Model 355 - Honeywell Test and Measurement Sensors

Model 355
Flush Diaphragm Pressure Transducer
DESCRIPTION
Subminiature Model 355 gage pressure transducer is a rugged,
ly amplified Model 355 accepts input voltage from 9 Vdc to 32
one-piece, stainless steel unit which features a flush diaphragm
Vdc and delivers a high level 4 mA to 20 mA or 0 V to 5 V output.
design, making it ideal for operations which involve the spraying
The Model 355 is all welded and hermetically sealed for reliable
or application of sealants, paints, coatings or other congealable
performance in corrosive environments.
media which can clog conventional pressure ports. The internal-
FEATURES
•
0 psig to 500 psig to 0 psig to 5000 psig
•
Flush diaphragm
•
High level output
•
No dead volume
•
±0.50 % accuracy
•
Intrinsically safe available (2N option only)9
•
CE approved10
Model 355
PERFORMANCE SPECIFICATIONS
RANGE CODES
Characteristic
Measure
Range Code
Available ranges
Pressure ranges
0 psig - 500 psig to 0 psig - 5000 psig
CR
500 psi
Accuracy
±0.50 %7
CT
750 psi
Non-linearity
0.5 %
CV
1000 psi
Non-repeatability
0.1 %
DJ
1500 psi
Output
4 mA to 20 mA (std)
Infinite
DL
2000 psi
Resolution
DM
2500 psi
DN
3000 psi
DR
5000 psi
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-29 °C to 85 °C [-20 °F to 185 °F]
Temperature, compensated
15 °C to 71 °C [60 °F to 160 °F]
Temperature effect, zero
0.01 % full scale/°F
Temperature effect, span
0.02 % reading/°F
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Excitation (calibration)
4 mA to 20 mA,
two wire (std.)
9 Vdc to 32 Vdc
0 Vdc to 5 Vdc,
three wire (opt. 2c)
9 Vdc to 28 Vdc
Insulation resistance
50 mOhm @ 50 V
Electrical termination (std)
PTIH-10-6P
Mating connector (not incl.)
PT06A-10-6S (AA111)
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Media
Gases, liquids compatible with 17-4
PH SS
Overload, safe
300 % over capacity
Overload, burst
500 % over capacity or 20000 psi,
whichever is less
Pressure port
7/16-20 UNF
Wetted parts material
17-4 PH stainless steel
Case material
Stainless steel
OPTION CODES
Range Code
Many range/option combinations are available in
our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Pressure ranges
500, 750, 1000, 1500, 2000, 2500, 3000, 5000
psi
Temperature
compensation
1a. 60 °F to 160 °F
1b. 30 °F to 130 °F
1c. 0 °F to 185 °F
Internal
amplifiers
2k. 4 mA to 20 mA, two-wire output
2c. 0 Vdc to 5 Vdc
2n. (2N) 4 mA to 20 mA (two wire output),
intrinsically safe
Pressure ports
5p. M12 x 15 male
5d. 7/16 -20 UNF male
Electrical
termination
6a. Bendix PTIH-10-6P
(orequivalent) 6 pin
(max 250 °F)
6e. Integral cable: Teflon (-54 °C to 245 °C)
6f. Integral cable:
PVC (-30 °C to 70 °C)
6h. Integral cable:
Silicone (-54 °C to
150 °C)
Special
calibration
9e. CE mark
9a. 10 point (5 up/5 down)
20 % increments @ 20 °C
9b. 20 point (10 up/10 down)
10 % increments @ 20 °C
Interfaces
53e. Signature calibration
53t. TEDS IEEE 1451.4 module8
1d. -20 °F to 130 °F
1j. 0 °C to 50 °C
1k. -20 °C to 85 °C
6i. Integral underwater
cable, 8m (max 80 °C)
6n. DIN 40050
6q. Molded integral
cable: Polyurethane
6v. Phoenix connector
on end of cable
SPECIAL REQUIREMENTS (CONSULT FACTORY)
2 Honeywell • Sensing and Control
Have a special requirement? New case pressure, different cable lengths,
electrical connectors, or materials? Consult our factory by calling +1
614-850-5000 (800-848-6564). Customization is key to our test and
measurement business. Special outputs, wiring codes, and calibrations
are all standard to us.
