ETC B59008-C80-A40

Measurement and Control
Disks
B59008
C8
30 V
Applications
● Sensor for small measuring points
● Limit temperature monitoring
Features
● Coated thermistor disk
● Tinned leads
● Marked with coded nominal
threshold temperature
Dimensions (mm)
● Characteristics for nominal threshold temperatures
of 90 to 160 °C conform with DIN 44 081
● Extremely fast response due to small dimensions
Max. operating voltage
(TA = 0 … 40 °C)
Max. measuring voltage
(TA – 25 K … TNAT + 15 K)
Rated resistance
(VPTC ≤ 2,5 V)
Response time
Operating temperature range (V = 0)
(V = Vmax)
Type/
Stamp
code
C8 f
C8 g
C8 h
C8 i
C8 j
C8 k
C8 l
C8 m
C8 n
C8 o
C8 p
C8 r
C8 s
C8 t
C8 u
TNAT ± ∆T R1)
(TNAT – ∆T)
°C
Ω
60 ± 5
≤ 570
70 ± 5
≤ 570
80 ± 5
≤ 570
90 ± 5
≤ 550
100 ± 5
≤ 550
110 ± 5
≤ 550
120 ± 5
≤ 550
130 ± 5
≤ 550
140 ± 5
≤ 550
145 ± 5
≤ 550
150 ± 5
≤ 550
155 ± 5
≤ 550
160 ± 5
≤ 550
170 ± 7
≤ 570
180 ± 7
≤ 570
R1)
(TNAT + ∆T)
Ω
≥ 570
≥ 570
≥ 570
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 570
≥ 570
Vmax
VMeas,max
RN
ta
Top
Top
R 2)
(TNAT + 15 K)
Ω
—
—
—
≥4k
≥4k
≥4k
≥4k
≥4k
≥4k
≥4k
≥4k
≥4k
≥4k
—
—
30
7,5
≤ 250
<3
– 25/+ 125
0/40
R1)
(TNAT + 23 K)
Ω
≥4k
≥4k
≥4k
—
—
—
—
—
—
—
—
—
—
≥4k
≥4k
V
V
Ω
s
°C
°C
Ordering code
B59008-C60-A40
B59008-C70-A40
B59008-C80-A40
B59008-C90-A40
B59008-C100-A40
B59008-C110-A40
B59008-C120-A40
B59008-C130-A40
B59008-C140-A40
B59008-C145-A40
B59008-C150-A40
B59008-C155-A40
B59008-C160-A40
B59008-C170-A40
B59008-C180-A40
1) VPTC ≤ 2,5 V
2) VPTC ≤ 7,5 V
150
Siemens Matsushita Components
B59008
C8
Characteristics (typical)
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
Siemens Matsushita Components
151