NCP5104BAL36WEVB_TEST_PROCEDURE.PDF - 142.0 KB

Test Procedure for the NCP5104
29-Oct-07
A
Vac
A
V
V
J2 jumper
Table 1: Required Equipment
AC power source can be able to
two volt-meters
deliver 230Vrms or 110Vrms
One NCP5104 Evaluation Board
1 resistive load: 200 Ω / 50 W
two ampere-meters
Rload
200Ω
Test Procedure:
1. First of all check if you need or not the jumper #2 (J2 on the board close the diode bridge). This jumper
must be removed in case of European mains (230 Vac input voltage) and have to placed in case of US
mains (110 Vac). This jumper is used to build a voltage doublers just after the bridge diode in case of US
mains input voltage range.
2. Connect the test setup as shown above:
• AC source
• Voltmeter and Ampere meter on the load
• Load on the output
3. Apply 230 Vac if European mains or 110 Vac for the US mains on the input connector.
4. Compare Iload and Vload with the following table according your input mains voltage.
5. If you get the correct output and input voltage, you can now connect a 36 W fluorescent tube on the
output (see the ballast connection figure).
Test results:
Input mains
European
US
J2
Removed
Yes Î max
input voltage:
132 Vrms
Vin (Vrms)
230 V
Iin (Arms)
278 mA
Vload (Vrms)
303 V
Iload (Arms)
370 mA
110 V
514 mA
263 V
340 mA
Input connection
A
Vac
36 W
Tube
V
Output connection
Figure 1: Ballast connection