Y R A N I IM L E R P Technical Specification 500 W Single Vout Series Industrial Grade AC/DC Power Supply With PFC 85-264 Vrms 12/24/36/48 V 500 W 700 W Up to 90% Input Voltage Semi-Regulated Output Output Continuous Output Transient Full Load Efficiency 1500 W Encased 1000 W Encased Package Configurations Available Up to three units can be factory mounted into a chassis. The 500 W Single Vout Series can be configured as follows: 500 W Encased • 500 W (1 unit) •1000 W (2 units) •1500 W (3 units) 500 W Single Vout Series Features • • • • • • • High efficiency (90% for 48 VOUT Model at 500 W) Universal input voltage range Semi-regulated output for bus stability Parallel operation supported Integral fan cooling with speed control Active PFC; EN61000-3-2 compliant Low noise; EN55011 / EN55022 Class B compliant Product # AQ0500IUxx Series Phone 1-888-567-9596 • Over–current, over–voltage, and over–temp protection • DC Power Good / AC Power Good signals • Remote enable input • Fan status output / Fan enable input • Small size: 3.59" x 5.25" x 1.63" • RoHS 6/6 compliant • 5 V (250 mW) standby output www.synqor.com Doc.# 005-005054 Rev. 1 09/04/08 Page 1 Y R A IN M LI E R P Technical Specification AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 500 W Series Grade: Industrial ACuQor 500W Series ELECTRICAL CHARACTERISTICS All specifications typical with TA = 25 °C, unless otherwise specified. MAIN OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Output power (continuous) 85-132/170-264 Vrms (5 s transient) 85-132/170-264 Vrms 132-170 Vrms Nominal DC output 12 Vout voltage (at 250W) 24 Vout (Semi-regulated) 36 Vout 48 Vout Efficiency (see figs. 1, 3, 5, 7) Hold-up time (to -20%) 12 48 12 48 12 24 Maximum load capacitance 12 24 36 48 Output ripple voltage Vout, Vout, Vout, Vout, 115 115 230 230 Vrms, Vrms, Vrms, Vrms, 500 500 500 500 500 W 700 W See Figures 11, 12 12.4 V 25 V 37.5 V 50 V W W W W 86% 89% 88% 90% Vout / 36 / 48 Vout Vout Vout Vout Vout typ. typ. typ. typ. 12 ms @ 500 W 16 ms @ 500 W 16,000 µF 8,000 µF 4,000 µF 2,000 µF Switching frequency (20 MHz BW) Twice line frequency (at 300W) 0.5% p-p 5.0% p-p Turn-on delay 2 s max. Transient response Iout steps from 50-75% At 0.2 A/µs Overvoltage protection Cyclic restart Short circuit protection Cyclic operation Total regulation Over line, load and temperature 3% typ / 6% max. dev. 100 ms recovery 110-120% 115% rated Iout Fundamental ripple freq. Audible noise Input Output Fan speed varies with temp. 500 kHz 250 kHz 39 dBA @ 1 m max. Weight (EQ) (RQ) (TQ) MTBF 540 g (19.1 oz) 1068 g (37.7 oz) 1582 g (55.8 oz) 343.6 kHours TBD kHours MIL-217 Demonstrated ISOLATION SPECIFICATIONS Isolation voltage Insulation resistance Input to output Input to ground Output to ground Output to ground 3000 Vrms 1500 Vrms 500 Vrms 10 MΩ min. Leakage currents See Note 2 ENVIRONMENTAL CHARACTERISTICS Thermal performance Relative humidity Altitude Operating ambient (see Figure 9) Non-operating ambient Non-condensing Random vibration Operating Non-operating 5-500 Hz Shock Half-sine, 10 ms, 3 axes 0 ºC to +70 ºC -40 ºC to +85 ºC 5-95% RH 10,000 ft max. 30,000 ft max. 0.03 g2/Hz 20 g peak EMC CHARACTERISTICS Line frequency harmonics EN55011 and EN55022, FCC part15 EN61000-3-2 Voltage fluctuations EN61000-3-3 Clause 5b ESD air EN61000-4-2 Level 3 ESD contact EN61000-4-2 Level 3 INPUT SPECIFICATIONS Radiated immunity EN61000-4-3 Level 3 AC input voltage Fast transients EN61000-4-4 Level 3 Line surge immunity EN61000-4-5 Level 3 Conducted immunity EN61000-4-6 Level 3 Power freq. mag. field EN61000-4-8 Voltage dip immunity EN61000-4-11 Auxillary Output ±6.0% Always on (See Note 1) 5 V @ 50 mA Thermal protection Automatic recovery +125 ºC (PCB Temp) REMOTE_ENABLE Input Low Voltage Input High Voltage 0.45 V (max) 4.15 V (min) Universal range Input frequency Input current 85-264 Vrms 47-63 Hz 115 Vrms @ 500 W 230 Vrms @ 500 W Power factor Input surge current 264 Vrms (cold start) Internal input fuses Both AC lines 5 Arms 2.5 Arms >0.98 Conducted emissions Level B Class A 3 A/m Perf Criteria A, A, B <5% UT 10 ms, 70% UT 500 ms, 40% UT 100 ms 40 A max. 10.0 A SAFETY AGENCY CERTIFICATIONS (pending) All certification marks appear on individual unit labels. UL60950 IEC/EN 60950 CE Marked cUL CSA Standards NOTES: 1. Derate 1 mA per °C above 50 °C ambient temperature. 