SeriesOne DR Timer

The Global Expert in Solid State Switching Technology
ABOUT US
Crydom, a brand of Custom Sensors & Technologies (CST) and global
expert in Solid State Relay Technology, has a distinguished record of
providing high quality, world class Solid State Relay and Control Products
for a variety of heating, lighting and motion control applications. Crydom
products, coupled with unparalleled technical support, timely delivery
and competitive pricing, provide Crydom’s clients with the innovative
products and support necessary to succeed in today’s competitive and
fast paced global markets.
DIN RAIL
MOUNTED AC & DC
OUTPUT SOLID
STATE RELAY TIMERS
SeriesOne DR Single Channel AC & DC
Output Multifunction Timers
Crydom’s proprietary thermal management technology and proven Solid
State Relay expertise are now combined with advanced uP based timing in the
Crydom’s extensive selection of standard off-the-shelf products is
constantly being updated and expanded through its continuous
improvement and aggressive new product development programs.
Utilizing state of the art designs, materials and technology, Crydom offers
a wide range of AC and DC output SSRs and solid state contactors in
industry standard Panel Mount, PCB Mount, DIN Rail and Plug-In
packages, all meeting global safety and standards agency
requirements such as CE, RoHS, UL, IEC, etc.
Bolstered by four decades of Solid State Relay operations experience,
new SeriesOne DR Timer line. Offering models with exceptional Solid State
output ratings of either 6 amp AC or DC and 8 different precision timing
functions with 18 variations the new SeriesOne DR Timer line is housed in a
compact 11 mm wide DIN Rail mounted package designed for the direct
control of a wide variety of resistive and inductive loads.
Multifunction Solid State Relay Timing
with Superior Output Ratings
Ideal for use in control panels for direct control of contactors, solenoids,
fully
motors, heaters, lights, etc., the SeriesOne DR Timer series is available with
custom-designed SSR products for nearly any application where unique
either 6 amp/24 to 280 VAC output rating or 6 amp/1 to 60 VDC output rating,
specifications and optimized performance are critical for success.
both at 40°C ambient temperature…. ratings well in excess of most Solid State
Crydom also specializes and encourages
adapted
and
Relay Output Timers in the market today, therefore allowing direct control of
Crydom’s modern purpose-built 100,000 square foot manufacturing
many loads thus eliminating the need for interfacing power relays often
facility houses all aspects of its ISO certified operation including Design
required for use with lower power timers.
and Development Engineering, Manufacturing Operations and Quality
Assurance, Customer Service, Finance, Marketing and General
Available timing functions include “A” & “At” delay on make, “B” single shot,
Management, permitting close coordination of all aspects of Crydom’s
“C” delay on break, “H” & “Ht” interval, “L” & “Li” repeat cycle, and “U”
activities. Applications Engineering and Sales support are both performed
multifunction that includes A, At, Ac, B, Bw, C, D, Di, H, and Ht functions. Basic
in the field to provide Crydom’s Customers with the unparalleled technical
timing function selection is user settable via screw slot rotary switches on the
and commercial support.
side of the SeriesOne DR Timers, while unit and fine timing adjustments are
made on the front panel of the Timers. This arrangement provides easy
Following rigid design guidelines and standards, Crydom products have
access to Technicians for simple timing adjustments but significantly reduces
set the bench mark for SSR performance and reliability world wide. In
accidental changes to the basic function.
addition to award winning designs, Crydom has acquired an impressive
list of patents related to SSRs and Solid State Controls, while continuing
to develop new circuit and technology-related inventions as part of
extensive R&D programs.
Versatile Control
Control for the SeriesOne DR Timers, depending on model, is 12 to 24
VAC/DC for all models, with options of either 90 to 140 VAC or 180 to 240 VAC
To learn more about Crydom SSR technology and products, or how an
for AC outputs only. All Crydom SeriesOne DR Timers are UL listed and cUL
alliance with Crydom can contribute to the success of your project, visit
recognized, UL Motor Control rated, RoHS and China RoHS compliant, and CE
www.crydom.com or contact your authorized Crydom Distributor or
certified to the Low Voltage and EMC Directives.
