TEMEX TMXW306

SAW Filters
TMX W306
SAW Passband Filter - Remote Control - RF
Preliminary Specification (Rev-1)
Technical overview ..............................................................P01
Matching Network for 50Ω / 50Ω Configuration ...................P01
Typical Response (Measurement) .......................................P02
Package Drawing..................................................................P02
TMX W306
SAW PASSBAND Filter – Remote Control - RF
March 17th, 2005
Specification (Rev 1)
Electrical Parameters
Unit
Ω
Source Impedance (single ended)
Typical (1)
Minimum
-
Maximum
(2)
-
(2)
50
Ω
-
50
-
MHz
-
916
-
20 MHz to 850 MHz
dB
50
55
-
850 MHz to 900 MHz
dB
40
45
-
900 MHz to 902 MHz
dB
35
40
-
929 MHz to 933 MHz
dB
25
30
-
950 MHz to 1000 MHz
dB
40
50
-
1000 MHz to 1500 MHz
Load Impedance (single ended)
Center Frequency fo
Absolute Attenuation
dB
40
45
-
Maximum Insertion Loss in 915 MHz-917 MHz
dB
-
2.8
4.0
Ripple in 915 MHz-917 MHz
dB
-
0.2
1.0
Length x Width
mm²
-
3.0 x 3.0
-
Height
mm
-
1.3
1.35
Package type & size
Pin Out
Input
1
Output
2
Case Ground
3
To Be Grounded
3
Notes :
(1) Typical values are nominal performances at room temperature
(2) No external matching circuit is required
50 Ω / 50 Ω CONFIGURATION
Input
50 Ω
Single
Output
50 Ω
Single
GND
Maximum Ratings
Rating
Operating Temperature Range
Storage Temperature Range
Input Power
Unit
-20 to +50
-40 to +85
15
TA
Value
°C
°C
dBm
1
TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum performance and cost.
TMX W306
SAW PASSBAND Filter – Remote Control - RF
March 17th, 2005
Specification (Rev 1)
TYPICAL S21 RESPONSE
References
Scales
CENTER FREQUENCY
LOSS REFERENCE
DELAY REFERENCE
PHASE
REFERENCE
0
=
=
=
=
0
0
0
0
MHz
dB
µs
deg
SCALE_FREQUENCY
= 10
MHz/div
-10
-20
-30
-40
-50
-60
-70
-80
880
900
920
940
960
PACKAGE DRAWING
2
TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum performance and cost.