RLAT_HDR_RH3083MK_Fab_Lot_HP201682_1_W1.pdf

TID HDR RH3083MK HP201682 W1
Total Ionization Dose (TID) Test Results of the
RH3083MK Adjustable 2.8A Single Resistor Low
Dropout Regulator @ High Dose Rate (HDR)
HDR = 50 rads(Si)/s
10 October 2014
Duc Nguyen, Sana Rezgui
Acknowledgements
The authors would like to thank the S-Power Product Engineering and Design groups
from Linear Technology for their help with the board design and assembly as well as the
data collection pre- and post-irradiations. Special thanks are also for Thomas Shepherd
from Defense Microelectronics Activity (DMEA) for the extensive work for board setup
and continuous dosimetry monitoring throughout the ELDRS tests.
P a g e 1 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
TID HDR Testing of the RH3083MK Adjustable 2.8A
Single Resistor Low Dropout Regulator
Part Type Tested: RH3083MK Adjustable 2.8A Single Resistor Low Dropout Regulator
Traceability Information: Fab Lot # HP201682.1; Wafer # 1. See photograph of unit under test
in Appendix A.
Quantity of Units: 52 units received, 2 units for control, 25 units for biased irradiation, and 25
units for unbiased irradiation. Serial numbers 6-10, 16-20, 26-30, 36-40, and 46-50, and had all
pins tied to ground during irradiation. Serial numbers 1-5, 11-15, 21-25, 31-35, and 41-45 were
biased during irradiation. Serial numbers 51 and 52 were used as control. See Appendix B for
the radiation bias connection tables.
Radiation and Electrical Test Increments: 50 samples were divided into five groups of 10
each. Serial numbers 1-10 of group 1 were irradiated to 10 Krads(Si). Serial numbers 11-20 of
group 2 were irradiated to 20 Krads(Si). Serial numbers 21-30 of group 3 were irradiated to 50
Krads(Si). Serial numbers 31-40 of group 4 were irradiated to 100 Krads(Si). Serial numbers 4150 of group 5 were irradiated to 200 Krads(Si).
Radiation dose: 50 rads(Si)/sec.
Radiation Test Standard: MIL-STD-883 TM1019.9 Condition A.
Test Hardware and Software: LTX pre-irradiation test program EFR3083R.00; LTX postirradiation test program EFR3083R.00.
Facility and Radiation Source: Defense Micro Electronic Activity (DMEA) and Cobalt-60.
Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD883 and MIL-STD-750.
SUMMARY
ALL 52 PARTS PASSED THE ELECTRICAL TEST LIMITS AS
SPECIFIED IN THE DATASHEET AFTER EACH IRRADIATION
INCREMENT. ADDITIONAL INFORMATION CAN BE PROVIDED PER
REQUEST.
P a g e 2 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
1.0
Overview and Background
Among other radiation effects, Total Ionizing Dose (TID) may affect circuits’ electrical
characteristics, causing parametric and/or functional failures in integrated circuits. During
gamma-irradiations, TID-induced and transported electron-hole pairs may result in charge
trapping in the transistors’ dielectrics and interface regions, affecting hence the devices’ basic
features. Such effects warrant testing and monitoring of circuits to TID, after which annealing
and/or Time Dependent Effects (TDE) may take place, depending on the circuit’s design and
process technology. Hence is the requirement per Condition A (for high-dose rates ranging from
50 and 300 rads(Si)/sec) in TM1019, MIL-STD-883 to not exceed the allowed time from the end
of an incremented irradiation and an electrical test to more than one hour. Additionally, the total
time from the end of one incremental irradiation to the start of the next incremental step should
be less than two hours.
2.0
Radiation Facility and Test Equipment
The samples were irradiated at Defense Micro-Electronics Activity (DMEA) facility in
Sacramento, California. DMEA utilizes J.L. Shepherd model 81-22/484 to provide the dose-rate
of 50 rads(Si)/s. A special design screw-driven automatic cart inside the exposure tunnel
positions the Device-Under-Test (DUT) precisely and repeatedly from the source to attain
optimal rate verified by ion chamber detectors. See Appendix C for the certificate of dosimetry.
3.0
Test Conditions
The 50 test samples and two control units were electrically tested at 25°C prior to irradiation.
The parts were then placed in a lead/aluminum container and aligned with the radiation source,
Cobalt-60, at DMEA facility in Sacramento, California. During irradiation, five units of six
separate groups were biased at +3V and other five of similar groups had all pads grounded. Ten
units of group 1 were irradiated to 10 Krads(Si); group 2 to 20 Krads(Si); group 3 to 50
Krads(Si); group 4 to 100 Krads(Si); and group 5 to 200 Krads(Si). After irradiation, the samples
were transported in dry ice to Linear Technology testing facility. Testing was performed on the
two control units to confirm the operation of the test system prior to the electrical testing of the
52 units (50 irradiated and 2 control).
The criteria to pass the high dose-rate test is that five samples in each corresponding dose
group irradiated under electrical bias must pass the datasheet limits. If any of the tested
parameters of these five units do not meet the required limits then a failure-analysis of the part
should be conducted and if valid the lot will be scrapped.
P a g e 3 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
4.0
Tested Parameters
The following parameters were measured pre- and post-irradiations:
-
SET Pin Current (uA)
Output Offset Voltage (mV)
Load Regulation ISET (nA)
Load Regulation VOS (mV)
Line Regulation ISET (nA/V)
Line Regulation VOS (mV/V)
Minimum Load Current (mA) @ VIN = 1V, VCONTROL = 2V
Minimum Load Current (mA) @ VIN = 23V, VCONTROL = 25V
VCONTROL Dropout Voltage (V) @ VIN = 1V, ILOAD = 0.1A
VCONTROL Dropout Voltage (V) @ VIN = 1V, ILOAD = 1A
VCONTROL Dropout Voltage (V) @ VIN = 1V, ILOAD = 2.8A
VIN Dropout Voltage (V) @ VCONTROL = 2V, ILOAD = 0.1A
VIN Dropout Voltage (V) @ VCONTROL = 2V, ILOAD = 1A
VIN Dropout Voltage (V) @ VCONTROL = 2V, ILOAD = 2.8A
VCONTROL Pin Current (mA) @ VIN = 1V,VCONTROL = 2V, ILOAD = 0.1A
VCONTROL Pin Current (mA) @ VIN = 1V,VCONTROL = 2V, ILOAD = 1A
VCONTROL Pin Current (mA) @ VIN = 1V,VCONTROL = 2V, ILOAD = 2.8A
Current Limit (A) @ VIN = 5V,VCONTROL = 5V, VOUT = - 0.1V
Appendix D details the test conditions, minimum and maximum values at different accumulated
doses.
P a g e 4 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
5.0
Test Results
All 50 samples passed the post-irradiation electrical tests. All measurements of the 18 listed
parameters in section 4.0 are within the specification limits.
The used statistics in this report are based on the tolerance limits, which are bounds to gage the
quality of the manufactured products. It assumes that if the quality of the items is normally
distributed with known mean and known standard deviation, the two-sided tolerance limits can
be calculated by adding to and subtracting from mean the product of standard deviation and the
tolerance limit factor KTL where KTL is tabulated from a table of the inverse normal probability
distribution. The upper tolerance limit +KTL and the lower tolerance limit -KTL are
+KTL = mean + (KTL) (standard deviation)
-KTL = mean - (KTL) (standard deviation)
However, in most cases, mean and standard deviations are unknown and therefore it is
practical to estimate both of them from a sample. Hence the tolerance limit depends greatly on
the sample size. The Ps90%/90% KTL factor for a lot quality P of 0.9, confidence C of 0.9 with a
sample size of 5, can be found from the tabulated table (MIL-HDBK-814, page 94, table IX-B).
The KTL factor in this report is 2.742.
In the plots, the dotted lines with diamond markers are the average of the measured data points
of five samples irradiated under electrical bias while the dashed lines with X-markers are the
average of measured data points of five units irradiated with all pins tied to ground. The solid
lines with triangle markers are the average of the data points after the calculation of the KTL
statistics on the sample irradiated in the biased setup. The solid lines with square symbols are
the average of the measured points after the application of the KTL statistics on the five samples
irradiated with all pins grounded. The orange solid lines with circle markers are the specification
limits.
P a g e 5 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
ISET (uA) @ VIN = 1V, VC = 2V, IL = 1mA
51.50
Specification MAX
51.00
Ps90%/90% (+KTL) Biased
50.50
Ps90%/90% (+KTL) All GND'd
Average Biased
50.00
Average All GND'd
Ps90%/90% (-KTL) All GND'd
49.50
Ps90%/90% (-KTL) Biased
49.00
Specification MIN
48.50
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.1 Plot of SET Pin Current versus Total Dose
The measured data of five samples of five groups are within datasheet specification limits. Note
both pre-irradiation computed KTL data points are slightly out of the limits due to the small 5piece sample size.
