FEATURES
· 0...-1 to 0...16 bar, 0...-15 to 0...250 psi
gage1 or absolute11
· For corrosive media
· Flush mount versions
· 0...10 V, 1...6 V, 0...20 mA, 4...20 mA
output
· Field interchangeable
· For harsh environments
MEDIA COMPATIBILITY
Wetted materials:
Stainless steel 1.4404 (316L), NBR12
Housing:
Stainless steel 1.4404 (316L), protection class IP 65
(according to DIN EN 60529, NEMA 4X)1
ELECTRICAL CONNECTION
0...10 V, 1...6 V output
+Vs
SPECIFICATIONS9,10
sensor
Maximum ratings
3
-Vs
2
Supply voltage (reverse polarity protection)
BTE(M)/PTU6...0, ...1
13...30 V
BTE(M)/PTU6...4, ...52
12...36 V
Maximum load current
BTE(M)/PTU6...0, ...1
10 mA
-55...100°C
-40...100°C
0...70°C
Humidity limits
0...95 %RH
Mechanical shock
Proof pressure3
10 gRMS
sensor
GND
12 to 36 V
RL
V
GND
4...20 mA output
50 g
2 x rated pressure
+Vs
1
Iout
3
-Vs
2
sensor
+Vs
1
N/C
3
-Vs
2
E / 11102 / B
V
0...20 mA output
Temperature limits
Storage
Operating
Compensated
Vibration (5 to 500 Hz)
13 to 30 V
1
Vout
12 to 36 V
V
RL
GND
1/6
www.first-sensor.com
www.sensortechnics.com
BTE6000 / PTU6000 Series
Precision stainless steel pressure transmitters
COMMON PERFORMANCE CHARACTERISTICS1
Characteristics
Min.
Thermal effects (0 to 70°C)4
200/300 mbar, 3/5 psi only
Thermal effects (-40 to 0°C, 70 to 100°C)
Non-linearity (BSL) and hysteresis5
Repeatability
Long term stability6
Output noise (0 < f < 1 kHz)
Response time (10 to 90 %)
Power supply rejection
Offset
Span
Offset
Span
Offset
Span
Typ.
Max.
±0.01
±0.01
±0.03
±0.03
±0.06
±0.04
±0.03
±0.03
±0.1
±0.1
±0.2
±0.04
1
±0.05
±0.05
Offset
Span
Unit
%FSO/°C
±0.5
%FSO
ms
%FSO/V
INDIVIDUAL PERFORMANCE CHARACTERISTICS1
0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
Full scale span7
BTE/PTU6N...
all others
BTE/PTU6N...
all others
Min.
Typ.
Max.
4.85
-0.15
4.9
9.9
5.0
0
5.0
10.0
5.15
0.15
5.1
10.1
50
Output impedance
Power consumption (no load)
100
Unit
V
Ω
mW
1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
3.35
0.85
2.4
4.9
Output impedance
3.5
1.0
2.5
5.0
6.0
3.65
1.15
2.6
5.1
50
Power consumption (no load)
100
Zero pressure offset
Full scale span7
BTE/PTU6N...
all others
BTE/PTU6N...
all others
Unit
V
Ω
mW
4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Unit
11.85
3.85
7.9
15.9
12.15
4.15
8.1
16.1
mA
Output impedance
12.0
4.0
8.0
16.0
0.1
Power consumption (IL = 20 mA)
260
Zero pressure offset
Full scale span7
E / 11102 / B
BTE/PTU6N...
all others
BTE/PTU6N...
all others
Ω
mW
2/6
www.first-sensor.com
www.sensortechnics.com
BTE6000 / PTU6000 Series
Precision stainless steel pressure transmitters
INDIVIDUAL PERFORMANCE CHARACTERISTICS1 (cont.)
0...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Unit
9.85
-0.15
9.9
19.9
10.15
0.15
10.1
20.1
mA
Output impedance
10.0
0
10.0
20.0
0.1
Power consumption (IL = 20 mA)
260
Zero pressure offset
BTE/PTU6N...
all others
BTE/PTU6N...
all others
Full scale span7
Ω
mW
ELECTROMAGNETIC CAPABILITY8
Radiated, radio frequency
electromagnetic field immunity (RFI)
Electrical fast transient /
burst immunity (EFT)
Electrostatic discharge immunity
test (ESD)
Immunity to conducted disturbances
induced by radio-frequency fields
Test conditions
10 V/m, 80 to 1000 MHz
80 % AMC (1 kHz)
EN61000-4-4: ±2 kV
Criterion Interference
EN61000-4-3:
EN61000-4-2:
EN61000-4-6:
±4 kV, contact discharge
±8 kV, air discharge
0.15 to 80 MHz
10 V, 80 % AMC (1 kHz)
A
<1 %FSO
B
<1 %FSO
B
<1 %FSO
A
<1 %FSO
LOAD LIMITATION
RECOMMENDED ACCESSORY
0...20 mA output version
4...20 mA output version
Plug DIN EN 175301-803 A and profile washer included
in delivery. For a complete connector/cable assembly
use order no. ZK000110-x (x=cable lenghts in m).