2. Leakage currents: AC Leakage Current from Input to Earth Normal Open Neutral Condition Fault AC Line Connection 240 V L-N, 1 phase ACuQor Typical at 110% nominal input 208 V L-L, 120 V L-N, 1 of 3 phases voltage 60 Hz 240 V L-N-L, 120 V L-N, split phase Product # AQ0500IUxx Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005054 Rev. 1 400 µA 800 µA 200 µA 400 µA 200 µA 400 µA 09/04/08 Page 2 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 500 W Series Grade: Industrial Y R A IN M LI E R P Technical Specification EFFICIENCY, DERATING, AND VOUT DROOP CURVES 100 13.5 95 13.0 80 75 115 Vrms 70 12.5 12.0 Continuous 11.5 11.0 230 Vrms 65 10.5 0 100 200 300 400 500 600 700 0 6 12 18 24 100 42 44 48 50 54 60 27 95 26 80 75 115 Vrms 70 25 24 Continuous 23 22 230 Vrms 65 0 100 200 300 400 500 600 21 700 0 Output Power (W) Figure 3: 24 VOUT efficiency curves. 6 12 22 18 Output Load (A) 24 15 Second Transient 20% Duty 85 120 Second Transient 50% Duty Output Voltage (V) 90 25 30 Figure 4: 24 VOUT droop characteristics. 100 40.5 95 39.0 85 80 75 115 Vrms 70 37.5 36.0 Continuous 34.5 33.0 230 Vrms 65 31.5 0 100 200 300 400 500 600 700 0 Output Power (W) Figure 5: 36 VOUT efficiency curves. Product # AQ0500IUxx Series Phone 1-888-567-9596 3 6 9 12 Output Load (A) 15 16.5 18.75 18 15 Second Transient 20% Duty Output Voltage (V) 90 120 Second Transient 50% Duty Efficiency (%) 36 Figure 2: 12 VOUT droop characteristics. Figure 1: 12 VOUT efficiency curves. Efficiency (%) 30 Output Load (A) Output Power (W) 15 Second Transient 20% Duty 85 120 Second Transient 50% Duty Output Voltage (V) Efficiency (%) 90 21 Figure 6: 36 VOUT droop characteristics. www.synqor.com Doc.# 005-005054 Rev. 1 09/04/08 Page 3 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 500 W Series Grade: Industrial Y R A IN M LI E R P Technical Specification EFFICIENCY, DERATING, AND VOUT DROOP CURVES 100 54 95 52 80 75 115 Vrms 70 50 48 Continuous 46 44 230 Vrms 65 42 0 100 200 300 400 500 600 700 0 Output Power (W) 600 500 500 400 400 Power (W) Power (W) 600 300 200 9 11 Output Load (A) 12.5 12 15 300 200 24 / 36 / 48 V, VIN ≥ 105 Vrms 100 24 / 36 / 48 V, VIN = 85 Vrms 12 V, VIN ≥ 105 Vrms 24 / 36 / 48 V with Fan Enabled 12 V with Fan Enabled 12 V, VIN = 85 Vrms 0 0 0 10 20 30 40 50 60 70 80 0 10 Ambient / Case Temperature (ºC) 700 700 600 600 500 500 Power (W) 800 400 300 0 105 132 150 170 210 0 264 Input AC Voltage (VRMS) Figure 11: Rated output power vs Input AC Voltage. Product # AQ0500IUxx Series Phone 1-888-567-9596 50 60 70 80 300 Transient (24/36/48 V Out) 100 Continuous (12 V Out) 85 40 400 200 Transient (12 V Out) 100 30 Figure 10: Fan Disabled continuous power derating curve in natural convection. 800 200 20 Case Temperature (ºC) Figure 9: Continuous power derating curve in natural convection. For Fan Disabled, see Figure 10. Power (W) 6 Figure 8: 48 VOUT droop characteristics. Figure 7: 48 VOUT efficiency curves. 100 3 15 Second Transient 20% Duty 85 120 Second Transient 50% Duty Output Voltage (V) Efficiency (%) 90 Continuous (24/36/48 V Out) 85 132 264 170 Input AC Voltage (VRMS) Figure 12: Rated output power vs Input AC Voltage. www.synqor.com Doc.