PS_PS-DA0403-01.pdf

DC-AC INVERTER UNIT
PS-DA0403-01(S) (30 W QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for quad lamps.
APPLICABLE LCD:
6.4 to 15 inches quad lamp type
Lamp Voltage 714 Vrms
Lamp Current 4 x 10,5 mArms
Lamp Start Up Voltage 1.700 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open Lamp Detection
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
0°C ~ +50°C
-20°C ~ +85°C
95 %RH max
220 x 50 x 10 mm
Pin 1
Unit : mm
Weight :67 (g) typ.
Pin 1
Pin 1
Pin 1
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 + CN3
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
Vin
CN 1-2
GND
CN 1-3
GND
CN 1-4
Vrm t
CN 1-5
GND
CN 1-6
CN 1-7
Vbr
Qty.
1
1
2
Material
UL94V-0 (FR-4 or CEM-3)
S7B-PH-SM3-1-TB
SM04(4.0)B-BHS-1-TB
Output side CN2:
Pin No.
Symbols
Ratings
Vhigh
714
Vrm
s (10.5 m Arm s )
CN 2-1+2
N.C.
CN 2-3
Vlow
(GND)
CN 2-4
Ratings
10.8 ~ 13.2 Vdc
10.8 ~ 13.2 Vdc
0 ~ 0.4 = OFF / 4.5 ~ Vin = ON
0 ~ 3.3 Vdc
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Note
t=1m m
JST or equal
JST or equal
Output side CN3:
Pin No.
Symbols
Ratings
Vhigh
714 Vrm s (10.5 m Arm s )
CN 3-1+2
N.C.
CN 3-3
Vlow
(GND)
CN 3-4
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.6.3, 07th September 2010
DC-AC INVERTER UNIT
PS-DA0403-01(S) (30 W QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Ts d
No load Shutdown
Note 1 :
Conditions
Vrmt
Vin (V)
Tu (°C)
(V)
12±1.2 5±0.25 0 ~ +50
12±0.6 5±0.25 0 ~ +50
12±1.2 5±0.25 0 ~ +50
12±1.2 5±0.25 0 ~ +50
11.4
5±0.25 0 ~ +50
12±1.2
Specification
5±0.25 0 ~ +50
Unit
Note
Min.
Typ.
Max.
10.0
2.5
40
1.600
10.5
3.0
2.1
52
1.700
11.0
3.5
2.3
60
2.000
m Arm s
m Arm s
Adc
kHz
Vrm s
1.0
-
-
s ec
V br = 0 V dc
V br = 3.3 V dc
wit hout load
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
F
SW4
SW 1
Operation of unit
a
Operation
b
Non operation
CN2-2
CN1-3
CN1-4
a
V
V
~
CN2-1
CN1-1
CN1-2
V
Vrmt
0 / 5 Vdc
Vopen
SW3
Iin
A
Vin
12 V
1000:1
PROBE
F
b
RL2
T1
CN2-4
SW1
CN1-5
RL1
A
~
CL2
Iout
2
A
~
CL2
Iout
2
CL1
A
~
Iout
1
SW5
SW3
CN3-1
SW4
CN1-6
CN3-2
RL2
CN1-7
Vbr
0 ~ 3.3 Vdc
CN3-4
RL1
CL1
A
~
Iout
1
SW5
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.6.3, 07th September 2010