SAW Filters TMX W306 SAW Passband Filter - Remote Control - RF Preliminary Specification (Rev-1) Technical overview ..............................................................P01 Matching Network for 50Ω / 50Ω Configuration ...................P01 Typical Response (Measurement) .......................................P02 Package Drawing..................................................................P02 TMX W306 SAW PASSBAND Filter – Remote Control - RF March 17th, 2005 Specification (Rev 1) Electrical Parameters Unit Ω Source Impedance (single ended) Typical (1) Minimum - Maximum (2) - (2) 50 Ω - 50 - MHz - 916 - 20 MHz to 850 MHz dB 50 55 - 850 MHz to 900 MHz dB 40 45 - 900 MHz to 902 MHz dB 35 40 - 929 MHz to 933 MHz dB 25 30 - 950 MHz to 1000 MHz dB 40 50 - 1000 MHz to 1500 MHz Load Impedance (single ended) Center Frequency fo Absolute Attenuation dB 40 45 - Maximum Insertion Loss in 915 MHz-917 MHz dB - 2.8 4.0 Ripple in 915 MHz-917 MHz dB - 0.2 1.0 Length x Width mm² - 3.0 x 3.0 - Height mm - 1.3 1.35 Package type & size Pin Out Input 1 Output 2 Case Ground 3 To Be Grounded 3 Notes : (1) Typical values are nominal performances at room temperature (2) No external matching circuit is required 50 Ω / 50 Ω CONFIGURATION Input 50 Ω Single Output 50 Ω Single GND Maximum Ratings Rating Operating Temperature Range Storage Temperature Range Input Power Unit -20 to +50 -40 to +85 15 TA Value °C °C dBm 1 TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum performance and cost. TMX W306 SAW PASSBAND Filter – Remote Control - RF March 17th, 2005 Specification (Rev 1) TYPICAL S21 RESPONSE References Scales CENTER FREQUENCY LOSS REFERENCE DELAY REFERENCE PHASE REFERENCE 0 = = = = 0 0 0 0 MHz dB µs deg SCALE_FREQUENCY = 10 MHz/div -10 -20 -30 -40 -50 -60 -70 -80 880 900 920 940 960 PACKAGE DRAWING 2 TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum performance and cost.