EPCOS B84144-A50-R

4-Line Filters
B84144
for Converters and Power Electronics
Power line filters for three-phase systems
Rated voltage 440/250 V~, 50/60 Hz
Rated current 16 to 1600 A
Construction
■ Four-line filter
■ Metal case
■ Threaded bushes at end faces for
RF-tight installation
Features
■
■
■
■
■
Low leakage current
Easy to install
Degree of protection up to 180 A: IP 201)
Space-saving design
Design based on
EN 133200, UL 1283, CSA 22.2 No.8 1986
Applications
■
■
■
■
General-purpose application in power electronics
UPS
Wind farms
For machine tools, textile and packaging machines
Terminals
■ Safe-to-touch terminal blocks for filters up to 180 A
■ Busbars for filters 250 to 1600 A
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current,
date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
1) In accordance with IEC 60529: 1989; EN 60529: 1991; DIN VDE 0470-1
274 04/02
4-Line Filters
B84144
for Converters and Power Electronics
Typical circuit diagram
LINE
LOAD
L1
L1’
L2
L2’
L3
L3’
N
N’
PE
PE
SSB1076-F
Technical data
Rated voltage V R
440/250 V~, 50/60 Hz
Rated current I R
Referred to 40 °C ambient temperature
Test voltage V P
1770 V–, 2 s (line/line)
2700 V–, 2 s (lines/case), for 16 … 50 A
2550 V–, 2 s (lines/case), for 80 … 180 A
2121 V–, 2 s (lines/case), for 250 … 1600 A
Overload capability
1,5 · IR for 3 min per hour or
2,5 · IR für 30 s per hour
Leakage current Ileak
at 400 V~, 50 Hz
Climatic category
25/100/21 (– 25 °C/+100 °C/21 days damp heat test)
in accordance with EN 60068-1
275 04/02
4-Line Filters
B84144
for Converters and Power Electronics
Characteristics and ordering codes
Terminal
cross section
mm2
IR
A
I leak
Rtyp
PV
mA
mΩ
W
Approx.
weight
kg
Ordering code
16
4
< 3,5
10
8
2,2
B84144-A16-R
25
10
< 3,5
6
11
3,7
B84144-A25-R
36
10
< 3,5
3,5
14
3,7
B84144-A36-R
50
10
<6
1,3
10
4,0
B84144-A50-R
9,5
B84144-A80-R
80
25
<6
0,7
13
120
50
<6
0,5
22
10
B84144-A120-R
150
50
<6
0,35
24
10
B84144-A150-R
180
95
<6
0,25
24
13
B84144-A180-R
250
Busbars
<6
0,095
18
32
B84144-G250-S
500
<6
0,060
45
53
B84144-G500-S
1000
<6
0,030
90
140
B84144-G1000-S
1600
<6
0,020
150
185
B84144-G1600-S
276 04/02
4-Line Filters
B84144
for Converters and Power Electronics
Dimensional drawings
30±1
12,5±0,4
1±0,1
55±0,4
81 max.
36±1
20,5±0,5
B84144-A16-R
PE M6 x 25
163 max.
60±0,4
12,5±1
86 max.
70±0,2
Marking
LINE
LOAD
5,5±0,1
113 max.
N L3 L2 L1
100±0,3
N L3 L2 L1
4 x× M5/6
M5 /mm
6 mm
tief deep
Anschlussklemmen
Terminal
blocks
2
44 mm
mm2
141 max.
SSB1077-N
PE M6 x 25
216 max.
30±1
65±0,4
12,5±0,4
1±0,1
91 max.
46±1
31±0,5
B84144-A25-R … B84144-A50-R
100±0,4
22,5±1
126 max.
80±0,2
LINE
LOAD
6,6±0,2
166 max.
140±0,3
156 max.
L2 L1
Marking
N L3
N L3
L2 L1
tief deep
4 x× M6/6
M6 /mm
6 mm
Anschlussklemmen
Terminal
blocks
10 mm
mm 22
10
277 04/02
SSB1078-W
4-Line Filters
B84144
for Converters and Power Electronics
55±1
15±0,4
110±0,4
1,2±0,1
18±1
141 max.
83±1
48,5±0,5
B84144-A80-R
PE M10 x 35
110±0,4
141 max.
300 max.
4 x× M6/6
M6 /mm
6 mm
tief deep
155±0,3
L3
LINE
LOAD
N
N
L3
Marking
6,6±0,2
171 max.
L2
L2
L1
L1
115±0,2
Anschlussklemmen
Terminal
25 mm 2 blocks
25 mm2
221 max.
SSB1079-5
54±0,5
B84144-A120-R, B84144-A150-R
PE M10 x 35
110±0,4
141 max.
348 max.
tief deep
4 x× M6/6
M6 /mm
6 mm
6,6±0,2
261 max.
171 max.