Crydom Customer Service Representative today.
For more information, technical support or questions about adapted
assemblies, contact your local Crydom Distributor, Regional Sales Office or
www.crydom.com.
www.crydom.com
SeriesOne DR Timer
DIN Rail Mounted AC & DC Output Solid State Relay Timers
•
•
•
•
•
•
•
•
•
•
Single channel 6 Amps output power rating
Compact Size (11 mm wide)
60 VDC & 280 VAC operating voltage ratings
12-24, 90-140 & 180-240 VAC/DC control input options available
8 Industry standard functions (A/At, B, C, D/Di, H/Ht, L/Li, Ac, Bw)
IP20 Housing with unique integrated heat sink
LED Input/Timer status indicator
AC Output versions with Zero Voltage Turn-On for resistive loads and Random Turn-On for inductive loads
UL Listed & cUL recognized
UL & IEC General Use & Motor Control rated
DRTx24x06x
DRTx06D06
Operating Voltage Range [Vrms]
24-280 VAC (47-440 Hz)
1-60 VDC
Maximum Load Current [Arms]
6
6
Minimum Load Current [Arms]
0.15
2.5 mA
Output Specifications (A)
285/300 (B)
1 Cycle Surge Current (50/60 Hz) @ 25ºC [Apk]
Maximum Surge Current (10ms) @ 25ºC [Adc]
NA
60 (C)
NA
Maximum On-State Voltage Drop @ Rated Current [Vpk]
≤ 1.3 V
≤ 0.6 VDC
Maximum On-State Resistance (RDS-ON) @ 25ºC [Ohms]
NA
0.034
Maximum Off-State Leakage Current @ Rated Voltage [mA]
0.1
0.25 (D)
Transient Overvoltage @ 25ºC[Vpk]
600
NA
Maximum Operating Voltage
NA
1-48 VDC
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
Maximum I²t for Fusing (50/60Hz) @ 25ºC [A² sec]
Minimum Power Factor (with Maximum Load)
UL 508 Resistive Load [A] (E)
500
NA
410/375
NA
0.5
NA
6
6
1/3 / 3.6
NA
IEC 62314 LC-A [FLA]
6
NA
IEC 62314 LC-B [Kw]
1.44
NA
UL 508 Motor Controller [HP/FLA] (E)
DRTx24D06x
DRTx24A06x
DRTx24B06
DRTx06D06
12-24
180-240
90-140
12-24
Minimum Turn-On Voltage [VAC/DC]
12
180
90
12
Must Turn-Off Voltage [VAC/DC]
1
20
10
1
Minimum Input Current (for On-State) [mA ± 10%] (F)
7.6/6.3 @ 12 VAC/DC
7.2/7.1 @ 180 VAC/DC
7.6/7.4 @ 90 VAC/DC
15.7/12.4 @ 12 VAC/DC
Maximum Input Current [mA ± 10%] (F)
12.1/9.1 @ 24 VAC/DC
9.7/9.6 @ 240 VAC/DC
12.5/12.3 @ 140 VAC/DC
27.9/20.3 @24 VAC/DC
Input Specifications (A)
Control Voltage Range [VAC/DC]
Maximum Turn-On Time
Per function (G, H)
Per function (G, H)
Maximum Turn-Off Time
DRTx24x06x
General Specifications (A)
3750
Dielectric Strength, Input-Output to Baseplate (50/60Hz) [Vrms]
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output [pF]
DRTx06D06
109
2500
10
Ambient Operating Temperature Range [ºC]
-30 to 80
Ambient Storage Temperature Range [ºC]
-40 to125
Status Indicator Display
Green (J)
Air Gap (Spacing) ratings (Amps)
6 A / 11 mm or 4.5 A / No Spacing
Weight (typical) in either [oz] (gr)
1.76 (50)
Housing Material
Self-extinguishing
Terminal Finish
Sulfamate Nickel
Humidity
5 to 85%
General Notes
(A) All parameters at 40ºC unless otherwise specified
(B) Tj initial: 25ºC, tp: 8.3 ms
(C) Output Voltage = 2.5 VDC
(D) Output Voltage = 150 V, Control Voltage = 0 V, TJ = 125ºC