# 005-005054 Rev. 1 09/04/08 Page 4 Y R A IN M Technical Top SpecificationRight LI E R P Bottom AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 500 W Series Industrial Grade: Back MECHANICAL DRAWINGS (1 Module Encased Version — E Package Type) Top Right Bottom Front Back NOTES (applies to all mechanicals) 1)Recommendedscrewtighteningtorqueof6in.lbs 2)Undimensionedcomponentsareshownforvisualreferenceonly 3)Alldimensionsininches[mm] Tolerances: x.xxin±0.02 x.xxxin±0.010 Product # AQ0500IUxx Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005054 Rev. 1 09/04/08 Page 5 Y R A IN M Technical Specification LI E R P AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 500 W Series Grade: Industrial MECHANICAL DRAWINGS (2 Modules Flat Version — R Package Type) Product # AQ0500IUxx Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005054 Rev. 1 09/04/08 Page 6 Y R A IN M Technical Specification LI E R P AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 500 W Series Grade: Industrial MECHANICAL DRAWINGS (3 Modules Flat Version — T Package Type) Product # AQ0500IUxx Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005054 Rev. 1 09/04/08 Page 7 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 500 W Series Grade: Industrial Y R A IN M Technical Specification LI E R P CONNECTOR DETAILS OUTPUT CONNECTOR PINOUT (top side) Pin 1 FAN_GOOD Open collector with internal 5V pullup. See Figure A. Pulsed low on fan failure, 100ms, 50% duty. Short to VOUT(-) to disable fan. Pin 2 AC_POWER_GOOD Open collector with internal 5V pullup. See Figure B. Pulled low on AC power dropout. Pin 3 DC_POWER_GOOD Open collector with internal 5V pullup. See Figure B. Pulled low during startup ramp and within 5 ºC of temperature shutdown threshold. Pin 4 5V_STANDBY 5 V @ 50 mA available whenever AC power is applied. Pin 5 VOUT(+) Positive Output Voltage. Pin 6 VOUT(+) Positive Output Voltage. Pin 7 VOUT(+) Positive Output Voltage. Pin 8 VOUT(+) Positive Output Voltage. Pin 9 Reserved Reserved for future use. Pin 10 Reserved Reserved for future use. Pin 11 REMOTE_ENABLE Logic input. See Figure C. Pull high to enable main output. Pin 12 VOUT(–) Negative Output Voltage. Pin 13 VOUT(–) Negative Output Voltage. Pin 14 VOUT(–) Negative Output Voltage. Pin 15 VOUT(–) Negative Output Voltage. Pin 16 VOUT(–) Negative Output Voltage. Figure A: Fan status output / Fan enable input interface circuitry. 5V_STANDBY 1N4148 5k AC_POWER_GOOD or DC_POWER_GOOD VOUT(+) Positive Output Voltage. Pin 2 VOUT(+) Positive Output Voltage. Pin 3 VOUT(+) Positive Output Voltage. Pin 4 VOUT(+) Positive Output Voltage. Pin 5 VOUT(–) Negative Output Voltage. Pin 6 VOUT(–) Negative Output Voltage. Pin 7 VOUT(–) Negative Output Voltage. Pin 8 VOUT(–) Negative Output Voltage 2N3904 From AC/DC Monitor Circuitry 0.1 µF VOUT(-) Figure B: Power good interface circuitry. 5V_STANDBY 5V_STANDBY 12 V OUTPUT CONNECTOR PINOUT (bottom side) Pin 1 10 Ohms REMOTE_ENABLE 10 Ohms 5k 0.1 µF To Enable Circuitry 10k VOUT(-) Figure C: Remote enable interface circuitry. MATING CONNECTORS INDIVIDUAL INPUT CONNECTOR PINOUT Pin 1 Ground Pin 3 AC Neutral Pin 5 AC Line Product # AQ0500IUxx Series Connector Type Contact OUTPUT (16 pins) Molex 430251600 Molex 430300008* 12V_OUTPUT (8 pins) Molex 436450800 Molex 430300008* INPUT JST VHR-5N JST SVH-41T-P1.1 * Each contact rated for a maximum of 5.5 A. Phone 1-888-567-9596 www.synqor.com Doc.# 005-005054 Rev. 1 09/04/08 Page 8 Y R A IN M LI E R P Technical Specification AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 500 W Series Grade: Industrial PARALLEL OPERATION - MULTIPLE UNITS Chassis configurations for Parallel Units ACuQor units are available either open-frame or pre-mounted at the factory. Up to 3 units can be mounted into a chassis, in either side-by-side or stacked configurations. For a complete list of options, see the “Part Numbering System” table on the last page, under “Package Type”, along with the Mechanical Drawings pages. Only side-by-side configurations can be populated with 500W units, since each includes a thermal pad underneath. Interconnection