P a g e 6 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.1: Raw data for SET Pin current versus total dose including the statistical calculations,
minimum specification, maximum specification, and the status of the test (PASS/FAIL) under the
orange headers)
Parameter
Units
6
7
8
9
10
1
2
3
4
5
16
17
18
19
20
11
12
13
14
15
26
27
28
29
30
21
22
23
24
25
36
37
38
39
40
31
32
33
34
35
46
47
48
49
50
41
42
43
44
45
51
52
ISET @ VIN=1V,VC=2V, IL =1mA
(uA)
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Control Unit
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Status (-KTL) All GND'd
Status (+KTL) All GND'd
Status (-KTL) Biased
Status (+KTL) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
50.545
50.071
50.049
49.877
50.246
50.374
49.857
50.122
50.203
50.162
50.261
50.053
49.854
49.946
49.697
49.838
49.792
49.786
49.962
49.912
50.080
50.005
50.123
49.916
50.088
50.288
50.062
49.952
49.938
49.966
50.147
49.758
49.890
50.082
49.866
49.811
50.145
50.189
50.051
50.054
50.106
49.723
49.911
50.038
49.969
50.036
50.095
50.625
49.826
50.167
50.163
49.881
10
50.561
50.014
50.046
49.910
50.129
50.380
49.888
50.088
50.233
50.140
20
50
100
200
50.163
49.881
50.163
49.881
50.163
49.881
50.163
49.881
50.117
49.689
49.912
50.075
49.899
49.959
50.034
50.568
49.781
50.015
50.163
49.881
50.158
0.253
50.851
49.464
50.132
0.252
50.824
49.440
49.985
0.212
50.566
49.403
50.020
0.150
50.432
49.607
49.927
0.162
50.372
49.482
49.938
0.170
50.403
49.473
50.144
0.187
50.655
49.632
49.5
PASS
PASS
50.5
FAIL
PASS
50.146
0.182
50.644
49.647
49.0
PASS
PASS
51.0
PASS
PASS
49.833
0.122
50.168
49.499
49.0
PASS
PASS
51.0
PASS
PASS
49.984
0.153
50.405
49.564
49.0
PASS
PASS
51.0
PASS
PASS
50.037
0.136
50.410
49.664
49.0
PASS
PASS
51.0
PASS
PASS
50.071
0.295
50.880
49.263
49.0
PASS
PASS
51.0
PASS
PASS
FAIL
FAIL
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
FAIL
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
50.321
50.061
49.842
49.913
49.786
49.820
49.819
49.659
49.999
49.871
50.118
50.017
50.135
49.764
50.066
50.256
49.915
49.900
49.898
49.954
50.153
49.713
49.898
49.997
49.874
49.835
50.144
50.179
50.026
50.002
P a g e 7 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Output Offset V (V) @ VIN = 1V, VC = 2V, IL = 1mA
6.00
Specification MAX
4.00
Ps90%/90% (+KTL) Biased
2.00
Ps90%/90% (+KTL) All GND'd
Average Biased
0.00
Average All GND'd
Ps90%/90% (-KTL) Biased
-2.00
Ps90%/90% (-KTL) All GND'd
-4.00
Specification MIN
-6.00
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.2: Plot of Output Offset Voltage versus Total Dose
All samples passed the Output Offset Voltage parameter test. Note the computed +KTL All
GND’d data point at 100 Krad(Si) is outside the maximum limit due to the small 5-piece sample
size.
P a g e 8 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.2: Raw data for output offset voltage versus total dose including the statistical
calculations, maximum specification, and the status of the test (PASS/FAIL under the second
orange header)
Parameter
Units
6
7
8
9
10
1
2
3
4
5
16
17
18
19
20
11
12
13
14
15
26
27
28
29
30
21
22
23
24
25
36
37
38
39
40
31
32
33
34
35
46
47
48
49
50
41
42
43
44
45
51
52
VOS @ VIN=1V,VC = 2V,IL = 1mA
(V)
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Control Unit
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
0.094
-0.079
-0.444
-0.516
0.195
-0.196
-0.144
-0.736
-0.856
-0.590
0.497
-1.270
-0.541
0.464
0.749
0.316
0.101
-0.208
-0.190
0.174
1.590
-1.257
-1.241
-0.969
0.306
-0.519
-0.335
0.065
-0.543
1.699
-0.117
0.989
0.613
2.753
-1.475
1.305
-0.871
-1.629
0.390
0.022
-0.166
-1.251
-0.363
-1.089
0.064
-1.202
0.363
1.149
-0.738
-0.143
-0.168
0.146
10
0.080
-0.043
-0.562
-0.316
0.519
-0.394
-0.341
-0.742
-0.753
-0.493
20
50
100
200
-0.168
0.146
-0.168
0.146
-0.168
0.146
-0.168
0.146
0.202
-1.002
0.155
-1.036
0.300
-0.652
0.698
1.214
-0.429
0.182
-0.168
0.146
-0.150
0.318
0.722
-1.021
-0.064
0.410
1.061
-1.189
0.049
0.855
2.395
-2.296
-0.152
1.243
3.257
-3.561
0.613
1.569
4.916
-3.690
-0.276
0.680
1.589
-2.141
-0.504
0.320
0.374
-1.382
-4.0
PASS
PASS
4.0
PASS
PASS
-0.545
0.193
-0.015
-1.074
-4.5
PASS
PASS
4.5
PASS
PASS
0.012
0.272
0.757
-0.734
-4.5
PASS
PASS
4.5
PASS
PASS
0.283
0.770
2.394
-1.828
-4.5
PASS
PASS
4.5
PASS
PASS
-0.085
1.015
2.697
-2.867
-4.5
PASS
PASS
4.5
PASS
PASS
0.203
0.774
2.325
-1.920
-4.5
PASS
PASS
4.5
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
FAIL
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
0.493
-1.205
-0.252
0.549
0.662
0.066
0.056
-0.190
-0.287
0.413
1.707
-1.315
-0.994
-0.651
0.493
-0.157
0.135
0.171
-0.340
1.608
-0.050
0.730
0.770
2.964
-1.348
1.260
-0.791
-1.323
0.437
-0.007
P a g e 9 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Load Reg ISET (nA) @ IL = 1mA to 2.8A
400
Specification MAX
300
Ps90%/90% (+KTL) All GND'd
200
Ps90%/90% (+KTL) Biased
100
Average All GND'd
0
Average Biased
-100
Ps90%/90% (-KTL) Biased
-200
Ps90%/90% (-KTL) All GND'd
-300
Specification MIN
-400
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.3: Plot of Load Regulation ISET versus Total Dose
All measured post-irradiation data points are within the datasheet specification limits.
P a g e 10 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.3: Raw data for Load Regulation ISET versus total dose including the statistical
calculations, minimum specification, maximum specification, and the status of the test
(PASS/FAIL).
Parameter Load Reg ISET @ IL = 1mA to 2.8A
Units
(nA)
6
All GND'd Irradiation
7
All GND'd Irradiation
8
All GND'd Irradiation
9
All GND'd Irradiation
10
All GND'd Irradiation
1
Biased Irradiation
2
Biased Irradiation
3
Biased Irradiation
4
Biased Irradiation
5
Biased Irradiation
16
All GND'd Irradiation
17
All GND'd Irradiation
18
All GND'd Irradiation
19
All GND'd Irradiation
20
All GND'd Irradiation
11
Biased Irradiation
12
Biased Irradiation
13
Biased Irradiation
14
Biased Irradiation
15
Biased Irradiation
26
All GND'd Irradiation
27
All GND'd Irradiation
28
All GND'd Irradiation
29
All GND'd Irradiation
30
All GND'd Irradiation
21
Biased Irradiation
22
Biased Irradiation
23
Biased Irradiation
24
Biased Irradiation
25
Biased Irradiation
36
All GND'd Irradiation
37
All GND'd Irradiation
38
All GND'd Irradiation
39
All GND'd Irradiation
40
All GND'd Irradiation
31
Biased Irradiation
32
Biased Irradiation
33
Biased Irradiation
34
Biased Irradiation
35
Biased Irradiation
46
All GND'd Irradiation
47
All GND'd Irradiation
48
All GND'd Irradiation
49
All GND'd Irradiation
50
All GND'd Irradiation
41
Biased Irradiation
42
Biased Irradiation
43
Biased Irradiation
44
Biased Irradiation
45
Biased Irradiation
51
Control Unit
52
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
52.867
57.611
51.441
53.333
50.451
49.840
53.318
59.226
49.768
55.908
54.162
54.162
59.415
61.671
55.719
58.833
50.160
50.568
59.998
42.754
54.832
57.014
54.890
53.362
56.389
56.025
42.142
56.476
50.786
53.667
58.266
55.341
54.453
53.740
50.597
58.659
55.195
57.596
48.574
49.171
53.071
56.389
55.894
32.960
54.279
58.440
53.813
57.698
59.692
54.468
57.291
49.680
10
57.567
49.986
49.797
50.029
42.826
50.990
50.670
48.298
49.244
58.644
20
50
100
200
57.291
49.680
57.291
49.680
57.291
49.680
57.291
49.680
43.045
58.921
53.333
29.118
50.422
54.308
44.645
45.417
43.161
48.574
57.291
49.680
53.141
2.748
60.677
45.604
50.041
5.214
64.339
35.743
53.726
3.369
62.963
44.488
40.664
1.892
45.851
35.476
41.022
5.473
56.029
26.014
46.968
11.503
78.510
15.425
53.612
4.059
64.741
42.484
-200
PASS
PASS
200
PASS
PASS
51.569
4.102
62.817
40.321
-300
PASS
PASS
300
PASS
PASS
48.094
4.331
59.969
36.219
-300
PASS
PASS
300
PASS
PASS
49.794
7.999
71.727
27.861
-300
PASS
PASS
300
PASS
PASS
47.204
3.684
57.304
37.103
-300
PASS
PASS
300
PASS
PASS
47.221
4.428
59.362
35.079
-300
PASS
PASS
300
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
44.063
47.716
53.202
66.182
57.466
55.312
44.034
46.479
46.173
48.472
40.367
41.488
42.812
40.964
37.689
62.544
45.664
42.332
52.372
46.057
47.075
40.891
40.789
43.961
32.393
48.763
44.456
51.892
42.608
48.298
P a g e 11 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
4.00
Load Reg VOS (mV) @ IL = 1mA to 2.8A
Specification MAX
3.00
Ps90%/90% (+KTL) All GND'd
2.00
Ps90%/90% (+KTL) Biased
1.00
Average All GND'd
0.00
Average Biased
-1.00
Ps90%/90% (-KTL) All GND'd
-2.00
Ps90%/90% (-KTL) Biased
-3.00
Specification MIN
-4.00
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.4: Plot of Load Regulation VOS versus Total Dose
All measured data points are within datasheet specification limits.
