SKY13582_676LF_203357E.pdf

DATA SHEET
SKY13582-676LF: 0.4 to 3.8 GHz SP3T Switch
Applications
 Cellular systems
 3G/4G LTE systems
 Pre- and post-PA switching
RF1
Features
RF2
 Broadband frequency range: 0.4 to 3.8 GHz
RF3
 Very low insertion loss
RFC
 High isolation: 25 dB at 2.7 GHz
 Integrated GPIO interface
Logic and Supply
 No DC blocking capacitors required
203357-001
 Lead (Pb)-free and RoHS-compliant
VDD
 Small QFN (9-pin, 1.1  1.1  0.5 mm) package
(MSL1, 260 C per JEDEC J-STD-020)
VC1
VC2
Figure 1. SKY13582-676LF Block Diagram
Description
Skyworks Green™ products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of Green™, document number
SQ04-0074.
1
VC1
8
VC2
7
VDD
2
RF2
9
GND
6
GND
3
RF1
4
RFC
5
RF3
The SKY13582-676LF is a single-pole, triple-throw (SP3T) switch.
No external DC blocking capacitors are required on the RF paths
as long as there is no DC voltage on the RF line. The switch can
operate over the temperature range of −40 C to +85 C.
Switching is controlled by two CMOS/TTL compatible control
voltage inputs (VC1 and VC2). Depending on the logic voltage level
applied to the control pin, the RFC pin is connected to one of three
switched RF outputs (RF1, RF2, or RF3) by using a low insertion
loss path, while the path between the RFC pin and the other RF
pins is in isolation.
The SKY13582-676LF is provided in a small 9-pin,
1.1  1.1  0.5 mm QFN package.
A functional block diagram is shown in Figure 1. The pin
configuration and package are shown in Figure 2. Signal pin
assignments and functional descriptions are provided in Table 1.
203357-002
Figure 2. SKY13582-676LF Pinout
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203357E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 28, 2016
1
DATA SHEET • SKY13582-676LF: 0.4 TO 3.8 GHz SP3T SWITCH
Table 1. SKY13582-676LF Pin Descriptions1
Pin
Name
Description
Pin
Name
Description
1
VC1
Control voltage 1
6
GND
Ground
2
RF2
RF input/output port 2
7
VDD
Supply voltage
3
RF1
RF input/output port 1
8
VC2
Control voltage 2
4
RFC
RF common port
9
GND
Ground
5
RF3
RF input/output port 3
1 Exposed pads must be grounded.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY13582-676LF are
provided in Table 2. Electrical specifications are provided in
Table 3. Table 4 is the logic truth table. Tables 5 and 6 show the
isolation matrix specifications.
Table 2. SKY13582-676LF Absolute Maximum Ratings1
Parameter
Symbol
Condition
Minimum
Maximum
Units
5.5
V
Supply voltage
VDD
T = 25 C
2.35 Control voltages
VC1, VC2
T = 25 C
0
RF input power
RFIN
CW, T = 25 C; 50 
Operating case temperature
TCASEMAX
Storage temperature
TSTG
3.1 V
+35
dBm
40
+85
C
55
+150
C
1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set
at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
March 28, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203357E
DATA SHEET • SKY13582-676LF: 0.4 TO 3.8 GHz SP3T SWITCH
Table 3. SKY13582-676LF Electrical Specifications1 (1 of 2)
(VDD = 2.85 v, TOP = +25 °C, Characteristic Impedance [Zo] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
0.35
0.40
0.50
0.6
0.5
0.6
0.65
0.8
dB
dB
dB
dB
Small Signal
Insertion loss (RFC to RF1-RF3) 2 IL
400 to 960 MHz
960 to 2170 MHz
2170 to 2700 MHz
2700 to 3800 MHz
Isolation (RFC to RF1-RF3) ISO
400 to 960 MHz
960 to 2170 MHz
2170 to 2700 MHz
2700 to 3800 MHz
32
23
20
18
36
27
25
23
dB
dB
dB
dB
Isolation (TRXx to any Off TRXx ports
[adjacent]) ISO
400 to 960 MHz
960 to 2170 MHz
2170 to 2700 MHz
2700 to 3800 MHz
32
23
20
15
35
25
23
18
dB
dB
dB
dB
Isolation (TRXx to any Off TRXx ports
[non-adjacent]) ISO
400 to 960 MHz
960 to 2170 MHz
2170 to 2700 MHz
