201181F.pdf

DATA SHEET
SKY65344-21: 2.4 GHz Transmit/Receive Front-End Module
with Integrated Low-Noise Amplifier
Applications
Description
• 2.4 GHz ISM band radios
Skyworks SKY65344-21 is a high-efficiency Front-End Module
(FEM) for ZigBee and other 2.4 GHz ISM band applications. The
small, 6 x 6 mm Multi-Chip Module (MCM) contains a 2400 to
2500 MHz high-efficiency transmit path and a low-loss
bidirectional path. The bidirectional path can be used to directly
connect the antenna port to a directional RF port.
• ZigBee® FEMs
• IEEE 802.15.4 applications
Features
The transmit path consists of an harmonic filter and high
efficiency Power Amplifier (PA) capable of providing +20 dBm of
power at the antenna port. Also included is an internal balun to
allow use of differential input signals.
• Transmit output power > +20 dBm
• Receive path NF < 2.2 dB
• High efficiency PA
The receive path contains a high isolation transmit/receive (T/R)
switch, Low-Noise Amplifier (LNA), and balun for low-noise
differential output.
• Programmable transmit power levels
• Configurable transmit/bidirectional paths
• Internal switching and control circuits
The device is mounted in a 20-pin, 6 x 6 mm MCM SurfaceMounted Technology (SMT) package, which allows for a highly
manufacturable low-cost solution.
• Internal RF match and bias circuits
• Single DC supply = 3.3 V
• Interfaces seamlessly with Ember EM250, EM260, and EM35x
ZigBee transceivers
• All RF ports are internally DC blocked
A block diagram of the SKY65344-21 is shown in Figure 1. The
device package and pinout for the 20-pin MCM are shown in
Figure 2.
• Small footprint, MCM (20-pin, 6 x 6 mm) SMT package (MSL3,
260 °C per JEDEC J-STD-020)
Figure 1. SKY65344-21 Block Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201181F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 2, 2011
1
DATA SHEET • SKY65344-21 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 2. SKY65344-21 Pinout – 20-Pin MCM
(Top View)
Technical Description
Shut Down and T/R Switch Mode Control
Pin 8 (SDN) is used to enable the device while pin 20 (T_R)
enables transmit or receive mode. The following control logic is
used to configure the transmit, receive, or shut down mode of the
SKY65344-21:
SDN
(Pin 8)
T_R
(Pin 20)
Mode
High
High
Transmit mode
High
Low
Receive mode
Low
Low
Shut Down mode
thermal vias under the ground paddles for optimum thermal
performance. The Evaluation Board layout can be used as a guide
for RF ground and thermal layout.
Electrical and Mechanical Specifications
Signal pin assignments and functional pin descriptions are
described in Table 1. The absolute maximum ratings of the
SKY65344-21 are provided in Table 2. The recommended
operating conditions are specified in Table 3 and electrical
specifications are provided in Table 4.
Typical performance characteristics of the SKY65344-21 are
shown in Figures 3, 4, and 5.
Bottom Center Paddle
The bottom center paddles must be electrically grounded for
proper RF performance. Customers should place adequate
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
May 2, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201181F
DATA SHEET • SKY65344-21 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Table 1. SKY65344-21 Signal Descriptions
Pin #
Description
Pin #
Name
Description
1
BIAS1
Transmit port bypass voltage
11
GND
Ground
2
TX_P
Positive transmit input port
12
GND
Ground
3
TX_N
Negative transmit input port
13
ANT
Antenna port
4
BIAS2
Receive port bypass voltage
14
GND
Ground
5
RX_P
Positive receive output port
15
GND
Ground
6
RX_N
Negative receive output port
16
GND
Ground
7
GND
Ground
17
TX_VCC
Transmit DC supply, +3.3 V
8
SDN
Shut down enable
18
GND
Ground
9
RX_VCC
Receive DC supply, +3.3 V
19
N/C
No connection
GND
Ground
20
T_R
Transmit/receive control
10
Note:
Name
The bottom ground pad must be connected to RF ground.
