AXIOM25-50-50_Rev1-27.000MHz

Designed and
Manufactured
in Germany
Specification
Oscillator type:
Rev.: 1
Date: 2014-07-08
AXIOM25
OCXO in DIL14 Package with Sine Wave Output
Parameter
min.
Frequency range
Standard frequencies
Frequency stability
Initial tolerance @+25°C
vs. operating temperature range
(steady state)
10
80
10.000 / 12.800 / 16.384
operating temperature range
vs. supply voltage variation
vs. load change
st
Long term (aging) 1 year (Note 3)
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
-10
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load RL
Output level
Harmonics
Warm-up time
Supply voltage VS
typ.
max.
Condition
±100
±200
±300
±500
+60
±10
±20
±0.5
MHz
MHz
ppm
ppb
ppb
ppb
ppb
ppb
°C
ppb
ppb
ppm
VC @ centre value
Option II =”100”
Option II =”200”
Option II =”300”
Option II =”500”
(Note 2)
VS ±5%
RL ±10%
@ +40°C, after 30 days
±5
3.15
4.75
ppm
V
V
Option I = “33”
Option I = “50”
±500
±2
0.15
0.25
1.65
2.5
Positive
100
kΩ
Sine wave
50
+3
3.13
4.75
-30
2
3.47
5.25
300
200
800
500
+75
+85
3.3
5.0
Current consumption (steady state)
@ +25°C
Current consumption (warm-up)
-30
-40
Operable temperature range
Storage temperature range
20.7x13.1x8.5 max.
Enclosure (see drawing) (LxWxH)
Weight
Packing
Notes:
1.
2.
3.
Unit
5
Ω
dBm
dBc
min
V
V
mA
mA
mA
mA
°C
°C
mm
g
±10%
∆ffinal/f0 < ±0.1 ppm
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
IEC 60679-3 CO 02
Palette or Tube
Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Operating temperature range –20°C to +70°C on request
st
Aging of ± 0.2 ppm / 1 year on request
Ordering Code:
Model (Specification)
AXIOM25
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Option I
50
Option II
100
Revision
Rev.1
AXIOM25 Rev.1
Drawing D1
Page 1(2)
Frequency [MHz]
10.000
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Enclosure drawing
Pin connections
Pin #
1
7
8
14
Symbol
VC
GND
RF OUT
VS
Function
Control Voltage (EFC)
Ground
RF Output
Supply Voltage
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
Vibration,
2-6
5.6.7.1
201A
sinusoidal*
204D
Vibration,
2-64
5.6.7.3
214A
random*
Endurance tests
108A
- ageing
5.7.1
- extended aging
5.7.2
Other environmental conditions on request
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
3.6.52
3.6.48
516.4
3.6.40
516.4-4
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
514.5
4.8.35
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice.
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
1
1
D0
D1
05.07.2005
08.07.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
First issue
Editorial changes
AXIOM25 Rev.1
Drawing D1
Page 2(2)
Author
Checked
BN
HH
BN
HH
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]