(E) For UL listing the housing can not exceed 130ºC or the load terminals exceed 105ºC
(F) Input current varible ± 10% per function
(G) Timing accuracy ± 10%
(H) See TABLE 1 and TABLE 2
(J) See TABLE 3
America
Tel.: +1 (877) 502 5500
[email protected]
To view available Installation Sheet
scan the QR code with your
smartphone or visit www.crydom.com
EMEA
Tel.: +44 (0) 1202 606030
[email protected]
Asia Pacific
Tel.: +86 (0) 21 6065 7725
[email protected]
Part Number Nomenclature
Series
DRT
A
Wiring Diagram (K)
Operating Voltage
06: 60 VDC
24: 280 VAC
24
D
Timing Function
A: A/At, Delay on Make
B: Single Shot
C: Delay on Break
H: H/Ht, Interval
L: L/Li, Repeat Cycle
U: Multifunction
(A/At, H/Ht, D/Di,
B, C, Ac & Bw)
A2
Rated Load Current
06: 6 Amps
06
R
Control Voltage
D: 12-24 VAC/DC
AC
A: 180-240 VAC/DC Output
B: 90-140 VAC/DC
Only
A1
AC/DC CONTROL
VOLTAGE
(Input)
Y1
Switching Type
(24 suffix only)
Blank: Zero Voltage Turn-On
R: Random Turn-On
Required for valid part number
For options only and not required for valid part number
L1
Block Diagram
(+ / )
Load
d
Load
Loa
AC/DC SUPPLY
(Output)
(+ / )
T1
(L)
+1/L1
INPUT
CONTROL
+3/A1
Y1
Mechanical Dimensions
Status
Indicator
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
AC Output Only
TIMER
2.87
[73.0]
4/A2
DC Output Only
0.44
[11.0]
2.02
[51.2]
2/T1
(– / )
Load
(L)
(– / )
TABLE 1. Timer Settings
Identification
3.44
[87.3]
INPUT
STATUS
Side View
5 6 7
4
Di
5 6 7
5 6 7
8 9 10
4
10h100
h
10h100
h
10h100
h
T off
4
10m1
h
1m
T on
Fine Adjustment
1 2 3
1s 10s
8 9 10
4/A2
8 9 10
1 2 3
AcBw
Function
1s 10s
10m1
h
1m
L
Repeat Cycle
Range
Front View
AH
BC
Multifunction
[A/At, H/Ht, D/Di,
B, C, Ac, Bw]
10m1
h
1m
U
1s 10s
1 2 3
Timing
Function
3.27
[83.0]
Fine Adjustment
4WB8
S OLI D S TATE TI MER
INPUT 12-24 VDC
General Use 60VDC/6Arms
@40°C Ambient Temperature
IND. CONT. EQ
+3/A1
A
Delay on Make
Single Shot
Range
5 6 7
4
10h100
h
B
8 9 10
1 2 3
Interval
Y1
1s 10s
10m1
h
1m
H
Fine Adjustment
C
Delay on Break
(K) No grounding wire required. DC inductive loads must be diode suppressed
(L) Load is allowed in either terminal L1 or terminal T1
Complete specifications of these & other Crydom products available at: www.crydom.com
2/T1
DRTL06D06
INPUT
STATUS
1.76
[44.8]
2.59
[65.9]
3.45
[87.7]
+1/L1
Derating Curves
TABLE 2. Timing Ranges (G)
Timing Range
1s
0.1 s to 1 s
10 s
1 s to 10 s
1 min
0.1 min to 1 min
10 min
1 min to 10 min
1h
0.1 h to 1 h
10 h
1 h to 10 h
100 h
10 h to 100 h
DRTxxxx06x
Single or Multi Unit (M)
Multiple Units No Spacing
6
Load Current (Amps)
Identification
5
4
3
2
1
0
0
10
20
30
40
50
60
70
80
Ambient Temperature (ºC)
TABLE 3. LED Status by Function
Function
A/At
Delay On Make
H/Ht
Interval
Control Voltage
Y1
Timing
Repeat Cycle
LED Status
Notes
At function is identical to the A function except when Y1 is connected to A1 timing is paused. When Y1 is
removed timing resumes until relay times out. To reset timer remove control power.