LOAD
155±0,3
Marking
N L3 L2 L1
N L3 L2 L1
115±0,2
LINE
55±1
1,2±0,1
110±0,4
15±0,4
141 max.
87±1
18±1
Anschlussklemmen
2
Terminal
50 mm2
50 mmblocks
278 04/02
SSB1086-M
4-Line Filters
B84144
for Converters and Power Electronics
PE M10 x 35
62±0,8
120±0,4
1,2±0,1
16±0,5
10±0,4
141 max.
105±1
74±0,5
B84144-A180-R
110±0,4
141 max.
404 max.
44x×M6/6
tief deep
M6 mm
/ 6 mm
6,6±0,2
82,5±0,2
LOAD
82,5±0,2
155 ±0,3
L3
LINE
N
N
L3
Marking
171 max.
L2
L2
L1
L1
301 max.
Anschlussklemmen
95 mm
Terminal blocks
95 mm2
2
279 04/02
SSB1087-V
4-Line Filters
B84144
for Converters and Power Electronics
B84144-G250-S
4 x M8 x 7
190±0,5
N
4
120
24
PE M10 x 30
PE M10 x 30
200±1
ø12
30
ø10,5
L3
L1
LINE
LOAD
285
L2/
N
260±1
24±1
L2/
N
230+2
L3
Marking
L1
15 _ 3
=
370±3
=
460±6
SSB0996-A
280 04/02
110
171_ 4
N
89,5
4,5±0,5
N
L2 L1
105±0,5
L3
48
350+3
34
4 x M8 x 7
4-Line Filters
B84144
for Converters and Power Electronics
B84144-G500-S
4 x M8 x 7
210±0,5
150±0,5
N
N
L2
L3
6
N
PE M10 x 30
60
26
PE M10 x 30
L1
150
280±1
ø12
30
ø11
L1
LOAD
LINE
305
L2/
N
250
Marking
L2/
N
280±1
L3
30+3
L3
L1
15 +1
=
510±3
=
590±3
SSB0997-I
281 04/02
134,5
198 _ 4
6±0,5
500
56,5
101,5
4 x M8 x 7
4-Line Filters
B84144
for Converters and Power Electronics
B84144-G1000-S
4 x M8 x 7
4 x M8 x 7
360±0,8
11±0,5
650+4
L2
L1
N
N
PE M12 x 30
65
38
PE M12 x 30
28
8
N
78
163
211
290 _ 3
240±0,8
L3
262
320±1
ø12
40
L3
L3
Marking
L2/
N
LINE
50+10
400+3
440±1
465
ø14
L2/
N
LOAD
L1
L1
40
=
660±3
840±3
20+1
=
SSB0998-R
282 04/02
4-Line Filters
B84144
for Converters and Power Electronics
Maßbild B84144-G1600-S
4 x M8 x 7
4 x M8 x 7
360±0,8
11±0,5
680+4
L2
L1
N
N
PE M12 x 30
65
38
PE M12 x 30
28
8
N
78
163
211
290 _ 3
240±0,8
L3
262
340±1
ø12
40
L3
L3
Marking
L2/
N
LINE
50+10
400+3
440±1
465
ø14
L2/
N
LOAD
L1
L1
40
=
690±3
870±3
20 +1
=
SSB0999-Z
283 04/02
4-Line Filters
B84144
for Converters and Power Electronics
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
B84144-A16-R … -A36-R
SSB1677-Q
100
αe
B84144-A50-R
dB
αe
80
60
60
40
40
20
20
10 5
10 6
10 7
0
10 4
Hz 10 8
f
B84144-A80-R
SSB1090-F
dB
10 6
10 7
Hz 10 8
f
αe
dB
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
10 5
10 6
10 7
Hz 10 8
f
SSB1091-N
100
80
0
10 4
10 5
B84144-A120 … -A150-R
100
αe
dB
80
0
10 4
SSB1678-Y
100
0
10 4
10 5
10 6
10 7
Hz 10 8
f
284 04/02
4-Line Filters
B84144
for Converters and Power Electronics
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
B84144-A180-R
B84144-G250-S … -G1600-S
SSB1092-W
100
αe
dB
αe
80
SSB1000-K
100
dB
80
70
60
60
50
40
40
30
20
20
10
0
10 4
10 5
10 6
10 7
Hz 10 8
f
0
10 4
285 04/02
10 5
10 6
10 7
Hz 10 8
f
Herausgegeben von EPCOS AG
Unternehmenskommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
++49 89 636 09, FAX (0 89) 636-2 26 89
(
 EPCOS AG 2002. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser
Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet.
Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente
können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir
unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen.
Published by EPCOS AG
Corporate Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
++49 89 636 09, FAX (0 89) 636-2 26 89
(
 EPCOS AG 2002. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited.
Purchase orders are subject to the General Conditions for the Supply of Products and Services of
the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic
Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
1