P a g e 12 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.4: Raw data for load regulation VOS versus total dose including the statistical
calculations, minimum specification, maximum specification, and the status of the test
(PASS/FAIL).
Parameter
Units
6
7
8
9
10
1
2
3
4
5
16
17
18
19
20
11
12
13
14
15
26
27
28
29
30
21
22
23
24
25
36
37
38
39
40
31
32
33
34
35
46
47
48
49
50
41
42
43
44
45
51
52
Load Reg VOS @ IL =1mA to 2.8A
(mV)
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Control Unit
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
-0.1036
-0.0665
-0.0785
-0.0573
-0.0599
-0.1066
-0.1201
-0.0659
-0.0693
-0.0881
-0.0852
-0.0564
-0.0499
-0.1553
-0.1492
-0.1294
-0.0924
-0.0867
-0.0740
-0.0913
-0.1197
-0.0604
-0.0006
-0.0024
-0.0939
-0.0268
-0.0511
-0.0739
-0.0669
-0.1548
-0.0662
-0.1141
-0.1560
-0.2106
-0.0644
-0.1249
-0.0769
0.0030
-0.0851
-0.0732
-0.0674
-0.0843
-0.0719
-0.0503
-0.1330
-0.0421
-0.1234
-0.1627
-0.0842
-0.0929
-0.1151
-0.0756
10
-0.1077
-0.0802
-0.0777
-0.0326
-0.0288
-0.0915
-0.0994
-0.0599
-0.0464
-0.0585
20
50
100
200
-0.0732
0.0189
-0.0214
-0.1250
-0.0654
0.0338
0.0273
-0.1581
-0.0910
0.0503
0.0468
-0.2288
-0.0462
0.0509
0.0935
-0.1858
-0.1449
0.0671
0.0391
-0.3289
-0.1471
0.0243
-0.0803
-0.2138
-0.0900
0.0234
-0.0258
-0.1542
-3.0
PASS
PASS
3.0
PASS
PASS
-0.0712
0.0230
-0.0081
-0.1342
-3.5
PASS
PASS
3.5
PASS
PASS
-0.0832
0.0199
-0.0287
-0.1378
-3.5
PASS
PASS
3.5
PASS
PASS
-0.0721
0.0421
0.0433
-0.1876
-3.5
PASS
PASS
3.5
PASS
PASS
-0.0963
0.0508
0.0430
-0.2356
-3.5
PASS
PASS
3.5
PASS
PASS
-0.1788
0.0461
-0.0523
-0.3053
-3.5
PASS
PASS
3.5
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
-0.0956
-0.0542
-0.0432
-0.1199
-0.1420
-0.1133
-0.0883
-0.0796
-0.0589
-0.0762
-0.0974
-0.0466
0.0153
-0.0067
-0.0954
-0.0323
-0.0690
-0.0583
-0.0575
-0.1435
-0.0882
-0.1160
-0.1739
-0.2491
-0.0973
-0.1308
-0.0912
-0.0100
-0.1294
-0.1200
-0.1280
-0.1360
-0.1438
-0.1382
-0.1894
-0.1208
-0.2045
-0.2421
-0.1624
-0.1641
-0.1151 -0.1151 -0.1151 -0.1151 -0.1151
-0.0756 -0.0756 -0.0756 -0.0756 -0.0756
P a g e 13 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Line Reg ISET (nA/V) @ VC = 2V to 25V
15.000
Specification MAX
10.000
Ps90%/90% (+KTL) All GND'd
5.000
Ps90%/90% (+KTL) Biased
Average All GND'd
0.000
Average Biased
Ps90%/90% (-KTL) Biased
-5.000
Ps90%/90% (-KTL) All GND'd
-10.000
Specification MIN
-15.000
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.5: Plot of Line Regulation ISET versus Total Dose
The measured post-irradiation average data points are within datasheet specification limits.
P a g e 14 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.5: Raw data for line regulation ISET versus total dose including the statistical
calculations, minimum specification, maximum specification, and the status of the test
(PASS/FAIL)
Parameter
Units
6
7
8
9
10
1
2
3
4
5
16
17
18
19
20
11
12
13
14
15
26
27
28
29
30
21
22
23
24
25
36
37
38
39
40
31
32
33
34
35
46
47
48
49
50
41
42
43
44
45
51
52
Line Reg ISET @ VC = 2V to 25V
(nA/V)
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Control Unit
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
0.268
0.150
0.239
0.135
0.285
0.245
0.111
0.270
0.279
0.308
0.061
0.251
0.198
0.355
0.185
0.227
0.150
0.164
0.268
0.190
0.251
0.330
0.178
0.283
0.269
0.283
0.302
0.241
0.292
0.382
0.271
0.150
0.283
0.232
0.195
0.171
0.301
0.357
0.227
0.281
0.185
0.238
0.251
0.267
0.302
0.330
0.265
0.338
0.178
0.356
0.296
0.226
10
0.500
0.283
0.459
0.497
0.521
0.371
0.443
0.493
0.570
0.273
20
50
100
200
0.296
0.226
0.296
0.226
0.296
0.226
0.296
0.226
0.613
0.164
0.200
0.105
0.260
0.320
0.123
0.188
0.361
0.229
0.296
0.226
0.216
0.069
0.404
0.027
0.452
0.097
0.718
0.186
0.399
0.107
0.691
0.106
0.787
0.094
1.045
0.529
0.647
0.109
0.947
0.348
0.269
0.201
0.819
-0.282
0.243
0.077
0.454
0.031
-8
PASS
PASS
8
PASS
PASS
0.430
0.114
0.742
0.118
-10
PASS
PASS
10
PASS
PASS
0.417
0.190
0.938
-0.104
-10
PASS
PASS
10
PASS
PASS
0.668
0.132
1.029
0.306
-10
PASS
PASS
10
PASS
PASS
0.574
0.082
0.798
0.350
-10
PASS
PASS
10
PASS
PASS
0.244
0.097
0.510
-0.022
-10
PASS
PASS
10
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
0.379
0.552
0.455
0.264
0.344
0.335
0.341
0.495
0.704
0.209
0.891
0.867
0.740
0.774
0.662
0.514
0.863
0.722
0.609
0.632
0.642
0.509
0.599
0.681
0.805
0.448
0.574
0.677
0.583
0.588
P a g e 15 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Line Reg VOS (mV/V) @ VC = 2V to 25V
0.0500
0.0400
Specification MAX
0.0300
Ps90%/90% (+KTL) All GND'd
0.0200
Ps90%/90% (+KTL) Biased
0.0100
Average All GND'd
0.0000
Average Biased
-0.0100
Ps90%/90% (-KTL) Biased
-0.0200
-0.0300
Ps90%/90% (-KTL) All GND'd
-0.0400
Specification MIN
-0.0500
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.6: Plot of Line Regulation VOS versus Total Dose
All measured average data points are within datasheet specification limits.
P a g e 16 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.6: Raw data for line regulation VOS versus total dose including the statistical
calculations, minimum specification, maximum specification, and the status of the test
(PASS/FAIL)
Parameter
Units
6
7
8
9
10
1
2
3
4
5
16
17
18
19
20
11
12
13
14
15
26
27
28
29
30
21
22
23
24
25
36
37
38
39
40
31
32
33
34
35
46
47
48
49
50
41
42
43
44
45
51
52
Line Reg VOS @ VC = 2V to 25V
(mV)
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Control Unit
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
0.0018
0.0026
0.0027
0.0043
0.0036
0.0039
0.0019
0.0028
0.0032
0.0031
0.0025
0.0029
0.0026
0.0036
0.0024
0.0027
0.0027
0.0028
0.0030
0.0034
0.0027
0.0040
0.0047
0.0032
0.0029
0.0039
0.0027
0.0026
0.0040
0.0019
0.0021
0.0025
0.0020
0.0018
0.0036
0.0028
0.0031
0.0045
0.0036
0.0026
0.0034
0.0034
0.0027
0.0017
0.0019
0.0039
0.0032
0.0015
0.0034
0.0029
0.0032
0.0033
10
0.0030
0.0039
0.0041
0.0046
0.0042
0.0044
0.0029
0.0040
0.0030
0.0035
20
50
100
200
0.0032
0.0033
0.0032
0.0033
0.0032
0.0033
0.0032
0.0033
0.0092
0.0080
0.0103
0.0081
0.0071
0.0116
0.0115
0.0089
0.0106
0.0105
0.0032
0.0033
0.0030
0.0010
0.0056
0.0003
0.0040
0.0006
0.0056
0.0024
0.0046
0.0005
0.0059
0.0033
0.0058
0.0007
0.0078
0.0039
0.0058
0.0016
0.0101
0.0016
0.0085
0.0012
0.0119
0.0051
0.0030
0.0007
0.0050
0.0010
-0.020
PASS
PASS
0.020
PASS
PASS
0.0036
0.0006
0.0053
0.0018
-0.025
PASS
PASS
0.025
PASS
PASS
0.0044
0.0003
0.0052
0.0036
-0.025
PASS
PASS
0.025
PASS
PASS
0.0049
0.0016
0.0093
0.0004
-0.025
PASS
PASS
0.025
PASS
PASS
0.0078
0.0013
0.0113
0.0043
-0.030
PASS
PASS
0.030
PASS
PASS
0.0106
0.0011
0.0135
0.0077
-0.040
PASS
PASS
0.040
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
0.0058
0.0046
0.0045
0.0049
0.0030
0.0046
0.0043
0.0040
0.0045
0.0047
0.0048
0.0057
0.0061
0.0067
0.0060
0.0067
0.0033
0.0050
0.0061
0.0032
0.0064
0.0058
0.0064
0.0032
0.0073
0.0063
0.0074
0.0094
0.0071
0.0089
P a g e 17 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Min IL (mA) @ VIN =1V,VC =2V, VOUT = 0.1V
0.55
Specification MAX
0.5
Ps90%/90% (+KTL) All GND'd
0.45
Average All GND'd
0.4
Ps90%/90% (-KTL) All GND'd
Ps90%/90% (+KTL) Biased
0.35
Average Biased
0.3
Ps90%/90% (-KTL) Biased
0.25
0.2
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.7: Plot of Minimum Load Current (@ VIN = 1V) versus Total Dose
The average measured values of all samples pass the datasheet specification maximum limit.
