SD500 series

SD500
5 0 0 W S i n g l e O u t put DC-DC Converter
series
DC Input Active Surge Current Limiting
Wide 4:1~2:1 DC Input Range
Protections: Short circuit / Overload / Over voltage / Over
Temperature/ Input Polarity(by fuse)
2000VAC I/O Isolation
Forced Air Cooling by Built-In DC Fan with Fan Speed
Control Function
Output OK Signal
Built-In Remote ON-OFF Control
Built-In Remote Sense Function
Model Number
Output Volts
Output Amps
Min Load
DC Volt Adjust
Efficiency
Over Voltage Protection
12 Volts(DC)
24 Volts(DC)
48 Volts(DC)
12 Volts(DC)
24 Volts(DC)
48 Volts(DC)
40 Amps
21 Amps
10.5 Amps
40 Amps
21 Amps
10.5 Amps
0~40Amps
0~21Amps
0~10.5Amps
0~40Amps
0~21Amps
0~10.5Amps
11~15Volt(DC)
23~30Volt(DC)
46~60Volt(DC)
11~15Volt(DC)
23~30Volt(DC)
46~60Volt(DC)
86%
88%
89%
87%
89%
90%
16~19Volts(DC)
30.8~35.2Volts(DC)
62~68Volts(DC)
16~19Volts(DC)
30.8~35.2Volts(DC)
62~68Volts(DC)
SINGLE OUTPUT
SD500L-12
SD500L-24
SD500L-48
SD500H-12
SD500H-24
SD500H-48
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
SD500
5 0 0 W S i n g l e O u t put DC-DC Converter
series
INPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Input Voltage Range (Note 3)
SD500L-xx: 19~72Volts(DC)
SD500H-xx: 72~144Volts(DC)
Inrush Current, typ:
60Amps (DC)
Input Current FL, typ:
SD500L-xx:
24.2Amps/ 19 Volts(DC)
24.8Amps/ 24 Volts(DC)
12Amps/ 48 Volts(DC)
SD500H-xx:
8Amps/ 72 Volts(DC)
6Amps/ 96 Volts(DC)
Input Current NL, typ:
SD500L-xx:
0.2Amps/ 48 Volts(DC)
SD500H-xx
0.1Amps/ 96 Volts(DC)
Min Load
See Selection Chart
Safety
Insulation Resistance
EMI
Remote Control
Output OK Signal
Efficiency
Isolation
EMS (Note 4)
OUTPUT SPECIFICATIONS
Voltage and Current See Selection Chart
Line Regulation
±0.5%
Load Regulation
±0.5%
Voltage Tolerance (Note 2) ±1.0%
Ripple/Noise (Note 1)
150mVpk-pk max.
Setup, Rise Time
500ms, 50m @ FL
Over Voltage Protection
See Selection Chart
Shut down o/p voltage, re-power
Over Current Protection
105 ~ 125% rated output power
Constant current limiting, shutdown o/p
voltage, re-power Over Temperature
80°C±5°C TSW1 detect on heatsink of power transistor
80°C±5(L-48V,H-24V,H-48V), 85°C±5(L-24V)
90°C±5(L-12V), 95°C±5 (H-12V) TSW2 : detect on heatsink of o/p diode. Shutdown o/p voltage auto recov after cool down
DC Volt Adjust
See Selection Chart
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
IEC60950-1 CB approved by TUV
≥ 100MΩ / 500Volts(DC) / 25°C / 70% RH
Compliance to EN55022B (CISPR22B)
Please refer to function manual
Open collector signal low when PSU turns on, max. sink current : 10 mAmps
See Selection Chart
2000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to EN61000-4-2, 3, 4, 6, 8
ENV50204, light Industry Level, Criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Relative Humidity
Storage Temperature
Temperature Coefficient
MTBF
Vibration
-20°C to +60°C (See Derate Curve)
20~90% RH non cond
-40°C to +85°C, 10~95% RH
±0.02% / °C (0-50°C) 196.3 KHrs min,MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
(Millimeters / Inches)
Weight
215 x 115 x 50 / 8.46” x 4.53 ” x 1.97 ”
20.46 oz (580g)
NOTE
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Derating may be needed under low input voltages. Please check the
derating curve for more details.
4. The Power Supply is considered a component which will be installed
into final equipment, The final equipment must be re-confirmed that it still
passes EMC directives
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
SD500
5 0 0 W S i n g l e O u t put DC-DC Converter
Assignment
series
Assignment
Hirose
HRS DF11-6DS
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
5 0 0 W S i n g l e O u t put DC-DC Converter
WWW.ASTRODYNE.COM
SD500
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
5 0 0 W S i n g l e O u t put DC-DC Converter
WWW.ASTRODYNE.COM
SD500
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
5 0 0 W S i n g l e O u t put DC-DC Converter
WWW.ASTRODYNE.COM
SD500
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458