200939H.pdf

DATA SHEET
SKY65336-11: 2.4 GHz Transmit/Receive Front-End Module
with Integrated LNA
Applications
Description
• 2.4 GHz ISM band radios
Skyworks SKY65336-11 is a high-efficiency Front-End Module
(FEM) for ZigBee and other 2.4 GHz ISM band applications. The
small
8 x 8 mm Multi-Chip Module (MCM) contains a 2400-2500 MHz
high-efficiency transmit path and a low-noise linear receive path.
• ZigBee® FEMs
• IEEE 802.15.4 applications
The transmit path consists of an harmonic filter and high
efficiency Power Amplifier (PA) capable of providing +20 dBm of
power at the antenna port. Also included is an internal balun to
allow use of differential input signals.
Features
• Transmit output power > +20 dBm
• Receive NF < 3 dB
The receive path contains a high isolation Transmit/Receive
(Tx/Rx) switch, Low Noise Amplifier (LNA), and balun for low noise
differential output.
• High efficiency PA
• Programmable transmit power levels
• Configurable transmit/receive paths
The device is mounted in a 28-pin, 8 x 8 mm MCM SurfaceMounted Technology (SMT) package, which allows for a highly
manufacturable low-cost solution.
• Internal switching and control circuits
• Internal RF match and bias circuits
• Single DC supply = 3.0 V
• Interfaces seamlessly with Ember EM250 and EM260 ZigBee
transceivers
A block diagram of the SKY65336-11 is shown in Figure 1. The
device package and pinout for the 28-pin MCM are shown in
Figure 2.
• All RF ports are internally DC blocked
• Small footprint, MCM (28-pin, 8 x 8 mm) SMT package (MSL3,
260 °C per JEDEC J-STD-020)
Figure 1. SKY65336-11 Block Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200939H • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 3, 2011
1
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 2. SKY65336-11 Pinout – 28-Pin MCM
(Top View)
Technical Description
Bottom Center Paddles
Transmit/Receive (Tx/Rx) Enable
The bottom center paddles must be electrically grounded for
proper RF performance. Customers should place adequate
thermal vias under the ground paddles for optimum thermal
performance. The Evaluation Board layout (see Figures 3 and 4)
can be used as a guide for RF ground and thermal layout.
Pin 27 (TX_EN) and pin 12 (RX_EN) are used to enable the
transmit and receive port, respectively.
Tx/Rx Switch
Pin 28 (T_R) is used to control the Tx/Rx switch.
Electrical and Mechanical Specifications
Tx/Rx Enable and Tx/Rx Switch Mode Control
The following control logic is used to configure the transmit or
receive mode of the SKY65336-11:
TX_EN
RX_EN
T_R
Mode
High
Low
High
Transmit mode
Low
High
Low
Receive mode
Signal pin assignments and functional pin descriptions are
described in Table 1. The absolute maximum ratings of the
SKY65336-11 are provided in Table 2. Recommended operating
conditions are noted in Table 3 and electrical specifications are
provided in Table 4.
Typical performance characteristics of the SKY65336-11 are
shown in Figures 3 through 12.
High Power and Low Power Modes
High power mode output is 20 dBm and low power mode output
is 10 dBm. Pin 26 (TX_HLB) sets the transmit path in high power
or low power mode according to the following logic:
TX_HLB
State
Low
High power mode
High
Low power mode
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
October 3, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939H
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Table 1. SKY65336-11 Signal Descriptions
Pin #
Name
Description
Pin #
Name
Description
1
BIAS1_PASS
Transmit port bias supply
15
GND
Ground
2
TX_N
Negative transmit input port
16
GND
Ground
3
TX_P
Positive transmit input port
17
GND
Ground
4
GND
Ground
18
ANT
Antenna input
5
GND
Ground
19
GND
Ground
6
BIAS2_PASS
Receive port bias supply
20
GND
Ground
7
RX_N
Negative receive output port
21
GND
Ground
8
RX_P
Positive receive output port
22
GND
Ground
9
GND
Ground
23
GND
Ground
10
GND
Ground
24
TX_VCC
Transmit DC supply, +3 V
11
RX_VCC
Receive DC supply, +3 V
25
GND
Ground
12
RX_EN
Receive enable
26
TX_HLB
Transmit power mode
13
GND
Ground
27
TX_EN
Transmit enable
14
GND
Ground
28
T_R
Transmit/receive switch
Note:
The bottom ground pad must be connected to RF ground.