P a g e 18 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.7: Raw data table for minimum load current (@ VIN = 1V) versus total dose including the
statistical calculations, maximum specification, and the status of the test (PASS/FAIL)
Total Dose
Parameter Min IL @ VIN=1V,VC=2V,VOUT = 0.1V
Units
(mA)
0
10
6
All GND'd Irradiation
0.347
0.346
7
All GND'd Irradiation
0.343
0.341
8
All GND'd Irradiation
0.347
0.344
9
All GND'd Irradiation
0.341
0.340
10
All GND'd Irradiation
0.349
0.345
1
Biased Irradiation
0.343
0.343
2
Biased Irradiation
0.341
0.339
3
Biased Irradiation
0.343
0.342
4
Biased Irradiation
0.344
0.344
5
Biased Irradiation
0.344
0.340
16
All GND'd Irradiation
0.343
17
All GND'd Irradiation
0.342
18
All GND'd Irradiation
0.341
19
All GND'd Irradiation
0.344
20
All GND'd Irradiation
0.337
11
Biased Irradiation
-0.343
12
Biased Irradiation
0.341
13
Biased Irradiation
0.339
14
Biased Irradiation
0.346
15
Biased Irradiation
0.342
26
All GND'd Irradiation
0.341
27
All GND'd Irradiation
0.341
28
All GND'd Irradiation
0.339
29
All GND'd Irradiation
0.340
30
All GND'd Irradiation
0.342
21
Biased Irradiation
0.342
22
Biased Irradiation
0.340
23
Biased Irradiation
0.341
24
Biased Irradiation
0.339
25
Biased Irradiation
0.340
36
All GND'd Irradiation
0.341
37
All GND'd Irradiation
0.340
38
All GND'd Irradiation
0.344
39
All GND'd Irradiation
0.347
40
All GND'd Irradiation
0.341
31
Biased Irradiation
0.339
32
Biased Irradiation
0.345
33
Biased Irradiation
0.341
34
Biased Irradiation
0.340
35
Biased Irradiation
0.344
46
All GND'd Irradiation
0.349
47
All GND'd Irradiation
0.341
48
All GND'd Irradiation
0.339
49
All GND'd Irradiation
0.346
50
All GND'd Irradiation
0.346
41
Biased Irradiation
0.343
42
Biased Irradiation
0.348
43
Biased Irradiation
0.347
44
Biased Irradiation
0.343
45
Biased Irradiation
0.345
51
Control Unit
0.348
0.348
52
Control Unit
0.341
0.341
All GND'd Irradiation Statistics
Average All GND'd
0.346
0.343
Std Dev All GND'd
0.003
0.003
Ps90%/90% (+KTL) All GND'd
0.354
0.350
Ps90%/90% (-KTL) All GND'd
0.337
0.336
Biased Irradiation Statistics
Average Biased
0.343
0.342
Std Dev Biased
0.001
0.002
Ps90%/90% (+KTL) Biased
0.347
0.348
Ps90%/90% (-KTL) Biased
0.339
0.336
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
0.5
0.5
Status (Measurements) All GND'd
PASS
PASS
Status (Measurements) Biased
PASS
PASS
(Krad(Si)) @ 50 rads(Si)/s
20
50
100
200
0.342
0.341
0.337
0.339
0.334
0.339
0.336
0.333
0.341
0.337
0.337
0.335
0.334
0.335
0.336
0.332
0.341
0.329
0.329
0.327
0.336
0.334
0.340
0.343
0.338
0.320
0.323
0.321
0.322
0.323
0.348
0.341
0.348
0.341
0.348
0.341
0.359
0.344
0.348
0.351
0.343
0.300
0.306
0.305
0.302
0.300
0.348
0.341
0.339
0.003
0.346
0.332
0.336
0.001
0.338
0.333
0.338
0.003
0.347
0.329
0.349
0.007
0.367
0.331
0.337
0.003
0.345
0.330
0.332
0.005
0.346
0.317
0.322
0.001
0.325
0.318
0.302
0.003
0.310
0.295
0.5
PASS
PASS
0.5
PASS
PASS
0.5
PASS
PASS
0.5
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
P a g e 19 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Min IL (mA) @ VIN = 23V, VC = 25V,VOUT =.1V
1.1
Specification MAX
1
Ps90%/90% (+KTL) All GND'd
0.9
Average All GND'd
0.8
Ps90%/90% (-KTL) All GND'd
0.7
Ps90%/90% (+KTL) Biased
0.6
Average Biased
Ps90%/90% (-KTL) Biased
0.5
0.4
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.8: Plot of Minimum Load Current (@ VIN = 23V) versus Total Dose
The average measured values of samples are within the datasheet maximum limit.
P a g e 20 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.8: Raw data table for minimum IL (@ VIN = 23V) versus total dose including the
statistical calculations, maximum specification, and the status of the test (PASS/FAIL)
Parameter Min IL @VIN=23V,VC=25V,VOUT =.1V
Units
(mA)
6
All GND'd Irradiation
7
All GND'd Irradiation
8
All GND'd Irradiation
9
All GND'd Irradiation
10
All GND'd Irradiation
1
Biased Irradiation
2
Biased Irradiation
3
Biased Irradiation
4
Biased Irradiation
5
Biased Irradiation
16
All GND'd Irradiation
17
All GND'd Irradiation
18
All GND'd Irradiation
19
All GND'd Irradiation
20
All GND'd Irradiation
11
Biased Irradiation
12
Biased Irradiation
13
Biased Irradiation
14
Biased Irradiation
15
Biased Irradiation
26
All GND'd Irradiation
27
All GND'd Irradiation
28
All GND'd Irradiation
29
All GND'd Irradiation
30
All GND'd Irradiation
21
Biased Irradiation
22
Biased Irradiation
23
Biased Irradiation
24
Biased Irradiation
25
Biased Irradiation
36
All GND'd Irradiation
37
All GND'd Irradiation
38
All GND'd Irradiation
39
All GND'd Irradiation
40
All GND'd Irradiation
31
Biased Irradiation
32
Biased Irradiation
33
Biased Irradiation
34
Biased Irradiation
35
Biased Irradiation
46
All GND'd Irradiation
47
All GND'd Irradiation
48
All GND'd Irradiation
49
All GND'd Irradiation
50
All GND'd Irradiation
41
Biased Irradiation
42
Biased Irradiation
43
Biased Irradiation
44
Biased Irradiation
45
Biased Irradiation
51
Control Unit
52
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
0.537
0.532
0.537
0.533
0.543
0.532
0.532
0.533
0.535
0.533
0.536
0.531
0.531
0.533
0.527
0.535
0.533
0.528
0.539
0.530
0.535
0.531
0.530
0.536
0.531
0.534
0.530
0.534
0.530
0.531
0.530
0.527
0.541
0.540
0.534
0.527
0.537
0.534
0.534
0.533
0.545
0.535
0.536
0.541
0.537
0.540
0.543
0.542
0.537
0.541
0.540
0.534
10
0.536
0.533
0.536
0.535
0.543
0.533
0.531
0.532
0.536
0.532
20
50
100
200
0.540
0.534
0.540
0.534
0.540
0.534
0.540
0.534
0.601
0.565
0.582
0.587
0.560
0.526
0.528
0.527
0.523
0.526
0.540
0.534
0.536
0.005
0.549
0.524
0.537
0.004
0.547
0.526
0.532
0.003
0.542
0.523
0.534
0.002
0.540
0.529
0.542
0.009
0.566
0.518
0.579
0.017
0.625
0.534
0.533
0.001
0.536
0.529
0.533
0.002
0.539
0.526
0.532
0.005
0.545
0.518
0.530
0.003
0.538
0.522
0.527
0.004
0.538
0.515
0.526
0.002
0.531
0.521
1
PASS
PASS
1
PASS
PASS
1
PASS
PASS
1
PASS
PASS
1
PASS
PASS
1
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
0.538
0.531
0.531
0.533
0.528
0.535
0.532
0.525
0.537
0.528
0.535
0.533
0.533
0.538
0.533
0.530
0.534
0.530
0.526
0.530
0.536
0.531
0.550
0.550
0.543
0.520
0.532
0.528
0.527
0.526
P a g e 21 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
VC Dropout Voltage (V) @ VIN =1V,IL =0.1A
1.50
1.45
Specification MAX
1.40
Ps90%/90% (+KTL) All GND'd
1.35
Average All GND'd
1.30
Ps90%/90% (-KTL) All GND'd
1.25
Ps90%/90% (+KTL) Biased
1.20
Average Biased
1.15
Ps90%/90% (-KTL) Biased
1.10
1.05
1.00
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.9: Plot of VCONTROL Dropout Voltage (@ IL = 0.1A) versus Total Dose
The average measured values are within datasheet specification maximum limit.
