DDK ARR-N-SA-JP-D1

ARR Series
Coaxial Arrester
●It is a connector developed to protect the
equipment from the voltage of serge by the
thunder by discharging the gas arrestor.
●The voltage of the thunder serge which invaded
from the antenna is prevented from joining the
base bureau circuit.
●The gas arrestor is built-in in the connector.
●It is possible to correspond to the usage that
the use frequency band region is wide, and various.
APPLICATION
PHS base station, cellular phone base station, ETC, wirelesses LAN, and antennas.
SPECIFICATION
Characteristic Impedance
50Ω
Insulation resistance
100MΩmin. at 100V DC
Contact resistance
6mΩ max.
VSWR
N Type 1.2max. at DC~6GHz
TNC Type 1.25max. at DC~6GHz
SMA(DM)Type 1.2max. at DC~3GHz
Insulation Loss
0.3dBmax. at DC~6GHz
DC Breakdown Voltage
150Vmin. at 100V/sec
Inpact Breakdown Voltage
700Vmin. at 1000V/μsec
Max. Inpact Discharge Current
10KA max. (8/20μsec)
MATERIAL/FINISH
Contact
Copper alloy/Gold plating
Shell
Copper alloy/Nickel plating
Insulator
PTFE
● 1 ●
ARR Series
Unit : mm
■ Coaxial Arrester
ARR-N-SA-JP-D1
ARR-DM-SA-JP
φ14
(φ21)
M3 × 0.5
(39.3)
(45.5)
(φ21)
ARR-N-SA-JP-1-D1
Ground Terminal
(45.5)
Ground Applicable Cable:AWG16 ~ 22
ARR-TNC-SA-JP-D1
(φ17.5)
M3 × 0.5
(40)
(φ17.5)
ARR-TNC-SA-JP-1-D1
Ground Terminal
(40)
Ground Applicable Cable:AWG16 ~ 22
● 2 ●