LINEAGEPOWER JRW040A0A1

Data Sheet
July 21, 2008
JRW017/040/060/065/070 Series Power Modules;DC-DC Converter
36- 75Vdc Input, 1.2Vdc to 12Vdc Output;17A/40A/60A/65A/70A
RoHS Compliant
Features
ƒ
Compliant to RoHS EU Directive 2002/95/EC (-Z
versions)
ƒ
Compliant to ROHS EU Directive 2002/95/EC with
lead solder exemption (non-Z versions)
ƒ
Delivers up to 70A Output current
ƒ
High efficiency – 91% at 3.3V full load
ƒ
Improved Thermal Performance:
42A at 70ºC at 1m/s (200LFM) for 3.3Vo
Applications
ƒ
Low output voltage-supports migration to future IC
supply voltages down to 1.0V
ƒ
Industry standard Half brick footprint
61.0mm x 58.4mm x 9.5mm
(2.40in x 2.30in x 0.38in)
ƒ
Distributed power architectures
ƒ
Wireless Networks
ƒ
High power density and Low output ripple and noise
ƒ
Optical and Access Network Equipment
ƒ
2:1 Input voltage range
ƒ
Enterprise Networks
ƒ
Constant switching frequency
ƒ
Latest generation IC’s (DSP, FPGA, ASIC)
and Microprocessor powered applications
ƒ
Output overcurrent/voltage/Overtemperature
protection
ƒ
Single Tightly regulated output
ƒ
Remote sense
Options
ƒ
Auto restart after fault protection shutdown
ƒ
Adjustable output voltage (+10%/ -20%)
ƒ
Positive logic, Remote On/Off
ƒ
Negative logic, Remote On/Off
ƒ
Case ground pin (-H Baseplate option)
ƒ
Wide operating temperature range (-40°C to 85°C)
ƒ
Active load sharing (Parallel Operation)
ƒ
Meets the voltage insulation requirements for ETSI
300-132-2 and complies with and is Licensed for
Basic Insulation rating per EN 60950
ƒ
CE mark meets 73/23/EEC and 93/68/EEC
directives§
ƒ
UL* 60950-1Recognized, CSA† C22.2 No. 60950-1‡
03 Certified, and VDE 0805:2001-12 (EN60950-1)
Licensed
ƒ
ISO** 9001 certified manufacturing facilities
Description
The JRW series provide up to 70A output current in an industry standard half brick, which makes it an ideal choice
for optimum space, high current and low voltage applications. The converter incorporates synchronous rectification
technology and innovative packaging techniques to achieve high efficiency reaching 91% at 3.3V full load. The ultra
high efficiency of this converter leads to lower power dissipation such that for most applications a heat sink is not
required. The output is fully isolated from the input, allowing versatile polarity configurations and grounding
connections. Built-in filtering for both input and output minimizes the need for external filtering.
* UL is a registered trademark of Underwriters Laboratories, Inc.
†
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
‡
Document No: DS03-120 ver 1.23
PDF name: jrw017-070a_series.ds.pdf
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
All
VIN
-0.3
80
Vdc
Input Voltage
Continuous
Transient (100 ms)
VIN, trans
-0.3
100
Vdc
All
TA
-40
85
°C
Storage Temperature
All
Tstg
-55
125
°C
I/O Isolation
All
1500
Vdc
Operating Ambient Temperature
(see Thermal Considerations section)
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
All
VIN
36
48
75
Vdc
All
IIN,max
7
Adc
Inrush Transient
All
It
2
1
As
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN=0V
to 75V, IO= IOmax ; see Figure 31)
All
-
mAp-p
Input Ripple Rejection (120Hz)
All
Operating Input Voltage
Maximum Input Current
(VIN=0 to 75V , IO=IO, max )
-
15
60
2
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included;
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a time-delay fuse with a maximum rating of 20A (see Safety Considerations section). Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE POWER
2
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Electrical Specifications (continued)
Parameter
Output Voltage Set-point
(VIN=VIN,nom, IO=IO, max, Tref=25°C)
Device
Symbol
Min
Typ
Max
P
VO, set
1.18
1.20
1.22
Vdc
M
1.47
1.50
1.52
Vdc
Y
1.77
1.80
1.83
Vdc
G
2.47
2.50
2.53
Vdc
F
3.24
3.30
3.36
Vdc
A
4.95
5.0
5.05
Vdc
11.76
12.0
12.24
Vdc
1.16
⎯
1.24
Vdc
Vdc
B
Output Voltage
(Over all operating input voltage,
resistive load, and temperature
conditions until end of life)
Unit
P
VO
