C1005B-Series - Carling Technologies

C1005B-Series
THERMAL CIRCUIT PROTECTORS
The C1005B-Series offers the functionality of a switch and
circuit breaker in a single compact package, which fits an
industry standard. 500 x 1.125 mounting hole. This combo
device eliminates the need for both a switch and thermal
circuit protector on customer panels. By using only
this multipurpose product, wiring and assembly costs
are greatly reduced, while at the same time, valuable
panel real estate is saved.
The C1005B-Series is available lighted or unlighted, in
a variety of colors, with solder lug or .250 Tabs. Current
ratings range from 7-16 amps@125 and 250 VAC and
up to 32 VDC.
Product Applications:
Household and Commercial Appliances
Transportation
Marine
Telecommunications
Power Strips
Audio-visual Equipment
Medical equipment
Power supplies
Generators
Safety Regulatory Agency Approvals:
UL, CUL, TUV
Product Bulletin #125RN
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062-1177
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
Product Highlights:
Industry Standard .550 X 1.125 mounting hole (14mm X
28.6mm)
ŠŠ Ratings from 7-16 Amps
ŠŠ Standard Reset/Off Legend
ŠŠ Aesthetically pleasing Curved Rocker & Angular Bezel
ŠŠ .250 Tabs or Solder Lug Terminations
ŠŠ 65°C Max Operating Temperature
ŠŠ 1000 AIC Interrupting Capacity
ŠŠ 1500 VAC Dielectric Strength
ŠŠ 100 megohms at 500 VDC Insulation Resistance
ŠŠ Compact Space-saving Envelope
ŠŠ UL1077, UL1363, IEC 60934
ŠŠ
2 | C1005B-Series - Ordering Scheme
C1005B — 3 B 15 1 B R 3
1
Series
2
3
4
Illumination Termination Current
Rating
5
Contact
Material
6
Bezel
Legend
7
Rocker
Color
8
Lamp
Voltage
5 CONTACT MATERIAL1
1 SERIES
C1005B
1
3
2 ILLUMINATION
2
Non-Lighted
3
Lighted
SilverCad Oxide (switch), Silver plated copper (breaker)
SilverCad Oxide (switch & breaker)
6 BEZEL LEGEND IMPRINT
B
W
C
3 TERMINATION
A
Solder Lug
B
.250 Tab
Black Bezel with white legend
White Bezel with black legend
Gray Bezel with black legend
7 ROCKER COLOR
4 CURRENTRATING (AMPERES)
07
7 amps
08
8 amps
09
9 amps
10
10 amps
11
11 amps
12
13
14
15
16
R
G
U
T
12 amps
13 amps
14 amps
15 amps
16 amps
Note: RESET OFF Legend is standard.
8 LAMP VOLTAGE
3
9
Notes:
1 Silver cad oxide switch and breaker contacts are available as a special order.
Specify 3 for selection 5
Time Delay
Red
Green
Blue
Clear
Neon Lamp 125/250 VAC
Non-lighted
Dimensional Specifications: in. [mm]
OVERLOAD TRIP TIME
100%
NO TRIP
150%
TRIP IN 1 HR.
200%
5 - 35 SEC.
300%
1 - 10 SEC.
400%
.45 - 5.5 SEC.
600%
.1 - 20 SEC.
1.280 [32.5]
1.125 [28.6]
.669 [17]
.858 [21.8]
.550 [14]
PANEL CUT OUT
.07 [1.79]
CORRECTION FACTOR1
0C
10 C
15 C
18 C
25 C
32 C
40 C
50 C
60 C
o
o
o
o
o
o
o
o
o
x .67
x .72
x .83
x .87
x 1.00
x 1.05
x 1.18
x 1.33
x 1.67
.921 [23.4]
.236 [6]
.472 [12]
.0315 [.8]
.394 [10]
.394 [10]
1.102 [28]
.248 [6.17]
.532 [13.5]
Notes:
1 To adjust the breaker ratings for ambient temperature multiply the breaker rating by the factor.
(ex: 5 amp rating at 0°C: 5 x .67 = 3.3 amp.
Select 3 amp rating.)
2500 amps @ 32 VDC only. AIC rating is 1000
amps for AC applications.
*Manufacturer reserves the right to change product specification without prior notice.
REV_CB_CLB_0212
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com