2700 to 3800 MHz
36
29
25
20
39
32
27
22
dB
dB
dB
dB
Return loss (RFC to RF1-RF3) RL 400 to 2700 MHz
2700 to 3800 MHz
14
10
20
15
dB
dB
Up to 3800 MHz
+34
+35
dBm
Large Signal
0.1dB compression point
LTE/WCDMA harmonic, RF1, RF2 or RF3
to ANT, low band
LTE/WCDMA harmonic, RF1, RF2 or RF3
to ANT, mid band
LTE/WCDMA harmonic, RF1, RF2 or RF3
to ANT, high band
Second order intermodulation product Third order intermodulation product Triple beat ratio
Triple beat ratio
P0.1dB
2fO, 3fO
2fo, 3fo
2fo, 3fo
fO = 824 to 960 MHz
PIN = +26 dBm, VSWR 1:1
−72
–66
dBm
fO = 824 to 960 MHz
PIN = +26 dBm, VSWR 5:1
−65
–60
dBm
fO = 1710 to 1910 MHz
PIN = +26 dBm, VSWR 1:1
−72
–60
dBm
fO = 1710 to 1910 MHz
PIN = +26 dBm, VSWR 5:1
−65
–59
dBm
fO = 2170 to 2690 MHz
PIN = +26 dBm, VSWR 1:1
−70
–62
dBm
fO = 2170 to 2690 MHz
PIN = +26 dBm, VSWR 5:1
−65
–59
dBm
fO = 3400 to 3800 MHz
PIN = + 26 dBm, VSWR 1:1
−65
–60
dBm
fO = 3400 to 3800 MHz
PIN = + 26 dBm, VSWR 5:1
−60
–55
dBm
IIP2 Bands 1, 5, 7
Ftx: +24 dBm, Fbl:-15 dBm
+103
+110
dBm IIP3 Bands 1, 5, 7
Ftx: +24 dBm, Fbl:-15 dBm
+61
+66
dBm TBR
650 to 900 MHz,
TX1 = TX2 = +21.5 dBm, Block= -30 dBm
+51
+85
dBc
1710 to 2155 MHz,
TX1 = TX2 = +21.5 dBm, Block= -30 dBm
+51
+85
dBc
TBR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203357E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 28, 2016
3
DATA SHEET • SKY13582-676LF: 0.4 TO 3.8 GHz SP3T SWITCH
Table 3. SKY13582-676LF Electrical Specifications1 (2 of 2)
(VDD = 2.85 v, TOP = +25 °C, Characteristic Impedance [Zo] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
DC Operating
Supply voltage
VDD
T = 25 C 2.45
2.85
4.8
V
Control voltage high
VC1
T = 25 C 1.35
1.8
3
V
Control voltage low
VC1
T = 25 C 0
0.4
V
Supply current
IDD
T = 25 C 100
A
Control current
ICTL
T = 25 C 1
A
Switching speed
tSW
From one active state to another active state. 5
s
Startup time
tON
From VDD off to VDD on 20
s
40
2
1 Performance is guaranteed only under the conditions listed in this table.
2 Insertion loss is measured with a series inductor added to the RFC line.
Table 4. SKY13582-676LF Logic Truth Table
Path
VDD
VC1
VC2
RFC to RF1
H
H
L
RFC to RF2
H
H
H
RFC to RF3
H
L
H
Isolation
H
L
L
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
March 28, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203357E
DATA SHEET • SKY13582-676LF: 0.4 TO 3.8 GHz SP3T SWITCH
Table 5. SKY13582-676LF Isolation Matrix ANT to OFF Arms
Antenna to OFF Arm
Frequency (MHz)
ANT
RF1
RF2
RF3
960
–51
–36
ANT
2170
–40
–29
ANT
2690
–37
–27
ANT
3800
–31
–23
ANT
960
–38
–34
ANT
2170
–30
–26
ANT
2690
–27
–24
ANT
3800
–23
–21
ANT
960
–34
–40
ANT
2170
–27
–33
ANT
2690
–25
–31
ANT
3800
–22
–27
Table 6. SKY13582-676LF Isolation Matrix ON Arms to OFF Arms
Throw
Frequency (MHz)
RF1
RF2
RF3
RF1
960
–35
–48
RF1
2170
–28
–38
RF1
2690
–26
–35
RF1
3800
–23
–30
RF2
960
–37
–53
RF2
2170
–29
–41
RF2
2690
–26
–38
RF2
3800
–22
–32
RF3
960
–52
–49
RF3
2170
–39
–40
RF3
2690
–36
–38
RF3
3800
–29
–33
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203357E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 28, 2016
5
DATA SHEET • SKY13582-676LF: 0.4 TO 3.8 GHz SP3T SWITCH
Evaluation Board Description
Package and Handling Information
The SKY13582-676LF Evaluation Board is used to test the
performance of the SKY13582-676LF SP3T switch. An Evaluation
Board schematic diagram is provided in Figure 3. An assembly
drawing of the Evaluation Board is shown in Figure 4.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
The SKY13582-676LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 C. It can be used for lead or lead-free soldering.
For additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
Package Dimensions
The PCB layout footprint for the SKY13582-676LF is provided in
Figure 5. Typical part markings are shown in Figure 6. Package
dimensions are shown in Figure 7, and tape and reel dimensions
are provided in Figure 8.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
DC
Control
C2
DNI
1
VC1
DC
Control
C3
DNI
C1
DNI
RFC2
RFC1
DC
Supply
7
VDD
8
VC2
2
RF2
9
GND
6
GND
3
RF1
4
RFC
5
RF3
GND
RFC3
203357-003
L1
1.0 nH
RFC4
Figure 3. SKY13582-676LF Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
March 28, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203357E
DATA SHEET • SKY13582-676LF: 0.4 TO 3.8 GHz SP3T SWITCH
DCH1
C2
C1
C3
U1
L1
RFC2
RF
C3
C1
RFC4
RF
Y2026
Figure 4. SKY13582-676LF Evaluation Board Assembly Diagram
DCH1
C2
C1
C3
U1
L1
RFC2
RF
C3
RFC4
C1
RF
203357-004
Figure 5. SKY13582-676LF PCB Layout Footprint
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203357E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 28, 2016
7
DATA SHEET • SKY13582-676LF: 0.4 TO 3.8 GHz SP3T SWITCH
Pin 1
Indicator
Skyworks
Part Number:
0 = Zero First Character
X = Q/Y Code
Lot Code
203357-006
Figure 6. Typical Part Marking
(Top View)
Seating
Plane
C
Pin 8
6X 0.400
1.10
Pin 1
Indicator
Pin 1 Indicator
Pin1
See Detail B
−0.004 ~ 0.046
A
B
0.400 Pitch
1.10
6X 0.400
0.05 C
2X
See Detail A
2X
0.05 C
0.110 Ref
0.45 +0.045
–0.05
0.05 C
Top View
0.05 C
8X 0.050
Exposed Pad
Bottom View
3
9X
Side View
0.2 ± 0.05
5X R0.030
0.2 ± 0.05
0.2 ± 0.05
Detail A
Pin 1 Indicator
0.06 X 0.06
0.10 M C A B
5
5
0.2 ± 0.05
0.10 M C A B
Scale: 100X
3X This Rotation
2X Rotated 180 º
1X Rotated 90 ºCW
1X Rotated 90 ºCCW
Detail B
Scale: 100X
1X This Rotation
Notes:
1. Dimensions and tolerances per ASME Y14.5-1994.
2. All dimensions are in millimeters unless otherwise specified.
3. Coplanarity applies to the terminals and all other bottom surface metallization.
4. Plating requirement per source control drawing (SCD) 2504.
5. Dimension applies to metallized terminal. If the terminal has a radius on its end, the width dimension should
not be measured in that radius area.
203357-007
Figure 7. SKY13582-676LF Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
March 28, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203357E
1.75 ± 0.10
4.0 ± 0.10
Pin 1
Ø1.50
0.25 ± 0.05 (T)
+0.1
2.0 ± 0.05
B
3.5 ± 0.05
DATA SHEET • SKY13582-676LF: 0.4 TO 3.8 GHz SP3T SWITCH
1.29 ± 0.05 (Bo)
8.0 + 0.30
–0.10
R0.10 Max
A
A
B
0.64 ± 0.05 (Ko)
R0.3 Typ
4.0 ± 0.10
Ø0.50
Section B
Min
User Feed
Direction
Notes:
1. Carrier tape must meet all requirements of Skyworks GP01-D233 procurement spec for tape and reel shipping.
2. Carrier tape shall be black conductive polycarbonate or polystyrene.
3. Cover tape shall be transparent conductive material.
4. ESD-surface resistivity shall be ≤ 1 × 1010 Ω/square per EIA, JEDEC TNR specification.
5. 10-sprocket hole pitch cumulative tolerance: ±0.20 mm.
6. Ao and Bo measured on plane 0.30 mm above the bottom of the pocket.
7. All dimensions are in millimeters.
1.29 ± 0.05 (Ao)
Section A
0.01–0.06
203357-008
Figure 8. SKY13582-676LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203357E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 28, 2016
9
DATA SHEET • SKY13582-676LF: 0.4 TO 3.8 GHz SP3T SWITCH
Ordering Information
Model Name
SKY13582-676LF: 0.4 to 3.8 GHz SP3T Switch
Manufacturing Part Number
SKY13582-676LF
Evaluation Board Part Number
EN37-D666-001
Copyright © 2014-2016 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
March 28, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203357E