⎯
M
1.45
1.55
Y
1.75
⎯
1.85
Vdc
G
2.42
⎯
2.58
Vdc
F
3.20
3.40
Vdc
A
4.85
⎯
⎯
5.15
Vdc
B
11.64
⎯
12.36
Vdc
Output Regulation
Line (VIN = VIN, min to VIN, max)
⎯
0.05
0.2
% VO, nom
Load (IO = IO, min to IO, max)
⎯
0.05
0.2
% VO, nom
Temperature (TA=-40ºC to +85ºC)
⎯
15
50
mV
RMS (5Hz to 20MHz bandwidth)
⎯
⎯
40
mVrms
Peak-to-Peak (5Hz to 20MHz
bandwidth)
⎯
⎯
100
mVpk-pk
⎯
⎯
30,000
μF
A,B
COut,ext
COut,ext
⎯
⎯
10,000
μF
P,M
Io
⎯
70
A
G,Y
0
0
⎯
65
A
F
0
⎯
60
A
A
0
⎯
40
A
B
0
⎯
17
A
Output Ripple and Noise on nominal
output
(VIN =VIN, nom and IO = IO, min to IO, max,
Cout = 1μF ceramic // 10μF Tantalum
capacitor)
External Capacitance
Output Current
Output Current Limit Inception
Output Short-Circuit Current
P,M,Y,G,F
⎯
80
⎯
A
G,Y
F
⎯
⎯
73
64
⎯
⎯
A
A
A
⎯
50
⎯
A
B
⎯
21
⎯
A
⎯
Latchedoff
P,M
All
IO, cli
o
VO ≤ 250 mV @ 25 C
LINEAGE POWER
3
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Electrical Specifications (continued)
Parameter
Efficiency
(VIN=VIN,nom, IO=IO, max, VO= VO,set TA=25°C)
Device
P
Symbol
η
Min
⎯
⎯
M
Typ
Max
84
⎯
%
⎯
%
86
Unit
Y
⎯
87
⎯
%
G
⎯
90
⎯
%
F
91
92
⎯
⎯
%
A
⎯
⎯
B
⎯
92
⎯
%
fsw
⎯
300
⎯
kHz
Vpk
⎯
6
⎯
%VO, set
ts
⎯
300
⎯
μs
Vpk
⎯
4
⎯
%VO, set
ts
⎯
300
⎯
μs
Vpk
⎯
3
⎯
%VO, set
ts
⎯
500
⎯
μs
%VO, set
Switching Frequency
%
Dynamic Load Response
(ΔIo/Δt=1A/10μs; Vin=Vin,nom; TA=25°C;
Tested with a 10 μF aluminum and a 1.0
μF tantalum capacitor across the load.)
Load Change from Io= 50% to 75% of
Io,max:
Peak Deviation
P,M,Y,G
Settling Time (Vo<10% peak deviation)
F,A
B
Load Change from Io= 75% to 50% of
Io,max:
Peak Deviation
P,M,Y,G
Settling Time (Vo<10% peak deviation)
F,A
B
Vpk
⎯
6
⎯
ts
⎯
300
⎯
μs
Vpk
⎯
4
⎯
%VO, set
ts
⎯
300
⎯
μs
Vpk
⎯
3
⎯
%VO, set
ts
⎯
500
⎯
μs
Isolation Specifications
Symbol
Min
Typ
Max
Unit
Isolation Capacitance
Parameter
CISO
⎯
2700
⎯
pF
Isolation Resistance
RISO
10
⎯
⎯
MΩ
General Specifications
Parameter
Min
Calculated MTBF (IO= 80% of IO, max, TA=40°C, airflow=1m/s (400LFM)
Weight
LINEAGE POWER
Typ
Max
1,363,000
⎯
60.3 (2.1)
Unit
Hours
⎯
g (oz.)
4
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
All
Ion/Off
―
0.15
1.0
mA
Logic Low
All
―
1.2
V
All
Von/Off
Von/Off
0.0
Logic High (Typ=Open Collector)
―
―
15
V
Logic High maximum allowable leakage current
All
Ion/Off
―
―
50
μA
Tdelay = Time until VO = 10% of VO,set from either
P
Tdelay
M
―
―
2
application of Vin with Remote On/Off set to On or
2
―
―
msec
operation of Remote On/Off from Off to On with Vin
already applied for at least one second.
Y
G
F
―
2
5
2
―
―
―
―
―
msec
msec
msec
A
―
2.5
―
msec
B
―
2.5
―
msec
―
Remote On/Off Signal interface
(VI = VI,min to VI, max; Open collector or equivalent
Compatible, signal referenced to VI (-) terminal)
Negative Logic: device code suffix “1”
Logic Low=module On, Logic High=Module Off
Positive Logic: No device code suffix required
Logic Low=module Off, Logic High=Module On
Logic Low Specification
Remote On/Off Current-Logic Low
On/Off Voltage:
Turn-On Delay and Rise Times
(IO=IO, max)
Trise = time for VO to rise from 10% of VO,set to 90%
of VO,set.
1
―
msec
M
―
1
―
msec
Y
―
1
―
msec
G
―
3
―
msec
F
―
1
―
msec
A
―
1
―
msec
B
―
1
―
msec
―
―
10
% VO, nom
80
―
110
% VO, nom
1.4
―
1.6
Vdc
M
1.8
―
2.2
Vdc
Y
2.3
―
2.6
Vdc
G
2.9
―
3.4
Vdc
F
3.8
―
4.6
Vdc
A
5.7
―
6.5
Vdc
B
14
―
16
Vdc
⎯
127
⎯
°C
⎯
30
34.5
32.5
36
V
⎯
V
P
Trise
msec
Output voltage adjustment range (TRIM)
Output Voltage Remote sense range
Vsense
Output Voltage Set-point Adjustment range
Output Over voltage protection
Over temperature Protection
Input Undervoltage Lockout
Turn-on Threshold
Turn-off Threshold
LINEAGE POWER
P
All
VOovsd
Tref
Vin, OVLO
5
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Characteristic Curves
Io = 8.5 A
INPUT CURRENT,(A)
5
Io = 0 A
4
3
2
1
0
25
35
45
55
65
75
VO (V) (5V/div)
Io = 17 A
6
VOn/off (V) (5V/div)
7
ON/OFF VOLTAGE OUTPUT VOLTAGE
The following figures provide typical characteristics for the JRW017A0B1 (12V, 17A) at 25ºC. The figures are
identical for either positive or negative Remote On/Off logic.
