ARR Series Coaxial Arrester ●It is a connector developed to protect the equipment from the voltage of serge by the thunder by discharging the gas arrestor. ●The voltage of the thunder serge which invaded from the antenna is prevented from joining the base bureau circuit. ●The gas arrestor is built-in in the connector. ●It is possible to correspond to the usage that the use frequency band region is wide, and various. APPLICATION PHS base station, cellular phone base station, ETC, wirelesses LAN, and antennas. SPECIFICATION Characteristic Impedance 50Ω Insulation resistance 100MΩmin. at 100V DC Contact resistance 6mΩ max. VSWR N Type 1.2max. at DC~6GHz TNC Type 1.25max. at DC~6GHz SMA(DM)Type 1.2max. at DC~3GHz Insulation Loss 0.3dBmax. at DC~6GHz DC Breakdown Voltage 150Vmin. at 100V/sec Inpact Breakdown Voltage 700Vmin. at 1000V/μsec Max. Inpact Discharge Current 10KA max. (8/20μsec) MATERIAL/FINISH Contact Copper alloy/Gold plating Shell Copper alloy/Nickel plating Insulator PTFE ● 1 ● ARR Series Unit : mm ■ Coaxial Arrester ARR-N-SA-JP-D1 ARR-DM-SA-JP φ14 (φ21) M3 × 0.5 (39.3) (45.5) (φ21) ARR-N-SA-JP-1-D1 Ground Terminal (45.5) Ground Applicable Cable:AWG16 ~ 22 ARR-TNC-SA-JP-D1 (φ17.5) M3 × 0.5 (40) (φ17.5) ARR-TNC-SA-JP-1-D1 Ground Terminal (40) Ground Applicable Cable:AWG16 ~ 22 ● 2 ●