Off
Off
Off
Off
On
On
Off
Long Flashes
Timed Out
On
On
Off
Off
Off
Off
On
On
On
Long Flashes
Timed Out
Off
Off
Off
A
C
At
T
On
On/Off
H
C
C
Ht
T
L/Li
Off
Long Flashes/Short Flashes
L
On/Off
C
D
A1Y1
T
T
T
T
Di
T
T
Single Shot
C
Delay On Break
Ac
Delay On Make /
Delay On Break
Bw
T
T
T
T
L
Long Flashes/Short Flashes
L
C
A1Y1
Toff
Li
Ton Toff Ton Toff
Ton
Off
Open
Off
Off
Off
On
Open
Off
Off
Short Flashes
On
Closed
On
On
Long Flashes
Y1 switch can be momentary or maintained to A1. To
reset timer after relay has timed out Y1 has to be
opened.
Closed
Timed Out
Off
Open
Off
Off
Off
On
Open
Off
Off
Short Flashes
On
Closed
Off
On
On
On
Open
On
On
Long Flashes
On
Open
Timed Out
Off
Short Flashes
Off
Open
Off
Off
Off
On
Open
Off
Off
Short Flashes
On
Closed
On
Off
Long Flashes
On
Closed
Timed Out
On
On
On
Open
On
On
Long Flashes
On
Open
Timed Out
Off
Short Flashes
Off
Open
Off
Off
Off
On
Open
Off
Off
Short Flashes
On
Closed
On
On
Long Flashes
On
Closed
Timed Out
Off
Short Flashes
Ton
Toff
C
B
Y1
T
L
Short Flashes
On
Off
Toff
L
L
B
t3
L
C
On
t2
T=t1+t2+t3
To select between on time (Li) first or off time (L) first Y1 is connected A1. Default is On time (Li) first, for Off
time (L) first connect Y1 to A1. Time delay is independent of each other.
Off
Repeat Cycle
On
t3
To select between on time (Di) first or off time (D) first Y1 is connected. Default is On time (Di) first, for Off
time (D) first connect Y1. Equal On/Off time.
Off
Off
t1
Y1
L
Off
t2
T=t1+t2+t3
L
C
On
t1
Y1
Ht function is identical to the H function except when Y1 is connected to A1 timing is paused. When Y1 is
removed timing resumes until relay times out. To reset timer remove control power.
Short Flashes
Off
C
L
On
On
D/Di
Output State
Y1 switch to A1 must be momentary for timing to
begin. If during timing Y1 is closed again the time
delay is reset and will begin again once Y1 is
removed. Once timed out timer is reset and ready for
the next cycle.
C
To start Delay on Make (A) timing connect Y1 to A1
and maintain until LED is on Solid then to start Delay
on Break (c) portion remove Y1 until relay times out.
Removing Y1 During (A) portion or Connecting Y1
during (c) portion will reset time for that portion.
Ac
Y1 to A1 switch can be momentary or maintained. If
maintained until relay has timed out removing it will
start timing again. If momentary and timers has
timed out reapplying Y1 will start timing again.