INPUT VOLTAGE, VIN (V)
TIME, t (1 ms/div)
Figure 1. Typical Start-Up (Input Current)
characteristics at room temperature.
Figure 4. Typical Start-Up Characteristics from Remote
ON/OFF.
90
EFFICIENCY (%)
85
V i = 36 V
80
V i = 48 V
75
V i = 75 V
70
0
3
6
9
12
15
18
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (200mV/div)
IO, (A) (4A/div)
95
TIME, t (100μs/div)
OUTPUT CURRENT, Io (A)
OUTPUT VOLTAGE
VO (V) (20mV/div)
36 Vin
48 Vin
75 Vin
TIME, t (1μs/div)
Figure 3. Typical Output Ripple and Noise at Room
temperature and Io = Io,max.
LINEAGE POWER
Figure 5. Transient Response to Dynamic Load Change
from 50% to 25% of full load current.
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (200mV/div)
IO, (A) (4A/div)
Figure 2. Converter Efficiency Vs Load at Room
temperature.
TIME, t (100μs/div)
Figure 6. Transient Response to Dynamic Load Change
from 50% to 75 % of full load current.
6
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Characteristic Curves (continued)
Io = 20 A
INPUT CURRENT,(A)
5
Io = 0 A
4
3
2
1
0
25
35
45
55
65
75
VO (V) (2V/div)
Io = 40 A
6
VOn/off (V) (5V/div)
7
ON/OFF VOLTAGE OUTPUT VOLTAGE
The following figures provide typical characteristics for the JRW040A0A (5V, 40A) at 25ºC. The figures are identical
for either positive or negative Remote On/Off logic.
INPUT VOLTAGE, VIN (V)
TIME, t (1 ms/div)
Figure 7. Typical Start-Up (Input Current)
characteristics at room temperature.
Figure 10. Typical Start-Up Characteristics from
Remote ON/OFF.
EFFICIENCY (%)
90
85
V i = 36 V
80
V i = 48 V
75
V i = 75 V
70
0
10
20
30
40
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (200mV/div)
IO, (A) (10A/div)
95
TIME, t (100μs/div)
OUTPUT CURRENT, Io (A)
OUTPUT VOLTAGE
VO (V) (50mV/div)
36 Vin
48 Vin
75 Vin
TIME, t (1μs/div)
Figure 9. Typical Output Ripple and Noise at Room
temperature and Io = Io,max.
LINEAGE POWER
Figure 11. Transient Response to Dynamic Load
Change from 50% to 25% of full load current.
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (200mV/div)
IO, (A) (10A/div)
Figure 8. Converter Efficiency Vs Load at Room
temperature.
TIME, t (100μs/div)
Figure 12. Transient Response to Dynamic Load
Change from 25% to 50 % of full load current.
7
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Characteristic Curves (continued)
The following figures provide typical characteristics for the JRW060A0F (3.3V, 60A)at 25ºC. The figures are identical
for either positive or negative Remote On/Off logic.
INPUT CURRENT,(A)
Io = 30 A
5
Io = 0 A
4
3
2
1
0
25
35
45
55
65
75
VO (V) (1V/div)
Io = 60 A
VOn/off (V) (5V/div)
7
6
ON/OFF VOLTAGE OUTPUT VOLTAGE
8
INPUT VOLTAGE, VIN (V)
TIME, t (0.5ms/div)
Figure 13. Typical Start-Up (Input Current)
characteristics at room temperature.
Figure 16. Typical Start-Up Characteristics from
Remote ON/OFF.
90
EFFICIENCY (%)
85
V i = 36 V
80
V i = 48 V
75
V i = 75 V
70
0
10
20
30
40
50
60
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (100mV/div)
IO, (A) (10A/div)
95
TIME, t (100μs/div)
OUTPUT CURRENT, Io (A)
OUTPUT VOLTAGE
VO (V) (10mV/div)
36 Vin
48 Vin
75 Vin
TIME, t (1μs/div)
Figure 15. Typical Output Ripple and Noise at Room
temperature and Io = Io,max.
LINEAGE POWER
Figure 17. Transient Response to Dynamic Load
Change from 50% to 25% of full load current.
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (100mV/div)
IO, (A) (10A/div)
Figure 14. Converter Efficiency Vs Load at Room
temperature.
TIME, t (100μs/div)
Figure 18. Transient Response to Dynamic Load
Change from 50% to 75 % of full load current.
8
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Characteristic Curves (continued)
INPUT CURRENT,(A)
Io = 32.5 A
4
Io = 0 A
3
2
1
0
25
35
45
55
65
75
VO (V) (1V/div)
Io = 65 A
5
VOn/off (V) (10V/div)
6
ON/OFF VOLTAGE OUTPUT VOLTAGE
The following figures provide typical characteristics for the JRW065A0G (2.5V, 65A)at 25ºC. The figures are identical
for either positive or negative Remote On/Off logic.
INPUT VOLTAGE, VIN (V)
TIME, t (2ms/div)
Figure 19. Typical Start-Up (Input Current)
characteristics at room temperature.
Figure 22. Typical Start-Up Characteristics from
Remote ON/OFF.
90
EFFICIENCY (%)
85
V i = 36 V
80
V i = 48 V
75
V i = 75 V
70
0
10
20
30
40
50
60
70
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (100mV/div)
IO, (A) (10A/div)
95
TIME, t (100μs/div)
OUTPUT CURRENT, Io (A)
OUTPUT VOLTAGE
VO (V) (20mV/div)
36 Vin
48 Vin
75 Vin
TIME, t (2.5μs/div)
Figure 21. Typical Output Ripple and Noise at Room
temperature and Io = Io,max.
