SSDI SDAD103H7.5UF

SDAD103 UF Series
Solid State Devices, Inc.
14701 Firestone Blvd * La Mirada, CA 90638
Phone: (562) 404-4474 * Fax: (562) 404-1773
[email protected] * www.ssdi-power.com
2,500 to 15,000 VOLTS
ULTRA FAST RECOVERY
STACKABLE HIGH VOLTAGE RECTIFIER
Designer’s Data Sheet
Part Number/Ordering Information 1/
SDAD10 3 __ __ __ __
└ Screening 2/
│ │
│ │
FEATURES:
 Stackable to 600 kV+
 PIV 2.5kV to 15kV
 High Current Ratings
 Ultra Fast Reverse Recovery Time
 Only Hermetically Sealed Rectifiers Used
 Controlled Avalanche Rated
 Modular Design for Easy Stacking
 Storage and Operating Temps -65°C to +150°C
 Available in Fast and Hyper Fast Versions
 TX, TXV, and S-Level Screening Available 2/
__ = Not Screened
│ │
│ │
TX = TX Level
│
│
│ │
TXV = TXV Level
│
│
│
S = S Level
│ │
│
│
│ │
└
Reverse
Recovery Time
│
│ │
UF
=
Ultra
Fast Recovery Time
│
│ │
Voltage
2.5
=
2.5kV, 5 = 5kV,
└
│
7.5 = 7.5kV, 10 = 10kV, and
│
│
15 = 15kV
│ └
Power Rating (See Below)
│
Package
Size = 3 Inches Diameter
└
ELECTRICAL CHARACTERISTICS 3/
Part Number
SDAD103 H 2.5 UF
SDAD103 H 5.0 UF
SDAD103 H 7.5 UF
SDAD103 H 10 UF
SDAD103 H 15 UF
Peak Inverse
Voltage
Reverse
Recovery
Time 5/
Average DC Output Current 4/
Tc = Case Temperature
Surge
Nonrepetitive
PIV (KV)
Max (ns)
If(avg)
Ifsm
25 C
2.5
5.0
7.5
10
15
25 C
70
70
70
70
70
75 C
9.00
6.75
4.50
3.15
2.14
50 C
14.4
10.8
7.20
4.50
3.00
60 C
11.2
8.46
5.58
4.00
2.65
100 C
200
200
200
125
125
Maximum Forward
Voltage Drop
Vf (V)
Maximum
Leakage
Current @PIV
If (A)
Ir (uA)
25 C
3.90
7.20
7.60
5.40
10.10
3.60
13.85
2.25
19.2
1.44
25 C
30
30
20
10
10
SDAD103 Package:
NOTES:
1/ For ordering information, price, curves, and availability- contact
factory.
2/ Screening based on MIL-PRF-19500. Screening flows available on
request.
3/ Unless Otherwise Specified, All Electrical Characteristics @25ºC.
4/ Tc = 50 ºC typical operation in oil.
Tc = 75 ºC is typical ambient Ta = 25 ºC unheatsunk.
Tc = 60 ºC typical operation with extender plates in air.
5/ Recovery Conditions: IF = 0.5 Amp, IR = 1.0 Amp rec. to .25 Amp.
NOTE: All specifications are subject to change without notification.
SCD's for these devices should be reviewed by SSDI prior to release.
DATA SHEET #: RA0084B
DOC