of Parallel Units ACuQor units mounted in 2 and 3 unit chassis are not connected together. This allows the physical routing and connectivity of the external wiring to be customized to each application. The following table summarizes the recommended wiring to operate multiple units in parallel: Specifications of Parallel Units As a rule, units wired in parallel behave the same as single units. Any specification will remain unchanged that is expressed in units of voltage, time, frequency, or efficiency. Specifications expressed in terms of power, current, or capacitance, should be scaled by the number of units wired in parallel. ACuQor units are individually calibrated at the factory, so that the output voltage vs. output current characteristic is always consistent (see Vout droop characteristic figures). As such, multiple units will share output current accurately. Full current is guaranteed from a bank of multiple units wired in parallel. Output Connector Signal Suggested Connection Behavior with Multiple Units REMOTE_ENABLE Wire in parallel Inputs activated simultaneously FAN_GOOD “ Wired-OR outputs – can be pulled low by any unit during an abnormal condition. AC_POWER_GOOD “ “ DC_POWER_GOOD “ “ VOUT(+), VOUT(-) “ Built-in droop characteristic ensures graceful current sharing. 12V_STANDBY* “ “ 5V_STANDBY Do not wire in parallel Fully regulated characteristic does not support current sharing. If placed in parallel, only the output with the highest set-point will drive current. *Note: Triple output models only. Product # AQ0500IUxx Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005054 Rev. 1 09/04/08 Page 9 Y R A IN M Technical Specification LI E R P AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 500 W Series Grade: Industrial INSTALLATION INSTRUCTIONS General:ACuQorAC/DCpowersuppliesareintendedforuse as components in industrial equipment. ACuQor units must be properly installed within end use equipment before they can be safely applied as described in this document. The suitability of theACuQor/equipmentcombinationmustbeverifiedthroughend productinvestigation. Mounting:RefertotheMechanicalDrawingssection.ACuQor unitsareprovidedwiththreadedstainless-steelstand-offsorinserts formounting.Thismountinghardwareisinternallyconnectedto the input connector protective-earth terminal for functional-earth EMCcontrol.Anyorientation(vertical,horizontal,etc.)maybe used.Adequateairspaceshouldbeprovidedoverthefanintake (top) and exhaust (sides) to allow for exchange of cooling air. ACuQorisdesignedforapollutiondegree2environment.The suitabilityoftheenclosedACuQormechanicalassembliesmustbe verifiedthroughendproductinvestigation. Encased models: A minimum of 5 mm electrical clearance shouldbeallowedfromtheconnectorendsofencasedmodels. Input: Refer to the Connector Details section for input connectorwiring.ACuQorproductsrequireasinglephaseACpower sourceof100-240V50/60Hznominal.Refertonameplatelabel for input current ratings. A protective-earth connection is also required. Minimum wire size of 18 AWG (0.8mm2) is recommended.BothsidesoftheAClineareinternallyfused(seetable forspecificmodels).Thesefusesarenotuserreplaceable. MODEL AQ0300 AQ0400 AQ0500 Input Fuses (in Both AC Lines) Littelfuse6.3A250V21606.3XEP Littelfuse6.3A250V21606.3XEP Littelfuse10.0A250V216010XEP Product # AQ0500IUxx Series Phone 1-888-567-9596 Output: Refer to the Connector Details section for output connector wiring and signal I/O functionality. Refer to nameplate label for output current ratings. Main DC output (Vout+, Vout-) pins should use 20 AWG (0.5mm2) wire size. Individual main outputpinsshouldnotbeloadedtomorethan5.5A.Forcurrents greaterthan5.5A,multiplemainoutputpins/wiresmustbeused inparallel.AllsignalI/OpinsarereferencedtoVout-. EMC:ACuQorproductshavebeentestedtotheEMCspecificationslistedintheElectricalCharacteristicssection.However,end