LINEAGE POWER
Figure 23. Transient Response to Dynamic Load
Change from 50% to 25% of full load current.
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (100mV/div)
IO, (A) (10A/div)
Figure 20. Converter Efficiency Vs Load at Room
temperature.
TIME, t (100μs/div)
Figure 24. Transient Response to Dynamic Load
Change from 25% to 50 % of full load current.
9
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Characteristic Curves (continued)
The following figures provide typical characteristics for the JRW065A0Y (1.8V, 65A) at 25ºC. The figures are identical
for either positive or negative Remote On/Off logic.
INPUT CURRENT,(A)
Io = 32.5 A
3
Io = 0 A
2.5
2
1.5
1
0.5
0
25
35
45
55
65
75
INPUT VOLTAGE, VIN (V)
Figure 25. Typical Start-Up (Input Current)
characteristics at room temperature.
VO (V) (0.5V/div)
Io = 65 A
VOn/off (V) (10V/div)
4
3.5
ON/OFF VOLTAGE OUTPUT VOLTAGE
4.5
TIME, t (1ms/div)
Figure 28. Typical Start-Up Characteristics from
Remote ON/OFF.
88
86
EFFICIENCY (%)
84
82
V i = 36 V
80
78
V i = 48 V
76
74
V i = 75 V
72
70
0
10
20
30
40
50
60
70
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (100mV/div)
IO, (A) (10A/div)
90
TIME, t (200μs/div)
OUTPUT CURRENT, Io (A)
OUTPUT VOLTAGE
VO (V) (50mV/div)
36 Vin
48 Vin
75 Vin
TIME, t (1μs/div)
Figure 27. Typical Output Ripple and Noise at Room
temperature and Io = Io,max.
LINEAGE POWER
Figure 29. Transient Response to Dynamic Load
Change from 50% to 25% of full load current.
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (100mV/div)
IO, (A) (10A/div)
Figure 26. Converter Efficiency Vs Load at Room
temperature.
TIME, t (200μs/div)
Figure 30. Transient Response to Dynamic Load
Change from 25% to 50 % of full load current.
10
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Characteristic Curves (continued)
INPUT CURRENT,(A)
Io = 35 A
2.5
Io = 0 A
2
1.5
1
0.5
0
25
35
45
55
65
75
VO (V) (0.5V/div)
Io = 70 A
3
VOn/off (V) (5V/div)
4
3.5
ON/OFF VOLTAGE OUTPUT VOLTAGE
The following figures provide typical characteristics for the JRW070A0M (1.5V, 70A) at 25ºC. The figures are identical
for either positive or negative Remote On/Off logic.
INPUT VOLTAGE, VIN (V)
TIME, t (1ms/div)
Figure 31. Typical Start-Up (Input Current)
characteristics at room temperature.
Figure 34. Typical Start-Up Characteristics from
Remote ON/OFF.
88
86
EFFICIENCY (%)
84
82
V i = 36 V
80
78
V i = 48 V
76
74
V i = 75 V
72
70
0
10
20
30
40
50
60
70
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (100mV/div)
IO, (A) (10A/div)
90
TIME, t (200μs/div)
OUTPUT CURRENT, Io (A)
OUTPUT VOLTAGE
VO (V) (20mV/div)
36 Vin
48 Vin
75 Vin
TIME, t (1μs/div)
Figure 33. Typical Output Ripple and Noise at Room
temperature and Io = Io,max.
LINEAGE POWER
Figure 35. Transient Response to Dynamic Load
Change from 50% to 25% of full load current.
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (100mV/div)
IO, (A) (10A/div)
Figure 32. Converter Efficiency Vs Load at Room
temperature.
TIME, t (200μs/div)
Figure 36. Transient Response to Dynamic Load
Change from 25% to 50 % of full load current.
11
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Characteristic Curves (continued)
Io = 70 A
INPUT CURRENT,(A)
2.5
Io = 35 A
2
Io = 0 A
1.5
1
0.5
0
25
35
45
55
65
75
VOn/off (V) (5V/div)
3
ON/OFF VOLTAGE OUTPUT VOLTAGE
3.5
VO (V) (0.5V/div)
The following figures provide typical characteristics for the JRW070A0P (1.2V, 70A) at 25ºC. The figures are identical
for either positive or negative Remote On/Off logic.
INPUT VOLTAGE, VIN (V)
TIME, t (1ms/div)
Figure 37. Typical Start-Up (Input Current)
characteristics at room temperature.
Figure 40. Typical Start-Up Characteristics from
Remote ON/OFF.
84
82
EFFICIENCY (%)
80
78
V i = 36 V
76
V i = 48 V
74
V i = 75 V
72
70
0
10
20
30
40
50
60
70
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (100mV/div)
IO, (A) (10A/div)
86
TIME, t (200μs/div)
OUTPUT CURRENT, Io (A)
OUTPUT VOLTAGE
VO (V) (20mV/div)
36 Vin
48 Vin
75 Vin
TIME, t (1μs/div)
Figure 39. Typical Output Ripple and Noise at Room
temperature and Io = Io,max.
LINEAGE POWER
Figure 41. Transient Response to Dynamic Load
Change from 50% to 25% of full load current.
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (100mV/div)
IO, (A) (10A/div)
Figure 38. Converter Efficiency Vs Load at Room
temperature.
