HRS IT3D-300S-BGA

1/6
TR0636E-20027
IT3D(M)-300S-BGA (57) BGA Shearing Force
TEST REPORT
APPROVED
TY. ARAI
CHECKED
TM.MATSUO
PREPARED
TY.TAKADA
HIROSE ELECTRIC CO., LTD.
2/6
[1] Objective
To evaluate BGA shearing force by comparing Initial state and Post 3500 thermal
cycle in accordance with IPC-9701.
[2] Specimens
Type
Product
Assembly
State
# of specimens
Type_1
IT3D-300S-BGA (57)
Virgin
Initial
3
Type_2
IT3D-300S-BGA (57)
Reworked
Initial
3
Type_3
IT3D-300S-BGA (57)
Virgin
Post
3
3500 cycles
Type_4
IT3D-300S-BGA (57)
Reworked
Post
3500 cycles
Remarks
*Type_3, Type_4 are assembled as Fig.1.
*The test board design is based on IPC-9701
specification.
*Thickness of the PCB: 3.3mm
Fig.1
[3] Test period
From:
To
2007-09-12
:
2008-01-18
[4] Test Equipment
Test equipment
Model
Manufacture
Insertion and withdrawal force tester
AG-IS
Shimazu
3
3/6
BGA shearing force
1.
Requirements
The failure mode for the sheared balls shall be either bulk solder failure or copper
pad lift-off.
Intermetallic failure is unacceptable.
2.
Conditions
2-1 Test Condition
0
(+10 / 0 C )
( 0 / -100C )
Test cycle : 3500 cycles
2-2 BGA Shearing Force
IT3D-300S-BGA(57)
Insertion and withdrawal force tester
CONNECTOR Sample
* Speed: 500 micrometer /second
0.3mm space
Test PCB
4/6
4.
Results
4-1
BGA Shearing Force
UNIT: KN
No.
Type-1
State
Type-2
Initial
Type-3
Type-4
Post 3500 thermal cycles
Assembly
Virgin
Reworked
Virgin
Reworked
1
1.22
1.18
1.21
1.13
2
1.18
1.16
1.13
0.91
3
1.25
1.18
1.13
1.11
MAX
1.25
1.18
1.21
1.13
MIN
1.18
1.16
1.13
0.91
AVG
1.22
1.17
1.16
1.05
4-2
Failure Mode
No intermetallic failure was found in all specimens.
Copper pad lift-off was found in the sheared area.
Details are shown in the following pages.
5/6
Type-1 (Initial)
Virgin
Copper Pad lift-off
Type-2 (Initial)
Reworked
Copper Pad lift-off
6/6
Type-3 (Post 3500 thermal cycles)
Virgin
Copper Pad lift-off
Type-4 (Post 3500 thermal cycles)
Reworked
Copper Pad lift-off