Table 2. SKY65344-21 Absolute Maximum Ratings (Note 1)
Parameter
Supply voltage
Symbol
Minimum
Maximum
Units
1.8
4
V
RX_VCC, TX_VCC
Control voltage
SDN, T_R
Bypass voltage
BIAS1, BIAS2
RF input power, antenna port
PIN_ANT
3.6
V
4
V
+10
dBm
RF input power, transmit port
PIN_TX
+8
dBm
Case operating temperature
TC
–40
+85
°C
Storage temperature
TST
–55
+125
°C
Junction temperature
TJ
+150
°C
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY65344-21 Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
2400
Maximum
Units
Frequency range
f
2500
MHz
Supply voltage (TX_VCC, RX_VCC)
VCC
2.7
3.3
3.6
V
Shut down and T/R control voltage:
Low
High
T_RL, SDNL
T_RH, SDNH
1.62
0
1.80
0.1
3.60
V
V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201181F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 2, 2011
3
DATA SHEET • SKY65344-21 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Table 4. SKY65344-21 Electrical Specifications (Note 1)
(Vcc = 3.3 V, TC = 25 °C, PIN = +3 dBm, Unless Otherwise Noted)
Parameter
Symbol
Frequency range
f
Return loss (Note 2)
RL
Transmit differential port (TX_P, TX_N)
impedance (Note 2)
Receive differential port (RX_P, RX_N)
impedance (Note 2)
Test Condition
Min
Typical
2400
All RF ports
Max
Units
2500
MHz
10
dB
ZDTX
29 + j75
Ω
ZDRX
68 + j38
Ω
Input power range
PIN
+3
dBm
Maximum output power (Note 2)
PSAT
+21.5
dBm
Transmit output power
POUT
Operating current
IOP_H
Transmitter Section
nd
+19.5
+20.0
dBm
105
130
mA
2 harmonic
Pn2
IEEE 802.15.4 OQPSK
modulated
–48
–43
dBm
3rd harmonic
Pn3
IEEE 802.15.4 OQPSK
modulated
–49
–43
dBm
Small signal gain (Note 2)
GH
PIN = –10 dBm
20
dB
Spur (Note 2)
VSWR up to 10:1 (all
phase angles)
No parasitic oscillation > –44 dBm
–
Ruggedness (Note 2)
VSWR up to 10:1 (all
phase angles)
No module damage or permanent degradation
–
Receive Section
Small signal gain
G
CW
7
10
Noise Figure
NF
1 dB Input Compression Point (Note 2)
IP1dB
CW
–11
dBm
3rd Order Input Intercept Point (Note 2)
IIP3
Two CW tones, spaced
1 MHz apart
@ PIN = –9 dBm
–1
dBm
Operating current
ICC
CW
7
10
mA
Leakage current
ILEAK
No RF input, VCC = 3.3 V,
SDN = 0 V, T_R = 0 V
4
10
μA
2.2
dB
3.0
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Note 2: Parameter is characterized under the conditions in this Table but is not production tested.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
May 2, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201181F
dB
DATA SHEET • SKY65344-21 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Typical Performance Characteristics
(VCC = 3.3 V, TC = 25 °C, PIN = +3 dBm, Unless Otherwise Noted)
Figure 3. Output Power vs Input Power
@ 2445 MHz
Figure 4. Output Power vs Input Power Over Temperature
@ 2445 MHz
Figure 5. Output Power vs Supply Voltage
@ 2445 MHz
Evaluation Board Description
Package and Handling Information
The SKY65344-21 standalone Evaluation Board is used to test the
performance of the SKY65344-21 FEM. The Evaluation Board
schematic diagram is shown in Figure 6. An assembly drawing for
the Evaluation Board is shown in Figure 7.
Since the device package is sensitive to moisture absorption, it is
baked and vacuum packed before shipping. Instructions on the
shipping container label regarding exposure to moisture after the
container seal is broken must be followed. Otherwise, problems
related to moisture absorption may occur when the part is
subjected to high temperature during solder assembly.
A reference design Evaluation Board is also available to test the
SKY65344-21 with an Ember EM35x series transceiver (see
Ordering Information on the last page of this Data Sheet).
Package Dimensions
The phone board layout footprint for the SKY65344-21 is shown in
Figure 8. Package dimensions for the 20-pin MCM are shown in
Figure 9, and tape and reel dimensions are provided in Figure 10.
The SKY65344-21 is rated to Moisture Sensitivity Level 3 (MSL3)
at 260 °C. It can be used for lead or lead-free soldering. For
additional information, refer to Skyworks Application Note, PCB
Design and SMT Assembly/Rework Guidelines for MCM-L
Packages, document number 101752.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201181F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 2, 2011
5
DATA SHEET • SKY65344-21 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 6. SKY65344-21 Standalone Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
May 2, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201181F
DATA SHEET • SKY65344-21 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 7. SKY65344-21 Standalone Evaluation Board Assembly Drawing
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201181F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 2, 2011
7
DATA SHEET • SKY65344-21 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 8. SKY65344-21 Phone Board Layout Footprint
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
May 2, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201181F
DATA SHEET • SKY65344-21 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 9. SKY65344-21 20-Pin MCM Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201181F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 2, 2011
9
DATA SHEET • SKY65344-21 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Figure 10. SKY65344-21 20-Pin MCM Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
May 2, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201181F
DATA SHEET • SKY65344-21 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Ordering Information
Model Name
SKY65344-21 T/R Front-End Module with LNA
Manufacturing Part Number
SKY65344-21
Evaluation Board Part Number
TW17-D755 (Standalone Board)
EM35X_SKY65344 (EM357 and SKY65344-21
Zigbee Reference Design)
Copyright © 2009, 2010, 2011 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,
are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201181F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 2, 2011
11