TIME, t (200μs/div)
Figure 42. Transient Response to Dynamic Load
Change from 50% to 75 % of full load current.
12
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Test Configurations
Design Considerations
Input Source Impedance
The power module should be connected to a low
ac-impedance source. A highly inductive source
impedance can affect the stability of the power
module. For the test configuration in Figure 43, a
100μF electrolytic capacitor (ESR< 0.7Ω at 100kHz),
mounted close to the power module helps ensure the
stability of the unit. Consult the factory for further
application guidelines.
Note: Measure input reflected-ripple current with a simulated source
inductance (LTEST) of 12 µH. Capacitor CS offsets possible battery
impedance. Measure current as shown above.
Figure 43. Input Reflected Ripple Current Test
Setup.
Note: Use a 1.0 µF ceramic capacitor and a 10 µF aluminum or
tantalum capacitor. Scope measurement should be made using a
BNC socket. Position the load between 51 mm and 76 mm (2 in. and
3 in.) from the module.
Figure 44. Output Ripple and Noise Test Setup.
Output Capacitance
High output current transient rate of change (high
di/dt) loads may require high values of output
capacitance to supply the instantaneous energy
requirement to the load. To minimize the output
voltage transient drop during this transient, low E.S.R.
(equivalent series resistance) capacitors may be
required, since a high E.S.R. will produce a
correspondingly higher voltage drop during the
current transient.
Output capacitance and load impedance interact with
the power module’s output voltage regulation control
system and may produce an ’unstable’ output
condition for the required values of capacitance and
E.S.R.. Minimum and maximum values of output
capacitance and of the capacitor’s associated E.S.R.
may be dictated, depending on the module’s control
system.
The process of determining the acceptable values of
capacitance and E.S.R. is complex and is loaddependant. Lineage Power provides Web-based tools
to assist the power module end-user in appraising
and adjusting the effect of various load conditions and
output capacitances on specific power modules for
various load conditions.
Safety Considerations
Note: All measurements are taken at the module terminals. When socketing,
place Kelvin connections at module terminals to avoid measurement errors due
to socket contact resistance.
Figure 45. Output Voltage and Efficiency Test
Setup.
LINEAGE POWER
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and
separation requirements of the end-use safety agency
standard, i.e., UL* 60950-1 Recognized, CSA† C22.2
‡
No. 60950-3-01 Certified, and EN 60950-1 (VDE
0805): 2001-12 Licensed.
These converters have been evaluated to the spacing
requirements for Basic Insulation per the above safety
standards. For Basic Insulation models (“-B” Suffix),
1500 Vdc is applied from Vi to Vo to 100% of outgoing
production.
For end products connected to –48V dc, or –60Vdc
nominal DC MAINS (i.e. central office dc battery
plant), no further fault testing is required.
13
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Safety Considerations (continued)
*Note: -60V dc nominal battery plants are not
available in the U.S. or Canada.
For all input voltages, other than DC MAINS, where
the input voltage is less than 60V dc, if the input
meets all of the requirements for SELV, then:
ƒ
The output may be considered SELV. Output
voltages will remain within SELV limits even
with internally-generated non-SELV voltages.
Single component failure and fault tests were
performed in the power converters.
ƒ
One pole of the input and one pole of the
output are to be grounded, or both circuits are
to be kept floating, to maintain the output
voltage to ground voltage within ELV or SELV
limits.
For all input sources, other than DC MAINS, where
the input voltage is between 60 and 75V dc
(Classified as TNV-2 in Europe), the following must
be meet, if the converter’s output is to be evaluated
for SELV:
The input source is to be provided with
reinforced insulation from any hazardous voltage,
including the ac mains.
ƒ
One Vi pin and one Vo pin are to be reliably
earthed, or both the input and output pins are to
be kept floating.
ƒ
Another SELV reliability test is conducted on
the whole system, as required by the safety
agencies, on the combination of supply source
and the subject module to verify that under a
single fault, hazardous voltages do not appear at
the module’s output.
ƒ
The power module has ELV (extra-low voltage)
outputs when all inputs are ELV.
All flammable materials used in the manufacturing of
these modules are rated 94V-0.
The input to these units is to be provided with a
maximum 20A fast-acting (or time-delay) fuse in the
unearthed lead.
LINEAGE POWER
14
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Feature Descriptions
Overtemperature Protection
Remote On/Off
These modules feature an overtemperature protection
circuit to safeguard against thermal damage. The
circuit shuts down and latches off the module when
the maximum device reference temperature is
exceeded. The module can be restarted by cycling
the dc input power for at least one second or by
toggling the remote on/off signal for at least one
second.
Two remote on/off options are available. Positive logic
remote on/off turns the module on during a logic-high
voltage on the ON/OFF pin, and off during a logic low.
Negative logic remote on/off turns the module off
during a logic high and on during a logic low. Negative
logic, device code suffix "1," is the factory-preferred
configuration. To turn the power module on and off,
the user must supply a switch to control the voltage
between the on/off terminal and the VI (-) terminal
(Von/off). The switch can be an open collector or
equivalent (see Figure 46). A logic low is Von/off = 0
V to I.2 V. The maximum Ion/off during a logic low is 1
mA. The switch should maintain a logic-low voltage
while sinking 1 mA. During a logic high, the maximum
Von/off generated by the power module is 15 V. The
maximum allowable leakage current of the switch at
Von/off = 15V is 50 µA. If not using the remote on/off
feature, perform one of the following to turn the unit
on:
For negative logic, short ON/OFF pin to VI(-).
