NCP3020BGEVB_TEST_PROCEDURE.PDF - 124.0 KB

Test Procedure for the NCP3020B Evaluation Board
Figure 1: Test Setup
The following steps describe the test procedure for all these boards:
Suggested Equipment:
Current limited DC Power Supply (e.g. AGILENT 6645A) ……………………… 1pc
DC Volt-Meter able to measure up to 60 V DC (e.g. KEITHLEY 2000) ………… 2pcs
DC Amp-Meter able to measure up to 1 A DC (e.g. KEITHLEY 2000) ………......1pc
DC Amp-Meter able to measure up to 6 A DC (e.g. FLUKE 89 IV)……………… 1pc
DC Electronic Load (e.g. AGILENT 6060B) ……………………………………... 1pc
05/18/2010
-1-
www.onsemi.com
Test Procedure:
1. Connect the test setup as shown in Figure 1.
2. Apply an input voltage, VIN = 9-18 Vdc (Current Limit must be set to 6A)
5. Apply IOUT(load) = 0 A
4. Check that VOUT = 3.2 - 3.4 Vdc
6. Set IOUT to desired level 0 A- 7 A
7. Check that VOUT = 3.2 - 3.4 Vdc
8. Turn off the load
9. Turn off VIN
10. End of the test