Bw
C
Y1
T
L
C
Y1
T
T
L
C
Y1
T
T
L
(M) Minimum spacing between units is 11 mm
America
Tel.: +1 (877) 502 5500
[email protected]
EMEA
Tel.: +44 (0) 1202 606030
[email protected]
Asia Pacific
Tel.: +86 (0) 21 6065 7725
[email protected]
AMERICA
EUROPE, MIDDLE EAST
& AFRICA
United States & Canada
Crydom Inc
2320 Paseo de las Americas,
Suite 201
San Diego, CA 92154
Sales Support:
Tel.: +1 (877) 502 5500
Fax: +1 (619) 210 1590
[email protected]
Technical Support:
Tel.: +1 (877) 702 7700
[email protected]
United Kingdom
Crydom SSR Ltd
Arena Business Centre
Holyrood, Close
Poole, Dorset BH17 7FJ
Sales Support
Tel.: +44 (0) 1202 606030
Fax: +44 (0) 1202 606035
[email protected]
Technical Support
[email protected]
Mexico
American Countries
CST Latinoamerica
Alameda Rio Negro, 1030,
18º andar – Conjunto 1803
CEP: 06454-000
Barueri - São Paulo
Brasil
Tel.: +55 (11) 2505 7500
Fax: +55 (11) 2505 7507
Austria & Switzerland
Italy
Tel.: +44 (0) 1202 606030
Fax: +44 (0) 1202 606035
[email protected]
Tel.: +39 (0) 2 665 99 260
Fax: +39 (0) 2 665 99 268
[email protected]
Belgium
Spain
Tel.: +32 (0) 2 460 4413
Fax: +32 (0) 2 461 2614
[email protected]
France
China & Hong Kong
Custom Sensors &
Technologies Asia
(Shanghai) Ltd.
13th floor
Chang Feng International
Tower
89 Yunling Road (East)
Putuo District
Shanghai, 200062
Sales Support
Tel.: +86 (0) 21 6065 7725
Fax: +86 (0) 21 6065 7749
[email protected]
Technical Support
[email protected]
Tel.: +34 902 876 217
Fax: +34 902 876 219
[email protected]
Netherlands
Tel.: +33 (0) 810 123 963
Fax: +33 (0) 810 057 605
[email protected]
Tel.: +31 (0) 71 582 0068
Fax: +31 (0) 71 542 1648
[email protected]
Germany
Middle East,
Africa & Other European
Countries
Tel.: +49 (0) 180 3000 506
Fax: +49 (0) 180 3205 227
[email protected]
ASIA PACIFIC
Southern & Central
Automatismo Crouzet
S.A. de C.V.
Calzada Zavaleta 2505-C Col
Sta Cruz Buenavista C.P.
72150 - Puebla
Sales Support:
Tel. : +52 (222) 409 7000
Fax : +52 (222) 409 7810
[email protected]
South Korea
Custom Sensors &
Technologies
14F, Kbiz DMC Tower,
189, Seongam-ro, Mapo-gu,
Seoul 121-904, South Korea
Tel.: +82 2 2629 8312
Fax: +82 2 2629 8310
[email protected]
India
Tel. : +44 (0) 1202 606030
Fax: +44 (0) 1202 606035
[email protected]
South East Asian &
Pacific Countries
Custom Sensors &
Technologies
2F, No. 39, Ji-Hu Road
Nei-Hu Dist.
Taipei 114, Taiwan
Tel.: +886 2 8751 6388 ext.131
Fax: +886 2 2657 8725
[email protected]
[email protected]
CST Sensors India Pvt Ltd
4th Floor, Trident Towers,
No. 23, 100 Ft- Ashoka Pillar Road,
2nd Block, Jayanagar,
Bangalore- 560011
Tel: +91 (80) 4113 2204 /05
Fax: +91 (80) 4113 2206
[email protected]
CAT/CR/DRT/EN
Distributed by :
© 2012 Crydom Inc., All Rights Reserved.
Specifications are subject to change without prior notice. Crydom and the Crydom logo are registered
trademarks of Crydom Inc.
09/2012
Rev.060713