For positive logic: leave ON/OFF pin open.
Figure 46. Remote On/Off Implementation.
Overcurrent Protection
To provide protection in a fault output overload
condition, the module is equipped with internal
current-limiting circuitry and can endure current limit
for few seconds. If overcurrent persists for few
seconds, the module will shut down and remain latchoff. The overcurrent latch is reset by either cycling the
input power or by toggling the on/off pin for one
second. If the output overload condition still exists
when the module restarts, it will shut down again. This
operation will continue indefinitely until the
overcurrent condition is corrected.
An auto-restart option is also available.
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout
limit, the module operation is disabled. The module
will begin to operate at an input voltage above the
undervoltage lockout turn-on threshold.
LINEAGE POWER
Over Voltage Protection
The output overvoltage protection consists of circuitry
that monitors the voltage on the output terminals. If
the voltage on the output terminals exceeds the over
voltage protection threshold, then the module will
shutdown and latch off. The overvoltage latch is reset
by either cycling the input power for one second or by
toggling the on/off signal for one second. The
protection mechanism is such that the unit can
continue in this condition until the fault is cleared.
Remote sense
Remote sense minimizes the effects of distribution
losses by regulating the voltage at the remote-sense
connections. The voltage between the remote-sense
pins and the output terminals must not exceed the
output voltage sense range given in the Feature
Specifications table i.e.:
[Vo(+) – Vo(-)] – [SENSE(+) – SENSE(-)] ≤ 10% of
Vo,nom.
The voltage between the Vo(+) and Vo(-) terminals
must not exceed the minimum output overvoltage
shut-down value indicated in the Feature
Specifications table. This limit includes any increase
in voltage due to remote-sense compensation and
output voltage set-point adjustment (trim). See Figure
47. If not using the remote-sense feature to regulate
the output at the point of load, then connect
SENSE(+) to Vo(+) and SENSE(-) to Vo(-) at the
module.
Although the output voltage can be increased by both
the remote sense and by the trim, the maximum
increase for the output voltage is not the sum of both.
The maximum increase is the larger of either the
remote sense or the trim. The amount of power
delivered by the module is defined as the voltage at
the output terminals multiplied by the output current.
When using remote sense and trim: the output
voltage of the module can be increased, which at the
same output current would increase the power output
of the module. Care should be taken to ensure that
the maximum output power of the module remains at
or below the maximum rated power.
15
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Feature Descriptions (continued)
Remote sense (continued)
⎛ Vo, nom * (100 + Δ%) (100 + 2 * Δ%) ⎞
Radj − up = ⎜
−
⎟KΩ
0.6 * Δ%
Δ%
⎝
⎠
Where,
Δ% =
Vo , nom − Vdesired
× 100
Vo , nom
Vdesired = Desired output voltage set point (V).
Figure 47. Effective Circuit Configuration for
Single-Module Remote-Sense Operation Output
Voltage.
Output Voltage Programming
Trimming allows the user to increase or decrease the
output voltage set point of a module. This is
accomplished by connecting an external resistor
between the TRIM pin and either the SENSE(+) or
SENSE(-) pins. The trim resistor should be positioned
close to the module.
If not using the trim feature, leave the TRIM pin open.
With an external resistor between the TRIM and
SENSE(-) pins (Radj-down), the output voltage set
point (Vo,adj) decreases (see Figure 36). The
following equation determines the required externalresistor value to obtain a percentage output voltage
change of Δ%.
For output voltages: 1.2V – 12V
The voltage between the Vo(+) and Vo(-) terminals
must not exceed the minimum output overvoltage
shut-down value indicated in the Feature
Specifications table. This limit includes any increase
in voltage due to remote-sense compensation and
output voltage set-point adjustment (trim). See Figure
48.
Although the output voltage can be increased by both
the remote sense and by the trim, the maximum
increase for the output voltage is not the sum of both.
The maximum increase is the larger of either the
remote sense or the trim.
The amount of power delivered by the module is
defined as the voltage at the output terminals
multiplied by the output current. When using remote
sense and trim, the output voltage of the module can
be increased, which at the same output current would
increase the power output of the module. Care should
be taken to ensure that the maximum output power of
the module remains at or below the maximum rated
power.
⎛ 100
⎞
Radj − down = ⎜
− 2 ⎟ KΩ
⎝ Δ%
⎠
Where,
Δ% =
Vo , nom − Vdesired
× 100
Vo , nom
Vdesired = Desired output voltage set point (V).
With an external resistor connected between the
TRIM and SENSE(+) pins (Radj-up), the output
voltage set point (Vo,adj) increases (see Figure 37).
Figure 48. Circuit Configuration to Decrease
Output Voltage.
The following equation determines the required
external-resistor value to obtain a percentage output
voltage change of Δ%.
For output voltages: 1.5V – 12V
⎛ Vo, nom * (100 + Δ%) (100 + 2 * Δ%) ⎞
−
Radj − up = ⎜
⎟KΩ
Δ%
⎝ 1.225* Δ%
⎠
For output voltage: 1.2V
LINEAGE POWER
Figure 49. Circuit Configuration to Increase
Output Voltage.