P a g e 22 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.9: Raw data table for VCONTROL dropout voltage (IL = 0.1A) versus total dose including
the statistical calculations, maximum specification, and the status of the test (PASS/FAIL)
Parameter VC Dropout (V) @ VIN =1V,IL =0.1A
Units
(V)
6
All GND'd Irradiation
7
All GND'd Irradiation
8
All GND'd Irradiation
9
All GND'd Irradiation
10
All GND'd Irradiation
1
Biased Irradiation
2
Biased Irradiation
3
Biased Irradiation
4
Biased Irradiation
5
Biased Irradiation
16
All GND'd Irradiation
17
All GND'd Irradiation
18
All GND'd Irradiation
19
All GND'd Irradiation
20
All GND'd Irradiation
11
Biased Irradiation
12
Biased Irradiation
13
Biased Irradiation
14
Biased Irradiation
15
Biased Irradiation
26
All GND'd Irradiation
27
All GND'd Irradiation
28
All GND'd Irradiation
29
All GND'd Irradiation
30
All GND'd Irradiation
21
Biased Irradiation
22
Biased Irradiation
23
Biased Irradiation
24
Biased Irradiation
25
Biased Irradiation
36
All GND'd Irradiation
37
All GND'd Irradiation
38
All GND'd Irradiation
39
All GND'd Irradiation
40
All GND'd Irradiation
31
Biased Irradiation
32
Biased Irradiation
33
Biased Irradiation
34
Biased Irradiation
35
Biased Irradiation
46
All GND'd Irradiation
47
All GND'd Irradiation
48
All GND'd Irradiation
49
All GND'd Irradiation
50
All GND'd Irradiation
41
Biased Irradiation
42
Biased Irradiation
43
Biased Irradiation
44
Biased Irradiation
45
Biased Irradiation
51
Control Unit
52
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
1.255
1.251
1.253
1.241
1.235
1.254
1.246
1.251
1.255
1.251
1.237
1.253
1.237
1.246
1.244
1.235
1.232
1.247
1.236
1.248
1.238
1.251
1.247
1.232
1.246
1.237
1.243
1.238
1.241
1.232
1.248
1.246
1.240
1.246
1.245
1.245
1.239
1.236
1.242
1.249
1.237
1.236
1.228
1.233
1.245
1.234
1.242
1.243
1.237
1.238
1.245
1.235
10
1.259
1.211
1.260
1.245
1.239
1.259
1.254
1.257
1.263
1.256
20
50
100
200
1.245
1.235
1.245
1.235
1.245
1.235
1.245
1.235
1.309
1.310
1.310
1.311
1.315
1.280
1.288
1.288
1.283
1.287
1.245
1.235
1.247
0.009
1.271
1.223
1.243
0.020
1.298
1.188
1.254
0.006
1.272
1.237
1.268
0.007
1.287
1.249
1.254
0.050
1.392
1.116
1.311
0.002
1.317
1.304
1.252
0.004
1.262
1.242
1.258
0.004
1.267
1.248
1.250
0.006
1.265
1.234
1.259
0.010
1.286
1.232
1.258
0.035
1.355
1.162
1.285
0.004
1.295
1.275
1.40
PASS
PASS
1.41
PASS
PASS
1.41
PASS
PASS
1.42
PASS
PASS
1.43
PASS
PASS
1.45
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
1.250
1.263
1.248
1.259
1.252
1.246
1.243
1.256
1.247
1.256
1.268
1.272
1.272
1.256
1.272
1.266
1.243
1.262
1.266
1.258
1.290
1.294
1.289
1.197
1.201
1.275
1.272
1.268
1.196
1.282
P a g e 23 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
1.55
VC Dropout Voltage (V) @ VIN =1V,IL = 1A
Specification MAX
1.50
Ps90%/90% (+KTL) All
GND'd
1.45
Average All GND'd
1.40
Ps90%/90% (-KTL) All
GND'd
1.35
Ps90%/90% (+KTL) Biased
1.30
Average Biased
1.25
Ps90%/90% (-KTL) Biased
1.20
1.15
1.10
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.10: Plot of VCONTROL Dropout Voltage (@ IL = 1A) versus Total Dose
The average measured values of samples are within datasheet limits.
P a g e 24 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.10: Raw data table for VCONTROL dropout voltage (IL = 1A) versus total dose including the
statistical calculations, maximum specification, and the status of the test (PASS/FAIL)
Parameter VC Dropout (V) @ VIN =1V,IL = 1A
Units
(V)
6
All GND'd Irradiation
7
All GND'd Irradiation
8
All GND'd Irradiation
9
All GND'd Irradiation
10
All GND'd Irradiation
1
Biased Irradiation
2
Biased Irradiation
3
Biased Irradiation
4
Biased Irradiation
5
Biased Irradiation
16
All GND'd Irradiation
17
All GND'd Irradiation
18
All GND'd Irradiation
19
All GND'd Irradiation
20
All GND'd Irradiation
11
Biased Irradiation
12
Biased Irradiation
13
Biased Irradiation
14
Biased Irradiation
15
Biased Irradiation
26
All GND'd Irradiation
27
All GND'd Irradiation
28
All GND'd Irradiation
29
All GND'd Irradiation
30
All GND'd Irradiation
21
Biased Irradiation
22
Biased Irradiation
23
Biased Irradiation
24
Biased Irradiation
25
Biased Irradiation
36
All GND'd Irradiation
37
All GND'd Irradiation
38
All GND'd Irradiation
39
All GND'd Irradiation
40
All GND'd Irradiation
31
Biased Irradiation
32
Biased Irradiation
33
Biased Irradiation
34
Biased Irradiation
35
Biased Irradiation
46
All GND'd Irradiation
47
All GND'd Irradiation
48
All GND'd Irradiation
49
All GND'd Irradiation
50
All GND'd Irradiation
41
Biased Irradiation
42
Biased Irradiation
43
Biased Irradiation
44
Biased Irradiation
45
Biased Irradiation
51
Control Unit
52
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
1.2555
1.2534
1.2550
1.2413
1.2367
1.2565
1.2478
1.2533
1.2574
1.2527
1.2394
1.2546
1.2392
1.2466
1.2451
1.2373
1.2333
1.2488
1.2376
1.2490
1.2406
1.2513
1.2473
1.2345
1.2466
1.2396
1.2449
1.2387
1.2417
1.2339
1.2500
1.2481
1.2411
1.2479
1.2451
1.2467
1.2413
1.2367
1.2443
1.2498
1.2375
1.2370
1.2303
1.2350
1.2467
1.2364
1.2439
1.2456
1.2390
1.2399
1.2460
1.2370
10
1.2619
1.3046
1.2618
1.2471
1.2410
1.2601
1.2559
1.2573
1.2640
1.2572
20
50
100
200
1.2460
1.2370
1.2460
1.2370
1.2460
1.2370
1.2460
1.2370
1.3112
1.3125
1.3129
1.3135
1.3174
1.2841
1.2928
1.2923
1.2863
1.2897
1.2460
1.2370
1.2484
0.0088
1.2724
1.2244
1.2633
0.0248
1.3314
1.1952
1.2558
0.0063
1.2731
1.2385
1.2704
0.0067
1.2887
1.2521
1.2894
0.0051
1.3035
1.2754
1.3135
0.0023
1.3199
1.3071
1.2535
0.0038
1.2639
1.2432
1.2589
0.0032
1.2678
1.2500
1.2512
0.0050
1.2650
1.2373
1.2618
0.0101
1.2895
1.2340
1.2783
0.0057
1.2938
1.2627
1.2891
0.0038
1.2995
1.2786
1.45
PASS
PASS
1.46
PASS
PASS
1.46
PASS
PASS
1.47
PASS
PASS
1.48
PASS
PASS
1.50
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
1.2513
1.2649
1.2501
1.2596
1.2532
1.2487
1.2455
1.2566
1.2485
1.2564
1.2703
1.2746
1.2741
1.2588
1.2740
1.2689
1.2447
1.2652
1.2691
1.2609
1.2923
1.2950
1.2904
1.2815
1.2880
1.2784
1.2747
1.2709
1.2825
1.2849
P a g e 25 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
VC Dropout Voltage (V) @ VIN = 1V,IL =2.8A
1.60
Specification MAX
1.50
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (+KTL) Biased
1.40
Average All GND'd
1.30
Ps90%/90% (-KTL) All GND'd
1.20
Average Biased
Ps90%/90% (-KTL) Biased
1.10
1.00
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.11: Plot of VCONTROL Dropout Voltage (@ IL = 2.8A) versus Total Dose
The average measured values of samples are within datasheet limits.