Table 2. SKY65336-11 Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
2.1
4
V
BIAS1_PASS,
BIAS2_PASS, TX_EN,
RX_EN, TX_HLB, T_R
3.6
V
Bypass voltage
BIAS1_PASS, BIAS2_PASS
1.9
V
RF input power, antenna port
PIN_ANT
10
dBm
Supply voltage
RX_VCC, TX_VCC
Control Voltage
RF input power, transmit port
PIN_TX
+8
dBm
Case operating temperature
TC
–40
+85
°C
Storage temperature
TST
–55
+125
°C
Junction temperature
TJ
+150
°C
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200939H • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 3, 2011
3
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Table 3. SKY65336-11 Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
Maximum
Units
Supply voltage (TX_VCC, RX_VCC)
VCC
2.7
3.0
3.6
V
Tx/Rx bias supply voltage
BIAS1_PASS,
BIAS2_PASS
1.7
1.8
1.9
V
Tx/Rx enable voltage:
Low
High
TX_ENL, RX_ENL
TX_ENH, RX_ENH
1.62
0
1.80
0.1
VCC – 0.2
V
V
Tx/Rx control voltage:
Low
High
T_RL, TX_HLBL
T_RH, TX_HLBH
1.62
0
1.80
0.1
VCC – 0.2
V
V
Frequency range
f
2400
2500
MHz
Table 4. SKY65336-11 Electrical Specifications (Note 1)
(VCC = 3.0 V, TC = 25 °C, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Frequency range
f
Return loss
RL
All RF ports
PIN
CW, high or low power
mode
Min
Typical
2400
6
Max
Units
2500
MHz
10
dB
Transmitter Section
Input power range
+3
+5
dBm
PSAT_H
High power mode
+19.5
+20
dBm
PSAT_L
Low power mode
+8
+10
dBm
IOP_H
POUT = +20 dBm in high
power mode
145
160
mA
IOP_L
POUT = +10 dBm in low
power mode
70
80
mA
Harmonic levels (Note 2)
PN
CW, POUT = +20 dBm in
high power mode,
POUT = +10 dBm in low
power mode
–44
–39
dBm
Saturated gain
GH
CW, high power mode
17
GL
CW, low power mode
ILEAK
No RF input, VCC = 3.0 V,
RX_EN = 0 V,
TX_EN = 0 V
Small signal gain
G
CW
Noise Figure
NF
Input 1 dB compression
IP1dB
CW
Input IP3
IIP3
Two CW tones spaced
1 MHz apart
@ PIN = –9 dBm
Operating current
ICC
CW
Leakage current
ILEAK
No RF input, VCC = 3.0 V,
RX_EN = 0 V,
TX_EN = 0 V
Transmit saturated output power
Operating current
Leakage current
dB
7
0.5
dB
2.0
μA
Receiver Section (Frequency = 2445 MHz)
9.5
10.5
2.0
–1
dB
3.0
dBm
+3
dBm
8
15
mA
0.5
2.0
μA
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Note 2: Harmonic levels using the Zigbee modulated signal are +6 dBm lower than the values shown here.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
dB
–11
October 3, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939H
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Typical Performance Characteristics
(VCC = 3.0 V, TC = 25 °C, Unless Otherwise Noted)
Figure 3. Output Power vs Input Power Over Voltage @ 2450 MHz
Figure 4. Output Power vs Input Power Over Temperature
@ 2450 MHz
Figure 5. Saturated Output Power vs Frequency Over Voltage
Figure 6. Saturated Output Power vs Frequency Over Temperature
Figure 7. Operating Current vs Output Power Over Voltage
@ 2450 MHz
Figure 8. Operating Current vs Output Power Over Temperature
@ 2450 MHz
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200939H • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 3, 2011
5
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 9. Second Harmonics vs Frequency Over Voltage
(High Power Mode)
Figure 10. Third Harmonics vs Frequency Over Voltage
(High Power Mode)
Figure 11. Fourth Harmonics vs Frequency Over Voltage
(High Power Mode)
Figure 12. Fifth Harmonics vs Frequency Over Voltage
(High Power Mode)
Evaluation Board Description
The SKY65336-11 Evaluation Board is used to test the
performance of the SKY65336-11 FEM. The Evaluation Board
schematic diagram is shown in Figure 13. An assembly drawing
for the Evaluation Board is shown in Figure 14.
Package Dimensions
The PCB layout footprint for the SKY65336-11 is shown in
Figure 15. Package dimensions for the 28-pin MCM are shown in
Figure 16, and tape and reel dimensions are provided in
Figure 17.
shipping container label regarding exposure to moisture after the
container seal is broken must be followed. Otherwise, problems
related to moisture absorption may occur when the part is
subjected to high temperature during solder assembly.
The SKY65336-11 is rated to Moisture Sensitivity Level 3 (MSL3)
at 260 °C. It can be used for lead or lead-free soldering. For
additional information, refer to Skyworks Application Note, PCB
Design and SMT Assembly/Rework Guidelines for MCM-L
Packages, document number 101752.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Package and Handling Information
Since the device package is sensitive to moisture absorption, it is
baked and vacuum packed before shipping. Instructions on the
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
October 3, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939H
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 13. SKY65336-11 Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200939H • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 3, 2011
7
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 14. SKY65336-11 Evaluation Board Assembly Drawing
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
October 3, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939H
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 15. SKY65336-11 PCB Layout Footprint
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200939H • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 3, 2011
9
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 16. SKY65336-11 28-Pin MCM Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
October 3, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939H
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 17. SKY65336-11 28-Pin MCM Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200939H • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 3, 2011
11
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Ordering Information
Model Name
SKY65336-11 Tx/Rx FEM w/LNA
Manufacturing Part Number
SKY65336-11
Evaluation Board Part Number
TW17-D475-001
Copyright © 2008, 2009, 2011 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,
are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
12
October 3, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939H