useequipmentmustbetestedtoverifyEMCcompliance. Hipot Testing: ACuQor products are rated for Hipot testing levels of 1500 Vac input to protective-earth, 500 Vac output to protective-earth, and 3000 Vac input to output. When performing the 3000 Vac input to output test, the test voltage must be balanced evenly 1500 Vac input and output to protective-earth. Two oppositely phased test voltage sources or a single test voltagesourcewithexternalbalancingimpedances(capacitors)may beusedtopreventoverstressinginputoroutputtoprotective-earth insulationperIEC/ENC60950-1. Fuses Total 2 2 2 www.synqor.com Doc.# 005-005054 Rev. 1 09/04/08 Page 10 AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 500 W Series Grade: Industrial Y R A IN M LI E R P Technical Specification PART NUMBERING SYSTEM The part numbering system for SynQor’s ACuQor AC/DC power supplies follows the format shown in the table below. Notallcombinationsmakevalidpartnumbers,pleasecontactSynQorforavailability. Family AQ ACuQor series of ac-dc semi-regulated output power supplies Output Power 0300: 300 W 0400: 400 W 0500: 500 W 0600: 600 W (2 x 300 W) 0800: 800 W (2 x 400 W) 0900: 900 W (3 x 300 W) 1000: 1000 W (2 x 500 W) 1200: 1200 W (3 x 400 W) 1500: 1500 W (3 x 500 W) Grade I: industrial Range U: universal (85-264 VRMS) Output Voltage Package Type (xx=Standard; xT=Triple) (Correlates to Output Power) 12: 12 V 1T: 12 V / 5 & 12 V STBY 24: 24 V 2T: 24 V / 5 & 12 V STBY 36: 36 V 3T: 36 V / 5 & 12 V STBY 48: 48 V 4T: 48 V / 5 & 12 V STBY E: 1 unit (3" x 5") R: 2 units; flat S: 2 units; stacked T: 3 units; flat U: 3 units; stacked Thermal Design A: open frame C: encased Q: encased only Options Industrial Grade: IND: Industrial Example: AQ1000IU12RQIND ACCESSORIES SynQoroffersaseriesofassembliesthatcanbeorderedaccordingtothetablebelow.Mechanicaldrawingsfortheseaccessoriesare availablefordownloadinpdfformatfromtheSynQorwebsite. Part Number Description AQ-CBL-INPUT1C Input mating cable with pre-stripped wire ends (36" long). AQ-CBL-OUT1C Output mating cable with pre-stripped wire ends (18" long). AQ-CBL-OUT1CD Same as AQ-CBL-OUT1C with an additional 8-pin connector. AQ-CBL-OUT2C AQ-CBL-OUT2CD AQ-INSUL1M AQ-EVAL-PRL3 Output mating cable with connectors on both ends (18" long). Same as AQ-CBL-OUT2C with an additional 8-pin connector. Single module bottom-side Mylar insulator for open frame mounting. Evaluation board for up to three paralleled modules. APPLICATION NOTES AvarietyofapplicationnotesandtechnicalwhitepaperscanbedownloadedinpdfformatfromtheSynQorwebsite. PATENTS SynQorholdsthefollowingpatents,oneormoreofwhichmightapplytothisproduct: 5,999,417 6,222,742 6,545,890 6,594,159 6,731,520 6,894,468 6,927,987 7,050,309 7,072,190 7,119,524 7,269,034 7,272,021 Contact SynQor for further information: Phone: TollFree: Fax: E-mail: Web: Address: 978-849-0600 888-567-9596 978-849-0602 [email protected] www.synqor.com 155SwansonRoad Boxborough,MA01719,USA Product # AQ0500IUxx Series Phone 1-888-567-9596 6,577,109 6,896,526 7,085,146 7,272,023 Warranty:SynQoroffersatwo(2)yearlimitedwarranty.CompletewarrantyinformationislistedonourwebsiteorisavailableuponrequestfromSynQor. Limitation on use: SynQor’s products are not authorized for use and should not be used, without the specific prior written approval of an authorized officer of SynQor makingspecificreferencehereto,inanylifesupportsystem,nuclearfacilityorapplication,aircraftcontrolapplicationoranyotherapplicationinwhichfailureoftheproduct couldreasonablyresultinharmtolife,propertyortheenvironment. InformationfurnishedbySynQorisbelievedtobeaccurateandreliable.However, noresponsibilityisassumedbySynQorforitsuse,norforanyinfringementsofpatents orotherrightsofthirdpartieswhichmayresultfromitsuse.Nolicenseisgrantedby implicationorotherwiseunderanypatentorpatentrightsofSynQor. www.synqor.com Doc.# 005-005054 Rev. 1 09/04/08 Page 11