VS-HFA280NJ60CPbF Datasheet

VS-HFA280NJ60CPbF
www.vishay.com
Vishay Semiconductors
HEXFRED®
Ultrafast Soft Recovery Diode, 280 A
FEATURES
Lug
terminal
anode 1
Lug
terminal
anode 2
• Very low Qrr and trr
• UL approved file E222165
• Designed and qualified for industrial level
• Material categorization:
For definitions of compliance please see
www.vishay.com/doc?99912
Base common
cathode
TO-244
BENEFITS
• Reduced RFI and EMI
• Reduced snubbing
DESCRIPTION
PRODUCT SUMMARY
IF(AV)
280 A
VR
600 V
IF(DC) at TC
149 A at 100 °C
Package
TO-244 (TO-244AB)
Circuit
Two diodes common cathode
HEXFRED® diodes are optimized to reduce losses and
EMI/RFI in high frequency power conditioning systems. An
extensive characterization of the recovery behavior for
different values of current, temperature and dIF/dt simplifies
the calculations of losses in the operating conditions. The
softness of the recovery eliminates the need for a snubber in
most applications. These devices are ideally suited for
power converters, motors drives and other applications
where switching losses are significant portion of the total
losses.
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
Cathode to anode voltage
VR
Continuous forward current
IF
Single pulse forward current
Non-repetitive avalanche energy
Maximum power dissipation
Operating junction and storage
temperature range
TEST CONDITIONS
MAX.
UNITS
600
V
TC = 25 °C
292
TC = 100 °C
149
IFSM
Limited by junction temperature
600
EAS
L = 100 μH, duty cycle limited by maximum TJ
2.2
TC = 25 °C
657
TC = 100 °C
263
PD
TJ, TStg
A
mJ
W
-55 to +150
°C
ELECTRICAL SPECIFICATIONS (TJ = 25 °C unless otherwise specified)
PARAMETER
SYMBOL
TEST CONDITIONS
Cathode to anode
breakdown voltage
VBR
IR = 100 μA
Maximum forward voltage
VFM
IF = 210 A
IF = 105 A
See fig. 1
IF = 105 A, TJ = 125 °C
Maximum reverse 
leakage current
IRM
TJ = 125 °C, VR = 600 V
See fig. 2
Junction capacitance
CT
VR = 200 V
See fig. 3
Series inductance
LS
From top of terminal hole to mounting plane
MIN.
TYP.
MAX.
600
-
-
UNITS
-
1.33
1.8
-
1.53
2.1
-
1.22
1.64
-
2.4
8
-
280
400
pF
-
5.0
-
nH
V
mA
Revision: 26-Mar-14
Document Number: 94067
1
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
VS-HFA280NJ60CPbF
www.vishay.com
Vishay Semiconductors
DYNAMIC RECOVERY CHARACTERISTICS (TJ = 25 °C unless otherwise specified)
PARAMETER
SYMBOL
Reverse recovery time
See fig. 5
trr
Peak recovery current
See fig. 6
TYP.
MAX.
-
39
-
TJ = 25 °C
-
92
140
-
180
270
-
9.3
17
-
16
30
-
490
1200
TJ = 125 °C
-
1400
4000
TJ = 25 °C
-
290
-
TJ = 125 °C
-
200
-
SYMBOL
MIN.
TYP.
MAX.
UNITS
TJ, TStg
-55
-
150
°C
-
-
0.19
-
-
0.095
-
0.10
-
-
68
-
g
oz.
TJ = 25 °C
dI(rec)M/dt
UNITS
TJ = 125 °C
TJ = 125 °C
Qrr
Peak rate of recovery current
See fig. 8
MIN.
TJ = 25 °C
IRRM
Reverse recovery charge
See fig. 7
TEST CONDITIONS
IF = 1.0 A, dIF/dt = 200 A/μs, VR = 30 V
IF = 105 A
dIF/dt = 200 A/μs
VR = 200 V
ns
A
nC
A/μs
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER
Maximum junction and storage temperature range
per leg
Thermal resistance, junction to case
per module
Typical thermal resistance, case to heatsink
RthJC
RthCS
Weight
-
2.4
-
30 (3.4)
-
40 (4.6)
12 (1.4)
-
18 (2.1)
30 (3.4)
-
40 (4.6)
Vertical pull
-
-
80
2" lever pull
-
-
35
Mounting torque (1)
center hole
Terminal torque
°C/W
K/W
N m
(lbf in)
lbf in
10 000
1000
TJ = 150 °C
IR - Reverse Current (µA)
IF - Instantaneous Forward Current (A)
Note
(1) Mounting surface must be smooth, flat, free of burrs or other protrusions. Apply a thin even film or thermal grease to mounting surface.
Gradually tighten each mounting bolt in 5 to 10 lbf in steps until desired or maximum torque limits are reached.
100
TJ = 150 °C
TJ = 125 °C
TJ = 25 °C
10
1
0.2
0.7
1.2
1.7
2.2
2.7
3.2
TJ = 125 °C
1000
100
10
1
100
TJ = 25 °C
200
300
400
500
600
VFM - Forward Voltage Drop (V)
VR - Reverse Voltage (V)
Fig. 1 - Maximum Forward Voltage Drop vs.
