4-Line Filters B84144 for Converters and Power Electronics Power line filters for three-phase systems Rated voltage 440/250 V~, 50/60 Hz Rated current 16 to 1600 A Construction ■ Four-line filter ■ Metal case ■ Threaded bushes at end faces for RF-tight installation Features ■ ■ ■ ■ ■ Low leakage current Easy to install Degree of protection up to 180 A: IP 201) Space-saving design Design based on EN 133200, UL 1283, CSA 22.2 No.8 1986 Applications ■ ■ ■ ■ General-purpose application in power electronics UPS Wind farms For machine tools, textile and packaging machines Terminals ■ Safe-to-touch terminal blocks for filters up to 180 A ■ Busbars for filters 250 to 1600 A Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, date code Minimum marking on packaging: Manufacturer’s logo, ordering code 1) In accordance with IEC 60529: 1989; EN 60529: 1991; DIN VDE 0470-1 274 04/02 4-Line Filters B84144 for Converters and Power Electronics Typical circuit diagram LINE LOAD L1 L1’ L2 L2’ L3 L3’ N N’ PE PE SSB1076-F Technical data Rated voltage V R 440/250 V~, 50/60 Hz Rated current I R Referred to 40 °C ambient temperature Test voltage V P 1770 V–, 2 s (line/line) 2700 V–, 2 s (lines/case), for 16 … 50 A 2550 V–, 2 s (lines/case), for 80 … 180 A 2121 V–, 2 s (lines/case), for 250 … 1600 A Overload capability 1,5 · IR for 3 min per hour or 2,5 · IR für 30 s per hour Leakage current Ileak at 400 V~, 50 Hz Climatic category 25/100/21 (– 25 °C/+100 °C/21 days damp heat test) in accordance with EN 60068-1 275 04/02 4-Line Filters B84144 for Converters and Power Electronics Characteristics and ordering codes Terminal cross section mm2 IR A I leak Rtyp PV mA mΩ W Approx. weight kg Ordering code 16 4 < 3,5 10 8 2,2 B84144-A16-R 25 10 < 3,5 6 11 3,7 B84144-A25-R 36 10 < 3,5 3,5 14 3,7 B84144-A36-R 50 10 <6 1,3 10 4,0 B84144-A50-R 9,5 B84144-A80-R 80 25 <6 0,7 13 120 50 <6 0,5 22 10 B84144-A120-R 150 50 <6 0,35 24 10 B84144-A150-R 180 95 <6 0,25 24 13 B84144-A180-R 250 Busbars <6 0,095 18 32 B84144-G250-S 500 <6 0,060 45 53 B84144-G500-S 1000 <6 0,030 90 140 B84144-G1000-S 1600 <6 0,020 150 185 B84144-G1600-S 276 04/02 4-Line Filters B84144 for Converters and Power Electronics Dimensional drawings 30±1 12,5±0,4 1±0,1 55±0,4 81 max. 36±1 20,5±0,5 B84144-A16-R PE M6 x 25 163 max. 60±0,4 12,5±1 86 max. 70±0,2 Marking LINE LOAD 5,5±0,1 113 max. N L3 L2 L1 100±0,3 N L3 L2 L1 4 x× M5/6 M5 /mm 6 mm tief deep Anschlussklemmen Terminal blocks 2 44 mm mm2 141 max. SSB1077-N PE M6 x 25 216 max. 30±1 65±0,4 12,5±0,4 1±0,1 91 max. 46±1 31±0,5 B84144-A25-R … B84144-A50-R 100±0,4 22,5±1 126 max. 80±0,2 LINE LOAD 6,6±0,2 166 max. 140±0,3 156 max. L2 L1 Marking N L3 N L3 L2 L1 tief deep 4 x× M6/6 M6 /mm 6 mm Anschlussklemmen Terminal blocks 10 mm mm 22 10 277 04/02 SSB1078-W 4-Line Filters B84144 for Converters and Power Electronics 55±1 15±0,4 110±0,4 1,2±0,1 18±1 141 max. 83±1 48,5±0,5 B84144-A80-R PE M10 x 35 110±0,4 141 max. 300 max. 4 x× M6/6 M6 /mm 6 mm tief deep 155±0,3 L3 LINE LOAD N N L3 Marking 6,6±0,2 171 max. L2 L2 L1 L1 115±0,2 Anschlussklemmen Terminal 25 mm 2 blocks 25 mm2 221 max. SSB1079-5 