MEANWELL TS

TS-1500
1500W True Sine Wave DC-AC Power Inverter
series
Features :
True sine wave output (THD<3%)
High surge power up to 3000W
High efficiency up to 91%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Optional monitoring software
E13
3 years warranty
SPECIFICATION
MODEL
TS-1500-112
TS-1500-124
TS-1500-148
TS-1500-212
TS-1500-224
TS-1500-248
1500W
RATED POWER (Typ.)
MAXIMUM OUTPUT POWER (Typ.) 1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles
OUTPUT
AC VOLTAGE
100 / 110 / 115 / 120VAC selectable by setting button
200 / 220 / 230 / 240VAC selectable by setting button
FREQUENCY
60 0.1Hz
50 0.1%Hz
WAVEFORM
50/60Hz selectable by setting button S.W
3.0%
AC REGULATION (Typ.)
SAVING MODE (Typ.)
Default disabled. Load
FRONT PANEL INDICATOR
Battery voltage level, output load level, saving mode, fault and operation status
5W will be changed to standby mode
BAT. VOLTAGE
12V
24V
48V
12V
24V
48V
42 ~ 60VDC
37.5A
10.5 ~ 15VDC
150A
21 ~ 30VDC
42 ~ 60VDC
75A
37.5A
89%
Open & sealed Lead Acid
89%
88%
90%
91%
40A*5
11.3 4%
30A*3
22.5 4%
30A*2
45 4%
40A*5
11.3 4%
30A*3
22.5 4%
30A*2
45 4%
10.5 4%
21 4%
42 4%
10.5 4%
21 4%
42 4%
68
68
21 ~ 30VDC
75A
18W @ standby saving mode
VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC
DC CURRENT (Typ.)
Note.5 150A
INPUT
NO LOAD DISSIPATION
1mA
OFF MODE CURRENT DRAW
EFFICIENCY (Typ.)
Note.2 87%
BATTERY TYPES
FUSE
BATTERY BAT. LOW ALARM
INPUT
PROTECTION BAT. LOW SHUTDOWN
REVERSE POLARITY
By internal fuse open
82
OVER TEMPERATURE
LVD
SAFETY &
WITHSTAND VOLTAGE
EMC
EMC EMISSION
EMC IMMUNITY
CONTROL WIRING
OTHERS
NOTE
DIMENSION
PACKING
5
96
5
5
5
68
5
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
UL458 (only for "GFCI" receptacle-Type F )
@ 100% load ; 60 @ 50% load
20% ~ 90% RH non-condensing
None
Note.3 0 ~ +40
STORAGE TEMP., HUMIDITY
VIBRATION
SAFETY STANDARDS
82
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
GFCI PROCTECTION
ENVIRONMENT
5
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power transistor
OUTPUT SHORT
OUTPUT
PROTECTION
OVER LOAD (Typ.)
WORKING TEMP.
WORKING HUMIDITY
50/60Hz selectable by setting button S.W
Note.2 True sine wave (THD<3%) at rated input voltage
-30 ~ +70
/ -22 ~ +158oF, 10 ~ 95% RH
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
UL458 (only for "GFCI" receptacle-Type F ) None
None
Bat I/P - AC O/P:3.0KVAC
EN60950-1
AC O/P - FG:1.5KVAC
Compliance to FCC class A
None
Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN61000-4-2,3,8
RJ11 -RS232 (Option)
420*220*88mm (L*W*H)
6.81Kg; 2pcs/14.6Kg/1.61CUFT
1.Output derating capacity referenced by curve 1.
2.THD and Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage.
3.Output derating capacity referenced by curve 2.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.
5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage.
File Name:TS-1500-SPEC 2012-02-21
TS-1500
1500W True Sine Wave DC-AC Power Inverter
TS
1500
112 A
A :TYPE A OUTLET
B :TYPE B OUTLET
C :TYPE C OUTLET
D :TYPE D OUTLET
E :TYPE E OUTLET
F :TYPE F OUTLET
12:12VDC
Bat. Voltage: 24:24VDC
48:48VDC
TS:True sine wave inverter
Output:
O/P Wattage:1500W
series
1:110VAC
2:230VAC
AC Output Receptacles (optional)
Receptacle type
TYPE-A
TYPE-B
TYPE-C
TYPE-D
TYPE-E
TYPE-F
USA
EUROPE
AUSTRALIA
U.K
JAPAN
GFCI
Country
E13
Certificate
E13
E13
(Expect for 48V input)
Derating Curve
Mechanical Specification
Unit:mm
100
LOAD (%)
11.05
80
Cat.No.(1GG1HS-212)
Wire Range(10-4 AWG Str
Cu Soldered Wires)
Torque (17.7-26.5 in lb)
Inverter
Inverter
Chassis
Ground
Inverter
60
40
20
Inverter
ENG
DC
INPUT
POS
WARNING:
Reverse Polarity
Will Damage The
0
10
20
30
40
50
60
70
AMBIENT TEMPERATURE ( )
CURVE 1
48
12.1
Air flow
direction
100
LOAD (%)
108.4
80
60
40
10
20
7
10.5VDC
21VDC
42VDC
11.5VDC
23VDC
46VDC
15VDC
30VDC
60VDC
(HORIZONTAL)
BATTERY INPUT VOLTAGE (V)
CURVE 2
203.2
420
27.45
57.75
36.25
15.6
AC OUTPUT
ON
BATTERY
Setting
LOAD
OFF
100
100
INVERTER
On
0
0
Bat Low
Saving
Remote
port
Type-A
AC OUTPUT
ON
BATTERY
Setting
LOAD
OFF
100
100
INVERTER
On
0
0
Bat Low
Saving
Remote
port
207
220
Type-B
File Name:TS-1500-SPEC 2012-02-21