16
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Feature Descriptions (continued)
Output Voltage Programming (continued)
Examples:
To trim down the output of a nominal 3.3V module
(JRW060A0F) to 3.1V
Δ% =
3.3V − 3.1V
× 100
3.3V
∆% = 6.06
⎛ 100
⎞
Radj − down = ⎜
− 2 ⎟ KΩ
⎝ 6.06
⎠
Radj-down = 14.5 kΩ
To trim up the output of a nominal 3.3V module
(JRW060A0F) to 3.6V
Δ% =
3.6V − 3.3V
× 100
3.3V
Δ% = 9.1
⎛ 3.3 * (100 + 9.1) (100 + 2 * 9.1) ⎞
Radj − up = ⎜
−
⎟KΩ
9.1
⎝ 1.225* 9.1
⎠
Rtadj-up = 19.3 kΩ
LINEAGE POWER
17
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Thermal Considerations
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel.
Heat-dissipating components are mounted on the
topside of the module. Heat is removed by
conduction, convection and radiation to the
surrounding environment. Proper cooling can be
verified by measuring the thermal reference
temperature (Tref ). The peak temperature (Tref )
occurs at the position indicated in Figures 50 - 52.
The temperature at any one of these locations should
not exceed per below table to ensure reliable
operation of the power module.
Model
Device
Tref1
Figure 51. Tref Temperature Measurement
Location for Vo= 5V.
Temperature( ºC)
JRW070A0P (1.2V)
Tref3
117
JRW070A0M (1.5V)
Tref2/ Tref3
115/118
JRW065A0Y (1.8V)
Tref3
115
JRW065A0G (2.5V)
Tref2/ Tref3
117/118
JRW060A0F (3.3V)
Tref1/ Tref2
117/118
JRW040A0A (5V)
Tref1
117
JRW017A0B (12V)
Tref1
117
Tref3
Tref1
Tref2
Figure 52. Tref Temperature Measurement
Locations for Vo= 3.3V – 1.2V.
The output power of the module should not exceed
the rated power for the module as listed in the
Ordering Information table.
Although the maximum Tref temperature of the power
modules is approximately 117 °C, you can limit this
temperature to a lower value for extremely high
reliability.
Tref1
Figure 50. Tref Temperature Measurement
Location for Vo= 12V.
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame BoardMounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE POWER
Heat Transfer via Convection
Increased airflow over the module enhances the heat
transfer via convection. Following derating figures
shows the maximum output current that can be
delivered by each module in the respective orientation
without exceeding the maximum Tref temperature
versus local ambient temperature (TA) for natural
convection through 2m/s (400 ft./min).
18
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
20
18
16
14
12
10
8
6
4
2
0
70
OUTPUT CURRENT, IO (A)
60
50
60
70
80
90
LOCAL AMBIENT TEMPERATURE, TA (°C)
40
35
2.0 m/s (400 ft./min)
1.0 m/s (200 ft./min)
15
10
Natural Convection
5
30
40
30
40
50
60
70
80
90
50
40
2.0 m/s (400 ft./min)
30
1.0 m/s (200 ft./min)
20
Natural Convection
10
0
20
30
40
50
60
70
80
90
LOCAL AMBIENT TEMPERATURE, TA (°C)
50
40
2.0 m/s (400 ft./min)
30
1.0 m/s (200 ft./min)
20
Natural Convection
10
0
20
30
40
50
60
70
80
90
LOCAL AMBIENT TEMPERATURE, TA (°C)
0
20
20
60
45
20
0
70
50
25
Natural Convection
10
Figure 56. Output Power Derating for JRW065A0G (Vo
= 2.5V) in Transverse Orientation with no baseplate;
Airflow Direction From Vin(+) to Vin(-); Vin = 48V.
OUTPUT CURRENT, IO (A)
OUTPUT CURRENT, IO (A)
Figure 53. Output Power Derating for JRW017A0B
(Vo = 12V) in Transverse Orientation with no
baseplate; Airflow Direction From Vin(+) to Vin (-);
Vin = 48V.
30
1.0 m/s (200 ft./min)
20
60
Natural Convection
40
2.0 m/s (400 ft./min)
30
70
1.0 m/s (200 ft./min)
30
40
LOCAL AMBIENT TEMPERATURE, TA (°C)
2.0 m/s (400 ft./min)
20
50
Figure 55. Output Power Derating for JRW060A0F (Vo
= 3.3V) in Transverse Orientation with no baseplate;
Airflow Direction From Vin(+) to Vin(-); Vin = 48V.
OUTPUT CURRENT, IO (A)
OUTPUT CURRENT, IO (A)
Note that the natural convection condition was
measured at 0.05 m/s to 0.1 m/s (10ft./min. to 20
ft./min.); however, systems in which these power
modules may be used typically generate natural
convection airflow rates of 0.3 m/s (60 ft./min.) due to
other heat dissipating components in the system. The
use of Figures 53 - 59 are shown in the following
example:
Example
What is the minimum airflow necessary for a
JRW060A0F operating at VI = 48 V, an output current
of 42A, and a maximum ambient temperature of 70 °C
in transverse orientation.
Solution:
Given: VI = 48V
Io = 48A
TA = 70 °C
Determine airflow (V) (Use Figure 53):
V = 1m/sec. (200ft./min.)
50
60
70
80
LOCAL AMBIENT TEMPERATURE, TA (°C)
90
Figure 57. Output Power Derating for JRW065A0Y (Vo
= 1.8V) in Transverse Orientation with no baseplate;
Airflow Direction From Vin(+) to Vin(-); Vin = 48V.
Figure 54. Output Power Derating for JRW040A0A
(Vo = 5V) in Transverse Orientation with no
baseplate; Airflow Direction From Vin(+) to Vin (-);
Vin = 48V.