P a g e 26 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.11: Raw data table for VCONTROL dropout voltage (IL = 2.8A) versus total dose including
the statistical calculations, maximum specification, and the status of the test (PASS/FAIL)
Parameter
Units
6
7
8
9
10
1
2
3
4
5
16
17
18
19
20
11
12
13
14
15
26
27
28
29
30
21
22
23
24
25
36
37
38
39
40
31
32
33
34
35
46
47
48
49
50
41
42
43
44
45
51
52
VC Dropout @ VIN = 1V,IL =2.8A
(V)
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Control Unit
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
1.2678
1.2612
1.2624
1.2544
1.2519
1.2666
1.2586
1.2608
1.2629
1.2629
1.2498
1.2651
1.2563
1.2566
1.2554
1.2473
1.2440
1.2607
1.2464
1.2594
1.2531
1.2638
1.2616
1.2498
1.2611
1.2571
1.2594
1.2568
1.2571
1.2572
1.2601
1.2594
1.2489
1.2656
1.2541
1.2594
1.2583
1.2520
1.2539
1.2612
1.2495
1.2532
1.2441
1.2510
1.2572
1.2522
1.2610
1.2590
1.2526
1.2569
1.2577
1.2510
10
1.2739
1.4098
1.2709
1.2595
1.2549
1.2708
1.2652
1.2659
1.2727
1.2691
20
50
100
200
1.2577
1.2510
1.2577
1.2510
1.2577
1.2510
1.2577
1.2510
1.3186
1.3214
1.3211
1.3208
1.3252
1.3019
1.3076
1.3093
1.3052
1.3061
1.2577
1.2510
1.2595
0.0064
1.2771
1.2420
1.2938
0.0653
1.4729
1.1148
1.2671
0.0055
1.2821
1.2521
1.2796
0.0063
1.2968
1.2624
1.3449
0.0598
1.5089
1.1810
1.3214
0.0024
1.3280
1.3149
1.2623
0.0030
1.2705
1.2542
1.2687
0.0032
1.2775
1.2599
1.2625
0.0052
1.2767
1.2483
1.2749
0.0087
1.2987
1.2512
1.3138
0.0535
1.4606
1.1669
1.3060
0.0028
1.3137
1.2984
1.50
PASS
PASS
1.51
PASS
PASS
1.51
PASS
PASS
1.52
PASS
PASS
1.53
PASS
PASS
1.55
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
1.2633
1.2757
1.2641
1.2678
1.2644
1.2594
1.2574
1.2683
1.2595
1.2679
1.2792
1.2836
1.2825
1.2689
1.2839
1.2804
1.2599
1.2770
1.2812
1.2761
1.3000
1.3048
1.2991
1.4072
1.4135
1.2908
1.2867
1.2838
1.4090
1.2985
P a g e 27 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
VIN Dropout Voltage (V) @ VC =2V,IL =0.1A
0.0500
Specification MAX
0.0450
Ps90%/90% (+KTL) Biased
0.0400
Average Biased
0.0350
Ps90%/90% (-KTL) Biased
0.0300
Ps90%/90% (+KTL) All GND'd
0.0250
Average All GND'd
0.0200
Ps90%/90% (-KTL) All GND'd
0.0150
0.0100
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.12: Plot of VIN Dropout Voltage (@ IL = 0.1A) versus Total Dose
The measured data points are within datasheet specification maximum limits.
P a g e 28 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.12: Raw data table for VIN dropout voltage (IL = 0.1A) versus total dose including the
statistical calculations, maximum specification, and the status of the test (PASS/FAIL)
Parameter
Units
6
7
8
9
10
1
2
3
4
5
16
17
18
19
20
11
12
13
14
15
26
27
28
29
30
21
22
23
24
25
36
37
38
39
40
31
32
33
34
35
46
47
48
49
50
41
42
43
44
45
51
52
VIN Dropout @ VC =2V,IL =0.1A
(V)
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Control Unit
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
0.0167
0.0170
0.0169
0.0168
0.0166
0.0170
0.0169
0.0168
0.0169
0.0168
0.0167
0.0172
0.0165
0.0167
0.0167
0.0169
0.0164
0.0169
0.0168
0.0168
0.0168
0.0168
0.0171
0.0167
0.0166
0.0165
0.0170
0.0167
0.0166
0.0168
0.0168
0.0168
0.0164
0.0166
0.0164
0.0171
0.0166
0.0167
0.0169
0.0170
0.0163
0.0164
0.0164
0.0163
0.0165
0.0163
0.0166
0.0165
0.0166
0.0163
0.0166
0.0166
10
0.0173
0.0174
0.0174
0.0173
0.0171
0.0174
0.0174
0.0174
0.0175
0.0174
20
50
100
200
0.0166
0.0166
0.0166
0.0166
0.0166
0.0166
0.0166
0.0166
0.0202
0.0205
0.0208
0.0204
0.0206
0.0251
0.0259
0.0253
0.0253
0.0255
0.0166
0.0166
0.0168
0.0002
0.0173
0.0163
0.0173
0.0001
0.0177
0.0169
0.0175
0.0003
0.0183
0.0167
0.0186
0.0002
0.0192
0.0180
0.0193
0.0003
0.0200
0.0185
0.0205
0.0002
0.0211
0.0199
0.0169
0.0001
0.0171
0.0166
0.0174
0.0001
0.0176
0.0172
0.0179
0.0003
0.0187
0.0171
0.0190
0.0012
0.0224
0.0157
0.0218
0.0003
0.0226
0.0211
0.0254
0.0003
0.0263
0.0246
0.035
PASS
PASS
0.035
PASS
PASS
0.040
PASS
PASS
0.040
PASS
PASS
0.045
PASS
PASS
0.045
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
0.0174
0.0180
0.0173
0.0174
0.0174
0.0180
0.0174
0.0180
0.0180
0.0180
0.0186
0.0186
0.0189
0.0184
0.0184
0.0194
0.0169
0.0195
0.0194
0.0200
0.0194
0.0196
0.0192
0.0191
0.0189
0.0219
0.0217
0.0216
0.0217
0.0223
P a g e 29 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
VIN Dropout Voltage (V) @ VC =2V,IL =1A
0.240
Specification MAX
0.220
Ps90%/90% (+KTL) Biased
Average Biased
0.200
Ps90%/90% (+KTL) All GND'd
0.180
Ps90%/90% (-KTL) Biased
Average All GND'd
0.160
Ps90%/90% (-KTL) All GND'd
0.140
0.120
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.13: Plot of VIN Dropout Voltage (@ IL = 1A) versus Total Dose
The average measured values of samples are within datasheet specification maximum limits.
P a g e 30 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.13: Raw data table for VIN dropout voltage (IL = 1A) versus total dose including the
statistical calculations, maximum specification, and the status of the test (PASS/FAIL)
Parameter
Units
6
7
8
9
10
1
2
3
4
5
16
17
18
19
20
11
12
13
14
15
26
27
28
29
30
21
22
23
24
25
36
37
38
39
40
31
32
33
34
35
46
47
48
49
50
41
42
43
44
45
51
52
VIN Dropout @ VC =2V,IL =1A
(V)
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Control Unit
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
0.1427
0.1437
0.1438
0.1426
0.1402
0.1418
0.1423
0.1427
0.1435
0.1423
0.1425
0.1440
0.1404
0.1426
0.1396
0.1423
0.1397
0.1431
0.1438
0.1429
0.1402
0.1425
0.1440
0.1418
0.1413
0.1399
0.1423
0.1400
0.1385
0.1434
0.1412
0.1421
0.1413
0.1419
0.1406
0.1415
0.1395
0.1415
0.1423
0.1435
0.1411
0.1400
0.1415
0.1396
0.1414
0.1395
0.1429
0.1420
0.1409
0.1403
0.1422
0.1407
10
0.1442
0.1460
0.1456
0.1439
0.1417
0.1436
0.1435
0.1441
0.1454
0.1438
20
50
100
200
0.1422
0.1407
0.1422
0.1407
0.1422
0.1407
0.1422
0.1407
0.1488
0.1481
0.1499
0.1476
0.1496
0.1533
0.1576
0.1555
0.1542
0.1542
0.1422
0.1407
0.1426
0.0015
0.1467
0.1386
0.1443
0.0017
0.1489
0.1397
0.1438
0.0018
0.1487
0.1389
0.1449
0.0019
0.1500
0.1398
0.1463
0.0008
0.1486
0.1440
0.1488
0.0010
0.1515
0.1461
0.1425
0.0006
0.1443
0.1407
0.1441
0.0008
0.1462
0.1420
0.1447
0.0017
0.1495
0.1399
0.1434
0.0025
0.1502
0.1366
0.1489
0.0015
0.1529
0.1449
0.1549
0.0017
0.1595
0.1504
0.220
PASS
PASS
0.225
PASS
PASS
0.225
PASS
PASS
0.225
PASS
PASS
0.225
PASS
PASS
0.230
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
0.1445
0.1458
0.1423
0.1443
0.1421
0.1444
0.1419
0.1455
0.1465
0.1454
0.1423
0.1458
0.1473
0.1449
0.1440
0.1428
0.1408
0.1436
0.1423
0.1474
0.1457
0.1458
0.1458
0.1476
0.1466
0.1485
0.1471
0.1485
0.1493
0.1511
P a g e 31 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
VIN Dropout Voltage (V) @ VC =2V, IL =2.8A
0.70
Specification MAX
0.65
Ps90%/90% (+KTL) Biased
0.60
Ps90%/90% (+KTL) All GND'd
Average Biased
0.55
Average All GND'd
0.50
Ps90%/90% (-KTL) All GND'd
0.45
Ps90%/90% (-KTL) Biased
0.40
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.14: Plot of VIN Dropout Voltage (@ IL = 2.8A) versus Total Dose
The average measured values of samples are within datasheet specification maximum limits.
