phone 1-888-567-9596 Output: Refer to the Connector Details section for output connector wiring and signal I/O functionality. Refer to nameplate label for output current ratings. Main DC output (Vout+, Vout-) pins should use 20 AWG (0.5mm2) wire size. Individual main outputpinsshouldnotbeloadedtomorethan5.5A.Forcurrents greaterthan5.5A,multiplemainoutputpins/wiresmustbeused inparallel.AllsignalI/OpinsarereferencedtoVout-. EMC:ACuQorproductshavebeentestedtotheEMCspecificationslistedintheElectricalCharacteristicssection.However,end useequipmentmustbetestedtoverifyEMCcompliance. Hipot Testing: ACuQor products are rated for Hipot testing levels of 1500 Vac input to protective-earth, 500 Vac output to protective-earth, and 3000 Vac input to output. When performing the 3000 Vac input to output test, the test voltage must be balanced evenly 1500 Vac input and output to protective-earth. Two oppositely phased test voltage sources or a single test voltagesourcewithexternalbalancingimpedances(capacitors)may beusedtopreventoverstressinginputoroutputtoprotective-earth insulationperIEC/ENC60950-1. Fuses Total 2 2 2 www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 12 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial Technical Specification PART NUMBERING SYSTEM The part numbering system for SynQor’s ACuQor AC/DC power supplies follows the format shown in the table below. Notallcombinationsmakevalidpartnumbers,pleasecontactSynQorforavailability. Family AQ ACuQor series of ac-dc semi-regulated output power supplies Output Power 0300: 300 W 0400: 400 W 0500: 500 W 0600: 600 W (2 x 300 W) 0800: 800 W (2 x 400 W) 0900: 900 W (3 x 300 W) 1000: 1000 W (2 x 500 W) 1200: 1200 W (3 x 400 W) 1500: 1500 W (3 x 500 W) Grade I: industrial Range U: universal (85-264 VRMS) Output Voltage Package Type (xx=Standard; xT=Triple) (Correlates to Output Power) 12: 12 V 1T: 12 V / 5 & 12 V STBY 24: 24 V 2T: 24 V / 5 & 12 V STBY 36: 36 V 3T: 36 V / 5 & 12 V STBY 48: 48 V 4T: 48 V / 5 & 12 V STBY E: 1 unit (3" x 5") R: 2 units; flat S: 2 units; stacked T: 3 units; flat U: 3 units; stacked Thermal Design A: open frame C: encased Q: encased only Options Industrial Grade: IND: Industrial Example: AQ0400IU2TEAIND ACCESSORIES SynQoroffersaseriesofassembliesthatcanbeorderedaccordingtothetablebelow.Mechanicaldrawingsfortheseaccessoriesare availablefordownloadinpdfformatfromtheSynQorwebsite. Part Number Description AQ-CBL-INPUT1C Input mating cable with pre-stripped wire ends (36" long). AQ-CBL-OUT1C Output mating cable with pre-stripped wire ends (18" long). AQ-CBL-OUT1CD Same as AQ-CBL-OUT1C with an additional 8-pin connector. AQ-CBL-OUT2C AQ-CBL-OUT2CD AQ-INSUL1M AQ-EVAL-PRL3 Output mating cable with connectors on both ends (18" long). Same as AQ-CBL-OUT2C with an additional 8-pin connector. Single module bottom-side Mylar insulator for open frame mounting. Evaluation board for up to three paralleled modules. APPLICATION NOTES AvarietyofapplicationnotesandtechnicalwhitepaperscanbedownloadedinpdfformatfromtheSynQorwebsite. PATENTS SynQorholdsthefollowingpatents,oneormoreofwhichmightapplytothisproduct: 5,999,417 6,222,742 6,545,890 6,594,159 6,731,520 6,894,468 6,927,987 7,050,309 7,072,190 7,119,524 7,269,034 7,272,021 Contact SynQor for further information: Phone: TollFree: Fax: E-mail: Web: Address: 978-849-0600 888-567-9596 978-849-0602 [email protected] www.synqor.com 155SwansonRoad Boxborough,MA01719,USA Product # AQ0400IUxT Series Phone 1-888-567-9596 6,577,109 6,896,526 7,085,146 7,272,023 Warranty:SynQoroffersatwo(2)yearlimitedwarranty.CompletewarrantyinformationislistedonourwebsiteorisavailableuponrequestfromSynQor. Limitation on use: SynQor’s products are not authorized for use and should not be used, without the specific prior written approval of an authorized officer of SynQor makingspecificreferencehereto,inanylifesupportsystem,nuclearfacilityorapplication,aircraftcontrolapplicationoranyotherapplicationinwhichfailureoftheproduct couldreasonablyresultinharmtolife,propertyortheenvironment. InformationfurnishedbySynQorisbelievedtobeaccurateandreliable.However, noresponsibilityisassumedbySynQorforitsuse,norforanyinfringementsofpatents orotherrightsofthirdpartieswhichmayresultfromitsuse.Nolicenseisgrantedby implicationorotherwiseunderanypatentorpatentrightsofSynQor. www.synqor.com Doc.# 005-005053 Rev. A 09/08/08 Page 13