Instantaneous Forward Current (Per Leg)
Fig. 2 - Typical Reverse Current vs. Reverse Voltage
(Per Leg)
Revision: 26-Mar-14
Document Number: 94067
2
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
VS-HFA280NJ60CPbF
www.vishay.com
Vishay Semiconductors
CT - Junction Capacitance (pF)
10 000
70
TJ = 125 °C
TJ = 25 °C
60
1000
IRRM (A)
50
TJ = 25 °C
IF = 200 A
IF = 140 A
IF = 50 A
40
30
20
10
100
1
10
100
0
100
1000
1000
VR - Reverse Voltage (V)
dIF/dt (A/µs)
Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage (Per Leg)
Fig. 6 - Typical Recovery Current vs. dIF/dt (Per Leg)
160
5000
TJ = 125 °C
TJ = 25 °C
4000
120
100
Qrr (nC)
Maximum Allowable
Case Temperature (°C)
140
DC
80
60
D = 0.50
IF = 200 A
IF = 140 A
IF = 50 A
3000
2000
40
1000
20
0
0
50
100
150
200
250
300
0
100
350
1000
IF(AV) - DC Forward Current (A)
dIF/dt (A/µs)
Fig. 4 - Maximum Allowable Case Temperature vs. DC Forward
Current (Per Leg)
Fig. 7 - Typical Stored Charge vs. dIF/dt (Per Leg)
10 000
300
IF = 200 A
IF = 140 A
IF = 50 A
trr (ns)
200
150
100
dI(rec)M/dt (A/µs)
250
TJ = 125 °C
TJ = 25 °C
200 A
140 A
50 A
1000
50
TJ = 125 °C
TJ = 25 °C
0
100
1000
100
100
1000
dIF/dt (A/µs)
dIF/dt (A/µs)
Fig. 5 - Typical Reverse Recovery Time vs. dIF/dt (Per Leg)
Fig. 8 - Typical dI(rec)M/dt vs. dIF/dt (Per Leg)
Revision: 26-Mar-14
Document Number: 94067
3
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
VS-HFA280NJ60CPbF
www.vishay.com
Vishay Semiconductors
ZthJC - Thermal Response
1
0.1
0.01
Single pulse
(thermal response)
0.001
0.00001
0.0001
D = 0.50
D = 0.33
D = 0.25
D = 0.17
D = 0.08
0.001
0.01
1
0.1
10
t1 - Rectangular Pulse Duration (s)
Fig. 9 - Maximum Thermal Impedance ZthJC Characteristics (Per Leg)
VR = 200 V
0.01 Ω
L = 70 μH
D.U.T.
dIF/dt
adjust
D
IRFP250
G
S
Fig. 10 - Reverse Recovery Parameter Test Circuit
(3)
trr
IF
ta
tb
0
Qrr
(2)
IRRM
(4)
0.5 IRRM
dI(rec)M/dt (5)
0.75 IRRM
(1) dIF/dt
(1) dIF/dt - rate of change of current
through zero crossing
(2) IRRM - peak reverse recovery current
(3) trr - reverse recovery time measured
from zero crossing point of negative
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current.
(4) Qrr - area under curve defined by trr
and IRRM
Qrr =
trr x IRRM
2
(5) dI(rec)M/dt - peak rate of change of
current during tb portion of trr
Fig. 11 - Reverse Recovery Waveform and Definitions
Revision: 26-Mar-14
Document Number: 94067
4
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
VS-HFA280NJ60CPbF
www.vishay.com
Vishay Semiconductors
L = 100 µH
IL(PK)
High-speed
switch
D.U.T.
Freewheel
diode
Rg = 25 Ω
+
Current
monitor
Decay
time
Vd = 50 V
V(AVAL)
VR(RATED)
Fig. 12 - Avalanche Test Circuit and Waveforms
ORDERING INFORMATION TABLE
Device code
VS-
HFA
280
NJ
60
C
PbF
1
2
3
4
5
6
7
1
-
Vishay Semiconductors product
2
-
HEXFRED® family, electron irradiated
3
-
Average current rating
4
-
NJ = TO-224
5
-
Voltage rating (600 V)
6
-
C = Common cathode
7
-
Lead (Pb)-free
LINKS TO RELATED DOCUMENTS
Dimensions
www.vishay.com/doc?95021
Revision: 26-Mar-14
Document Number: 94067
5
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Outline Dimensions
www.vishay.com
Vishay Semiconductors
TO-244
DIMENSIONS in millimeters (inches)
35 (1.37) REF.
13 (0.51)
7 (0.27)
6 (0.23)
17.5 (0.69)
16.5 (0.65)
40 (1.57)
80 (3.15)
Ø 5.2 (Ø 0.20)
3
12.6 (0.5)
Ø 7.2 (Ø 0.28)
(2 places)
3
1
2
21 (0.82)
20 (0.78)
¼" - 20 UNC
9.6 (0.37) MIN.
93 (3.66) MAX.
Revision: 24-Apr-15
Document Number: 95021
1
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000