Model MM9xMS Model MM9xMS-14 Double Balanced Mixer Multi-Octave Band Electrical Specifications RF 1.5 to 19.0 GHz (1) : Conditions Parameter SSB Conversion loss:(2) (3) RF(GHz) 2.0-18.0 2.0-18.0 1.5-19.0 Isolation LO to RF: LO to IF: RF to IF: IF to RF: Input 1-dB Compression Point: Input Third Order Intercept Point: LO Power: (4) LO(GHz) 2.0-18.0 2.0-18.0 1.5-19.0 IF(MHz) 2.0-5.0 0.5-6.5 0.5-6.5 1.5-4.0 4.0-19.0 1.5-19.0 1.5-19.0 1.5-19.0 1.5-19.0 0.5-6.5 0.5-6.5 1.5-19.0 1.5-19.0 0.5-.6.5 1.5-19.0 1.5-19.0 0.5-6.5 Specifications Min Typical 6.8 dB 7.8 dB 8.0 dB 17 dB 20 dB 20 dB 23 dB 31 dB 25 dB 27 dB 20 dB +5 dBm +8 dBm +12 dBm +15 dBm +14 dBm +17 dBm +21 dBm +24 dBm +10 dBm +13 dBm +17 dBm +21 dBm Max 9.0 dB 11.0 dB 11.5 dB LO Power 4 = +10 dBm 6 = +13 dBm 7 = +17 dBm 8 = +21 dBm Notes: 1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system at +25˚C with the nominal LO power. Specifications indicated as typical are not guaranteed. 2. Noise figure is typically within ±0.5 dB of conversion loss for IF frequencies greater than 10 MHz. 3. Conversion loss typically degrades less than 0.5 dB at +100˚C and improves less than 0.5 dB at -55˚C. 4. Usable LO drives are up to 2 dB below and 3 dB above nominal. MM9xMS Outline: MS3C MM9xMS-14 Outline: MS3D Typical Performance at 25˚C MICROWAVE INC. M SP All dimensions are in inches and [mm]. ECTRU A Spectrum Control Business SPECTRUM MICROWAVE • 2144 Franklin Drive N.E. • Palm Bay, Florida 32905 • Phone: (888) 553-7531 • Fax: (888) 553-7532 www.specwave.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 626