Flush Diaphragm Pressure Transducer
INTERNAL AMPLIFIERS
Amplifier
specifications
Vehicle voltage output:
Option 2c
Current two-wire:
Option 2k
Intrinsically safe amp:
Option 2N (2n)***
Output signal
0 Vdc to 5 Vdc @ 45 mA
4 mA to 20 mA
4 mA to 20 mA
Input power (voltage)
11 Vdc to 28 Vdc
9 Vdc to 28 Vdc
9 Vdc to 28 Vdc3
Input power (current)
40 mA
4 mA to 28 mA
4 mA to 24 mA
Frequency response
3000 Hz
300 Hz
2000 Hz
Power supply rejection
60 db
60 db
60 db
Operating temperature
-20 °F to 185 °F
0 °F to 185 °F
-20 °F to 185 °F
Reverse voltage protection Yes
Yes
Yes
Short circuit protection
Momentary
Yes
Yes
Wiring code: connector
A
B
C
D
E
F
A
B
C
D
E
F
A
B
C
D
E
F
Wiring code: cable3,5,6
R (+) Supply
Bl Output com*
G Supply ret.*
W (+) Output
B No connection
Br No connection
(+) Supply
Output com.**
Supply ret.**
(+) Output
No connection
No connection
3
(+) Supply
No connection
No connection
(+) Output
Case ground
No connection
R (+) Supply
Bl (+) Output
W Case ground
(+) Supply
No connection
No connection
(+) Output
Case ground
No connection
R (+) Supply
Bl (+) Output
W Case ground
* Black and green wires are internally connected.
** Pins B and C are internally connected.
*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals. Ref #008-0547-00.
INSTALLATION AND MOUNTING
MOUNTING DIMENSIONS AND CHARACTERISTICS
The Model 355 has straight threads and uses a #12 O-ring for
pressure sealing. To get the best seal with the O-ring on the
transducer, the tapped hole should have the dimensions shown
here. For normal operating temperatures [-65 °F to 250 °F] use
the BUNA-N (black) O-rings. For high temperatures [250 °F to
425 °F] use silicone rubber (red). Maximum torque is 50 in.-lb.,
17-4 PH stainless steel only.
For reference only
TYPICAL SYSTEM DIAGRAM
Customer supplied
Chart recorder
Alarm panel
Data acquisition
Computer
PLC
Model 355
Mating connectors & cables
PT06A-10-6S (4 conductor cable), std.
PT06E-10-6S (4 conductor cable)
Display units
SC500
SC2000
SC2001
SC3004
GM-A
Honeywell • Sensing and Control
3
Model 355
Flush Diaphragm Pressure Transducer
NOTES
1. Gage pressure units greater than 500 psi are sealed at atmospheric
pressure.
2. Input power (voltage) for internal amplifier options 2j, 2k, 2n (2N)
depends on load resistance.
3. Interconnecting shunt cal. 1 with shunt cal. 2 terminal provides 50 %
(unamplified units), 75 % (4 mA to 20 mA, three wire units), or 80 %
(voltage amp. units) of full scale output for quick
calibration. Shunt calibration comes standard with internal amplifier
options 2a, 2b, 2c, 2t and 2j.
4. Not available with temperatures below -29 °C [-20 °F] or above 85 °C
[185 °F].
5. G=Green; B=Blue; W=White; Bl=Black; Br=Brown; Y=Yellow; R=Red;
O=Orange. Color specifying cable and number or letter specifying
connector.
6. No mating connector necessary with cable option.
7. Accuracies stated are expected for best-fit straight line for all errors
including linearity, hysteresis & non-repeatability thru zero.
8. Consult factory for TEDS availability with amplified models.
9. Range dependent; consult factory. Termination dependent; consult
factory.
10.CE approved only with 2N option.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
WARNING
PERSONAL INJURY
•DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
Find out more
WARNING
Honeywell serves its customers
MISUSE OF DOCUMENTATION
through a worldwide network of
•The information presented in this datasheet is for
reference only. DO NOT USE this document as product
installation information.
•Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
sales offices, representatives
and distributors. For application
assistance, current specifications, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
Failure to comply with these instructions could result in
death or serious injury.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
http://measurementsensors.
honeywell.com, or e-mail inquiries to [email protected]
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
sensing.honeywell.com
008679-2-EN IL50 GLO May 2014