VICOR VI-A11-CU

12 1-800-735-6200
VI-IAM ™
Input Attenuator
Modules
Features
■ Inputs: 24, 48 and 300Vdc
■ High Surge Withstand:
– Bellcore
– British Telecom BTR 2511
– IEC-60801-5
■ EMI/RFI Specifications:
– Bellcore TR-TSY-000513
– British Telecom BTR 2511
– FCC Level “A”
– EN55022 Level “B”
■ UL, CSA, TÜV, VDE, BABT
■ 97% Efficiency
■ Input Reverse Polarity Protection
■ Logic Disable
■ Expansion Output for Arrays
■ Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
■ CE Marked
Product Highlights
The Input Attenuator Module (VI-IAM) is
a component-level, DC input front end
filter designed to occupy minimum board
space while providing maximum protection
for today’s sophisticated electrical
systems. The VI-IAM, in combination
with Vicor 24, 48 and 300Vdc input
modules, provides a highly efficient, high
density power system with outputs from
1 to 95Vdc and power expandable from
25 to 800W. Your system will benefit from
the small size, efficiency and inherent
reliability of Vicor’s component-level
converters, while meeting the toughest
demands of Telecommunications and
Industrial power applications.
VI-IAM Specifications
(typical at TBP = 25°C, nominal line, 75% load, unless otherwise specified)
PARAMETER
Input Range/Power Limit
VI-A11-CU
VI-AWW-CU
VI-A33-CQ
VI-ANN-CQ
VI-A66-CQ
Isolation
Size
Weight
EMI/ RFI (conducted
emissions)
MIN
TYP
MAX
POWER
21Vdc
18Vdc
42Vdc
36Vdc
200Vdc
24Vdc 32Vdc
200W
Delivered power is
24Vdc 36Vdc
200W
from any combination
48Vdc 60Vdc
400W
of DC-DC converters
48Vdc 76Vdc
400W
300Vdc 400Vdc
400W
1,500 VRMS
Input/Output to Base
2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7)
3.0 Ounces (85 Grams)
Meets Bellcore TR-TSY-000513, Issue 2, Rev. 1
(24 and 48V Input);
British Telecom BTR 2511, Issue 2
(24 and 48V Input);
FCC Part 15, Class A, EN55022 Class B
Transient Protection
Meets Bellcore TA-TSY-001003, Issue 1, 9/89
British Telecom BTR 2511, IEC 61000-4-5 Level 2(VI-A66 only)
Reverse Polarity Protection No damage to unit
Product Grade Specifications
PRODUCT GRADE
PARAMETER
Storage Temp.
Operating Temp.
(Baseplate)
E
–20°C to +105°C
–10°C to +100°C
C
–40°C to +105°C
–25°C to +100°C
I
–55°C to +105°C
–40°C to +100°C
Long Term Safe Operating Area Curves
(1% duty cycle max., Zs = .5Ω, for short duration transient capability refer to specifications)
24V Inputs
Standard
100V
48V Input
Wide Range
R.E.
100V
R.E.
160V
I.S.W.
Full Load
S.D.
100V
36V
32V
1
10ms
100
I.S.W.
Full Load
276V
125V
Normal Operating Area
42V
0.1
18V
1000
1
■ VI-200 and VI-J00
(Inputs: 1, W, 3, N and 6)
■ Mega Modules
(Inputs: 1, W, 3, N and 6)
76
500V
100V
S.D.
I.S.W.
Full Load
400V
1
10ms
100
100
1000
R.E.
800V
76V
36V
0.1
10ms
300V Input
R.E.
I.S.W.
Full Load
S.D.
60V
Normal Operating Area
21V
0.1
Normal Operating Area
Compatible Products
M
–65°C to +105°C
–55°C to +100°C
Note: For alternative product grades, change the “C” in the part number to “E”, “I” or “M”
48V Wide Range Input
This combination provides
compliance with the transient
requirements of Bellcore, British
Telecom and IEC standards, and meets the
EMI/RFI specifications of Bellcore,
British Telecom and FCC Part 15, Subpart
B and EN55022.
REMARKS
S.D.
1000
500 ms
S.D.
Normal Operating Area
200V
0.1
1
10ms
100
1000
500 ms
12 1-800-735-6200
Mechanical Drawing
2.28 (57,9)
.49
(12,4)
1.30 (33,0)
.65
(16,5)
.080 Dia (2) places
Solder plate
over copper alloy
.30 (7,6)
±.015 (0,38)
4
9
3
2.10
(53,4)
.15 (3,8)
Pin #
1
2
3
4
5
6
7
8
9
8
VI-IAM
7
2
6
1
5
FULL R
.15 (3,8)
1.40
1.00 (35,6)
.70 (25,4)
.40 (17,8)
(10,2)
.35 (8,9)
± .015 (0,38)
Function
+In
+In
–In
–In
+Out
Gate In
Parallel
Gate Out
–Out
.040 (1,0) Dia (7) places
Solder plate
over copper alloy
Product ID
this surface
2.40 (61,0)
1.90 (48,3)
.30 (7,6) Min.
.22 (5,6) Min.
1.75 (44,4) Max.
+.030 (0,76)
.50 (12,7) -.000 (0)
.01
.12 (3,0)
Aluminum Base
77