P a g e 32 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.14: Raw data table for VIN dropout voltage (IL = 2.8A) versus total dose including the
statistical calculations, maximum specification, and the status of the test (PASS/FAIL)
Parameter
Units
6
7
8
9
10
1
2
3
4
5
16
17
18
19
20
11
12
13
14
15
26
27
28
29
30
21
22
23
24
25
36
37
38
39
40
31
32
33
34
35
46
47
48
49
50
41
42
43
44
45
51
52
VIN Dropout @ VC =2V, IL =2.8A
(V)
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Control Unit
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
0.4433
0.4477
0.4490
0.4431
0.4327
0.4374
0.4401
0.4423
0.4471
0.4416
0.4443
0.4471
0.4356
0.4429
0.4281
0.4418
0.4321
0.4456
0.4500
0.4457
0.4309
0.4416
0.4476
0.4413
0.4376
0.4320
0.4410
0.4312
0.4243
0.4486
0.4358
0.4405
0.4390
0.4405
0.4364
0.4363
0.4297
0.4406
0.4425
0.4448
0.4397
0.4334
0.4394
0.4315
0.4389
0.4324
0.4467
0.4412
0.4373
0.4338
0.4425
0.4358
10
0.4454
0.4580
0.4519
0.4453
0.4355
0.4410
0.4415
0.4441
0.4502
0.4438
20
50
100
200
0.4425
0.4358
0.4425
0.4358
0.4425
0.4358
0.4425
0.4358
0.4520
0.4468
0.4525
0.4446
0.4523
0.4506
0.4683
0.4597
0.4547
0.4528
0.4425
0.4358
0.4432
0.0064
0.4607
0.4256
0.4472
0.0084
0.4703
0.4242
0.4428
0.0077
0.4640
0.4216
0.4445
0.0080
0.4663
0.4226
0.4464
0.0046
0.4591
0.4338
0.4496
0.0037
0.4598
0.4395
0.4417
0.0036
0.4515
0.4319
0.4441
0.0036
0.4541
0.4341
0.4461
0.0073
0.4660
0.4261
0.4366
0.0097
0.4633
0.4099
0.4471
0.0057
0.4626
0.4316
0.4572
0.0070
0.4765
0.4379
0.650
PASS
PASS
0.655
PASS
PASS
0.655
PASS
PASS
0.655
PASS
PASS
0.660
PASS
PASS
0.670
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
0.4473
0.4497
0.4388
0.4454
0.4327
0.4438
0.4347
0.4490
0.4539
0.4489
0.4323
0.4484
0.4533
0.4467
0.4416
0.4328
0.4358
0.4346
0.4268
0.4528
0.4418
0.4438
0.4440
0.4529
0.4496
0.4447
0.4388
0.4482
0.4501
0.4537
P a g e 33 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
VC Pin Current (mA) @ VIN =1V,VC =2V,IL =0.1A
12.00
Specification MAX
11.00
Ps90%/90% (+KTL) All GND'd
10.00
Ps90%/90% (+KTL) Biased
9.00
Average All GND'd
8.00
Average Biased
7.00
Ps90%/90% (-KTL) Biased
6.00
Ps90%/90% (-KTL) All GND'd
5.00
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.15: Plot of VCONTROL Pin Current (@ IL = 0.1A) versus Total Dose
The average measured values of samples are within datasheet specification maximum limits.
P a g e 34 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.15: Raw data table for VCONTROL pin current (IL = 0.1A) versus total dose including the
statistical calculations, maximum specification, and the status of the test (PASS/FAIL)
Parameter ICONT ROL @ VIN=1V,VC=2V,IL =0.1A
Units
(mA)
6
All GND'd Irradiation
7
All GND'd Irradiation
8
All GND'd Irradiation
9
All GND'd Irradiation
10
All GND'd Irradiation
1
Biased Irradiation
2
Biased Irradiation
3
Biased Irradiation
4
Biased Irradiation
5
Biased Irradiation
16
All GND'd Irradiation
17
All GND'd Irradiation
18
All GND'd Irradiation
19
All GND'd Irradiation
20
All GND'd Irradiation
11
Biased Irradiation
12
Biased Irradiation
13
Biased Irradiation
14
Biased Irradiation
15
Biased Irradiation
26
All GND'd Irradiation
27
All GND'd Irradiation
28
All GND'd Irradiation
29
All GND'd Irradiation
30
All GND'd Irradiation
21
Biased Irradiation
22
Biased Irradiation
23
Biased Irradiation
24
Biased Irradiation
25
Biased Irradiation
36
All GND'd Irradiation
37
All GND'd Irradiation
38
All GND'd Irradiation
39
All GND'd Irradiation
40
All GND'd Irradiation
31
Biased Irradiation
32
Biased Irradiation
33
Biased Irradiation
34
Biased Irradiation
35
Biased Irradiation
46
All GND'd Irradiation
47
All GND'd Irradiation
48
All GND'd Irradiation
49
All GND'd Irradiation
50
All GND'd Irradiation
41
Biased Irradiation
42
Biased Irradiation
43
Biased Irradiation
44
Biased Irradiation
45
Biased Irradiation
51
Control Unit
52
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
5.893
5.882
5.912
5.879
5.870
5.903
5.886
5.912
5.898
5.896
5.875
5.905
5.855
5.930
5.884
5.863
5.870
5.906
5.882
5.925
5.798
5.916
5.865
5.825
5.896
5.845
5.823
5.843
5.823
5.800
5.881
5.897
5.924
5.943
5.920
5.855
5.808
5.802
5.855
5.847
5.910
5.921
5.911
5.920
5.970
5.907
5.931
5.929
5.926
5.921
5.924
5.898
10
5.945
5.817
5.957
5.920
5.918
5.956
5.946
5.968
5.960
5.947
20
50
100
200
5.924
5.898
5.924
5.898
5.924
5.898
5.924
5.898
5.560
5.533
5.489
5.524
5.584
5.581
5.533
5.614
5.618
5.575
5.924
5.898
5.887
0.016
5.931
5.844
5.911
0.055
6.063
5.760
5.909
0.029
5.988
5.830
5.805
0.042
5.921
5.689
5.846
0.153
6.266
5.427
5.538
0.036
5.637
5.439
5.899
0.009
5.925
5.873
5.955
0.009
5.981
5.930
5.914
0.028
5.991
5.838
5.831
0.099
6.104
5.559
5.741
0.132
6.102
5.380
5.584
0.034
5.679
5.490
10.0
PASS
PASS
10.1
PASS
PASS
10.1
PASS
PASS
10.2
PASS
PASS
10.5
PASS
PASS
11.0
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
5.898
5.923
5.875
5.946
5.907
5.890
5.885
5.937
5.912
5.948
5.762
5.852
5.807
5.763
5.841
5.812
6.003
5.804
5.792
5.745
5.728
5.732
5.744
6.015
6.013
5.727
5.635
5.674
5.968
5.701
P a g e 35 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
VC Pin Current (mA) @ VIN 1V,VC =2V,IL =1A
50.00
45.00
Specification MAX
40.00
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (+KTL) Biased
35.00
Average All GND'd
30.00
Average Biased
25.00
Ps90%/90% (-KTL) Biased
20.00
Ps90%/90% (-KTL) All GND'd
15.00
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.16: Plot of VCONTROL Pin Current (@ IL = 1A) versus Total Dose
The average measured values of samples are within datasheet specification maximum limits.
P a g e 36 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.16: Raw data table for VCONTROL pin current (IL = 1A) versus total dose including the
statistical calculations, maximum specification, and the status of the test (PASS/FAIL)
Parameter
Units
6
7
8
9
10
1
2
3
4
5
16
17
18
19
20
11
12
13
14
15
26
27
28
29
30
21
22
23
24
25
36
37
38
39
40
31
32
33
34
35
46
47
48
49
50
41
42
43
44
45
51
52
ICONT ROL @ VIN=1V,VC =2V,IL =1A
(mA)
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Control Unit
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
18.958
18.917
18.992
18.940
18.916
19.015
18.910
19.008
18.944
18.952
18.908
18.976
18.798
19.000
18.933
18.874
18.917
18.966
18.963
19.023
18.680
19.046
18.924
18.768
18.954
18.807
18.756
18.816
18.746
18.691
18.893
18.970
19.055
19.109
19.035
18.827
18.725
18.701
18.792
18.824
18.997
19.008
19.095
19.019
19.163
19.001
19.049
19.049
19.029
19.029
19.034
18.987
10
19.196
19.910
19.220
19.119
19.124
19.195
19.214
19.254
19.258
19.173
20
50
100
200
19.034
18.987
19.034
18.987
19.034
18.987
19.034
18.987
18.499
18.453
18.522
18.483
18.595
18.505
18.402
18.618
18.631
18.528
19.034
18.987
18.944
0.032
19.031
18.858
19.314
0.336
20.236
18.392
19.125
0.079
19.341
18.909
19.130
0.115
19.446
18.814
19.371
0.344
20.314
18.428
18.510
0.053
18.657
18.364
18.966
0.045
19.089
18.843
19.219
0.037
19.321
19.117
19.192
0.033
19.283
19.101
19.318
0.188
19.833
18.804
19.104
0.492
20.452
17.757
18.537
0.093
18.792
18.281
35
PASS
PASS
36
PASS
PASS
37
PASS
PASS
38
PASS
PASS
40
PASS
PASS
45
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
19.151
19.178
19.025
19.246
19.024
19.168
19.153
19.190
19.235
19.213
19.115
19.143
19.189
18.948
19.257
19.398
19.593
19.257
19.249
19.094
18.976
19.210
19.203
19.758
19.707
18.977
18.813
18.839
19.976
18.917
P a g e 37 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
VC Pin Current (mA) @ VIN =1V, VC =2V, IL = 2.8A
110.00
100.00
Specification MAX
Ps90%/90% (+KTL) All GND'd
90.00
Ps90%/90% (+KTL) Biased
80.00
Average All GND'd
70.00
Average Biased
60.00
Ps90%/90% (-KTL) Biased
50.00
Ps90%/90% (-KTL) All GND'd
40.00
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.17: Plot of VCONTROL Pin Current (@ IL = 2.8A) versus Total Dose
The average measured values of samples are within datasheet specification maximum limits.
