DCCOM B04MF

B04AF
THRU
B04MF
DC COMPONENTS CO., LTD.
R
RECTIFIER SPECIALISTS
TECHNICAL SPECIFICATIONS OF SINGLE-PHASE SURFACE MOUNT BRIDGE RECTIFIER
VOLTAGE RANGE - 50 to 1000 Volts
CURRENT - 0.4 Ampere
FEATURES
*
*
*
*
*
*
Ideal for automated placement
Low profile space
Low forward voltage grop
Low leakage current
High forward surge capability
Glass passivated junction
MBF
.106(2.70)
.090(2.30)
MECHANICAL DATA
*
*
*
*
*
*
Case: Molded plastic
Epoxy: UL 94V-0 rate flame retardant
Terminals: MIL-STD-202E, Method 208 guaranteed
Polarity: Symbols molded or marked on body
Mounting position: Any
Weight: 0.12 gram
.043(1.10)
.020(0.50)
.276(7.00)
.260(6.60)
.236(6.00)
.220(5.60)
.004(0.10)
Max.
.016(0.41)
.006(0.15)
.035(0.90)
.020(0.50)
.197(5.00)
.181(4.60)
.063(1.60)
.047(1.20)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
SYMBOL
B04AF
B04BF
B04DF
B04GF
B04JF
B04KF
B04MF
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Bridge Input Voltage
VRMS
35
70
140
280
420
560
700
Volts
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
1000
Maximum Average Forward Output Current
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC Method)
0.4
Amps
I FSM
15
Amps
VF
1.1
Volts
Maximum DC Forward Voltage Drop per Bridge
Element at 0.4A DC
o
Maximum Reverse Current at rated
@T A = 25 C
DC Blocking Voltage per element
@T A = 125 o C
Typical Junction Capacitance ( Note1)
Typical Thermal Resistance (Note 2)
Operating and Storage Temperature Range
NOTES : 1. Measured at 1 MHZ and applied reverse voltage of 4.0 volts.
2. On FR-4 P.C.B. with 0.035 x0.06" (0.9x1.5mm) copper pads.
Volts
IO
IR
5.0
µAmps
100
CJ
13
RθJ A
120
T J, T STG
-55 to + 150
pF
0
C/W
0
C
RATING AND CHARACTERISTIC CURVES (B04AF THRU B04MF)
FIG. 1 - DERATING CURVE FOR OUTPUT
CURRENT
PEAK FORWARD SURGE CURRENT, (A)
AVERAGE FORWARD CURRENT, (A)
0.5
0.4
0.3
0.2
0.1
Single Phase Half Wave 60Hz
Resistive or Inductive Load
0
0
30
60
90
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
120
30
8.3ms Single Half Sine-Wave
JEDEC Method
25
20
15
10
5
0
150
1
10
AMBIENT TEMPERATURE, (oC)
NUMBER OF CYCLES AT 60 Hz
10
1.0
TJ = 25OC
0.1
Pulse Width = 300 µS
1% Duty Cycle
0.01
.4
.6
.8
1.0
1.2
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
INSTANTANEOUS REVERSE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT, (A)
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
.2
100
TJ= 125oC
10
1.0
TJ= 75oC
.01
TJ= 25oC
0.01
10
20
40
60
80
100
120
PERCENT OF RATED PEAK REVERSE
VOLTAGE, (%)
DC COMPONENTS CO., LTD.
R
100
140