54±0,5 B84144-A120-R, B84144-A150-R PE M10 x 35 110±0,4 141 max. 348 max. tief deep 4 x× M6/6 M6 /mm 6 mm 6,6±0,2 261 max. 171 max. LOAD 155±0,3 Marking N L3 L2 L1 N L3 L2 L1 115±0,2 LINE 55±1 1,2±0,1 110±0,4 15±0,4 141 max. 87±1 18±1 Anschlussklemmen 2 Terminal 50 mm2 50 mmblocks 278 04/02 SSB1086-M 4-Line Filters B84144 for Converters and Power Electronics PE M10 x 35 62±0,8 120±0,4 1,2±0,1 16±0,5 10±0,4 141 max. 105±1 74±0,5 B84144-A180-R 110±0,4 141 max. 404 max. 44x×M6/6 tief deep M6 mm / 6 mm 6,6±0,2 82,5±0,2 LOAD 82,5±0,2 155 ±0,3 L3 LINE N N L3 Marking 171 max. L2 L2 L1 L1 301 max. Anschlussklemmen 95 mm Terminal blocks 95 mm2 2 279 04/02 SSB1087-V 4-Line Filters B84144 for Converters and Power Electronics B84144-G250-S 4 x M8 x 7 190±0,5 N 4 120 24 PE M10 x 30 PE M10 x 30 200±1 ø12 30 ø10,5 L3 L1 LINE LOAD 285 L2/ N 260±1 24±1 L2/ N 230+2 L3 Marking L1 15 _ 3 = 370±3 = 460±6 SSB0996-A 280 04/02 110 171_ 4 N 89,5 4,5±0,5 N L2 L1 105±0,5 L3 48 350+3 34 4 x M8 x 7 4-Line Filters B84144 for Converters and Power Electronics B84144-G500-S 4 x M8 x 7 210±0,5 150±0,5 N N L2 L3 6 N PE M10 x 30 60 26 PE M10 x 30 L1 150 280±1 ø12 30 ø11 L1 LOAD LINE 305 L2/ N 250 Marking L2/ N 280±1 L3 30+3 L3 L1 15 +1 = 510±3 = 590±3 SSB0997-I 281 04/02 134,5 198 _ 4 6±0,5 500 56,5 101,5 4 x M8 x 7 4-Line Filters B84144 for Converters and Power Electronics B84144-G1000-S 4 x M8 x 7 4 x M8 x 7 360±0,8 11±0,5 650+4 L2 L1 N N PE M12 x 30 65 38 PE M12 x 30 28 8 N 78 163 211 290 _ 3 240±0,8 L3 262 320±1 ø12 40 L3 L3 Marking L2/ N LINE 50+10 400+3 440±1 465 ø14 L2/ N LOAD L1 L1 40 = 660±3 840±3 20+1 = SSB0998-R 282 04/02 4-Line Filters B84144 for Converters and Power Electronics Maßbild B84144-G1600-S 4 x M8 x 7 4 x M8 x 7 360±0,8 11±0,5 680+4 L2 L1 N N PE M12 x 30 65 38 PE M12 x 30 28 8 N 78 163 211 290 _ 3 240±0,8 L3 262 340±1 ø12 40 L3 L3 Marking L2/ N LINE 50+10 400+3 440±1 465 ø14 L2/ N LOAD L1 L1 40 = 690±3 870±3 20 +1 = SSB0999-Z 283 04/02 4-Line Filters B84144 for Converters and Power Electronics Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84144-A16-R … -A36-R SSB1677-Q 100 αe B84144-A50-R dB αe 80 60 60 40 40 20 20 10 5 10 6 10 7 0 10 4 Hz 10 8 f B84144-A80-R SSB1090-F dB 10 6 10 7 Hz 10 8 f αe dB 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 10 5 10 6 10 7 Hz 10 8 f SSB1091-N 100 80 0 10 4 10 5 B84144-A120 … -A150-R 100 αe dB 80 0 10 4 SSB1678-Y 100 0 10 4 10 5 10 6 10 7 Hz 10 8 f 284 04/02 4-Line Filters B84144 for Converters and Power Electronics Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84144-A180-R B84144-G250-S … -G1600-S SSB1092-W 100 αe dB αe 80 SSB1000-K 100 dB 80 70 60 60 50 40 40 30 20 20 10 0 10 4 10 5 10 6 10 7 Hz 10 8 f 0 10 4 285 04/02 10 5 10 6 10 7 Hz 10 8 f Herausgegeben von EPCOS AG Unternehmenskommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND ++49 89 636 09, FAX (0 89) 636-2 26 89 ( EPCOS AG 2002. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Corporate Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY ++49 89 636 09, FAX (0 89) 636-2 26 89 ( EPCOS AG 2002. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. 1