1400
Ohm
1200
50
1000
34
800
600
operating
range
Profile washer
400
M3
31
200
0
5
10
15
20
25
30
35 V
supply voltage
E / 11102 / B
dimensions in mm
Note:
For proper function of all gage devices the
gage port must be vented to the atmosphere
through the connector/cable assembly.
3/6
www.first-sensor.com
www.sensortechnics.com
BTE6000 / PTU6000 Series
Precision stainless steel pressure transmitters
OUTPUT CHARACTERISTICS
1...6 V output version
0...10 V output version
10
Vout
V 9
10
Vout 9
V
8
8
BTE/PTU6N...
7
7
6
6
5
5
4
all others
BTE/PTU6P...
4
3
3
2
2
1
1
-100 -80 -60 -40 -20
0 +20 +40 +60 +80 +100 %
operating pressure
4...20 mA output version
BTE/PTU6P...
all others
-100 -80 -60 -40 -20
0 +20 +40 +60 +80 +100 %
operating pressure
0...20 mA output version
20
20
Iout 18
mA
16
BTE/PTU6N...
Iout 18
mA
16
14
14
12
12
10
BTE/PTU6N...
BTE/PTU6P...
8
all others
4
2
2
E / 11102 / B
0 +20 +40 +60 +80 +100 %
operating pressure
all others
6
4
-100 -80 -60 -40 -20
BTE/PTU6N...
10
8
6
BTE/PTU6P...
-100 -80 -60 -40 -20
0 +20 +40 +60 +80 +100 %
operating pressure
4/6
www.first-sensor.com
www.sensortechnics.com
BTE6000 / PTU6000 Series
Precision stainless steel pressure transmitters
OUTLINE DRAWING
BTE6...
25.0
(0.98)
17.0
(0.67)
NOM 83.0
(NOM 3.27)
12.0
(0.47)
1
vent hole
8.5
(0.33)
27.0 (1.06)
diam.
6.0 (0.24)
G1/2" (BSP)
HEX27 ( 1 1/8)
3
2
mass: 230 g
1
dimensions in mm (inches)
BTE6...-FL
NOM 86.5
(NOM 3.41)
NOM 13.0 (NOM 0.51)
12.0
(0.47)
vent hole
27.0 (1.06)
diam.
23.0 (0.91)
diam.
mass: 250 g
2
PTU6...
17.0 (0.67)
1
dimensions in mm (inches)
WARNING
Do not touch diaphragm
NOM 83.0 (NOM 3.27)
8.5 (0.33)
12.0
(0.47)
1
vent hole
3
27.0 (1.06)
diam.
1/4"-18 NPT
HEX27 ( 1 1/8)
1
3
G3/4" (BSP)
HEX32 ( 15/16)
NOM 3.0 (NOM 0.12)
12.0
(0.47)
2
mass: typ. 280 g
1
dimensions in mm (inches)
PTU6...-FL
12.7 (0.5)
2.7 (0.1)
NOM 86.5 (NOM 3.41)
12.0
(0.47)
12.0 (0.47)
mass: typ. 190 g
E / 11102 / B
27.0 (1.06)
diam.
Ø22,5 ± 0,05
3
1-12UNF
HEX32 ( 15/16)
1
vent hole
WARNING
Do not touch diaphragm
2
1
dimensions in mm (inches)
5/6
www.first-sensor.com
www.sensortechnics.com
BTE6000 / PTU6000 Series
Precision stainless steel pressure transmitters
Specification notes:
1. IP 65 protection is given when the connector is locked with a rubber washer. For proper function the gage port is vented to
the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure.
2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C.
5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
6. Long term stability is the change in output after one year or 1 million pressure cycles.
7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
8. Test are in accordance with EN 61000-6-2.
9. CE-labelling is in accordance with 2004/108/EC.
10. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
11. Available for pressure ranges from 1 bar (15 psi) absolute upwards only.
12. Other sealing materials are available on request.
ORDERING INFORMATION
BTE/PTU
(M)
6xxx
x
x
(-FL)
Calibration/Pressure connection
BTE: mbar/bar calibration,
1/2" manometer thread
(3/4" thread for flush mount versions)
PTU: psi calibration,
1/4" NPT thread
(1-12 UNF thread for flush mount versions)
Flush mount version
For mbar ranges only
Pressure mode
G: gage pressure1
A: absolute pressure
(from 1 bar/15 psi)
Pressure range
BTE6000 series
200: 0...200 mbar
350: 0...350 mbar
001: 0...1 bar
N01: -1...+1 bar
P01: 0...-1 bar
002: 0...2 bar
005: 0...5 bar
010: 0...10 bar
016: 0...16 bar
PTU6000 series
003: 0...3 psi
005: 0...5 psi
015: 0...15 psi
N15: -15...+15 psi
P15: 0...-15 psi
030: 0...30 psi
100: 0...100 psi
250: 0...250 psi
Output signal
0: 0...10 V
1: 1...6 V
4: 4...20 mA
5: 0...20 mA
Other pressure ranges and options are widely available. Please contact First Sensor.
First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application
or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.