ETC B201220006

Timers
Interval
Types B 101, B 201, B 108, B 208
• Time ranges: 0.15 s to 600 s
• Automatic start
• Knob-adjustable time within range
• Oscillator-controlled time circuit
• Repeatability deviation: ≤ 1%
• Output: 10 A SPDT or 8 A DPDT relay
• Plug-in type module
• Scantimer housing
• LED-indication for relay on
• AC or DC power supply
Product Description
Ordering Key
Mono-function, plug-in miniature interval time relays up
to 600 s (10 min) covering 3
individual time ranges. This
economical timer is often
Function
Output
Type
Power supply
Time range
used in applications such as
lubricating pumps, drying elements, etc. where an operation is wanted to last for a longer period of time.
B 108 024 600
Type Selection
Plug
Output
Time ranges
Supply: 24 VAC/DC
Supply: 120 VAC
Supply: 220 VAC
Circular
8 pin
SPDT
0.15 - 6 s
1.5 - 60 s
15 - 600 s
B 108 024 006
B 108 024 060
B 108 024 600
B 108 120 006
B 108 120 060
B 108 120 600
B 108 220 006
B 108 220 060
B 108 220 600
0.15 - 6 s
1.5 - 60 s
15 - 600 s
B 101 024 006
B 101 024 060
B 101 024 600
B 101 120 006
B 101 120 060
B 101 120 600
B 101 220 006
B 101 220 060
B 101 220 600
0.15 - 6 s
1.5 - 60 s
15 - 600 s
B 208 024 006
B 208 024 060
B 208 024 600
B 208 120 006
B 208 120 060
B 208 120 600
B 208 220 006
B 208 220 060
B 208 220 600
0.15 - 6 s
1.5 - 60 s
15 - 600 s
B 201 024 006
B 201 024 060
B 201 024 600
B 201 120 006
B 201 120 060
B 201 120 600
B 201 220 006
B 201 220 060
B 201 220 600
Circular
11 pin
Circular
8 pin
DPDT
Circular
11 pin
Time Specifications
Time ranges
Time range accuracy
0.15- 6 s
1.5 - 60 s
15 - 600 s
0 to +10% on max.
min. actual time ≤ min.
set time
Specifications are subject to change without notice (25.10.99)
Repeatability deviation
Time variation
Within rated power supply
and ambient temperature
Reset
Time and/or relay
≤ 1%
≤ 0.05%/V
≤ 0.2%/°C
Power supply interruption
≥250 ms
1
B 108, B 208, B 101, B 201
Output Specifications
Output
Basic electrical insulation
Contact ratings (AgCdO)
Resistive loads
AC 1
DC 1
or
Small inductive loads AC 15
DC 13
Mechanical life
Electrical life
AC 1
Operating frequency
Insulation voltages
Rated insulation voltage
Rated transient protection volt.
B 108, B 101
B 208, B 201
SPDT relay
250 VAC (rms) (contact/electronics)
µ (micro gap)
10 A/250 VAC (2500 VA)
1 A/250 VDC (250 W)
10 A/25 VDC (250 W)
2.5 A/230 VAC
5 A/24 VDC
≥ 30 x 106 operations
≥ 2.5 x 105 operations (at max. load)
≤ 7200 operations/h
DPDT relay
250 VAC (rms) (contacts/elec., contact/contact)
µ (micro gap)
8 A/250 VAC (2000 VA)
0.4 A/250 VDC (100 W)
4 A/25 VDC (100 W)
2.5 A/230 VAC
5 A/24 VDC
≥ 30 x 106 operations
≥ 2.5 x 105 operations (at max. load)
≤ 7200 operations/h
≥ 2.0 kVAC (rms) (contact/electronics)
4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)
≥ 2.0 kVAC (rms) (contact/electronics)
4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)
Supply Specifications
General Specifications
Power supply AC types
Rated operational voltage
through pins 2 & 10
220
or pins 2 & 7
120
Power ON delay
Power OFF delay
Indication for
Output ON
Environment
Pollution degree
Operating temperature
Storage temperature
Weight
Approvals
Installation cat. III
220 VAC + 15/- 20%,
45 to 65 Hz
120 VAC + 15/- 20%,
45 to 65 Hz
24 VAC + 15/- 20%,
45 to 65 Hz
≥ 10 ms
None
4 kV (1.2/50 µs) @ 220 VAC
2.5 kV (1.2/50 µs) @ 120 VAC
800 V (1.2/50 µs) @ 24 VAC
(line/neutral)
Installation cat. III
24 VDC + 15/- 20% (pin 2 pos.)
None
800 V (1.2/50 µs)
60 mA @ 50 Hz/70 mA @ 60 Hz
1W
024
Drop-out tolerance
Rated insulation voltage
Rated transient protection volt.
Power supply DC type
Rated operational voltage 024
Rated insulation voltage
Rated transient protection volt.
Consumption
AC supply
DC supply
Mode of Operation
The relay operates and the time period starts when power
supply is applied to the time
relay.
At the end of the set delay,
the relay releases and will not
operate again until power
supply is reapplied.
LED. red
IP 20 B
2 (IEC 60664)
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
85 g
UL, CSA
Wiring Diagrams
A recovery period of 250 ms
should be allowed before reapplying power supply.
If power supply is interrupted
for more than 250 ms before
the time period has expired,
the relay releases and the time
is reset to zero.
Power supply
B 108, B 208
2
≤ 200 ms
≥ 250 ms
Power supply
B 101, B 201
Specifications are subject to change without notice (25.10.99)
B 108, B 208, B 101, B 201
Time Setting
Accessories
Knob-adjustable on scale in
seconds.
Sockets◊
Hold down spring◊
Mounting rack
Socket cover
Potentiometer lock
S 408, S 411
HF
SM 13
BB 4
PL 1
For further information refer to "Accessories".
Operation Diagram
Power supply
Relay on
Specifications are subject to change without notice (25.10.99)
3