TLGE260 TENTATIVE TOSHIBA LED Lamp InGaAℓP Green Light Emission TLGE260 Panel Circuit Indicator Unit in mm · 3 mm diameter (T1) · InGaAℓP green LED · All plastic mold type. · Colorless clear lens · Low drive current, high intensity green light emission Recommended forward current: IF=15~20mA(DC) · All plastic molded lens,provides an excellent on−off contrast ratio. · Fast response time, capable of pulse operation. · High power luminous intensity · Applications: suitable for outdoor message signboard, safety equipment, etc. JEDEC ― EIAJ ― TOSHIBA 4−3L1 Weight:0.14g Maximum Ratings (Ta = 25°C) Characteristic Symbol Rating Unit Forward current (DC) IF 50 mA Reverse voltage VR 4 V Power dissipation PD 140 mW Operating temperature range Topr -30~85 °C Stprrage temperature range Tstg -40~120 °C 1 2002-09-25 TLGE260 Electrical And Optical Characteristics (Ta = 25°C) Characteristic Symbol Test Condition Min Typ. Max Unit Forward voltage VF IF=20mA ― 2.27 2.8 V Reverse current IR VR=4V ― ― 50 µA Luminous intensity IV IF=20mA 8.5 45 ― mcd (Note) Peak emission wavelength λp IF=20mA ― 574 ― nm Spectral line half width ∆λ IF=20mA ― 11 ― nm Dominant wavelength λd IF=20mA ― 571 ― nm (Note): Lamps are classified into the following ranks according to their luminous intensity. Measurement tolerance for each limit is ±15%. J: 10-20mcd, K: 18-36mcd, L: 32-64mcd Precaution · Please be careful of the followings Soldering temperature: 260°C max Soldering time: 3 s max (Soldering portion of lead: Up to 2 mm from the body of the device) · If the lead is formed, the lead should be formed up to 5 mm from the body of the device without forming stress to the resin. Soldering should be performed after lead forming. · This visible LED lamp also emits some IR light. If a photodetector is located near the LED lamp, please ensure that it will not be affected by this IR light. 2 2002-09-25 TLGE260 IF – VF IV – IF 300 Ta = 25°C 100 30 Luminous intensity (mA) Forward current IF 30 (mcd) Ta = 25°C 50 IV 100 10 5 3 50 10 5 3 1 0.5 1 1.6 1.8 2.2 2.0 2.4 Forward voltage VF 0.3 1 2.8 2.6 3 (V) 5 50 30 10 Forward current IF 100 (mA) Relative Luminous Intensity – Wavelength IV – Tc 3 1.0 IF = 20mA Relative luminous intensity 1 0.5 0.3 0.1 -20 20 0 60 40 Case temperature Tc 0.6 0.4 0.2 0 520 80 540 (°C) 580 560 600 Wavelength λ 620 640 (nm) IF – Ta Radiation Pattern 80 Ta = 25°C Anode Cathode 20° 10° 0° 10° 20° 30° 30° 40° 40° 50° 50° 60° 60° 70° 70° 80° 90° Allowable forward current IF (mA) Relative luminous intensity IV Ta = 25°C 0.8 60 40 20 80° 0 0.2 0.4 0.6 0.8 90° 1.0 0 0 20 40 60 80 100 Ambient temperature Ta (°C) 3 2002-09-25 TLGE260 RESTRICTIONS ON PRODUCT USE 000707EAC · TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc.. · The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. · Gallium arsenide (GaAs) is a substance used in the products described in this document. GaAs dust and fumes are toxic. Do not break, cut or pulverize the product, or use chemicals to dissolve them. When disposing of the products, follow the appropriate regulations. Do not dispose of the products with other industrial waste or with domestic garbage. · The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or others. · The information contained herein is subject to change without notice. 4 2002-09-25