TOSHIBA TLSH263P

TLSH263P
TOSHIBA LED Lamp InGaAℓP Red Light Emission
TLSH263P
Panel Circuit Indicator
Unit in mm
·
5.0mm diameter
·
InGaAℓP red LED
·
All plastic mold type.
·
Colorless clear lens
·
Low drive current , high intensity red light emission
·
All plastic molded lens, provides an excellent on−off contrast ratio.
·
Fast response time,capable of pulse operation.
·
High power luminous intensity
·
Without stand−offs.
·
Wide radiation pattern.
·
Applications: Suitable for backlighting.
Recommended forward current: IF = 15~20mA(DC)
Maximum Ratings (Ta = 25°C)
Characteristic
Symbol
Rating
Unit
Forward current (DC)
IF
50
mA
Reverse voltage
VR
4
V
Power dissipation
PD
125
mW
Operating temperature range
Topr
-30~85
°C
Storage temperature range
Tstg
-40~120
°C
1
JEDEC
―
EIAJ
―
TOSHIBA
4−5U1
Weight: 0.25 g
2002-09-25
TLSH263P
Electrical And Optical Characteristics (Ta = 25°C)
Characteristic
Symbol
Test Condition
Min
Typ.
Max
Unit
Forward voltage
VF
IF = 20mA
―
2.1
2.5
V
Reverse current
IR
VR = 4V
―
―
50
µA
Luminous intensity
IV
IF = 20mA
85
300
―
mcd
(Note)
Peak emission wavelength
λp
IF = 20mA
―
623
―
nm
Spectral line half width
∆λ
IF = 20mA
―
15
―
nm
Dominant wavelength
λd
IF = 20mA
―
613
―
nm
(Note) : Lamps are classified into the following three ranks according to their luminous intensity. Measurement
tolerance for each limit is ±15%.
N: 100-200mcd, P: 180-360mcd, Q: 320-640mcd.
Precaution
·
Please be careful of the followings
Soldering temperature: 260°C max
Soldering time: 3s max
(Soldering portion of lead: Up to 2mm from the body of the device)
·
If the lead is formed, the lead should be formed up to 5mm from the body of the device without forming stress to
the resin.Soldering should be performed after lead forming.
·
This visible LED lamp also emits some IR light. If a photodetector is located near the LED lamp,please ensure
that it will not be affected by this IR light.
2
2002-09-25
TLSH263P
IV – IF
IF – VF
50
1000
Ta = 25°C
IV
(mA)
(mcd)
30
Luminous intensity
Forward current IF
10
5
3
Ta = 25°C
500
300
100
50
30
1
1
1.7
1.8
1.9
2.0
Forward voltage
2.1
VF
2.2
5
10
Forward current
30
IF
1.0
Relative luminous intensity
IV
1
0.5
0.3
−20
0
20
100
Relative Luminous Intensity –
wavelength
3
0.1
50
(mA)
(V)
IV – Tc
Relative luminous intensity
3
2.3
40
60
Case temperature Tc
0.8
0.6
0.4
0.2
0
580
80
F = 20mA
Ta = 25°C
600
620
640
660
Wavelength λ
(°C)
Radiation Pattern
680
700
(nm)
IF – Ta
80
20°
10°
0° 10°
20°
30°
30°
40°
40°
50°
50°
60°
60°
70°
70°
80°
90°
Allowable forward current
IF (mA)
Ta = 25°C
60
40
20
80°
0
0.2
0.4
0.6
0.8
90°
0
0
20
40
60
80
100
Ambient temperature Ta (°C)
3
2002-09-25
TLSH263P
RESTRICTIONS ON PRODUCT USE
000707EAC
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
· Gallium arsenide (GaAs) is a substance used in the products described in this document. GaAs dust and fumes
are toxic. Do not break, cut or pulverize the product, or use chemicals to dissolve them. When disposing of the
products, follow the appropriate regulations. Do not dispose of the products with other industrial waste or with
domestic garbage.
· The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
· The information contained herein is subject to change without notice.
4