LINEAGE POWER
19
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
80
OUTPUT CURRENT, IO (A)
70
60
50
40
2.0 m/s (400 ft./min)
30
1.0 m/s (200 ft./min)
20
Natural Convection
10
0
20
30
40
50
60
70
80
90
LOCAL AMBIENT TEMPERATURE, TA (°C)
Figure 58. Output Power Derating for JRW070A0M
(Vo = 1.5V) in Transverse Orientation with no
baseplate; Airflow Direction From Vin(+) to Vin(-);
Vin = 48V.
80
OUTPUT CURRENT, IO (A)
70
60
50
40
2.0 m/s (400 ft./min)
30
1.0 m/s (200 ft./min)
20
Natural Convection
10
0
20
30
40
50
60
70
80
90
LOCAL AMBIENT TEMPERATURE, TA (°C)
Figure 59. Output Power Derating for JRW070A0P(Vo
= 1.2V) in Transverse Orientation with no baseplate;
Airflow Direction From Vin(+) to Vin(-); Vin = 48V.
LINEAGE POWER
20
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Layout Considerations
The JRW power module series are low profile in order
to be used in fine pitch system and architectures. As
such, component clearances between the bottom of
the power module and the mounting board are limited.
Either avoid placing copper areas on the outer layer
directly underneath the power module or maintain a
minimum clearance through air of 0.028 inches
between any two “opposite polarity” components,
including copper traces under the module to
components on the JRW module..
temperature is 260°C, while the Pb-free solder pot is
270°C max. Not all RoHS-compliant through-hole
products can be processed with paste-through-hole
Pb or Pb-free reflow process. If additional information
is needed, please consult with your Lineage Power
representative for more details.
For modules with a “7” (case (heatplate) pin) and “-H”
(heatplate) option:
To meet Basic Insulation in the end product 1)
between the input and output of the module, or 2)
between the input and the earth ground, a series
capacitor (capable of withstanding 1500V dc) needs
to inserted between the case pin and the end
termination point, if the case pin is connected to the
input or the output of the JRW module or to earth
ground.
For additional layout guide-lines, refer to
FLTR100V10 data sheet.
Post Solder Cleaning and Drying
Considerations
Post solder cleaning is usually the final circuit-board
assembly process prior to electrical board testing. The
result of inadequate cleaning and drying can affect
both the reliability of a power module and the
testability of the finished circuit-board assembly. For
guidance on appropriate soldering, cleaning and
drying procedures, refer to Lineage Power Board
Mounted Power Modules: Soldering and Cleaning
Application Note (AP01-056EPS).
Through-Hole Lead-Free Soldering
Information
The RoHS-compliant through-hole products use the
SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant
components. They are designed to be processed
through single or dual wave soldering machines. The
pins have an RoHS-compliant finish that is compatible
with both Pb and Pb-free wave soldering processes.
A maximum preheat rate of 3°C/s is suggested. The
wave preheat process should be such that the
temperature of the power module board is kept below
210°C. For Pb solder, the recommended pot
LINEAGE POWER
21
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Mechanical Outline
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
Topside label includes Lineage Power name, product designation, and data code.
†Option Feature, Pin is not present unless one these options specified. The I_share and case pin option cannot be
specified simultaneously.
LINEAGE POWER
22
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Recommended Pad Layout
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
LINEAGE POWER
23
Data Sheet
July 21, 2008
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
Ordering Information
Please contact your Lineage Power Sales Representative for pricing, availability and optional features.
Table 3. Device Code
Product codes
Input Voltage
JRW017A0B
JRW017A0B1
JRW040A0A1
JRW060A0F1
JRW065A0G1
JRW065A0Y1
JRW070A0M1
JRW070A0P1
JRW017A0B1Z
JRW040A0A1Z
JRW060A0F1-HZ
JRW065A0G1-HZ
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
Output
Voltage
12V
12V
5V
3.3V
2.5V
1.8V
1.5V
1.2V
12V
5V
3.3V
2.5V
Output
Current
17A
17A
40A
60A
65A
65A
70A
70A
17A
40A
60A
65A
Efficiency
92%
92%
92%
91%
90%
87%
86 %
84 %
92%
92%
91%
90%
Connector
Type
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Comcodes
108967134
108967142
108965385
108965393
108965401
108965435
108965419
108965427
CC109104618
CC109107422
CC109107455
CC109107471
Table 2. Device Options
Option
Device Code Suffix
Negative remote on/off logic
Auto-restart
Pin Length: 3.68 mm ± 0.25mm (0.145 in. ± 0.010 in.)
Case pin (Available with Baseplate option only)*
Basic Insulation
Base Plate option
Output current share (Parallel Operation)*
1
4
6
7
-B
-H
-P
RoHS Compliant
-Z
*Note: The case pin and Ishare pin use the same pin location such that both options cannot be specified
simultaneously.
Asia-Pacific Headquarters
Tel: +65 6416 4283
World Wide Headquarters
Lineage Power Corporation
3000 Skyline Drive, Mesquite, TX 75149, USA
+1-800-526-7819
(Outside U.S.A.: +1-972-284-2626)
www.lineagepower.com
e-mail: [email protected]
Europe, Middle-East and Africa Headquarters
Tel: +49 89 6089 286
India Headquarters
Tel: +91 80 28411633
Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or
application. No rights under any patent accompany the sale of any such product(s) or information.
© 2008 Lineage Power Corporation, (Mesquite, Texas) All International Rights Reserved.
Document No: DS03-120 ver 1.23
PDF name: jrw017-070a_series.ds.pdf