AZETTLER AZ881-1A-12D

AZ881
8 A SPST / 5 A DPST POLARIZED
SUBMINIATURE POWER RELAY
SINGLE SIDE STABLE (NON-LATCHING)
AND BISTABLE (LATCHING)
FEATURES
•
•
•
•
•
•
•
GENERAL DATA
Dielectric strength 3000 Vrms
Single and dual coil latching versions available
Epoxy sealed version available
8 Amp switching
Class B (130°C) insulation standard
Class F (155°C) insulation available
UL, CUR file E44211
Life Expectancy
Mechanical
Electrical
Minimum operations
1 x 107
1 x 105 at 8 A 250 VAC resistive (SPST)
Operate Time (typical)
5 ms at nominal coil voltage
Release Time (typical)
3 ms at nominal coil voltage
(with no coil suppression)
Set Time (typical)
5 ms at nominal coil voltage
Reset Time (typical)
4 ms at nominal coil voltage
Dielectric Strength
(at sea level)
4000 Vrms contact to coil
1000 Vrms between open contacts
2000 Vrms between contact sets
Insulation Resistance
1000 megohms min. at 20°C
500 Vdc 50% RH
Dropout
Greater than 10% of nominal coil voltage
Ambient Temperature
Operating
Storage
At nominal coil voltage
-40°C (-40°F) to 70°C (158°F)
-40°C (-40°F) to 130°C (266°F)
SPST
8 A at 250 VAC resistive, 100k cycles
5 A at 30 VDC resistive, 100k cycles
1/6 HP at 250 VAC
Vibration
0.078” DA at 10 to 55 Hz
Shock
20 g functional
100 g destructive
DPST
5 A at 250 VAC resistive, 100k cycles
5 A at 30 VDC resistive, 100k cycles
1/6 HP at 250 VAC
Enclosure
P.B.T. polyester
Terminals
Tinned copper alloy, P.C.
Max. Solder Temp.
270°C (518°F)
Material
Silver nickel, gold plating optional
Max. Solder Time
5 seconds
Resistance
< 50 milliohms initially (6 V 1 A voltage drop
method)
Max. Solvent Temp.
80°C (176°F)
Max. Immersion Time
30 seconds
Weight
4.7 grams
CONTACTS
Arrangement
SPST (1 Form A), DPST (2 Form A)
DPST (1 Form A and 1 Form B)
Ratings
Resistive load:
Max. switched power:
150 W or 2000 VA (SPST)
150 W or 1250 VA (DPST)
Max. switched current: 8 A (SPST)
5 A (DPST)
Max. switched voltage:150 VDC or 380 VAC*
*Note: If switching voltage is greater than 30 VDC,
special precautions must be taken. Please contact
the factory.
Rated Load
UL, CUR
COIL
Power
At Pickup Voltage
192 mW (single side stable, 2 coil latching)
(typical)
96 mW (1 coil latching)
Max. Continuous
Dissipation
0.75 W at 20°C (68°F) ambient
Temperature Rise
30°C (54°F) at nominal coil voltage
Max. Temperature
130°C (266°F) Class B, 155°C (311°F)
Class F
NOTES
1.
2.
3.
4.
All values at 20°C (68°F).
Relay may pull in with less than “Must Operate” value.
Relay has fixed coil polarity.
For complete isolation between the relay’s magnetic fields, it is recommended that a .197" (5.0 mm) space be provided between adjacent relays.
5. Relay adjustment may be affected if undue pressure is exerted
on relay case.
6. Specifications subject to change without notice.
1/29/07W
AZ881
RELAY ORDERING DATA
AZ881
COIL SPECIFICATIONS - SINGLE SIDE STABLE
Nominal
Coil
VDC
3
Must.
Operate
VDC
2.4
Max. Continuous
VDC
Coil
Resistance
± 10%
30
5
4.0
7.9
83
6
4.8
9.6
9
7.2
14.4
12
9.6
19.2
480
24
19.2
37.9
1920
4.7
ORDER NUMBER*
1 Form A
2 Form A
1 Form A
1 Form B
AZ881-1A-3D
AZ881-2A-3D
AZ881-1AB-3D
AZ881-1A-5D
AZ881-2A-5D
AZ881-1AB-5D
120
AZ881-1A-6D
AZ881-2A-6D
AZ881-1AB-6D
270
AZ881-1A-9D
AZ881-2A-9D
AZ881-1AB-9D
AZ881-1A-12D
AZ881-1A-24D
AZ881-2A-12D
AZ881-2A-24D
AZ881-1AB-12D
AZ881-1AB-24D
*Add suffix “E” for epoxy sealed version. Add suffix “A” for gold plated contacts. Add suffix “R” for reversed polarity coil. Add suffix “F” for class F insulation.
AZ881P1
COIL SPECIFICATIONS - SINGLE COIL LATCHING
ORDER NUMBER*
Nominal
Coil
VDC
3
Must.