P a g e 38 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.17: Raw data table for VCONTROL pin current (IL = 2.8A) versus total dose including the
statistical calculations, minimum specification, and the status of the test (PASS/FAIL)
Parameter ICONT ROL @ VIN=1V,VC =2V,IL =2.8A
Units
(mA)
6
All GND'd Irradiation
7
All GND'd Irradiation
8
All GND'd Irradiation
9
All GND'd Irradiation
10
All GND'd Irradiation
1
Biased Irradiation
2
Biased Irradiation
3
Biased Irradiation
4
Biased Irradiation
5
Biased Irradiation
16
All GND'd Irradiation
17
All GND'd Irradiation
18
All GND'd Irradiation
19
All GND'd Irradiation
20
All GND'd Irradiation
11
Biased Irradiation
12
Biased Irradiation
13
Biased Irradiation
14
Biased Irradiation
15
Biased Irradiation
26
All GND'd Irradiation
27
All GND'd Irradiation
28
All GND'd Irradiation
29
All GND'd Irradiation
30
All GND'd Irradiation
21
Biased Irradiation
22
Biased Irradiation
23
Biased Irradiation
24
Biased Irradiation
25
Biased Irradiation
36
All GND'd Irradiation
37
All GND'd Irradiation
38
All GND'd Irradiation
39
All GND'd Irradiation
40
All GND'd Irradiation
31
Biased Irradiation
32
Biased Irradiation
33
Biased Irradiation
34
Biased Irradiation
35
Biased Irradiation
46
All GND'd Irradiation
47
All GND'd Irradiation
48
All GND'd Irradiation
49
All GND'd Irradiation
50
All GND'd Irradiation
41
Biased Irradiation
42
Biased Irradiation
43
Biased Irradiation
44
Biased Irradiation
45
Biased Irradiation
51
Control Unit
52
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
44.716
44.578
44.733
44.703
44.680
44.812
44.544
44.698
44.592
44.607
44.678
44.874
44.183
44.763
44.547
44.592
44.537
44.699
44.871
44.897
44.063
44.850
44.695
44.258
44.592
44.317
44.240
44.340
44.099
44.250
44.525
44.649
44.793
45.019
44.597
44.387
44.115
44.073
44.314
44.321
44.704
44.678
45.030
44.797
45.135
44.638
44.983
44.850
44.802
44.740
44.766
44.685
10
45.643
47.099
45.620
45.476
45.552
45.601
45.573
45.601
45.681
45.469
20
50
100
200
44.766
44.685
44.766
44.685
44.766
44.685
44.766
44.685
44.744
44.621
45.020
44.809
45.016
44.659
44.773
44.982
44.963
44.721
44.766
44.685
44.682
0.061
44.850
44.513
45.878
0.685
47.757
43.999
45.508
0.267
46.239
44.777
45.660
0.250
46.346
44.973
46.157
0.657
47.959
44.355
44.842
0.174
45.320
44.364
44.650
0.106
44.941
44.360
45.585
0.076
45.795
45.375
45.689
0.178
46.176
45.202
45.984
0.303
46.816
45.153
45.777
1.210
49.096
42.458
44.819
0.145
45.218
44.420
80
PASS
PASS
82
PASS
PASS
83
PASS
PASS
85
PASS
PASS
90
PASS
PASS
100
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
45.713
45.755
45.147
45.711
45.215
45.637
45.468
45.624
45.940
45.777
45.583
45.689
45.900
45.274
45.853
46.185
46.414
45.836
45.793
45.694
45.469
45.970
45.956
46.146
47.243
45.443
45.106
45.126
47.928
45.280
P a g e 39 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Current Limit (A) @ VIN = VC = 5V, VOUT = - 0.1V
3.25
Ps90%/90% (+KTL) All GND'd
3.20
3.15
Ps90%/90% (+KTL) Biased
3.10
Average All GND'd
3.05
3.00
Average Biased
2.95
Ps90%/90% (-KTL) Biased
2.90
Ps90%/90% (-KTL) All GND'd
2.85
Specification MIN
2.80
2.75
0
50
100
150
200
250
Total Dose (Krad(Si))
Figure 5.18: Plot of Current Limit versus Total Dose
The average measured values of samples passed datasheet specification minimum limits.
P a g e 40 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table 5.18: Raw data table for current limit versus total dose including the statistical
calculations, minimum specification, and the status of the test (PASS/FAIL)
Parameter
Units
6
7
8
9
10
1
2
3
4
5
16
17
18
19
20
11
12
13
14
15
26
27
28
29
30
21
22
23
24
25
36
37
38
39
40
31
32
33
34
35
46
47
48
49
50
41
42
43
44
45
51
52
ILIM IT @ VIN=VC=5V,VOUT =-0.1V
(A)
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
All GND'd Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Biased Irradiation
Control Unit
Control Unit
All GND'd Irradiation Statistics
Average All GND'd
Std Dev All GND'd
Ps90%/90% (+KTL) All GND'd
Ps90%/90% (-KTL) All GND'd
Biased Irradiation Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Specification MIN
Status (Measurements) All GND'd
Status (Measurements) Biased
Specification MAX
Status (Measurements) All GND'd
Status (Measurements) Biased
Total Dose (Krad(Si)) @ 50 rads(Si)/s
0
3.029
3.055
3.078
3.018
2.989
3.045
3.031
3.073
3.049
3.037
3.047
3.041
3.005
3.041
3.046
3.021
3.034
3.028
3.047
3.042
3.022
3.036
3.005
2.993
3.018
2.993
3.011
2.991
3.014
2.972
3.034
3.060
3.069
3.004
3.074
3.025
2.997
3.001
3.034
3.054
3.018
3.018
3.025
2.993
3.092
3.026
3.006
3.031
3.037
3.006
3.037
3.030
10
3.044
3.078
3.103
3.040
3.012
3.064
3.055
3.093
3.070
3.059
20
50
100
200
3.037
3.030
3.037
3.030
3.037
3.030
3.037
3.030
3.091
3.086
3.104
3.064
3.160
3.094
3.076
3.092
3.101
3.073
3.037
3.030
3.034
0.034
3.128
2.939
3.056
0.035
3.153
2.958
3.059
0.018
3.107
3.011
3.069
0.015
3.110
3.028
3.108
0.029
3.188
3.028
3.101
0.036
3.199
3.003
3.047
0.016
3.091
3.003
2.8
PASS
PASS
3.068
0.015
3.109
3.028
2.8
PASS
PASS
3.058
0.009
3.083
3.034
2.8
PASS
PASS
3.052
0.019
3.105
2.999
2.8
PASS
PASS
3.081
0.024
3.146
3.016
2.8
PASS
PASS
3.087
0.012
3.121
3.054
2.8
PASS
PASS
Status (-KTL) All GND'd
Status (+KTL) All GND'd
PASS
PASS
PASS
PASS
PASS
PASS
Status (-KTL) Biased
Status (+KTL) Biased
PASS
PASS
PASS
PASS
PASS
PASS
3.070
3.064
3.035
3.066
3.059
3.054
3.052
3.050
3.069
3.066
3.081
3.085
3.066
3.046
3.067
3.049
3.072
3.043
3.069
3.026
3.087
3.114
3.141
3.070
3.129
3.081
3.053
3.063
3.099
3.109
P a g e 41 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Appendix A
Picture of one among ten samples used in the test. The part type is in development and
identification numbers will be marked on top of future devices.
Figure A1: Top View showing serial number
Figure A2: Bottom View
P a g e 42 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Appendix B
Radiation Bias Connection Tables
Table B1: Biased Conditions
PIN
1
2
3
4
FUNCTION
NC
SET
VCONTROL
IN
CASE
OUT
CONNECTION / BIAS
NC
To ground via 10KΩ resistor
To pin 4
To +3V
To ground via 1uF
To pin 3
To ground via 100Ω resistor
To ground via 10uF capacitor
Table B2: All GND’d
PIN
1
2
3
4
CASE
FUNCTION
NC
SET
VCONTROL
IN
OUT
CONNECTION / BIAS
Ground
Ground
Ground
Ground
Ground
P a g e 43 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Figure B1: Total Dose Bias Circuit
Figure B2: Pin-Out
P a g e 44 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Figure B3: Bias Board (top view)
Figure B4: Bias Board (bottom view)
P a g e 45 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Appendix C
P a g e 46 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
P a g e 47 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
P a g e 48 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Appendix D
Table D1: Pre-Irradiation Electrical Characteristics of Device-Under-Test
P a g e 49 | 50
LINEAR TECHNOLOGY CORPORATION
TID HDR RH3083MK HP201682 W1
Table D2: Post-Irradiation Electrical Characteristics of Device-Under-Test
P a g e 50 | 50
LINEAR TECHNOLOGY CORPORATION