ELP25 series

ELP25
2 5 W L E D D r i v e r with PFC
series
Universal Input to 305 VAC
High Efficiency (Up to 84%)
Active Power Factor Correction (typ 0.94)
Constant Output Current
Waterproof (IP66)
All-Round Protection: OVP, SCP, OLP
Complies with UL8750 & EN61347 Safety Regulations
Optional Dimmer Control Feature
Model Number
Output Voltage Range Output Amps Range Efficiency @ 220Vin
Over Voltage Protection
*ELP25-1212(D or P)
*ELP25-1214(D or P)
*ELP25-1218(D or P)
*ELP25-1224(D or P)
*ELP25-1236(D or P)
*ELP25-1240(D or P)
*ELP25-1256(D or P)
*ELP25-1272(D or P)
4-12Volts(DC)
5-14Volts(DC)
6-18Volts(DC)
8-24Volts(DC)
12-36Volts(DC)
13-40Volts(DC)
19-56Volts(DC)
24-72Volts(DC)
13~18 Volts(DC)
16~20 Volts(DC)
21~24 Volts(DC)
26~30 Volts(DC)
42~46 Volts(DC)
44~48 Volts(DC)
59~62 Volts(DC)
82~90 Volts(DC)
1.976-2.184 Amps
1.663-1.838 Amps
1.33-1.47 Amps
0.998-1.103 Amps
0.665-0.735 Amps
0.589-0.651 Amps
0.428-0.473 Amps
0.333-0.368 Amps
80%
80%
82%
82%
83%
83%
84%
84%
* Note:
The Asterisk * denotes a choice of receiving this product WITH a Dimmer Control Feature (D) or WITHOUT the Dimmer Control Feature (P). Simply add the letter “D”
or “P” to the end of the model number (i.e. “ELP25-1212D” or “ELP25-1212P”) when ordering to receive the desired version.
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
ELP25
2 5 W L E D D r i v e r with PFC
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Input Current
Inrush Current
GENERAL SPECIFICATIONS
90-305VAC
47-63 Hz
0.32 Amps max @ 100VAC
0.15 Amps max @ 220VAC
20A @ 230VAC, 25°C Cold Start
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation
Load Regulation
Ripple/Noise
Turn-on Delay Time
Output Overshoot / Undershoot
Over Voltage Protection
Short Circuit Protection
Over Load Protection series
See Selection Chart
2.0%
5.0%
25% pk-pk / 20MHz bandwidth
0.1uF ceramic capacitor
10uF eletrolytic capacitor
1.7S @ 110VAC
10% When power on or off
See Selection Chart
Hiccup mode. Auto-Recover
No damage shall occur when any
output operating in a short circuit condition. The power supply
shall self-recover when the fault
condition is removed
125% of Po
Hiccup mode. Auto-Recover
Safety (Note 1)
USA & Canada
UL8750 Compliance to UL1310 Class 2, UL1012, UL935, CAN/CSA-C22.2 No. 0, CSA-C22.2
No. 107.1, CSA-C22.2 No. 250.0
CE Europe
EN61347-1, EN61347-2-13
EMI
EN55015
Efficiency
See Selection Chart
EMS
Compliance to
EN61000-4-2,3,4,6,8,11;
EN61000-3-2,3
EN61547
No load Power Dissipation ≤5.0W
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
MTBF
Life Time
-20°C to +70°C 10~100% RH (See Derate Curve)
-40°C to +85°C, 5~100% RH
484KHrs min, min @ 80% Load,
MIL-HDBK-217F (25°C) /110VAC
79K Hrs; 110VAC, 25°C, 80% Load
PHYSICAL SPECIFICATIONS
Size
Millimeters
78 x 80 x 25
Inches
3.07” x 3.15” x 0.98”
Weight
7.05 oz (200g)
Note
1) 12-36 Volt outputs are Class 2 U.S. and Canada
The 40 Volt output is Class 2 U.S. ONLY
ALL others are NOT Class 2
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
ELP25
2 5 W L E D D r i v e r with PFC
series
Derating Curves
Derating Curve
100
100
80
80
Load(%)
Load(%)
Derating Curve
60
40
20
0
60
40
20
-20
-5
10
25
40
Ambient Temperature(°C)
55
70
0
90
120
150
180
210
240
270
300
330
Input Voltage(V)
Mechanical Outline
ELP25-xxxxP
AC INPUT (2*AWG #18)
WHITE (ACN)
BLACK (ACL)
DC OUTPUT (2*AWG #18)
RED (V+)
BLACK (V-)
Unspecified tolerance: ±0.2
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
ELP25
2 5 W L E D D r i v e r with PFC
series
ELP25-xxxxD
AC INPUT (2*AWG #18)
WHITE (ACN)
BLACK (ACL)
Dimming control wire (3*AWG #22)
DC OUTPUT (2*AWG #18)
YELLOW (10V OUTPUT)
RED (V+)
BLACK (V-)
PURPLE (0~10V INPUT)
GREEN (GND)
Unspecified tolerance:±0.2
Dimming Control (On secondary side)
Parameter
Min.
Typ.
Max.
9.8 V
10 V
10.2 V
10V output source current
-10 mA
-
2 mA
Absolute maximum voltage
on the 0~10V input pin
-2 V
-
15 V
Source current on 0~10V input pin
0 mA
-
1 mA
10V output voltage
Notes
The dimmer control may be operated from either a potentiometer or from an input signal of 0 – 10 Vdc.
Two recommended implementations are provided below.
100%
90%
ELP25-xxxxD
output current
80%
70%
60%
50%
40%
30%
20%
10%
0%
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
Dimming control
Implementation 1: Potentiometer Control
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
ELP25
2 5 W L E D D r i v e r with PFC
series
100%
90%
output current
80%
ELP25-xxxxD
70%
60%
50%
40%
30%
20%
10%
0%
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
DC Input
Implementation 2: DC input
Notes:
1. For the driver to operate properly, the load voltage must be maintained above the minimum voltage
threshold (approx. 33% of the max. output voltage for any given model).
2. If the input voltage is within 90-175Vac, the
output current can be varied from 100% down
to 10%. (Refer to right figure)
Output voltage(Vo)
Vo
Vo/3
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Output current(%)
Io
3. If the input voltage is within 175-305Vac, the
output current can be varied from 100%
down to 20%. (Refer to right figure)
Output voltage(Vo)
Vo
Vo/2
Vo/3
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Io
Output current(%)
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458