3-Line Filters B84143-A*-R206 for Converters and Power Electronics Power line filters for three-phase systems Rated voltage 480/275 V~, 50/60 Hz Rated current 6 to 25 A Construction ■ Three-line filter ■ Metal case ■ Footprint filter Features ■ ■ ■ ■ Low leakage current Easy to install UL approval Optimized for long motor cables and operation under full load Applications ■ Frequency converters for motor drives, e.g. – – – – elevators pumps conveyor systems HVAC systems (heating, ventilation and air conditioning) Terminals ■ Line: Safe-to-touch terminal blocks ■ Load: Litz wires Marking Marking on component: Manufacturer’s logo, ordering code, rated current, rated voltage, rated temperature, date code Minimum marking on packaging: Manufacturer’s logo, ordering code Upon request the dimensions as well as the fixing points of the filters can be matched to customer requirements. The dimensions shown on the following pages are also available for 1-phase systems up to 22 A. 228 03/01 3-Line Filters B84143-A*-R206 for Converters and Power Electronics Typical circuit diagram LINE LOAD L1 L1’ L2 L2’ L3 L3’ SSB1664-T Technical data Rated voltage V R 480/275 V~, 50/60 Hz Rated current IR Referred to 40 °C ambient temperature Test voltage V P 1770 V–, 2 s (line/line) 2700 V–, 2 s (lines/case) Overload capability 1,5 · IR for 3 min per hour or 2,5 · IR for 30 s per hour Leakage current I leak at 480 V~, 50 Hz Climatic category 25/100/21 (– 25 °C/100 °C/21 days damp heat test) in accordance with EN 60068-1 Characteristics and ordering codes Terminal cross section mm2 I leak mA 6 2,5 < 3,5 12 2,5 < 3,5 25 4 <6 IR A Ordering code mΩ Approx. weight kg 72 0,8 B84143-A6-R206 21 1,5 B84143-A12-R206 2,3 B84143-A25-R206 Rtyp 8,5 229 03/01 3-Line Filters B84143-A*-R206 for Converters and Power Electronics Dimensional drawings B84143-A6-R206 Terminal blocks Anschlussklemmen 2,5 mm mm2 2,5 43,5 174 Marking LOAD 3 LINE PE M4 240±10 200±10 4 × ø4,8 L1 L2 L3 59,6±0,2 73 56±0,4 PE 4 × Gewinde M4 Thread M4 min.55mm mmdeep tief min. Litz Litze wire Wire end ferrule Aderendhülse 160±0,4 2 2 Terminal blocks 2,5 2,5 mmmm Anschlussklemmen L1’ L2’ L3’ 187±0,5 200 SSB1584-2 B84143-A12-R206 2 2 Terminal blocks 2,5 Anschlussklemmen 2,5mm mm 43 187 Marking LOAD 2 LINE PE M4 400±10 300±10 4 × ø4,8 120±0,3 149 138±0,3 PE L1’ L2’ L3’ L1 L2 L3 Litz wire Litze WireAderendhülse end ferrule 174±0,3 2 2 Terminal blocks 2,52,5 mm Anschlussklemmen mm Thread M4 4 × Gewinde M4 200±0,3 213 230 03/01 SSB1585-A 3-Line Filters B84143-A*-R206 for Converters and Power Electronics B84143-A25-R206 2 2 Terminal blocks 4 mm Anschlussklemmen 4 mm 55 219 Marking LOAD 2 LINE PE M4 450±10 350±10 4 × ø5,8 156±0,3 185 174±0,3 PE L 3’ L 2’ L 1’ L1 L2 L3 Litz wire Litze WireAderendhülse end ferrule 204±0,3 Thread M5 4 ×× Gewinde M5 232±0,4 245 231 03/01 SSB1586-I 3-Line Filters B84143-A*-R206 for Converters and Power Electronics Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84143-A6-R206 B84143-A12-R206 SSB1581-C 120 dB αe αe 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 10 4 10 5 10 6 10 7 Hz 10 8 f 0 10 4 B84143-A25-R206 SSB1583-T 120 dB αe 100 90 80 70 60 50 40 30 20 10 0 10 4 10 5 10 6 10 7 SSB1582-K 120 dB Hz 10 8 f 232 03/01 10 5 10 6 10 7 Hz 10 8 f Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited. The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. 1