Operate
VDC
2.4
Max. Continuous
VDC
AZ881P1-1A-3D
AZ881P1-2A-3D
AZ881P1-1AB-3D
5
4.0
11.2
167
AZ881P1-1A-5D
AZ881P1-2A-5D
AZ881P1-1AB-5D
6
4.8
13.4
240
AZ881P1-1A-6D
AZ881P1-2A-6D
AZ881P1-1AB-6D
9
7.2
20.1
540
AZ881P1-1A-9D
AZ881P1-2A-9D
AZ881P1-1AB-9D
12
9.6
26.8
960
AZ881P1-1A-12D
AZ881P1-2A-12D
AZ881P1-1AB-12D
6.7
Coil
Resistance
± 10%
60
1 Form A
1 Form A
1 Form B
2 Form A
*Add suffix “E” for epoxy sealed version. Add suffix “A” for gold plated contacts. Add suffix “R” for reversed polarity coil. Add suffix “F” for class F insulation.
AZ881P2
COIL SPECIFICATIONS - DUAL COIL LATCHING
ORDER NUMBER*
Nominal
Coil
VDC
3
Must.
Operate
VDC
2.4
Max. Continuous
VDC
5
4.0
7.9
83
6
4.8
9.5
9
7.2
14.2
12
9.6
19.0
480
AZ881P2-1A-12D
AZ881P2-2A-12D
AZ881P2-1AB-12D
24
19.2
37.9
1920
AZ881P2-1A-24D
AZ881P2-2A-24D
AZ881P2-1AB-24D
4.7
Coil
Resistance
± 10%
30
1 Form A
1 Form B
1 Form A
2 Form A
AZ881P2-1A-3D
AZ881P2-2A-3D
AZ881P2-1AB-3D
AZ881P2-1A-5D
AZ881P2-2A-5D
AZ881P2-1AB-5D
120
AZ881P2-1A-6D
AZ881P2-2A-6D
AZ881P2-1AB-6D
270
AZ881P2-1A-9D
AZ881P2-2A-9D
AZ881P2-1AB-9D
*Add suffix “E” for epoxy sealed version. Add suffix “A” for gold plated contacts. Add suffix “R” for reversed polarity coil. Add suffix “F” for class F insulation.
1/29/07W
AZ881
AZ
MECHANICAL DATA
Single side stable &1 coil latching
-2A, -1AB
-1A
Outline Dimensions
0.433MAX
[11.0]
0.795MAX
[20.2]
.433MAX
[11.0]
.795MAX
[20.2]
.394MAX
[10.00]
.394MAX
[10.00]
.134
[3.40]
.016
[0.40]
.048
[1.22]
.031
[0.80]
.300
[7.62]
.400
[10.16]
.016
[0.40]
.134
[3.40]
.016
[0.40]
.300
[7.62]
.048
[1.22]
.400
[10.16]
.031
[0.80]
.300
[7.62]
.016
[0.40]
.300
[7.62]
2 coil latching
-1A
-1A, -1AB
.433MAX
[11.0]
.795MAX
[20.2]
.433MAX
[11.0]
.795MAX
[20.2]
.394MAX
[10.00]
.016
[0.40]
.134
[3.40]
.048
[1.22]
PC Board Layout
.100
[2.54]
.400
[10.16]
.300
[7.62]
.016
[0.40]
.300
[7.62]
.031
[0.80]
.394MAX
[10.00]
.134
[3.40]
.048
[1.22]
-1 AB
-1A
.300
[7.62]
.300
[7.62]
.400
[10.16]
Single side stable (Deenergized condition)
.300
[7.62]
6-Ø.047
[Ø1.20]
-2 A
-1 A
.300
[7.62]
4-Ø.047
[Ø1.20]
.300
[7.62]
.016
[0.40]
.300
[7.62]
.031
[0.80]
Wiring Diagram
Single side stable &
1 coil latching
.400
[10.16]
.016
[0.40]
.100
[2.54]
.400
[10.16]
+
+
-
-
-
1 coil latching(Reset condition)
-2 A
.100
[25.4]
.300
[7.62]
.100
[25.4]
.300
[7.62]
+
set
set
reset
-
+
-1 AB
reset
set
2 coil latching
.300
[7.62]
+
reset
-1 A
-
+
-2A, -1 AB
-1 A
-1 AB
+
-
-
+
-
+
.300
[7.62]
2 coil latching(Reset condition)
Viewed Toward Terminals
+
set
reset
+
-
-
-1 AB
+
reset
+
set
8-[Ø.047]
[Ø1.20]
+
reset
6-[Ø.047]
[Ø1.20]
-2 A
-1 A
.300
[7.62]
set
.300
[7.62]
-
-
-
-
+
Viewed Toward Terminals
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
1/29/07W